• Title/Summary/Keyword: 345kV power system

Search Result 114, Processing Time 0.028 seconds

Development of Power System Health Algorithm (전력계통 건전성 지수 알고리즘 개발)

  • Lim, Jin-Taek;Lee, Sung-Hun;Lee, Yeon-Chan;Choi, Jae-Seok;Choi, Hong-Seok;Joo, Joon-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.10
    • /
    • pp.1328-1336
    • /
    • 2014
  • This paper proposes Power System Health Index(PSHI) newly. The paper describes several kind of power system health indices based on two main categories, which are adequacy and security. In adequacy, four kinds of health indices of Frequency, Voltage, Reserve(Operating Reserve Power and Frequency Regulation Reserve Power) and Overload of lines and transformers are proposed. In security, four kinds of health indices of Voltage(154kV, 345kV and 765kV), Overload of lines and transformers, Power flow constraint among areas and SPS are proposed. All indices are mapped with three domains, which are indicated as Health, Margin and Risk, defined with expert interview. While domains of health, margin and risk is defined similar with the conventional well being analysis of power system. The criterion of the domains is proposed using an interview with expert operators and practical reliability codes in Korea. The several kinds of health index functions, which are linear ratio, piecewise linear ration and reverse ratio function etc. are developed in this paper. It will be expected that the developed health indices can help operators to control power system more successfully and also prevent power system from accident as like as black out in future because operator can make a decision immediately based on more easily visual information of system conditions from too much indices acquisition of complex power system.

Considerations on the Propagation of Partial Discharge Pulse in 3-Phase Power Cable Systems including Cross-Bonding Joints (3상 전력케이블 크로스본딩 접속에서 부분방전 펄스 전파 특성 고찰)

  • Kim, Jeong-Tae;Kim, Dong-Uk;Kim, Ji-Hong
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1606-1607
    • /
    • 2011
  • In this study, the propagation characteristics of partial discharge(PD) pulses in the 3-phase cable systems including crossbonding joints were discussed. For the purpose, experiments for 22.9kV CNCV cables were performed using simulated PD pulses, and on-site partial discharge measurements were carried out for the 345kV XLPE cable system.

  • PDF

Seismic Reliability Assessment of the Korean 345 kV Electric Power Network considering Parallel Operation of Transformers (변압기의 병렬 운전을 고려한 국내 345kV 초고압 전력망의 지진 재해 신뢰성 평가)

  • Park, Won-Suk;Park, Young-Jun;Cho, Ho-Hyun;Koh, Hyun-Moo
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.10 no.3 s.49
    • /
    • pp.13-20
    • /
    • 2006
  • Substations in electric power transmission network systems (EPTS) operate using several transformers in parallel to increase the efficiency in terms of stability of energy supply. We present a seismic reliability assessment method of EPTS considering the parallel operation of transformers. Two methods for damage state model are compared in this paper: bi-state and multi-damage model. Simulation results showed that both models yielded similar network reliability indices and the reliability indices of the demand nodes using hi-state model exhibited higher damage probability. Particularly, the corresponding EENS (Expected Energy Not Supplied) index was significantly larger than that of the multi-damage state.

The Development of Dry-type Shunt Reactor for 345kV Substation Main Transformer (345kV 변전소 주변압기 3차측용 건식형 분로리액터 개발)

  • An, Y.H.;Park, J.B.;Song, T.S.;Han, B.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.497-500
    • /
    • 2001
  • Shunt reactors are used to compensate for capacitive VARs generated by lightly loaded transmission lines or underground cables. They are normally connected to the transformer tertiary winding. Dry-type shunt reactors have the advantage compared with oil-immersed shunt reactor as followings. Lower investment and maintenance cost, No fire hazard and no environmental concerns, Simple insulation to ground, Response to transient overvoltage less severe, Linearity of inductance versus load current, Lower-acoustic noise, Easier transport and handling due to lower weight, No oil-collecting system must be provided since there is no oil that can leak into the ground.

  • PDF

SCFL Application for Reducing Fault Current (고장전류 저감을 위한 초전도 한류기 적용)

  • Kim, Hak-Man;Kim, Jong-Yul;Choi, Sang-Bong;Moon, Young-Hwan;Sung, Ki-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.206-208
    • /
    • 2002
  • The transmission system is designed to be protected by 40 kA rate of circuit breaker fer 345 tV system and 31.5 kA and 50 kA rate of circuit breaker for 154 kV system. The short circuit current shows the tendency of exceeding circuit breaker duty for some substations and the tendency will continue if an appropriate countermeasure will not be applied to. In order to solve this problem from the viewpoint of system operation, the 154 kV system is under reconfiguration to be radial systems. This paper presents application effect of resistive and inductive SCFL (Superconducting Fault Current Limiter to Korea power systems. An algorithm of SCFL site decision is suggested.

  • PDF

Review of the Conceptual Design for the Use of HTS Power Transmission Cable for a Metropolitan Area

  • Park, Sang-Bong
    • KIEE International Transactions on Power Engineering
    • /
    • v.3A no.2
    • /
    • pp.63-69
    • /
    • 2003
  • The necessity of compact high temperature superconducting cables is more keenly felt in densely populated metropolitan areas. Because the compact high-temperature superconducting cables can be installed in ducts and tunnels, thereby reducing construction costs and making the use of underground space more effective, the effect of introducing it to the power system will be huge. Seoul, Korea, is selected as a review model for this paper. The loads are estimated by scenario based on a survey and analysis of 345kV and 154kV power supply networks in this area. Based on this, the following elements for an urban transmission system are examined. (1) A method of constructing a model system to introduce high-temperature superconducting cables to metropolitan areas is presented. (2) A case study is conducted through the analysis of power demand scenarios, and the amount of high-temperature superconducting cable to be introduced by scenario is examined. (3) The economy involved in expanding existing cables and introducing high-temperature superconducting cables(ducts or tunnels) following load increase in urban areas is examined and compared., and standards for current cable ducts are calculated. (4) The voltage level that can be accommodated by existing ducts is examined.

Patrol Monitoring Plan for Transmission Towers with a Commercial Drone and its Field Tests (상용화 드론을 이용한 송전선로 점검방안 및 현장시험)

  • Kim, Seok-Tae;Park, Joon-Young;Lee, Jae-Kyung;Ham, Ji-Wan;Choi, Min-Hee
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.4 no.2
    • /
    • pp.115-123
    • /
    • 2018
  • Various types of robots running on power transmission lines have been developed for the purpose of line patrol monitoring. They usually have complex mechanism to run and avoid obstacles on the power line, but nevertheless did not show satisfactory performance for going over the obstacles. Moreover, they were so heavy that they could not be easily installed on the lines. To compensate these problems, flying robots have been developed and recently, multi-copter drones with flight stability have been used in the electric power industry. The drones could be remotely controlled by human operators to monitor power distribution lines. In the case of transmission line patrol, however, transmission towers are huge and their spans are very long, and thus, it is very difficult for the pilot to control the patrol drones with the naked eye from a long distance away. This means that the risk of a drone crash onto electric power facilities always resides. In addition, there exists another danger of electromagnetic interference with the drones on autopilot waypoint tracking under ultra-high voltage environments. This paper presents a patrol monitoring plan of autopilot drones for power transmission lines and its field tests. First, the magnetic field effect on an autopilot patrol drone is investigated. Then, how to build the flight path to avoid the magnetic interference is proposed and our autopilot drone system is introduced. Finally, the effectiveness of the proposed patrol plan is confirmed through its field test results in the 154 kV, 345 kV and 765 kV transmission lines in Chungcheongnam-do.

The conception of conductor selection for KEPCO 765 kV T/L. (한전 765 KV 송전선로 전선선정 검토의 기본 방향)

  • Koo, B.M.;Oh, C.H.;Park, Y.S.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1505-1508
    • /
    • 1994
  • Lately in KEPCO, the power plant capacity has increasingly become larger than before and it has become difficult to get R.O.W for T/L. Therefore KEPCO decided to increase its system voltage level from 345kV to 765kV. By doing this, KEPCO would like to expand its transmission capability by less T/L route. In 765kV system, we should consider various kinds of environmental impacts that can be neglected in lower voltage level. These environmental impacts are very important factor in T/L design. That can be changed greatly according to the selected conductor. And also conductor selection has relation with the economy of T/L construction directly. This paper deals with some general factors to be considered and basic principles about the conductor and ground wire selection for 765KV T/L with referring to the experiences of foreign utilities.

  • PDF

Effect Analysis of PSS2A & IEEEST PSS of Power System in South Korea (PSS2A와 IEEEST PSS의 우리나라 계통에 대한 영향 분석)

  • Lee, Sang-Seung;Lee, Kang-Wan;Jang, Gwang-Soo;Park, Jong-Keun;Moon, Sung-Il;Yoon, Yong-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2004.11b
    • /
    • pp.194-197
    • /
    • 2004
  • 본 논문에서는 송전 계통사고 시 부하차단 이후 우리나라 2005년 계통에 대하여 전력계통안정화장치(Power System Stabilizer : PSS)의 영향 및 효과를 캐나다 Powertech Labs Inc.,의 TSAT(Transient Security Assesment Tool)을 이용하여 분석하였다. 모의를 위한 송전선로의 사고는 765kV 선로와 345kV 선로를 대상으로 하였으며, 8개의 모선에 대하여 상정 사고를 발생시켜 선로 차단 및 재투입을 고려하여 실시하였다. 본 연구에서 TSAT에 대한 기존의 전통적인 형태인 IEEEST type과 보다 정교한 이중구조를 가진 PSS2A type의 두 가지를 검토한 결과를 살펴보면 절반의 경우가 발전단 인근 지점의 사고시 발전기가 안정을 회복하지 못하고 탈조하는 것으로 나타났다. 그 외의 지역의 모선 단의 PSS투입효과는 비교적 댐핑 효과가 있는 것으로 나타났다.

  • PDF

On the Current Limiting Characteristics and Parameters of Superconducting Fault Current Limiter Introduced to 345kV Electric Power System due to Resistive-Type, Reactive-Type and Their Performance Comparison (유도형과 저항형 초전도한류기의 파라메타를 고려한 전력계통도입효과의 분석 및 성능평가에 관한 연구)

  • 홍원표;김용학
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.3
    • /
    • pp.74-83
    • /
    • 2002
  • The maximun short circuit current of modern power system is becoming so large that circuit breaker is not expected to be able to shut down the current in the future In order cut over-currents, a system composed of a superconducting fault current limiter(SFCL) and traditional breaker seems to provide a promising solution for furture power operation. In present paper, three line-to-ground fault is assumed to happen at the center of 345kV transmission lines in a large capacity electric power system. The superconducting fault current limiter was represented using a commutation type, which consists of a non-inductive superconducting coil and current limiting element (resistor or reactor). from the viewpoint of current limiting performance, the prevention of the voltage drop at the load bus and comparision characteristics for two type SFCL. Desired design specification and operation parameters of SECL were also given qualitatively by the performance.