• Title/Summary/Keyword: 3-cut

Search Result 4,071, Processing Time 0.041 seconds

INFLUENCES OF APICOECTOMY AND RETROGRADE CAVITY PREPARATION METHODS ON THE APICAL LEAKAGE (치근단절제 및 역충전와동 형성방법이 치근단누출에 미치는 영향)

  • Yang, Jeong-Ok;Kim, Sung-Kyo;Kwon, Tae-Kyung
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.2
    • /
    • pp.537-549
    • /
    • 1998
  • The purpose of this study was to evaluate the influence of root resection and retrograde cavity preparation methods on the apical leakage in endodontic surgery. To investigate the effect of various root resection and retrograde cavity preparation methods on the apical leakage, 71 roots of extracted human maxillary anterior teeth and 44 mesiobuccal roots of extracted human maxillary first molars were used. Root canals of the all the specimens were prepared with step-back technique and filled with gutta-percha by lateral condensation method. Three millimeters of each root was resected at a 45 degree angle or perpendicular to the long axis of the tooth according to the groups. Retrograde cavities were prepared with ultrasonic instruments or a slow-speed round bur, and occlusal access cavities were filled with zinc oxide eugenol cement. Three coats of clear nail polish were placed on the lateral and coronal surfaces of the specimens except the apical cut one millimeter. All the specimens were immerged in 2% methylene blue solution for 7 days in an incubator at $37^{\circ}C$. The teeth were dissolved in 14 ml of 35% nitric acid solution and the dye present within the root canal system was returned to solution. The leakage of dye was quantitatively measured via spectrophotometric method. The obtained data were analysed statistically using two-way ANOVA and Duncans Multiple Range Test. The results were as follows: 1. No statistically significant difference was observed between ultrasonic retrograde cavity preparation method and slow-speed round bur technique, without apical bevel (p>0.05). 2. Ultrasonic retrograde preparation method showed significantly less apical leakage than slow-speed round bur technique, with bevel (p<0.0001). 3. No statistically significant difference was found between beveled resected root surface and non-beveled resected root surface, with ultrasonic technique (p>0.05). 4. Non-beveled resected root surface showed significantly less apical leakage than beveled resected root surface, with slow-speed round bur technique (p<0.0001). 5. No statistically significant difference in apical leakage was found between the group of retrograde cavity prepared parallel to the long axis of the tooth and the group of one prepared perpendicular to the long axis of the tooth (p>0.05). 6. Regarding isthmus preparation, ultrasonic retrograde preparation method showed significantly less apical leakage than slow-speed round bur technique, in the mesiobuccal root of maxillary molar, without bevel (p<0.0001).

  • PDF

A Study on the Reflective Property of Trends in Fashion Shows - Focused on Three Designing Factor of the Silhouette, the Detail, the Color and the Fashion Image - (패션쇼의 트렌드 반영성(反映性)에 관(關)한 연구(硏究) - 실루엣, 디테일, 색상(色相), 패션 이미지 등(等) 4가지 디자인 요소(要素)를 중심(中心)으로 -)

  • Lee, Myung-Hee
    • Journal of Fashion Business
    • /
    • v.3 no.4
    • /
    • pp.147-160
    • /
    • 1999
  • This paper is intended to compare and analyze the fashion trends that were introduced in the recent shows, held abroad and in Korea, so as to investigate how well the designers in Taegu and Kyungbuk (TK) area are keeping up with the international vogue. The research has done, analyzing Pret-a-Porter in Paris and the three events held in the TK area in 1997 -The Taegu Collection, Kyungbuk Fashion Festival and Textile & Apparel Fair and using reference pictures and documentary records. In order to investigate the trends the research is divided by four groups which are the silhouette, the detail, the color and the Fashion image and has done with the help of three postgraduate students. The results are as follows. 1. The Silhouette The slim-line has the greatest importance in the silhouette analysis of the recent collections. Like Elongated and Fit & Flare, tight-fitting and female-line were also appeared quite a lot. Compared with foreign collection, Korean collections put the bigger importance on the slim-line. 2. The Detail The printings, using paintings and plant-logos had the large portion of the accessories in both foreign and Korean collections. Draw string and wrap style were also presented a lot. Especially, at the Korean collections, layerd, corsage, and craft accent were emphasized, too. As for the necklines the similarity was found over the four events considering. Camisole neckline and halter neck were presented the most, and bared top, Vneckline, boat and low-neck which can highlight the feminity were often appeared as well. Considering collars, tailored and peaked collars which are frequently used for the jackets, were usually shown at the collections. Like convertable, shirts, wing and Italian collar, the collars that can be applied for the sports wears were presented a lot. Virtually no variation of design was found in the sleeve analysis. While set-in-sleeve and sleeveless were found commonly, not so many ornaments were added to the sleeves. The ankle and knee length for the pants and skirts were common. Furthermore, including the micro-mini, showing extremely feminine style the mini-style had the 20% portion of the skirt-length. Unbalanced lengths, using bias-cut were presented quite a lot on the runways. Deep slit skirts, wide pants and irregular hem skirts were in vogue. On the runways of Paris, more than 21% of the design was the burmuda pants. 3. The Color Red and Blue were in vogue in the four collections considering. Sometimes, yellowish was combined in Korean collections. Black and pale tone were appeared to be in fashion also with light grayish, moderate and deep tone. 4. The Fashion image As for the fashion image, feminine-decorative trend amounted to the large percentage in korean collections. At the foreign collection feminine-decorative trend and feminine trend were predominant, then mannish trend and simple trend were apeared equally. The research shows that TK area and foreign collections are fairy similar, which means that the designers in TK area have been making their efforts to satisfy the clients who have the international minds. However, compared with foreign collections, TK collections were apprered to be strongly inclined to only a few trends. Consequently the season trends are not as diverse as the foreign trends, which cannot satisfy the fashion taste of the clients in TK area. The local designers should know the tendency and the taste of the clients and make the more efforts to read local clients' mind.

  • PDF

The Usefulness of the Berlin Questionnaire as a Screening for Obstructive Sleep Apnea in a Sleep Clinic Population (수면 클리닉을 내원한 환자에서 폐쇄성수면무호흡의 선별을 위한 베를린 설문의 유용성)

  • Kang, Hyeon-Hui;Kang, Ji-Young;Lee, Sang-Haak;Moon, Hwa-Sik
    • Sleep Medicine and Psychophysiology
    • /
    • v.18 no.2
    • /
    • pp.82-86
    • /
    • 2011
  • Objectives: The Berlin Questionnaire (BQ) has been used to help identify patients at high risk of having sleep apnea in primary care. But it has not been validated in a sleep clinic for Korean patients. The aim of this study is to evaluate the usefulness of the BQ as a screening tool for obstructive sleep apnea (OSA) for Korean patients in a sleep clinic. Methods: The BQ was prospectively applied to 121 subjects with OSA suspicion who visited to our sleep clinic. All subjects performed overnight polysomnography. OSA was defined as an apnea-hypopnea index (AHI) ${\geq}5$. We investigated the sensitivity, specificity, positive and negative predictive values of the BQ according to severity by AHI. Results: In 121 subjects, 73.6% were males, with a mean age of $48.8{\pm}13.0$ years. Twenty-five (20.6%) patients did not have OSA (AHI<5), 30 (25%) patients had mild OSA ($AHI{\geq}5$ and <15), 26 (21.4%) had moderate ($AHI{\geq}15$ and <30), and 40 (33%) had severe OSA ($AHI{\geq}30$). The BQ identified 69.4% of the patients as being at high risk for having OSA. The sensitivity and specificity of the BQ were 71.9% and 40%, for $AHI{\geq}5$, 75.8% and 38.2% for $AHI{\geq}15$, 77.5% and 34.6% for $AHI{\geq}30$, respectively. The positive and negative predictive values of the BQ were 82.1% and 27.0% for $AHI{\geq}5$, respectively. Positive and negative likelihood ratios were 1.2 and 0.7, and the overall diagnostic accuracy of the BQ was 65.3%, using an AHI cut-off of 5. Conclusion: Due to modest sensitivity and low specificity, the BQ does not seem to be an appropriate tool for identifying patients with obstructive sleep apnea in a sleep clinic population.

A LIGHT AND ELECTRON MICROSCOPIC STUDY OF CHANCES IN INTERMAXILLARY SUTURE DURING THE RAPID MAXILLARY EXPANSION OF YOUNG ADULT DOGS (유성견 급속정중이개시 정중구개봉합부위의 조직학적 변화에 대한 연구)

  • Lee, Doo-Hee;Chung, Kyu-Rhim
    • The korean journal of orthodontics
    • /
    • v.26 no.2 s.55
    • /
    • pp.153-162
    • /
    • 1996
  • Rapid maxillary expansion is widely used for the correction of anteroposterior discrepancies, constriction of the maxillary arch, etc. This experiment was undertaken to examine the serial changes in the osteogenesis as well as the collagen fiber bundles in the intermaxillary suture during the rapid maxillary expansion treatment. Four young female dogs aged 6 to 8 months old and not showing menarche yet were used for the experiment. The maxillary impression of dogs were taken, expansion device cast and Hyrax screw soldered at the midline in the 1st premolar area. RME device was delivered to the dogs and the activation of 0.25 mm per quarter-turn was done 2 times per day for 10 days until 5 mm separation was made. Separation of the maxilla was confirmed by X-ray. The animals were sacrificed on 0, 15, 30, 60 days from the finish of maxillary separation and preparations for light microscopy and surface electron microscopy were made. The sutures were cut into frontal serial sections for examination of the histological reactions. The following results were obtained and the conclusions made. 1. The edges of the two palatal plates bordering the midpalatal suture which at the beginning of the retention period were mainly composed of compact bone, underwent extensive resorption followed by new bone formation and gradually became spongy bone rich in bone marrow which in the 60 day retention animal became the compact bone with short intermaxillary suture space. During this transformation, newly formed trabecular bone tissues were added to the original margin. 2. Throughout the expansion period, the collagen fibers underwent successive changes such as stretching, loss of polarity, and finally fibrillogenesis. Towards the end of the expansion procedure, sharpey's fiber formation in newly formed bones were observed. 3. Bony spicules were found in the initial stage of retention on occlusal topographic X-rays, which later were confirmed to have ossified. 4. Judging from the histological changes occuring during the experimental expansion, excessive expansion will cause an excessive bleeding, and retard the remodeling of intermaxillary suture. According to the above results, the bone remodeling after rapid maxillary expansion was preceded by the migration of migratory cells into the intermaxillary suture area. The bone remodeling phenomena were on-going during the 2 months retention sample.

  • PDF

Tensile Bond Strength of Composite Resin Treated with Er:YAG Laser (Er:YAG 레이저를 활용한 와동형성시 컴포짓 결합강도)

  • Shin, Min;Ji, Young-Duk;Rhu, Sung-Ho;Cho, Jin-Hyoung
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.2
    • /
    • pp.269-276
    • /
    • 2005
  • This in vitro study evaluated the influence of a flowable composite resin on the tensile bond strength of resin to enamel and dentin treated with Er:YAG laser and diamond bur. 96 Buccal enamel and mid-coronal dentin were laser-irradiated using an Er:YAG laser and treated with diamond bur. Each groups(48) were divided two small groups depends on acid-etching procedure. Light-cure flowable resin(Metafil Flo) and self-cure resin(Clearfil FII New Bond) were used in this study. After surface etching with 37% phosphoric acid and the application of an adhesive system, specimens were prepared with a hybrid composite resin. After 24hours storage in distilled water at 37$^{\circ}C$, all samples were submitted to the tensile bond strength evaluation, using a universal testing machine(Z020, Zwick, Germany). The obtained results were as follows: 1. TBS of acid-etching group were higher than those of non-etching group in both enamel and dentin treated with Er:YAG laser and diamond bur. Laser 'conditioning' was clearly less effective than acid-etching. Moreover, acid etching lased enamel and dentin significantly improved the microTBS of M-Flo. 2. In enamel, TBS of laser-irradiated group were lower than those of bur-prepared group. However, in flowable resin subgroup, there were not differed those between two groups in dentin. 3. In laser-treated group, TBS of flowable composite resin were higher than those of self-curing resin in dentin, however, there was no difference in enamel. From this study, we can conclude that the self- and light-cure composite resin bonded significantly less effective to lased than to bur-cut enamel and dentin, and that acid-etch procedure remains mandatory even after laser ablation. We suggest that Er:YAG laser was useful for preparing dentin cavity with flowable resin filling.

MIMIC 94 GHz high isolation single balanced cascode mixer (94 GHz 대역의 높은 격리 특성의 MIMIC single balanced cascode 믹서)

  • Lee, Sang-Jin;An, Dan;Lee, Mun-Kyo;Moon, Sung-Woon;Bang, Suk-Ho;Baek, Tae-Jong;Kwon, Hyuk-Ja;Jun, Byoung-Chul;Yoon, Jin-Seob;Rhee, Jin-Koo
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.9
    • /
    • pp.25-33
    • /
    • 2007
  • In this paper, the high isolation and wideband 94 GHz MIMIC(Millimeter-wave Monolithic Integrated Circuit) single balanced cascode mixer was designed and fabricated. Also, we designed and fabricated a 3 dB tandem coupler which has a high isolation and wideband characteristic. The single balanced resistive mixer which does not require an external IF balun was designed using the 0.1 ${\mu}m$ InGaAs/InAlAs/GaAs metamorphic HEMT(High Electron Mobility Transistor). The DC characteristics of MHEMT's are 665 mA/mm of drain current density, 691 mS/mm of maximum transconductance. The current gain cut-off frequency($f_T$) is 189 GHz and the maximum oscillation frequency($f_{max}$) is 334 GHz. A 94 GHz single balanced cascode mixer was fabricated using our 0.1 ${\mu}m$ MHEMT MIMIC process. From the measurements, the fabricated couplers showed wideband characteristics. The conversion loss of single balanced cascode mixer was 9.8 dB at an LO power of 10.9 dBm. The LO to RF isolation of single balanced cascode mixer was 29.5 dB at 94 GHz. We obtained in this study a higher LO-RF isolation compared to some other single balanced mixers.

Clinical significance of CA125 level in tuberculous pneumonia (결핵성 폐렴에서의 CA125측정의 임상적 의의)

  • Choi, Soo-Jeon;Kim, Young-Ho;Yum, Ho-Kee;Kim, Ju-In;Lee, Bong-Choon;Kim, Jeong-Sook
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.2
    • /
    • pp.159-163
    • /
    • 1996
  • Background : In case of tuberculous pneumonia, differentiation from bacterial lobar pneumonia is sometimes very difficult because clinical symptoms, signs and radiological images are very similar. So we investigated the usefulness of CA125, which is known to increase in tuberculous diseases, in differential diagnosis between tuberculous pneumonia (TBPN) and community acquired bacterial lobar pneumonia (LP). Methods : Serum CA125 level was measured in 20 patients with TBPN (female 12 male 8 : mean age 36.1 years) and 14 patients with LP (female 5 male 9 : mean age 45.1 years) by radioimmunoassay (Centocor(R) CA125 RIA kit). Results : 1) The serum CA125 level in TBPN ($333.7{\pm}283.5\;u/ml$) was higher than in LP ($60.9{\pm}66.2\;u/ml$). (P < 0.05) 2) If we took cut-off value as 195 u/ml in differential diagnosis between TBPN and LP, the sensitivity and specificity of CA125 level in the diagnosis of TBPN were 70% and 93%, respectively. 3) There was no significant difference in serum CA125 level between noncavitary TBPN ($242.1{\pm}76.6\;u/ml$, n=10) and cavitary TBPN ($399.6{\pm}318.4\;u/ml$, n=10). (P > 0.05) 4) Following up of serum CA125 level after initiation of antituberculosis treatment showed rapid decline and approach to near normal range in 6 months. Conclusion : High serum CA125 level (> 195 u/ml) was useful in differential diagnosis of TBPN from LP.

  • PDF

Analysis of thermal changes in bone by various insertion torques with different implant designs (서로 다른 형태의 임플란트의 식립토크가 골에 미치는 열변화에 관한 연구)

  • Kim, Min-Ho;Yeo, In-Sung;Kim, Sung-Hun;Han, Jung-Seok;Lee, Jai-Bong;Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.2
    • /
    • pp.168-176
    • /
    • 2011
  • Purpose: This study aims at investigating the influence of various insertion torques on thermal changes of bone. A proper insertion torque is derived based on the thermal analysis with two different implant designs. Materials and methods: For implant materials, bovine scapula bone of 15 - 20 mm thickness was cut into 35 mm by 40 - 50 mm pieces. Of these, the pieces having 2 - 3 mm thickness cortical bone were used as samples. Then, the half of the sample was immersed in a bath of $36.5^{\circ}C$ and the other half was exposed to ambient temperature of $25^{\circ}C$, so that the inner and surface temperatures reached $36.5^{\circ}C$ and $28^{\circ}C$, respectively. Two types of implants ($4.5{\times}10\;mm$ Br${\aa}$nemark type, $4.8{\times}10\;mm$ Microthread type) were inserted into bovine scapula bone and the temperature was measured by a thermocouple at 0.2 mm from the measuring point. Finite element method (FEM) was used to analyze the thermal changes at contacting surface assuming that the sample is a cube of $4\;cm{\times}4\;cm{\times}2\;cm$ and a layer up to 2 mm from the top is cortical bone and below is a cancellous bone. Boundary conditions were set on the basis of the shape of cavity after implants. SolidWorks was used as a CAD program with the help of Abaqus 6.9-1. Results: In the in-vitro experiment, the Microhead type implant gives a higher maximum temperature than that of the Br${\aa}$nemark type, which is attributed to high frictional heat that is associated with the implant shape. In both types, an Eriksson threshold was observed at torques of 50 Ncm (Br${\aa}$nemark) and 35 Ncm (Microthread type), respectively. Based on these findings, the Microthread type implant is more affected by insertion torques. Conclusion: This study demonstrate that a proper choice of insertion torque is important when using a specific type of implant. In particular, for the Microthread type implant, possible bone damage may be expected as a result of frictional heat, which compensates for initial high success rate of fixation. Therefore, the insertion torque should be adjusted for each implant design. Furthermore, the operation skills should be carefully chosen for each implant type and insertion torque.

A Characteristics of Maintenance Planning of Trees in Historical Landscape Forest of Royal Tombs of the Joseon Dynasty (조선왕릉 역사경관림 수목 정비 계획의 특성)

  • So, Hyun-Su;Lee, Jong-Keun
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.36 no.3
    • /
    • pp.88-99
    • /
    • 2018
  • After UNESCO appointed Royal Tombs of the Joseon Dynasty to be World Cultural Heritages(2009), Cultural Heritage Administration in Korea established Management Office of Royal Tombs of the Joseon Dynasty(2012) and conducted Mid to Long-Term Plan on Conservation, Management, Utilization of World Heritage 'Royal Tombs of the Joseon Dynasty(2015)'. The report, as an implementation plan, provides detailed contents of the maintenance planning of Royal Tombs of the Joseon Dynasty. From this background, with a view to comprehending the characteristics of the maintenance planning of trees in historical landscape forests, this study extracted the contents related to the historical landscape forests of the 40 Royal Tombs of the Joseon Dynasty from the "Mid to Long-term Plan" and conducted literature research. The results of the study are as follows. First, from 2016, the short-term plans have provided detailed contents on logging, transplanting and planting trees in the plans divided by stages. On the other hand, the long-term plans, instead of presenting abstract contents repeatedly for each royal tomb, should seek vegetation landscape that each royal tomb should aim for. Second, since the areas that are in charge of the various functions of the royal tombs have been subjects to the maintenance planning, it is effective to establish a maintenance planning by separating functional areas instead of the comprehensive concept as historical landscape forests. Third, the maintenance planning of trees in historical landscape forest of the Royal Tombs of Joseon Dynasty is based on daily management such as density control and maintaining the shape of trees, which is necessary to sustain the forest. Also, due to the goal of preserving the pine forest, which is recognized as a prototype vegetation landscape, foreign species and other trees have been more cut down. With a few limited types of tall tree but few shrubs and flowers, it is characterized that the orientation toward aesthetic landscapes is insufficient in large green spaces. Fourth, according to the function of the tomb, it is divided into entrance area, ceremonial area, burial area and outer forest, and the contents of the maintenance planning are analyzed by basic conditions of tree management: prototype, ecology, functionality, and aesthetics. After studying the tree management characteristics of each area, four suggestions are made: understanding the diversity of trees that form prototype landscape as a management plan, sustainability of various forests adapted to ecological environment, convenience required in addition to ceremony and safety characterizing the Royal Tombs of Joseon Dynasty, and the necessity of access to aesthetic landscape on the tombs.

An Experimental Study on Evaluation of Axially Compressive Buckling Strength of Corroded Temporary Steel (부식 손상된 가시설 강재의 축압축 좌굴강도 추정에 관한 실험적 연구)

  • Kim, In Tae;Lee, Myoung Jin;Shin, Chang Hee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.6
    • /
    • pp.135-146
    • /
    • 2011
  • Steel structures have been generally painted to prevent corrosion damage. However, the painted film is deteriorated with increase in service life, and then corrosion damage resulting in cross sectional area occurs on steel surface. As a result, the buckling strength of steel structures can be decreased due to the corrosion damages. The evaluation method of the axial buckling strength of columns about a variety of section shapes and supporting conditions have been presented, but evaluation method of buckling strength about irregular nonprismatic columns is not established. In this study, the axial buckling strength of corroded steels was evaluated based on the buckling test results of corroded steel specimens that were cut off at a temporary steel structure. The corroded specimens were picked up total 10 specimens according to various slenderness ratio from the web of a temporary structure's main beam. The length of specimens is 200, 300, 400, 500 and 600mm respectively. The rust productions were removed by the chemical treatment. Then, the surface geometry was measured at intervals of $1{\times}1mm$ by using the optical 3D digitizing system, and the residual thickness of the specimens was calculated. The axial buckling test was performed on 10 corroded specimens and 12 non-corroded specimens under the fixed-fixed support condition. From the test results, the effect of corrosion damages on axial buckling load was investigated. Regardless of corrosion damage degree, the axial buckling strength of corroded specimens and non-corroded specimens was evaluated identically by using minimum average residual thickness or average residual thickness to minus its standard deviation. Reasonable measuring intervals of residual thickness was proposed by using the results to apply for practical works.