• Title/Summary/Keyword: 3D 영상모형

Search Result 147, Processing Time 0.035 seconds

Three-dimensional analysis of soft and hard tissue changes after mandibular setback surgery in skeletal Class III patients (골격성 3급 부정교합 환자의 하악골 후퇴술 시행후 안모변화에 대한 3차원적 연구)

  • Park, Jae-Woo;Kim, Nam-Kug;Kim, Myung-Jin;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.35 no.4 s.111
    • /
    • pp.320-329
    • /
    • 2005
  • The three-dimensional (3D) changes of bone, soft tissue and the ratio of soft tissue to bony movement was investigated in 8 skeletal Class III patients treated by mandibular setback surgery. CT scans of each patient at pre- and post-operative states were taken. Each scan was segmented by a threshold value and registered to a universal three-dimensional coordinate system, consisting of an FH plane, a mid-sagittal plane, and a coronal plane defined by PNS. In the study, the grid parallel to the coronal plane was proposed for the comparison of the changes. The bone or soft tissue was intersected by the projected line from each point on the gird. The coordinate values of intersected point were measured and compared between the pre- and post-operative models. The facial surface changes after setback surgery occurred not only in the mandible, but also in the mouth corner region. The soft tissue changes of the mandibular area were measured relatively by the proportional ratios to the bone changes. The ratios at the mid-sagittal plane were $77\~102\%(p<0.05)$. The ratios at all other sagittal planes had similar patterns to the mid-sagittal plane, but with decreased values. And, the changes in the maxillary region were calculated as a ratio, relative to the movement of a point representing a mandibular movement. When B point was used as a representative point, the ratios were $14\~29\%$, and when Pog was used, the ratios were $17\~37\%(9<0.05)$. In case of the 83rd point of the grid, the ratios were $11\~22\%(p<0.05)$.

IP Modeling and Inversion Using Complex Resistivity (복소 전기비저항을 이용한 IP 탐사 모델링 및 역산)

  • Son, Jeong-Sul;Kim, Junhg-Ho;Yi, Myeong-Jong
    • Geophysics and Geophysical Exploration
    • /
    • v.10 no.2
    • /
    • pp.138-146
    • /
    • 2007
  • This paper describes 2.5D induced polarization (IP) modeling and inversion algorithms using complex resistivity. The complex resistivity method has merits for acquiring more valuable information about hydraulic parameters and pore fluid than the conventional IP methods. The IP modeling and inversion algorithms are developed by allowing complex arithmetic in existing DC modeling and inversion algorithms. The IP modeling and inversion algorithms use a 2.5D DC finite-element algorithm and a damped least-squares method with smoothness constraints, respectively. The accuracy of the IP modeling algorithm is verified by comparing its responses of two synthetic models with two different approaches: linear filtering for a three-layer model and an integral equation method for a 3D model. Results from these methods are well matched to each other. The inversion algorithm is validated by a synthetic example which has two anomalous bodies, one is more conductive but non-polarizable than the background, and the other is polarizable but has the same resistivity as the background. From the inverted section, we can cleary identify each anomalous body with different locations. Furthermore, in order to verify its efficiency to the real filed example, we apply the inversion algorithm to another three-layer model which includes phase anomaly in the second layer.

Verification of Breach Delay Effect of River Levee treated with Bio-polymer by Real-scale Experiment (실규모 실험을 통한 바이오폴리머 처리 제방의 횡월류 붕괴지연효과 검증)

  • Ko, Dongwoo;Kang, Joongu
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.220-220
    • /
    • 2021
  • 2020년 장마는 6월 중순부터 8월 중순까지 전국적으로 평균 687 mm의 강수가 내려, 1973년 이후 역대 2위 강수량을 기록하였으며, 연이은 태풍으로 큰 인명 및 재산 피해가 발생하였다. 특히, 섬진강 및 한탄천 등에서 계획홍수위를 초과하는 홍수로 인해 상당수의 제방이 월류로 인해 붕괴된 것으로 나타났다. 따라서, 향후 기후변화에 따른 연평균 강수량이 증가할 것으로 전망되는 가운데 집중호우로 인한 제방 붕괴 피해를 최소화하기 위한 고도화된 기술 개발을 통한 선제적 재발 방지대책이 필요한 시점이다. 한국건설기술연구원은 바이오폴리머라는 새로운 친환경 신소재를 이용하여 제방의 안정성 평가 기술 개발 연구를 수행하고 있다. 이에 안동하천연구센터에서는 실규모에 준하는 제방모형(높이 3 m, 사면경사 1:2, 길이 10 m 이상)을 제작하고, 제방 표면에 바이오폴리머 신소재를 처리하여 전방 월류 흐름 유도에 따른 실규모 제방붕괴실험을 수행하였다. 또한, 신소재 보강 및 무보강 조건에 따른 영상분석 기반 붕괴지연효과를 정량적으로 분석하여 신소재의 성능을 평가하였다. 하지만, 기존에 수행된 실험은 댐 붕괴 흐름과 같이 홍수파가 발생하여 제내지로 퍼져 나가는 형태로 진행되어, 보강공법의 검증에 있어 실제 하천에서 발생하는 횡월류 흐름을 재현하지 못한다는 한계를 가지고 있다. 본 연구에서는 횡월류 흐름(0.6 m3/s 이상)을 발생시켜 수리실험에 따른 축척효과(scale effect)를 최소화하고, 현장에 대한 충분한 자연성을 재현하는 것을 목표로 하여 실험을 수행하였다. 실험 조건은 1) 신소재가 처리된 식생 제방, 2) 신소재가 처리되지 않은 식생 제방으로 각각의 조건에 따른 횡월류 흐름 및 제방 붕괴를 유도하여 영상분석 기법(이미지 픽셀분석 및 3D 포인트 클라우드 모델링)을 통한 침식 저항에 관한 분석결과를 제시하였다.

  • PDF

Dosimetric effects of couch attenuation and air gaps on prone breast radiation therapy (Prone Breast Phantom을 이용한 couch 산란영향 평가)

  • Kim, Min Seok;Jeon, Soo Dong;Bae, Sun Myeong;Baek, Geum Mun;Song, Heung Gwon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.43-51
    • /
    • 2017
  • Purpose: The purpose of this study is to evaluate the dosimetric effects of couch attenuation and air gaps using 3D phantom for prone breast radiation therapy. Materials and method: A 3D printer(Builder Extreme 1000) and computed tomography (CT) images of a breast cancer patient were used to manufacture the customized breast phantom. Eclipse External Beam Planning 13.6 (Varian Medical Systems Palo Alto, CA, USA) was used to create the treatment plan with a dose of 200 cGy per fraction with 6 MV energy. The Optically Stimulated Luminescence Detector(OSLD) was used to measure the skin dose at four points (Med 1, Med 2, Lat 1, Lat 2) on the 3D phantom and ion-chamber (FC65-G) were used to perform the in-vivo dosimetry at the two points (Anterior, Posterior). The Skin dose and in-vivo dosimetry were measured with reference air gap (3 cm) and increased air gaps (1, 2, 3, 4, 5, 6 cm) from reference distance between the couch and 3D phantom. Results: As a result, measurement for the skin dose at lateral point showed a similar value within ${\pm}4%$ compared to the plan. While the air gap increased, skin dose at medial 1 was reduced. And it was also reduced over 7 % when the air gap was more than 3 cm compared to radiation therapy plan. At medial 2 it was reduced over 4 % as well. The changes of dose from variety of the air gap showed similar value within ${\pm}1%$ at posterior. As the air gap was increased, the dose at anterior was also increased and it was increased by 1 % from the air gap distance more than 3 cm. Conclusion: Dosimetrical measurement using 3D phantom is very useful to evaluate the dosimetric effects of couch attenuation and air gaps for prone breast radiation therapy. And it is possible to reduce the skin dose and increase the accuracy of the radiation dose delivery by appling the optimized air gap.

  • PDF

Analysis of Urban Heat Island Effect Using Information from 3-Dimensional City Model (3DCM) (3차원 도시공간정보를 이용한 도시열섬현상의 분석)

  • Chun, Bun-Seok;Kim, Hag-Yeol
    • Spatial Information Research
    • /
    • v.18 no.4
    • /
    • pp.1-11
    • /
    • 2010
  • Unlike the previous studies which have focused on 2-dimensional urban characteristics, this paper presents statistical models explaining urban heat island(UHI) effect by 3-dimensional urban morphologic information and addresses its policy implications. 3~dimensional informations of Columbus, Ohio arc captured from LiDAR data and building boundary informations are extracted from a building digital map, Finally NDV[ and temperature data are calculated by manipulating band 3, band 4, and thermal hand of LandSat images. Through complicated data processing, 6 independent variables(building surface area, building volume, height to width ratio, porosity, plan surface area) are introduced in simple and multiple linear regression models. The regression models are specified by Box-Tidwell method, finding the power to which the independent variable needs to raised to be in a linearity. Porosity, NDVI, and building surface area are carefully chosen as explanatory variables in the final multiple regression model, which explaining about 57% of the variability in temperatures. On reducing UHI, various implications of the results give guidelines to policy-making in open space, roof garden, and vertical garden management.

Application of Drone for Analysis of 2D Pollutant Mixing in River (하천에 유입된 오염물질의 2차원 혼합 분석을 위한 드론의 활용)

  • Seo, Il Won;Baek, Donghae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.100-100
    • /
    • 2017
  • 하천에 유입된 오염물질의 2차원 혼합거동은 하천 주흐름에 의한 이송현상과 유속 성분의 수심평균 값에 대한 공간적 편차로부터 야기되는 분산현상으로 설명 할 수 있다. 이는 3차원 이송확산 방정식으로부터 수심 적분된 2차원 이송-분산 방정식으로 수학적 유도가 가능하며, 수심방향으로 적분하는 과정에서 발생되는 농도의 분산항은 Taylor Dispersion 개념에 기초하여 종방향 및 횡방향의 2차원 분산계수로 표현된다. Fischer(1978)는 연직방향 유속분포로부터 2차원 분산계수를 추정하는 해석해를 수학적으로 유도하였으나, 실제 하천에서 정밀한 연직방향 유속분포를 계측하는 것은 많은 비용 및 노동력을 초래한다. 따라서 선행 연구자들은 2차원 혼합모형의 분산계수를 산정하고자 실험적 방법으로써 추적자실험을 수행하였다. 추적자실험은 추적자 물질을 수체에 주입한 후 농도의 변화를 관측함으로써 추적자물질이 하천에서 이송 및 분산되는 과정을 이해하는데 유용하다. 기존의 추적자실험은 고정된 위치에서 농도를 계측하여 시계열적인 농도의 변화를 관측한 후, 오염운 동결가정을 통해 종,횡방향 분산계수의 산정이 가능하지만, 오염물질 농도의 공간적 분포를 얻기에는 한계가 있다. 본 연구에서는 기존의 추적자실험법의 한계를 극복하고자 형광물질을 이용한 추적자실험을 수행함과 동시에 드론에 장착된 디지털카메라를 이용하여 항공영상을 취득 및 분석하여, 하천에 주입된 형광물질의 농도분포를 시공간적으로 추출하는 기법을 개발하고, 이를 바탕으로 오염물질의 2차원 혼합거동을 분석하였다. 본 실험은 한국건설기술연구원의 안동하천실험센터의 A3실험수로에서 수행되었으며, 실험수로는 평균 하폭 5 m, 평균 수심 0.44 m, 유량 $0.96m^3/s$의 실제 소규모 하천과 유사한 축척을 가지고 있다. 추적자물질은 Rhodamine WT 용액이 사용되었으며, 실험수로 내 설치된 15개의 형광광도계(YSI-600OMS)를 이용하여 농도를 측정하였다. 항공영상의 취득을 위해 이용된 드론은 DJI-Phantom 3 Professional 이며, 3840x2160의 해상도로 초당 30 frame의 동영상으로 취득되었다. 영상의 정합 및 좌표화를 위해 RTK-GPS를 이용하여 12개의 지상 기준점의 좌표를 취득한 후, 사영변환을 통해 영상좌표를 지상좌표로 변환하였다. 영상의 픽셀값을 농도장으로 변환하기 위해 각 RGB 밴드의 픽셀값을 통계적으로 분석하여 농도장으로 변환하였으며, 영상으로부터 얻은 농도장은 형광광도계에 의해 실측된 농도와 결정계수 0.9이상의 수준으로 정확도를 나타냈다.

  • PDF

A Research on Applicability of Drone Photogrammetry for Dam Safety Inspection (드론 Photogrammetry 기반 댐 시설물 안전점검 적용성 연구)

  • DongSoon Park;Jin-Il Yu;Hojun You
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.5
    • /
    • pp.30-39
    • /
    • 2023
  • Large dams, which are critical infrastructures for disaster prevention, are exposed to various risks such as aging, floods, and earthquakes. Better dam safety inspection and diagnosis using digital transformation technologies are needed. Traditional visual inspection methods by human inspectors have several limitations, including many inaccessible areas, danger of working at heights, and know-how based subjective inspections. In this study, drone photogrammetry was performed on two large dams to evaluate the applicability of digital data-based dam safety inspection and propose a data management methodology for continuous use. High-quality 3D digital models with GSD (ground sampling distance) within 2.5 cm/pixel were generated by flat double grid missions and manual photography methods, despite reservoir water surface and electromagnetic interferences, and severe altitude differences ranging from 42 m to 99.9 m of dam heights. Geometry profiles of the as-built conditions were easily extracted from the generated 3D mesh models, orthomosaic images, and digital surface models. The effectiveness of monitoring dam deformation by photogrammetry was confirmed. Cracks and deterioration of dam concrete structures, such as spillways and intake towers, were detected and visualized efficiently using the digital 3D models. This can be used for safe inspection of inaccessible areas and avoiding risky tasks at heights. Furthermore, a methodology for mapping the inspection result onto the 3D digital model and structuring a relational database for managing deterioration information history was proposed. As a result of measuring the labor and time required for safety inspection at the SYG Dam spillway, the drone photogrammetry method was found to have a 48% productivity improvement effect compared to the conventional manpower visual inspection method. The drone photogrammetry-based dam safety inspection is considered very effective in improving work productivity and data reliability.

Evaluation of the Image Quality According to the Pre-set Method in PET/CT Image (PET/CT 영상 획득 시 사전설정법 차이에 따른 영상 질 평가)

  • Park, Sun-Myung;Lee, Hyuk;Hong, Gun-Chul;Chung, Eun-Kyung;Choi, Choon-Ki;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.41-46
    • /
    • 2011
  • Purpose: The result of exam using an imaging device is very closely related with the image quality. Moreover, this image quality can be changed according to the condition of image acquisition and evaluation method. In this study, we evaluated the image quality according to the difference of pre-set method in PET/CT image. Materials & Methods: PET/CT Discovery STe16 (GE Healthcare, Milwaukee, USA), Chest PET phantom (Experiment 1) and 94 NEMA phantom (Experiment 2) were used. Phantom were filled with $^{18}F$-FDG maintaining hot sphere and background ratio to 4:1. In the case of experiment 1, we set the radio activity concentration on 3.5, 6.0, 8.6 kBq/mL. In the case of experiment 2, we set the radio activity concentration on 3.3, 5.5, 7.7, 9.9, 12.1, 16.5 kBq/mL. All experiments were performed with the time-set method for 2 minutes 30 seconds per frame and the count-set method with one hundred million counts in 3D mode after CT transmission scan. For the evaluation of the image quality, we compared each results by using the NECR and SNR. Results: In the experiment 1, both the NECR and SNR were increased as radioactivity concentration getting increased. The NECR was shown as 53.7, 66.9, 91.4. and SNR was shown as 7.9, 10.0, 11.7. Both the NECR and SNR were increased in time-set method. But the count-set method's pattern was not similar with the time-set method. The NECR was shown as 53.8, 69.1, 97.8, and SNR was shown as 14.1, 14.7 14.4. The SNR was not increased in count-set method. In experiment 2, results of both the NECR and SNR were shown as 45.1, 70.6, 95.3, 115.6, 134.6, 162.2 and 7.1, 8.8, 10.6, 11.5, 12.7, 14.0. These results were shown similar patten with the experiment 1. Moreover, when the count-set method was applied, the NECR was shown as 42.1, 67.3, 92.1, 112.2, 130.7, 158.7, and SNR was shown as 15.2, 15.9, 15.6, 15.4, 15.5, 14.9. The NECR was increased but SNR was not shown same pattern. Conclusion: Increment of administered radioactivity improves the quality of image unconcerned with the pre-set method. However, NECR was not influenced by increment of total acquisition counts through simple increasing scan duration without increment of administered activity. In case of count-set method, the SNR was shown similar value despite of increment of radioactivity. So, the administered activity is more important than the scan duration. And we have to consider that evaluation of image quality using only SNR may not be appropriate.

  • PDF

Verification of Drag Reduction Effect of Outer-layer Vertical Blades based on Model Test (모형선 시험을 통한 외부경계층 수직 날 배열의 저항저감효과 검증)

  • Lee, Seong Hoon;Lee, Inwon
    • Journal of the Korean Society of Visualization
    • /
    • v.16 no.3
    • /
    • pp.26-34
    • /
    • 2018
  • In the present study, an experimental assessment has been made of the drag reducing efficiency of the outer-layer vertical blades, which were first devised by Hutchins(1). A detailed flow field measurements have been performed using 2-D time resolved PIV with a view to enabling the identification of drag reduction mechanism. In addition, an experimental investigation has been made of the applicability of outer-layer vertical blades to real ship model. The arrays of outer-layer vertical blades have been installed onto the flat side and flat bottom of a 300k KVLCC model. A series of towing tank test has been carried out to investigate resistance (CTM) reduction efficiency with various geometric parameters and installed places of blades. The installation of vertical blades led to the CTM reduction of 1.44~3.17% near the service speed.

Performance Evaluation of Radiochromic Films and Dosimetry CheckTM for Patient-specific QA in Helical Tomotherapy (나선형 토모테라피 방사선치료의 환자별 품질관리를 위한 라디오크로믹 필름 및 Dosimetry CheckTM의 성능평가)

  • Park, Su Yeon;Chae, Moon Ki;Lim, Jun Teak;Kwon, Dong Yeol;Kim, Hak Joon;Chung, Eun Ah;Kim, Jong Sik
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.93-109
    • /
    • 2020
  • Purpose: The radiochromic film (Gafchromic EBT3, Ashland Advanced Materials, USA) and 3-dimensional analysis system dosimetry checkTM (DC, MathResolutions, USA) were evaluated for patient-specific quality assurance (QA) of helical tomotherapy. Materials and Methods: Depending on the tumors' positions, three types of targets, which are the abdominal tumor (130.6㎤), retroperitoneal tumor (849.0㎤), and the whole abdominal metastasis tumor (3131.0㎤) applied to the humanoid phantom (Anderson Rando Phantom, USA). We established a total of 12 comparative treatment plans by the four geometric conditions of the beam irradiation, which are the different field widths (FW) of 2.5-cm, 5.0-cm, and pitches of 0.287, 0.43. Ionization measurements (1D) with EBT3 by inserting the cheese phantom (2D) were compared to DC measurements of the 3D dose reconstruction on CT images from beam fluence log information. For the clinical feasibility evaluation of the DC, dose reconstruction has been performed using the same cheese phantom with the EBT3 method. Recalculated dose distributions revealed the dose error information during the actual irradiation on the same CT images quantitatively compared to the treatment plan. The Thread effect, which might appear in the Helical Tomotherapy, was analyzed by ripple amplitude (%). We also performed gamma index analysis (DD: 3mm/ DTA: 3%, pass threshold limit: 95%) for pattern check of the dose distribution. Results: Ripple amplitude measurement resulted in the highest average of 23.1% in the peritoneum tumor. In the radiochromic film analysis, the absolute dose was on average 0.9±0.4%, and gamma index analysis was on average 96.4±2.2% (Passing rate: >95%), which could be limited to the large target sizes such as the whole abdominal metastasis tumor. In the DC analysis with the humanoid phantom for FW of 5.0-cm, the three regions' average was 91.8±6.4% in the 2D and 3D plan. The three planes (axial, coronal, and sagittal) and dose profile could be analyzed with the entire peritoneum tumor and the whole abdominal metastasis target, with planned dose distributions. The dose errors based on the dose-volume histogram in the DC evaluations increased depending on FW and pitch. Conclusion: The DC method could implement a dose error analysis on the 3D patient image data by the measured beam fluence log information only without any dosimetry tools for patient-specific quality assurance. Also, there may be no limit to apply for the tumor location and size; therefore, the DC could be useful in patient-specific QAl during the treatment of Helical Tomotherapy of large and irregular tumors.