• Title/Summary/Keyword: 33-모드

Search Result 289, Processing Time 0.023 seconds

A Thermal Performance Analysis on the Operation Modes of Radiant Floor Heating System Using SERI-RES (SERI-RES를 이용한 Radiant Floor Heating System의 열 성능 분석)

  • Chun, Won-Gee;Jeon, Myung-Seok;Auh, P.Chung-Moo
    • Solar Energy
    • /
    • v.11 no.2
    • /
    • pp.29-33
    • /
    • 1991
  • The present paper deals with two types of heating methods widely used for the Radiant Floor heating systems in Korea. Of these, one method circulates hot water according to the predefined schedule ("intermittent heating") while the other runs the system with the aid of thermostats ("continuous heating"). The standard version of SERI-RES has been modified for the numerical simulation of the problem. Preliminary results show relatively large temperature swings in the case of intermittent heating with solar availability. On the other hand, the case of continuous heating would avoid such undesirable temperature fluctuations. These results are also verified by experimental evaluations.

  • PDF

A New Mode Switching Control for Fast Settling and High Precision Positioning (고속 세틀링과 고정밀 위치 제어를 위한 모드 변경 제어 기법)

  • Kim, Jung-Jae;Choi, Young-Man;Kim, Ki-Hyun;Gweon, Dae-Gab;Hong, Dong-Pyo
    • Journal of the Semiconductor & Display Technology
    • /
    • v.5 no.4 s.17
    • /
    • pp.1-4
    • /
    • 2006
  • Recently, with rapid development of digital media like semiconductor and large flat panel display, the manufacturing equipment is required to have high precision over large travel range. Moreover it should have high product throughput. To achieve high product throughput, a controller should perform fast point-to-point motion and high precision positioning after settling in spite of external disturbances or residual vibrations. We proposed a new mode switching control algorithm with an application to dual stage for long range and high precision positioning. The proposed algorithm uses a proximate time-optimal servomechanism for the fast settling and a time-delay controller for the high precision positioning. Experimental results show that the proposed method enables smooth mode switching and improves the settling time and the precision accuracy after settling by over than 33% and 45%, respectively.

  • PDF

Design of a Digital Burst MODEM for High-Speed ATM Satellite Communications Part II : Performance Analysis of an Integrated Receiver (고속 ATM 위성통신을 위한 TDMA 버스트 모뎀 설계 II부 : 수신기 연동 성능평가)

  • Hwang, Sung-Hyun;Choi, Hyung-Jin
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.10
    • /
    • pp.27-33
    • /
    • 1998
  • In this paper, we designed a demodulator using proposed synchronization techniques and algorithms for high-speed ATM satellite burst modem, and analyzed various performance in the AWGN channel. In addition, as the preamble progressed, each synchronization process can be analyzed by using the mean and variance characteristics, and the convergence state and operation state using convergence probability can also be determined. In conclusion, we analyzed the Cell Loss Ratio(CLR) by integrating the burst acquisition with Unique Word(UW) detector performance, and verified that proposed TDMA receiver satisfied the generally required CLR performance adequately.

  • PDF

The Structural Design and Analysis of Spring Stabilizer for Aircraft Surveillance and Reconnaissance EO/IR Equipment (감시정찰 전자광학장비용 스프링 안정화 장치 구조 설계 및 해석 연구)

  • Yoonju Jung;Suhyeon Kim;Sanghyun Nam;Injae Park;Mingyun Park;Taekyun Kim;Hwanseok Yang;Seungwook Park;Seungha Lee
    • Journal of Aerospace System Engineering
    • /
    • v.17 no.5
    • /
    • pp.28-33
    • /
    • 2023
  • In this research, the isolator and the inner gimbal inside of typical EO/IR equipment were replaced with a spring stabilizer. This Spring stabilizer system revealed an internal platform capable of external vibration damping and 6-DOF driving. This system was designed based on machined springs and spring modules of the spring stabilizer, structure, and other fixture. Through modal vibration analysis, suitable material for the spring was determined. Structural stability of the spring stabilization device was determined through random vibration analysis.

Variability of Satellite-derived Chlorophyll-a Concentration in Relation to Indian Ocean Dipole (IOD) Variation (인도양 쌍극진동 변동에 따른 위성에서 추정된 표층 클로로필-a 농도 변화 연구)

  • Son, Young Baek;Kim, Suk Hyun;Kim, Sang-Hyun;Rho, TaeKeun
    • Korean Journal of Remote Sensing
    • /
    • v.33 no.6_1
    • /
    • pp.917-930
    • /
    • 2017
  • To understand the temporal and spatial variations of surface chlorophyll-a concentration (Chl-a) distribution in the Indian Ocean ($30^{\circ}E{\sim}120^{\circ}E$, $30^{\circ}S{\sim}30^{\circ}N$) by the Indian Ocean Dipole (IOD), we conducted EOF and K means analyses of monthly satellite-derived Chl-a data in the region during 1998~2016 periods. Chl-a showed low values in the central region of the Indian Ocean and relatively high values in the upwelling region and around the marginal regions of the Indian Ocean. It also had a strong seasonal variation of Chl-a, showing the lowest value in the spring and the highest value in summer due to the change of the monsoon and current system. The EOF analysis showed that Chl-a variation in EOF mode 1 is related to ENSO (El $Ni{\tilde{n}}o$/Southern Oscillation) and that of mode 2 is linked to IOD. Both modes explained spatially opposite trends of Chl-a in the east and west Indian Ocean. From K means analysis, the Chl-a variation in the east and west Indian Ocean, and around India have relatively good relationship with IOD while that in the tropical and middle Indian Ocean closely associated with ENSO. The spatial and temporal distribution of Chl-a also showed distinct spatial and temporal variations depend on the different types of IOD events. IOD classifies two patterns, which occurred during the developing ENSO (First Type IOD) and the year following ENSO event (Second Type IOD). Chl-a variation in the First Type IOD started in summer and peaked in fall around the east and west Indian Ocean. Chl-a variation in the Second Type IOD occurred started in spring, peaked in summer and fall, and disappeared in winter. In the Chl-a variation related to IOD, developing process appearing in the Chl-a difference between the east and west Indian ocean was similar. Chl-a variation in the northern Indian Ocean were opposite trend with changing developing phase of IOD.

A Study on Implementation and Performance of the Power Control High Power Amplifier for Satellite Mobile Communication System (위성통신용 전력제어 고출력증폭기의 구현 및 성능평가에 관한 연구)

  • 전중성;김동일;배정철
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.4 no.1
    • /
    • pp.77-88
    • /
    • 2000
  • In this paper, the 3-mode variable gain high power amplifier for a transmitter of INMARSAT-B operating at L-band(1626.5-1646.5 MHz) was developed. This SSPA can amplify 42 dBm in high power mode, 38 dBm in medium power mode and 36 dBm in low power mode for INMARSAT-B. The allowable errol sets +1 dBm as the upper limit and -2 dBm as the lower limit, respectively. To simplify the fabrication process, the whole system is designed by two parts composed of a driving amplifier and a high power amplifier. The HP's MGA-64135 and Motorola's MRF-6401 were used for driving amplifier, and the ERICSSON's PTE-10114 and PTF-10021 for the high power amplifier. The SSPA was fabricated by the RP circuits, the temperature compensation circuits and 3-mode variable gain control circuits and 20 dB parallel coupled-line directional coupler in aluminum housing. In addition, the gain control method was proposed by digital attenuator for 3-mode amplifier. Then il has been experimentally verified that the gain is controlled for single tone signal as well as two tone signals. In this case, the SSPA detects the output power by 20 dB parallel coupled-line directional coupler and phase non-splitter amplifier. The realized SSPA has 41.6 dB, 37.6 dB and 33.2 dB for small signal gain within 20 MHz bandwidth, and the VSWR of input and output port is less than 1.3:1. The minimum value of the 1 dB compression point gets more than 12 dBm for 3-mode variable gain high power amplifier. A typical two tone intermodulation point has 36.5 dBc maximum which is single carrier backed off 3 dB from 1 dB compression point. The maximum output power of 43 dBm was achieved at the 1636.5 MHz. These results reveal a high power of 20 Watt, which was the design target.

  • PDF

Analysis of Seismic Response of the Buried Pipeline with Pipe End Conditions (단부 경계조건을 고려한 매설관의 동적응답 해석)

  • Jeong Jin-Ho;Lee Byong-Gil;Jung Du-Hwoe;Park Byung-Ho
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.5
    • /
    • pp.33-43
    • /
    • 2005
  • This work reports results of our study on the dynamic responses of the buried pipelines both along the axial and the transverse directions under various boundary end conditions. In order to investigate the effect of the boundary end conditions for the dynamic responses of the buried pipeline, we have devised a computer program to find the solutions of the formulae on the dynamic responses (displacements, axial strains, and bending strains) under the various boundary end conditions considered in this study, The dynamic behavior of the buried pipelines for the forced vibration is found to exhibit two different forms, a transient response and a steady state response, depending on the time before and after the transfer of a seismic wave on the end of the buried pipeline. We have observed a resonance when the mode wavelength matches the wavelength of the seismic wave, where the mode number(k) of resonance f3r the axial direction. On the other hand, we have not been able to observe a resonance in the analysis of the transverse direction, because the dynamic responses are found to vanish after the seventh mode. From the results of the dynamic responses at many points of the pipeline, we have found that the responses appeared to be dependent critically on the boundary end conditions. Such effects are found to be most prominent especially for the maximum values of the displacement, the strain and its position.

Seismic Evaluation for Strainer in the Primary Cooling System (일차 냉각계통 스트레이너에 대한 내진 건전성 평가)

  • 정철섭
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.13 no.3
    • /
    • pp.295-304
    • /
    • 2000
  • To evaluate the structural integrity for the strainer under seismic loading the seismic analysis and design were performed for T-type strainer in accordance with ASME, Section Ⅲ, Class 3(ND). Since there are no specified design requirements for the strainer in ASME Code, the strainer body was analysed according to ND-3500, valve design. Flanged joints connected with PCS piping were designed according to ND-3658.3. And the criteria for the cover flange was governed by the Appendix XI. Both a frequency analysis and an equivalent static seismic analysis of the strainer were carried out using the finite element computer program, ANSYS. The frequency analysis results show the fundamental natural frequency is greater than 33Hz, thus justifying the use of the equivalent static analysis through which membrane and bending stresses are obtained in the critical points near the branch connection area. The results of the seismic evaluation fully satisfied with the structural acceptance criteria of the ASME Code. Accordingly the structural integrity on the strainer body and flanges were proved.

  • PDF

Power Factor Correction of Single-phase PWM Converter using Third Harmonic Injection (3차 고조파 주입에 의한 단상 PWM컨버터의 고역률 제어)

  • 손진근;유성식;김병진;박종찬;전희종
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.3
    • /
    • pp.25-33
    • /
    • 1999
  • In this paper, the method of reducing hanmnics and correcting of power factor in single PWM converter associated with diode rectifier and boost converter is studied. In the general diode rectifier there are sorre problems that discontinuous current of reducing power factor and including distortion of hanmnics at the input current affects other sources. To solve the problems of performance degradation due to pulse wavefonn in the input current, the ac-dc converter in which the hanmnic distortion in the input current is reduced using a third-hanmnic-injected PWM is proposed. A lower power loss of switching and easy configuration of circuit are obtained by adopting discontinuous current mode. Simulation and experimental results of ac-dc converter with 5[kHz] switching frequency are presented and correction of power factor and reduction of total hanmnic distortion was established.lished.

  • PDF

A Study of Mode II Interlaminar Fracture for CFRP Laminate Composite using the 4-point Bending CNF Specimen (4점굽힘 CNF 시험편을 이용한 CFRP적층 복합재 모드 II 층간파괴)

  • Kwon, Oh-Heon;Kang, Ji-Woong;Tae, Hwan-Jun;Hwang, Yeong-Yeun;Yun, Yu-Seung
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.3
    • /
    • pp.34-39
    • /
    • 2010
  • Unidirectional Carbon Fiber Reinforced Plastics (CFRP) are advanced materials which combine the characteristics of the light weight, high stiffness and strength. For those reasons, the use of the unidirectional CFRP has increased in jet fighters, aerospace structures. However, unidirectional CFRP composites have a lot of problems, especially delamination, compared with traditional materials such as steels and aluminums, and so forth. Therefore, the interlaminar fracture toughness for a laminate CFRP composite is very important. In this study, The mode II interlaminar fracture toughness was measured by using center notched flexure(CNF) test specimen. The CNF specimens using unidirectional carbon prepreg were fabricated by a hot-press with the gage pressure and temperature controller. And three kinds of a/L ratio was applied to these specimens. Here, we discuss the relations of the crack growth and the mode II interlaminar fracture under the four point bending CNF test. From the results, we shows that mode II interlaminar was occurred when the more $a_0$/L ratio, the less load. And $G_{IIC}$ also were obtained as 5.33, 2.9 and $0.58kJ/m^2$ according to $a_0$/L ratio=0.2, 0.3 and 0.4.