• Title/Summary/Keyword: 3Baseline

Search Result 2,750, Processing Time 0.027 seconds

Baseline Analysis for $3^{rd}$ order GPS Network Adjustment (국가기준점 망조정을 위한 GPS 3등기준점 기선해석)

  • Lee, Young-Jin;Jeong, Kwang-Ho;Kwon, Chan-O;Song, Jun-Ho;Cho, Jun-Rae;Nam, Gi-Beom
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2007.04a
    • /
    • pp.3-6
    • /
    • 2007
  • The GPS baseline processing and the network adjustment was required a preliminary classification and check for effective work because the observation data of GPS $3^{rd}$ order control points are enormous attain to about 12,000 points. Particularly, in baseline processing and network adjustment a inaccuracy GPS antenna heights and point names yield a gross error or a S/W computation error. For the baseline processing of observation data, the related all materials were collected and were required a final check. The factor occurring a error, in GPS the baseline processing, were inspected variously after a checking observation data. Also, baseline processing method of GPS $3^{rd}$ order control points were commented and the analysis carry out a results with a experiment. The ellipsoidal distance and height of duplication baseline was compared between adjoin campaign areas for a accuracy analysis of baseline processing. According to the result, the mean is about 1cm for horizontal direction and about 2cm for vertical direction.

  • PDF

Analysis of ERTMS/ETCS Baseline 3 for The KTCS Function Improvement (KTCS 기능개선을 위한 ERTMS/ETCS Baseline 3 상호호환성 분석)

  • Hwang, Kyung-Hwan;Woo, Hyung-Nam;Sung, Dong-Il;Lee, Key-Seo
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.14 no.5
    • /
    • pp.375-384
    • /
    • 2021
  • The development of the European Railway Traffic Management System (ERTMS) began in 1989 as part of the European Union policy to establish a unified and interoperable railway route in Europe. It is a trend that ERTMS/ETCS(European Train Control System) is becoming an international standard in the railway signaling system. As the solution to this situation, the domestic railway signaling field is also at a time when it is more necessary to develop the technology of the train control system considering interoperability. The European Railway Agency (ERA) has proposed B3R2 (Baseline 3 Release 2) for new ETCS-equipped trains after 2020.12.31. In Korea, Baseline 2.2.0 to 2.3.0d on Gyeongbu Line, Honam Line, Jeolla Line, and Gyeongchun Line was installed and now is under operating. As the Baseline upgrade continues, technical considerations and economic considerations are an occurring trend. In this paper, we analyzed the main functions and compatibility of the currently distributed European standard ERTMS/ETCS Baseline 3 and presented a plan to apply the domestic KTCS(Korean Train Control System) Baseline in the near future.

Effects of Functional Resistance Training on Gross Motor and Balance Abilities in Children with Dyskinetic Cerebral Palsy : Single Case Design (기능적인 저항훈련이 운동이상형 뇌성마비 아동의 대동작과 균형능력에 미치는 영향 : 단일사례설계)

  • Kwon, Haeyeon
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.4 no.3
    • /
    • pp.109-119
    • /
    • 2016
  • Purpose : The purpose of this research is to find clinical effects of functional resistance training using weighted vest on gross motor and balance abilities of children with dyskinetic cerebral palsy. Methods : This study selects 3 subjects for 8~12 years old who were diagnosed with children with dyskinetic cerebral palsy. The Design is ABA design of single-subject research design. Baseline(A) and TypeII Baseline(A : 12weeks) phases were received with NDT treatment, Intervention(B : 12weeks) phase provided with 40 minute functional resistance training using weighted vest in a session twice a week. In order to analyze the measure results of gross motor function and performance, balance abilities in children dyskinetic cerebral palsy during baseline, intervention and typeII baseline phase. Result : A statistically significant differences in the total GMFM including walking/running/jumping during baseline, intervention, typeII baseline, but no significant differences in the lying/rolling, sitting, crawling/kneeling and standing. A statistically significant differences in the total GMPM including dissociated movement, coordination, weight shift, stability during baseline, intervention, typeII baseline, but no significant differences in the body alignment domains. A statistically significant differences in the length and surface area ellipse of center of pressure during baseline, intervention, typeII baseline. Conclusion : The intervention method to facilitate multi-joint and closed kinematic chain movement equipped weighted vest applied functional resistance training on children with dyskinetic cerebral palsy effectively improve on gross motor function and performance, balance abilities.

Precision Evaluation of Three-dimensional Feature Points Measurement by Binocular Vision

  • Xu, Guan;Li, Xiaotao;Su, Jian;Pan, Hongda;Tian, Guangdong
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.1
    • /
    • pp.30-37
    • /
    • 2011
  • Binocular-pair images obtained from two cameras can be used to calculate the three-dimensional (3D) world coordinate of a feature point. However, to apply this method, measurement accuracy of binocular vision depends on some structure factors. This paper presents an experimental study of measurement distance, baseline distance, and baseline direction. Their effects on camera reconstruction accuracy are investigated. The testing set for the binocular model consists of a series of feature points in stereo-pair images and corresponding 3D world coordinates. This paper discusses a method to increase the baseline distance of two cameras for enhancing the accuracy of a binocular vision system. Moreover, there is an inflexion point of the value and distribution of measurement errors when the baseline distance is increased. The accuracy benefit from increasing the baseline distance is not obvious, since the baseline distance exceeds 1000 mm in this experiment. Furthermore, it is observed that the direction errors deduced from the set-up are lower when the main measurement direction is similar to the baseline direction.

Effects of vasopressin administration in the oral cavity on cardiac function and hemodynamics in rats

  • Fukami, Hayato;Sunada, Katsuhisa
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.22 no.1
    • /
    • pp.11-18
    • /
    • 2022
  • Background: The vasoconstrictive effect of epinephrine in local anesthetics affects the heart, which leads to hesitation among dentists in injecting local anesthetics into patients with cardiovascular disease. Due to its vasoconstrictive effects, the present study investigated the effects of vasopressin administration on cardiac function in rats. Methods: Experiment 1 aimed to determine the vasopressin concentration that could affect cardiac function. An arterial catheter was inserted into the male Wistar rats. Next, 0.03, 0.3, and 3.0 U/mL arginine vasopressin (AVP) (0.03V, 0.3V, and 3.0V) was injected into the tongue, and the blood pressure was measured. The control group received normal saline only. In Experiment 2, following anesthesia infiltration, a pressure-volume catheter was placed in the left ventricle. Baseline values of end-systolic elastance, end-diastolic volume, end-systolic pressure, stroke work, stroke volume, and end-systolic elastance were recorded. Next, normal saline and 3.0V AVP were injected into the tongue to measure their effect on hemodynamic and cardiac function. Results: After 3.0V administration, systolic blood pressures at 10 and 15 min were higher than those of the control group; they increased at 10 min compared with those at baseline. The diastolic blood pressures at 5-15 min were higher than those of the control group; they increased at 5 and 10 min compared with those at baseline. The preload decreased at 5 and 10 min compared to that at baseline. However, the afterload increased from 5 to 15 min compared with that of the control group; it increased at 10 min compared with that at baseline. Stroke volume decreased at 10 and 15 min compared with that of the control group; it decreased from 5 to 15 min compared with that at baseline. Stroke work decreased from 5 to 15 min compared with that of the control group; it decreased from 5 to 15 min compared with that at baseline. Conclusion: Our results showed that 3.0 U/mL concentration of vasopressin resulted in increased blood pressure, decreased stroke volume and stoke work, decreased preload and increased afterload, without any effect on myocardial contractility.

A Base Study on the Accuracy Analysis of GPS Kinematic Surveying of the Long-Baseline According to the Ephmeris (궤도력에 따른 장기선 GPS 이동측량의 정확도 분석에 관한 기초연구)

  • 강준묵;이용욱;박정현
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.18 no.2
    • /
    • pp.121-127
    • /
    • 2000
  • Kinematic GPS surveying which can obtain much 3D topographical information through short-time measurement is being utilized mainly in the short baseline less than a few kilometers. Because the decision of position for the long baseline depends on the static GPS surveying which needs long time measurement, the method for measuring the position of long baseline is needed. In this study, the accuracy of the baseline according to the baseline distance, ephemeris, and observation time by GPS surveying is analysed to confirm the application of kinematic GPS surveying for the long baseline. As the result of this, the acquisition of 3D topographical information by GPS surveying in a few minutes will be possible when PDOP is less than 4, and the fast precise ephemeris is used within 60 km. Also, the accuracy is similar to that of final precise ephemeris of IGS. If a lot of studies about the long baseline kinematic GPS surveying are processed, the acquisition of topographical information for various industry including land development will be obtained more efficiently.

  • PDF

Analysis of Baseline Accuracy by GPS Relative Positioning (GPS 상대측위에 의한 기선 정확도 분석)

  • Kang, Joon-Mook;Nim, Young-Bin;Song, Seung-Ho;Park, Joung-Hyoun
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.4 no.2 s.8
    • /
    • pp.15-22
    • /
    • 1996
  • As the exact geographical information has been nowadays required for effective developing and using of national land, in the country, there has been interested in using of GPS, and its practical use is expected. Various kinds of fundamental research for practical use of GPS is being accomplished. In this study, a test was carried out over 9 stations with baseline of the range of 1.5 to 210km, and the accuracy of baseline length by GPS relative positioning was variously considered. As result of this study, using a GPS receiving L1 frequency only, baseline accuracy for 2 hour observation was of the order of 0.3ppm for the 10km, and for I hour was below 1ppm. Using a GPS receiving dual frequency(L1/L2), baseline accuracy was of the order of 0.3ppm for the 100km to 200km as 3 hour observation using double difference methods by carrier phase. With basic on the result of this study, when observation and baseline processing are proceeded by the selected optimum observation time and using of baseline processing method, we can expect that geographical information will be acquired effectively.

  • PDF

Fully Analog ECG Baseline Wander Tracking and Removal Circuitry using HPF Based R-peak Detection and Quadratic Interpolation

  • Nazari, Masoud;Rajeoni, Alireza Bagheri;Lee, Kye-Shin
    • Journal of Multimedia Information System
    • /
    • v.7 no.3
    • /
    • pp.231-238
    • /
    • 2020
  • This work presents a fully analog baseline wander tracking and removal circuitry using high-pass filter (HPF) based R-peak detection and quadratic interpolation that does not require digital post processing, thus suitable for compact and low power long-term ECG monitoring devices. The proposed method can effectively track and remove baseline wander in ECG waveforms corrupted by various motion artifacts, whereas minimizing the loss of essential features including the QRS-Complex. The key component for tracking the baseline wander is down sampling the moving average of the corrupted ECG waveform followed by quadratic interpolation, where the R-peak samples that distort the baseline tracking are excluded from the moving average by using a HPF based approach. The proposed circuit is designed using CMOS 0.18-㎛ technology (1.8V supply) with power consumption of 19.1 ㎼ and estimated area of 15.5 ㎟ using a 4th order HPF and quadratic interpolation. Results show SNR improvement of 10 dB after removing the baseline wander from the corrupted ECG waveform.

Long Baseline GPS RTK with Estimating Tropospheric Delays

  • Choi, Byung-Kyu;Roh, Kyoung-Min;Lee, Sang Jeong
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.3 no.3
    • /
    • pp.123-129
    • /
    • 2014
  • The real-time kinematic (RTK) is one of precise positioning methods using Global Positioning System (GPS) data. In the long baseline GPS RTK, the ionospheric and tropospheric delays are critical factors for the positioning accuracy. In this paper we present RTK algorithms for long baselines more than 100 km with estimating tropospheric delays. The state vector is estimated by the extended Kalman filter. We show the experimental results of GPS RTK for various baselines (162.10, 393.37, 582.29, and 1283.57 km) by using the Korea Astronomy and Space Science Institute GPS data and one International GNSS Service (IGS) reference station located in Japan. As a result, we present that long baseline GPS RTK can provide the accurate positioning for users less than few centimeters.

Virtual Viewpoint Image Synthesis Algorithm using Multi-view Geometry (다시점 카메라 모델의 기하학적 특성을 이용한 가상시점 영상 생성 기법)

  • Kim, Tae-June;Chang, Eun-Young;Hur, Nam-Ho;Kim, Jin-Woong;Yoo, Ji-Sang
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.12C
    • /
    • pp.1154-1166
    • /
    • 2009
  • In this paper, we propose algorithms for generating high quality virtual intermediate views on the baseline or out of baseline. In this proposed algorithm, depth information as well as 3D warping technique is used to generate the virtual views. The coordinate of real 3D image is calculated from the depth information and geometrical characteristics of camera and the calculated 3D coordinate is projected to the 2D plane at arbitrary camera position and results in 2D virtual view image. Through the experiments, we could show that the generated virtual view image on the baseline by the proposed algorithm has better PSNR at least by 0.5dB and we also could cover the occluded regions more efficiently for the generated virtual view image out of baseline by the proposed algorithm.