• Title/Summary/Keyword: 3-level modulation

Search Result 365, Processing Time 0.022 seconds

Neutral Point Voltage Control for Grid-Connected Three-Phase Three-Level Photovoltaic Inverter (계통연계형 3상 3레벨 태양광 인버터의 중성점 전압제어)

  • Park, Woonho;Yang, Oh
    • Journal of the Semiconductor & Display Technology
    • /
    • v.14 no.4
    • /
    • pp.72-77
    • /
    • 2015
  • Three-level diode clamped multilevel inverter, generally known as neutral point clamped (NPC) inverter, has an inherent problem causing neutral point (NP) potential variation. Until now, the NP potential problem of variation has been investigated and lots of solutions have also been proposed. This paper presents a neutral point voltage control technology using the anti-windup PI controller and offset technology of PWM (Pulse Width Modulation) to control the variation of NPC 3-phase three-level inverter neutral point voltage. And the proposed algorithm is tested and verified using a PLL (Phase Locked Loop) in order to synchronize the phase voltage from the line voltage of grid. It significantly improves the voltage balancing under a solar fluctuation conditions of the inverter. Experimental results show the good performance and effectiveness of the proposed method.

Development of Leakage Current Reduction Method in 3-Level Photovoltaic PCS (3레벨 태양광 PCS에서의 누설전류 저감기법 개발)

  • Han, Seongeun;Jo, Jongmin;An, Hyunsung;Cha, Hanju
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.1
    • /
    • pp.56-61
    • /
    • 2019
  • In this study, a reduction method of leakage current in a three-level photovoltaic power-conditioning system (PCS) is proposed and verified by simulation and experiment. Leakage current generation is analyzed through an equivalent model of the common mode voltage considering a significant parasitic capacitance existing between the photovoltaic array and ground. A leakage current reduction method using pulse-width modulation (PWM) method is also proposed, and a 10-kW three-level photovoltaic PCS simulation and experiment is performed with a $1{\mu}F$ parasitic capacitor based on 100 nF/kW. The proposed method using the PWM method is verified to reduce the leakage current by 73% compared with the conventional PWM method.

Performance of multi-level QAM transceiver with adaptive power control in fixed wireless channel

  • Lee, Seong-Choon;Lee, Yong-Hwan
    • Proceedings of the IEEK Conference
    • /
    • 2000.09a
    • /
    • pp.533-536
    • /
    • 2000
  • We consider the design of quadrature amplitude modulation (QAM) transceivers f3r fixed wireless communications. The use of adaptive power control in the transmitter (Tx) can provide BER performance robust to fading and improved BER performance. The BER performance is evaluated by analytical and simulation results when multi-level QAM transceiver employing power control in the Tx is applied to fixed wireless channel with flat fading and frequency selective fading. The effect of power control parameters such as power control range and power control step size is investigated

  • PDF

A study on performance enhancement of cyclic delay diversity OFDM system using frequency diversity (주파수 다이버시티를 이용한 순환 지연 다이버시티 OFDM 시스템의 성능 향상 연구)

  • Jung, Hyeok-Koo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.3A
    • /
    • pp.135-140
    • /
    • 2012
  • This paper proposes a technology for performance enhancement of cyclic delay diversity OFDM system using frequency diversity. The frequency diversity in an OFDM system can be done as repetitive transmission of the same symbol on uncorrelated subcarrier, this makes modulation level larger according to the number of repetitive transmission for the comparison with the traditional transmission system. This technique, like cyclic delay diversity, has a benefit which it does not need any special subsidiary hardware irrespective of the increase of the number of transmitter. For the performance comparison, we simulate the proposed algorithm in multiple input single out channel environment, it shows a better performance enhancement in low dense modulation level in comparison with the traditional cyclic delay diversity OFDM system.

Analysis and Control of NPC-3L Inverter Fed Dual Three-Phase PMSM Drives Considering their Asymmetric Factors

  • Chen, Jian;Wang, Zheng;Wang, Yibo;Cheng, Ming
    • Journal of Power Electronics
    • /
    • v.17 no.6
    • /
    • pp.1500-1511
    • /
    • 2017
  • The purpose of this paper is to study a high-performance control scheme for neutral-point-clamping three-level (NPC-3L) inverter fed dual three-phase permanent magnet synchronous motor (PMSM) drives by considering some asymmetric factors such as the non-identical parameters in phase windings. To implement this, the system model is analyzed for dual three-phase PMSM drives with asymmetric factors based on the vector space decomposition (VSD) principle. Based on the equivalent circuits, PI controllers with feedforward compensation are used in the d-q subspace for regulating torque, where the cut-off frequency of the PI controllers are set at the twice the fundamental frequency for compensating both the additional DC component and the second order component caused by asymmetry. Meanwhile, proportional resonant (PR) controllers are proposed in the x-y subspace for suppressing the possible unbalanced currents in the phase windings. A dual three-phase space vector modulation (DT-SVM) is designed for the drive, and the balancing factor is designed based on the numerical fitting surface for balancing the DC link capacitor voltages. Experimental results are given to demonstrate the validity of the theoretical analysis and the proposed control scheme.

A study on modulation technique for high efficiency of 3-phase 3-level T-type converter (3상 3 레벨 T-type 컨버터의 고 효율화를 위한 변조기법에 대한 연구)

  • Kim, TaeHun;Lee, WooCheol
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.264-266
    • /
    • 2018
  • 최근 환경문제로 인해 고효율의 전력 시스템의 중요성이 커지고 있다. 이에 따라 기존 2 레벨 컨버터에 비해 높은 효율을 갖는 3 레벨 컨버터의 사용이 증가하고 있다. 본 논문에서는 계통연계 형 3상 3 레벨 T-type 컨버터의 고 효율화를 위해 기존의 2 레벨, 3 레벨 동작을 비교 분석하고 효율을 개선할 수 있는 변조 기법을 제시한다.

  • PDF

Multi Output Hybrid Three level DC-DC Converter (하이브리드 3레벨 다출력 DC-DC 컨버터)

  • Kang, C.H;Lee, H.S;Ju, J.S;Malon, H.E;Kim, E.S;Lee, S.M;Kim, K.S
    • Proceedings of the KIPE Conference
    • /
    • 2014.11a
    • /
    • pp.9-10
    • /
    • 2014
  • 최근 신재생에너지 및 전기자동차, 통신 IT 서버 전원 및 가전기기 등의 발전에 따라 고 전력밀도(High Power Density), 고 응답(Fast Transient Response) 및 고정밀(Tight Regulation) 출력제어를 위한 다 출력 절연형 DC/DC 컨버터가 개발 및 연구되고 있다. 본 논문에서는 개별적인 정밀제어를 요구하는 다 출력 DC-DC 컨버터에 대한 내용으로 위상천이(Phase-shift) DC-DC 컨버터와 LLC 공진컨버터 제어개념을 하나의 주회로를 사용하여 위상천이제어(Phase-shifted Modulation, PM)와 가변주파수제어(Variable Frequency Modulation, FM)를 통해서 개별적으로 정밀 제어할 수 있는 하이브리드 다 출력 3레벨 DC-DC 컨버터에 관한 내용이다.

  • PDF

Acupuncture stimulation for motor cortex activities: Evidence from 3T functional MRI study

  • 최보영;전신수;유승식;최기순;박상동;임은철;정성택;이형구;서태석
    • Proceedings of the KSMRM Conference
    • /
    • 2003.10a
    • /
    • pp.85-85
    • /
    • 2003
  • Purpose: To investigate whether or not acupuncture of GB34 produces a significant response of the modulation of somatomotor areas by functional magnetic resonance imaging (fMRI) study. Materials and methods: The acupoint, GB34, located in the back of the knee, is known to be effective in recovering motor function after stroke. Using 3T MRI scanner, functional MR imaging of the whole brain was peformed in 12 normal healthy subjects during two stimulation paradigms; acupuncture manipulation on GB34 and sham points. This study investigates the activation of the motor cortex elicited by a soft and an intensified stimulation of GB 34.Three different paradigms were carried out to detect any possible modulation of the Blood Oxygenation Level Dependent (BOLD) response in the somatomortor area to motor stimulation through acupuncture.

  • PDF

Carrier Based LFCPWM for Leakage Current Reduction and NP Current Control in 3-Phase 3-Level Converter (3상 3-레벨 컨버터의 누설전류 저감과 NP 전류 제어를 위한 캐리어 기반 LFCPWM)

  • Lee, Eun-Chul;Choi, Nam-Sup
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.5
    • /
    • pp.446-454
    • /
    • 2022
  • This study proposes a carrier-based pulse width modulation (PWM) method for leakage current reduction and neutral point (NP) current control in a three-phase three-level converter, which is a carrier-based PWM version of the previously proposed low-frequency common mode voltage PWM. Three groups of space vectors with the same common mode voltage are used. When the averaged NP current needs to be positive or negative, the specific groups are employed to produce low-frequency common mode voltages. The validity of the proposed PWM method is verified through experiments.

Development of Small-sized SQUID and Direct-coupled Electronics for High-$T_c$ Scanning SQUID Microscope (소형 SQUID, 직접 되먹임 방식 전자회로, 고온초전도 SQUID 주사현미경의 개량)

  • Baek, B.;Lee, S. M;Yun, J. H.;Khim, Z. G.
    • Progress in Superconductivity
    • /
    • v.3 no.1
    • /
    • pp.78-82
    • /
    • 2001
  • The spatial resolution of $high-T_{c}$ scanning SQUID microscope is limited by the washer size of SQUID and the gap distance between SQUID sensor and the sample. In this work, we tried to improve the spatial resolution of scanning SQUID microscope by reducing the size of SQUID sensor fabricated with $YBa_2$$Cu_3$$O_{7}$ thin film. Outer dimensions of the SQUiDs we tested are 24 $\mu\textrm{m}$ $\times$ $ 28\mu\textrm{m}$, $12 \mu\textrm{m}$ $\times$ $16\mu\textrm{m}$, $12\mu\textrm{m}$ x $12\mu\textrm{m}$, $10 \mu\textrm{m}$ $\times$ $10 \mu\textrm{m}$ each. To operate them in the flux-locked loop scheme, we used a direct-coupled electronics instead of using conventional electronics involving a modulation scheme. Since the direct-coupled feedback scheme does not require modulation current adjustment that poses as a practical difficulty in the SQUID operation in modulation-scheme, the direct feedback operation is rather simpler than the conventional modulation method. The resulting noise features were dominated by the noise of preamp in FLL electronics except that of the largest SQUID. The noise levels of SQUIDs are expected below 1$\times$$10^{-5}$ $\Phi_{0}$H $z^{1}$2/ (at 300 Hz), that is a typical noise level for SQUID made of $YBa_2$C $u_3$$O_{7}$ thin film. The data acquisition and motion-controlling parts were also improved, resulting in faster data acquisition rate and less vibration of the system.m.

  • PDF