• Title/Summary/Keyword: 3-Dimensional Measuring Machine

Search Result 79, Processing Time 0.025 seconds

A study on Net-shape technology of Automotive Lock-up Hub using Cold back pressure forming (배압 성형기술을 이용한 Lock-up Hub의 정형제조 기술에 관한 연구)

  • Kwon, Y.C.;Lee, J.H.;Lee, Y.S.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2007.10a
    • /
    • pp.173-176
    • /
    • 2007
  • The characteristics of the tool system give many effects into the costs and qualities for the finished components. This study proposes a new method for manufacturing of high manufacturing productivity, production process reduction and low cost through back pressure forming. The Lock-up hub is manufactured through many processes, such as upsetting($1^{st}$ Forming), piercing, direct extrusion($2^{nd}$ Forming), final sizing process($3^{rd}$ Forming). In this study, process design for closed-die forging of a Lock-up hub used for a component of automobile transmission was made using three-dimensional finite element simulations, and the strain distributions and velocity distributions are investigated through the post processor. The rigid-plastic finite-element method for back pressure forging has been used in order to reduce development time and die cost. Using the FEM simulation, we found the optimum value of back pressure. The prototypes of Lock-up hub parts were forged into the net-shape. In the experiment, lead precision of tooth are measured by the CCMM(Contact Coordinate Measuring Machine). The dimensional accuracy of forged part was improved up to the 40% when back press was applied.

  • PDF

Development of a CAD/CAM System for the Die Having Complex Geometric Solid Shape - for Rotary Blade as an Example - (자유곡면물체(自由曲面物體)의 금형설계(金型設計) 및 제작(製作)의 자동화(自動化)를 위한 CAD/DAM - 로우터리 경운(耕耘)날을 중심(中心)으로 -)

  • Kim, Soung Rai;Kim, Ki Dae
    • Korean Journal of Agricultural Science
    • /
    • v.22 no.1
    • /
    • pp.11-23
    • /
    • 1995
  • The CAD/CAM system for the manufacturing automation is the newest technology in mechanical engineering area and becomes the important research subject nowadays. Most of all hardwares and softwares for the CAD/CAM system used in the our manufacturing companies such as automobile company are developed by the foreign country and the purchasing price of them is very expensive but their applicability to a certain area is very limited. This study was conducted to develope a CAD/CAM system for the design and the automatic manufacturing of the iron pattern shaped with 3 - dimensional free curved surface, and to test its applicability to the design and the manufacturing of the rotary blade. The results obtained from the study are as follow; 1. The CAD system which can process graphic procedures from the free curved surface shaped data was developed with personal computer. 2. The CAM main program was developed. This main program could produce CL data from CAD data file by checking the tool interference according to the cutting mode. 3. The sub. program which can simulate the tool trace from the CL data was developed. 4. The post processor for the Deckel FP2NC NC milling machine from CL data file was developed and the sub program could transmit NC program through modem to NC milling machine was developed. 5. The developed CAM system seemed to be applicable to any other system. Because the measuring results of the cross sectional thickness of the plastic model from the manufacturing iron pattern by the system showed that this system could properly check the tool interference. 6. In took 75~90 hours to manufacture two iron patterns of rotary blade. For the sake of convenience in applying to the other systems, this system was developed in BASIC and FORTRAN computer language and minimum portion of machine language as possible.

  • PDF

THE DIMENSIONAL CHANGE OF CAST IMPLANT BARS AFTER LABORATORY PROCEDURE

  • Kwon, Ji-Yung;Kim, Chang-Whe;Lim, Young-Jun;Kim, Myung-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.3
    • /
    • pp.354-361
    • /
    • 2007
  • Statement of Problems. The precision of fit between the bearing surfaces of implant abutments and the prosthesis framework has been considered fundamental to implant prosthodontic protocol. Purpose. The study aimed to investigate the effect of laboratory procedure on the dimensional accuracy of cast implant bars. Material and methods Thirty implant bars were fabricated on a metal master model. The gap distances were measured at the right implant abutment replica-gold cylinder interface after casting procedure. The bar length data of precasting and postcasting state were collected and analyzed. Results. The mean gap distance found after casting was $106.3{\mu}m$ for buccal side, $122.1{\mu}m$ for distal side and $117.1{\mu}m$ for the lingual side. The mean bar length was $17964.7{\mu}m$ at precasting measurement, $17891.6{\mu}m$ at postcasting measurement. The mean change of bar length was $-73.1{\mu}m$. Conclusion. Even though the techniques used in this study strictly followed the guidelines established in the literature, the 30 cast implant bars evaluated all yielded gap distances that were beyond acceptable accuracy. There was a statistically significant difference between precasting and postcasting bar length (P<0.01). There was a decreasing tendency in bar length after casting procedure. It was necessary to correct this dimensional change from laboratory procedure by some corrective methods.

2D/3D Visual Optical Inspection System for Quad Chip (Quad Chip 외관 불량 검사를 위한 2D/3D 광학 시스템)

  • Han, Chang Ho;Lee, Sangjoon;Park, Chul-Geon;Lee, Ji Yeon;Ryu, Young-Kee;Ko, Kuk Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.1
    • /
    • pp.684-692
    • /
    • 2016
  • In the manufacturing process of the LQFP/TQFP (Low-profile Quad Flat Package/Thin Quad Flat Package), the requirement of a 3 dimensional inspection is increasing rapidly and a 3D inspection of the shape of a chip has become an important report of quality control. This study developed a 3 dimensional measurement system based on PMP (Phase Measuring Profilometry) for an inspection of the LQFP/TQFP chip and image processing algorithms. The defects of the LQFP/TQFP chip were classified according to the dimensions. The 2 dimensional optical system was designed by the dorm illumination to achieve constant light distribution, In the 3 dimensional optical system, PZT was used for moving 90 degree in phase. The problem of 2 ambiguity was solved from the measured moir? pattern using the ambiguity elimination algorithm that finds the point of ambiguity and refines the phase value. The proposed 3D measurement system was evaluated experimentally.

THE STUDY ABOUT THE MARGINAL FIT OF THE CASTING TITANIUM AND MACHINE-MILLED TITANIUM COPINGS (주조티타늄과 기계절삭티타늄 코핑의 변연적합성에 관한 연구)

  • Oh Su-Yeon;Vang Mong-Sook;Yang Hong-So;Park Sang-Won;Park Ha-Ok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.1
    • /
    • pp.20-28
    • /
    • 2006
  • Statement of problem: The titanium has advantages of a high biocompatibility, a corrosion resistence, low density, and cheep price, so it is focused as a substituted alloy But it is quite difficult to cast with the tranditional method due to the high melting point, reacivity with element at, elevated temperature. By using the CAD-CAM system for the crown construction, it is possible to reduce the errors while proceeding the wax-up, investing, and casting procedure Purpose: The purposes of this study were to measure the marginal adaptation of the casting titanium coping and machine-milled titanium coping according to the casting methods and the marginal configurations. Material and method: The marginal configurations were used chamfer shoulder, and beveled shoulder. The total 30 copings were used, and these are divided into 6 groups according to the manufacturing method and marginal configuration. The gap between margin of the model and the restoration was measured with 3-dimensional measuring microscope. Results: The following results were obtained; 1. casting gold coping demonstrated the best marginal seal, followed by casting titanium coping finally machine-milled titanium copings. 2. In casting titanium coping, chamfer demonstrated the best marginal seal, followed by shoulder and beveled shoulder. There was no significantly difference in shoulder and beveled shoulder. But all margin form has clinically acceptable 3. In machine-milled titanium copings, chamfer demonstrated the best marginal seal, followed by shoulder and beveled shoulder. Beveled shoulder show large and uneven marginal gap Conclusions: Above result revealed that marginal adaptation of the titanim coping is avail able in the clinical range, it can be used as an alternative metal and it is prefered especially in chamfer or shoulder margin during implant superstructure fabrication. But there should be more research on machine-milled titanium in order to use it in the clinics.

Prediction of Shearing Die Life for Producing a Retainer using FE Analysis (유한요소해석을 이용한 리테이너 전단 금형 수명예측)

  • Lee, I.K.;Lee, S.Y.;Lee, S.K.;Jeong, M.S.;Seo, P.K.;Lee, K.H.;Kim, B.M.
    • Transactions of Materials Processing
    • /
    • v.24 no.4
    • /
    • pp.264-271
    • /
    • 2015
  • In the current study, a method was proposed to quantitatively predict the wear and fatigue life of a shearing die in order to determine an effective replacement period for the die. The shearing die model of a retainer manufacturing process was used for the proposed method of quantitative life prediction. The retainer is produced through shearing steps, such as piercing and notching. The shearing die of the retainer is carefully controlled because the dimensional accuracy of the retainer is critical. The fatigue life for the shearing die was predicted using ANSYS considering S-N curves of STD11 and Gerber’s equation. The wear life for the shearing die was predicted using DEFORM-3D considering the Archard’s wear model. Experimental shearing of the retainer was conducted to verify the effectiveness of the proposed method for predicting die life. The fatigue failure of the shearing die was macroscopically measured. The wear depth was measured using a 3D coordinate measuring machine. The results showed that the wear and fatigue life in the FE analysis agree well with the experimental results.

Three-dimensional accuracy of different correction methods for cast implant bars

  • Kwon, Ji-Yung;Kim, Chang-Whe;Lim, Young-Jun;Kwon, Ho-Beom;Kim, Myung-Joo
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.1
    • /
    • pp.39-45
    • /
    • 2014
  • PURPOSE. The aim of the present study was to evaluate the accuracy of three techniques for correction of cast implant bars. MATERIALS AND METHODS. Thirty cast implant bars were fabricated on a metal master model. All cast implant bars were sectioned at 5 mm from the left gold cylinder using a disk of 0.3 mm thickness, and then each group of ten specimens was corrected by gas-air torch soldering, laser welding, and additional casting technique. Three dimensional evaluation including horizontal, vertical, and twisting measurements was based on measurement and comparison of (1) gap distances of the right abutment replica-gold cylinder interface at buccal, distal, lingual side, (2) changes of bar length, and (3) axis angle changes of the right gold cylinders at the step of the post-correction measurements on the three groups with a contact and non-contact coordinate measuring machine. One-way analysis of variance (ANOVA) and paired t-test were performed at the significance level of 5%. RESULTS. Gap distances of the cast implant bars after correction procedure showed no statistically significant difference among groups. Changes in bar length between pre-casting and post-correction measurement were statistically significance among groups. Axis angle changes of the right gold cylinders were not statistically significance among groups. CONCLUSION. There was no statistical significance among three techniques in horizontal, vertical and axial errors. But, gas-air torch soldering technique showed the most consistent and accurate trend in the correction of implant bar error. However, Laser welding technique, showed a large mean and standard deviation in vertical and twisting measurement and might be technique-sensitive method.

THE EFFECT OF DENTURE CLEANSERS ON SOFT LINING MATERIALS (의치 세정제가 탄성 의치상 이장재에 미치는 효과에 관한 연구)

  • Jang, Bok-Sook;Kim, Chang-Whe;Kim, Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.2
    • /
    • pp.219-235
    • /
    • 1993
  • To determine the compatibilities of soft liming materials with denture cleansers by measuring the flexibility and elasticity and investigating the surface changes, 4 self-curing acrylic resin soft lining materials and 1 heat-curing silicone soft lining material were evaluated. 3mm thick x 20mm diameter discs of soft lining materials were individually bonded to a hard acrylic resin base as per manufacturers’instructions. Using an Instron universal testing machine, a static stress of $2kg/cm^2$ was applied for 30secs., the strain in compression was measured, giving an indication of the material’s flexibility. Elastic recovery was measured at 10secs. After removal of stress. Surface changes were investigated with Stereomicroscope. Then the specimens were immersed in 4alkaline peroxide denture cleansers and water as control group, tests were carried out at 1 day, 2 days, 7 days, 14 days and 30 days. The results were as follows : 1. Alkaline peroxide denture cleansers caused considerable porosity on the surface of selfcuring acrylic resin soft lining materials, and the most affected by the cleansers were Viscogel, Coe-Soft, Coe-Comfort, Lynal, in that order. 2. There was significant difference in flexibility between each soft lining material except for Coe-Comfort and Visco-gel, and every soft lining material was significant difference in elasticity. Especially Molloplast-B and Lynal were less flexible and more elastic than other soft lining materials(p<0.05). 3. The denture cleansers increased the flexibility and elasticity of the soft lining materials compared with control group(p<0.05), and Denalan, Polident, Kleenite, Efferdent affected the soft lining materials in that order. 4. There was significant difference in flexibility between each denture cleanser except for Denalan and Polident(p<0.05). Though Denalan and Polident, Denalan and Kleenite did not show significant difference in elasticity, other denture cleansers showed significant difference among each other(p<0.05). 5. Clinically Coe-Comfort, Coe-Soft and Visco-gel were incompatible with alkaline peroxide denture cleansers, and Lynal would be used within only 2 weeks. But Molloplast-B was compatible with alkaline peroxide denture cleansers.

  • PDF

A COMPARATIVE STUDY ON THE ACCURACY OF IMPRESSION METHOD USING ADDITION SILICONE PUTTY IMPRESSION MATERIAL (부가중합형 Silicone putty 인상재를 이용한 인상채득 방법의 정확성에 관한 연구)

  • Je, Hong-Ji;Jeong, Chang-Mo;Jeon, Young-Chan;Hwang, Hie-Seong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.2
    • /
    • pp.373-383
    • /
    • 1996
  • In order to compare the accuracy of impression method using addition silicone putty impression material, metal master die was fabricated with 4 cylindrical abutments that were similar in shape to mandibular arch. Among the 4 abutments, two(A, D) with 8mm width and 7mm height were formed in the 2nd molar regions and the other two(B, C) with 6mm width and 7mm height were on the canine regions. Impressions were taken using one-step putty wash impression technique and two-step putty wash impression technique by three different types of impression materials(Perfect, Express, Exaflex). Upon measuring the distance between the abutments on the model by three dimensional measuring machine, the percent of devitaion of the materials were obtained, rendering the following results. The results obtained are as follows : 1. There was no significant difference in accuracy in regard with the impression method between one-step putty wash impression technique and two-step putty wash impression technique using addition silicone putty impression material. 2. There were no difference in accuracy among with three different addition silicone putty impression materials. 3. All the distances between abutments on improved stone models increased in comparison with those on the metal master model.

  • PDF

Accuracy of five implant impression technique: effect of splinting materials and methods

  • Lee, Sang-Jik;Cho, Sung-Bum
    • The Journal of Advanced Prosthodontics
    • /
    • v.3 no.4
    • /
    • pp.177-185
    • /
    • 2011
  • PURPOSE. The aim of this study was to evaluate the effect of dimensional stability of splinting material on the accuracy of master casts. MATERIALS AND METHODS. A stainless steel metal model with 6 implants embedded was used as a master model. Implant level impressions were made after square impression copings were splinted using 5 different techniques as follows. (1) Splinted with autopolymerizing resin and sectioned, reconnected to compensate polymerization shrinkage before the impression procedure. (2) Splinted with autopolymerizing resin just before impression procedure. (3) Primary impression made with impression plaster and secondary impression were made over with polyether impression material. (4) Splinted with impression plaster. (5) Splinted with VPS bite registration material. From master model, 5 impressions and 5 experimental casts, total 25 casts were made for each of 5 splinting methods. The distortion values of each splinting methods were measured using coordinate measuring machine, capable of recordings in the x-, y-, z- axes. A one-way analysis of variance (ANOVA) at a confidence level of 95% was used to evaluate the data and Tukey's studentized range test was used to determine significant differences between the groups. RESULTS. Group 1 showed best accuracy followed by Group 3 & 4. Group 2 and 5 showed relatively larger distortion value than other groups. No significant difference was found between group 3, 4, 5 in x-axis, group 2, 3, 4 in y-axis and group 1, 3, 4, 5 in z-axis (P<.0001). CONCLUSION. Both Splinting impression copings with autopolymerizing resin following compensation of polymerization shrinkage and splinting method with impression plaster can enhance the accuracy of master cast and impression plaster can be used simple and effective splinting material for implant impression procedure.