• Title/Summary/Keyword: 3-Dimensional Measurement

Search Result 1,256, Processing Time 0.032 seconds

Analysis on Hand Types of Elderly Women (노년층 여성의 손 유형 분석)

  • Choi, Eun-Hee;Do, Wol-Hee
    • Fashion & Textile Research Journal
    • /
    • v.15 no.4
    • /
    • pp.574-582
    • /
    • 2013
  • This study categorizes and analyzes hand types based on 2-Dimensional measurements of women in their 60-80's in order to establish initial data that can help develop a well-fitted glove and hand protector for elderly women. A total of 22 measurement items were selected to provide information about Size Korea (2010) 3D hand measurements. Participants in the study were 353 elderly women over the age of 60. Subjects were divided into two age groups (60's and over 70's). Statistical tests (such as Descriptive Analysis and T-test) analyzed the data and ascertained the age differences. A factor analysis and cluster analysis were conducted to classify elderly women hand types. The disparities between 20-30's and over 60's age groups were compared by T-test with the SPSS 20 program for Windows. The results in this study are follows: The hand shapes for elderly women were divided into 3 groups. Elderly women's Hand Type A is average length and the medium breadth hand type. Type B is the biggest length and breadth, Type C is the smallest length and breadth hand type. There were significant differences in the 20-30's and over 60's age groups for most hand length and breadth items. In addition, the mean measurement value of the length items decreased as the age increased; however, the diversity of items increased, so that it became shorter and wider. Further study should include the classification of hand shape dimensions for each figure type of sizing gloves for elderly women. We expect hand types to be applicable to the manufacture of gloves for elderly women.

The Digital Model Generation for the Human Body Measurement (인체 계측을 위한 수치모형생성)

  • 이재기;최석근;임인섭
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.15 no.1
    • /
    • pp.81-89
    • /
    • 1997
  • The size and shape of the human body has been an important factor not only in anthropology but in integration of designs aimed for daily use. Although the three-dimensional measurements have been proposed and obtained introducing new methods, there still remains many problems concerning how to analyze and evaluate the results. In this study, we have got the internal and external orientation factors, image coordinates from the ac-quired photographs, have calaulated the object coordinates through Bundle Adjustment, have matched multi-images. have drawn the object in the computer, and smoothly handled the surface of the body model using the Au-to-CAD system or graphic processing utility then we could generate the digital model of human body. The. results show that once digital modeling of the body is generated. the information which a designer needs can be acquired and the adequate calculations for many application fields can be done easily and many geometrical properties could be extracted. Therefore we propose the possibility of indirect human body measurement through digital model generation.

  • PDF

DEVELOPMENT OF IONOSPHERIC TOMOGRAPHY MODEL USING GPS (GPS를 이용한 전리층 토모그래피 모델 개발)

  • Choi Byung-Kyu;Park Jong-Uk;Lee Sang-Jeong
    • Journal of Astronomy and Space Sciences
    • /
    • v.23 no.3
    • /
    • pp.237-244
    • /
    • 2006
  • We produced the electron density distribution in the ionosphere over South Korea using the data from nine permanent GPS (Global Positioning System) stations which have been operated by KASI (Korea Astronomy and Space Science Institute). The dual-frequency GPS receiver data was used to precisely estimate the electron density in the ionosphere and we obtained the precise electron density profile based on two-dimensional TEC (Total Electron Contents). We applied ART (Algebraic Reconstruction Technique), which is one of the most commonly used algorithms to develop the tomography model. This paper presented the electron density distribution over South Korea with time. We compared with the electron density profiles derived from the GPS tomography reconstruction, Ionosonde measurement data obtained by observations, and the IRI-2001 values. As a result, the electron density profile by GPS reconstruction was in excellent agreement with the electron density profile obtained by Ionosonde measurement data.

Precise Adsorption Measurement Technique by a Phase Modulated Ellipsometry (편광변조 타원해석법에 의한 정밀 흡착측정기술)

  • Choi, B.I.;Nham, H.S.;Park, N.S.;Youn, H.S.;Lim, Tong-Kun
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.6
    • /
    • pp.531-538
    • /
    • 2004
  • Studies of adsorption isotherms with sharp step-wise layer condensation help us to better understanding of two dimensional layers. For this, an adsorption isotherm apparatus, using a phase modulated ellipsometric technique, has been constructed and an adsorption experiment has been performed. With subatomic scale resolution(∼0.3 $\AA$), the adsorption processes could be observed by ellipsometric signals. On measurement of multilayer adsorption of argon on highly oriented pyrolytic graphite(HOPG), thousands of adsorbed layers were observed at 34.04 K, which suggests that the adsorption is completely wet. On the contrary nine sharp layers of steps for adsorptions and desorptions were observed at 67.05 K. These isotherms obtained can provide a lot of information about thermodynamic states, bonding energies between adsobate and substrate, and structure transitions in the adsorbed film.

A Study on the Measurement Accuracy and Linearity of the Mandibular Kinesiograph (Mandibular Kinesiograph의 선형충실도 및 계측정확도에 관한 연구)

  • Kim, In-Kwon
    • The Journal of the Korean dental association
    • /
    • v.22 no.7 s.182
    • /
    • pp.607-620
    • /
    • 1984
  • The validity of the Kinesiegraph (MHG-5R) output was studied using a non-ferromagnetic positioning device within working range of a 3 cm wide by 4 cm deep by 5 cm high three dimensional lattice. To determine how well observed values of the M K G outputs may predict case values of actual measurements, relationships between those values were tested by viewing scatter plots and correlation between observed values and actual values. In order to devise some form of served values of the M k G outputs (volts), statistical regression analysis was performed. The statistical analysis showed that observed values and actual values were strongly correlated. However, high correlation does not necessarily mean perfect predictability of given linear models. The formulated models were not able to predict all of acutal values this is partly 엳 새the discreteness of dependent variables (actual values) and also is because of independent nature of observed values. In conclusion, unless the Kinesiograph is suitably modified, the inherent nonlinearity characteristic of the system output limits its application to the measurement of a limited range of jaw movements.

  • PDF

Evaluating the Effectiveness of Quasi-Zenith Satellite System on Positioning Accuracy Based on 3D Digital Map Through Simulation

  • Suh, Yong-Cheol;Konishi, Yusuke;Shibasaki, Ryosuke
    • Proceedings of the KSRS Conference
    • /
    • 2002.10a
    • /
    • pp.751-756
    • /
    • 2002
  • Since the operation of the first satellite-based navigation services, satellite positioning has played an increasing role in both surveying and navigation, and has become an indispensable tool for precise relative positioning. However, in some situations, e.g. at a low angle of elevation, the use of satellites for navigation is seriously restricted because obstacles like buildings and mountains can block signals. As a mean to resolve this problem, the quasi-zenith satellite system has been proposed as a next-generation satellite navigation system. Quasi-zenith satellite is a system which simultaneously deploys several satellites in a quasi-zenith geostationary orbit so that one of the satellites always stay close to the zenith if viewed from a specific point on the ground of East Asia. Thus, if a position measurement function compatible with GPS is installed in the quasi-zenith and stationary satellites, and these satellites are utilized together with the GPS, four satellites can be accessed simultaneously nearly all day long and a substantial improvement in position measurement, especially in metropolitan areas, can be achieved. The purpose of this paper is to evaluate the effectiveness of quasi-zenith satellite system on positioning accuracy improvement through simulation by using precise orbital information of the satellites and a three-Dimensional digital map. Through this simulation system, it is possible to calculate the number of simultaneously visible satellites and available area of the positioning without the need of actual observation.

  • PDF

In Vivo Measurement of Site-Specific Peritoneal Solute Transport Using a Fiber-Optic-based Fluorescence Photobleaching Technique

  • Lee, Donghee;Kim, Jeong Chul;Shin, Eunkyoung;Ju, Kyung Don;Oh, Kook-Hwan;Kim, Hee Chan;Kang, Eungtaek;Kim, Jung Kyung
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.3
    • /
    • pp.228-236
    • /
    • 2015
  • Fluorescence recovery after photobleaching (FRAP) is a well-established method commonly used to measure the diffusion of fluorescent solutes and biomolecules in living cells or tissues. Here a fiber-optic-based FRAP (f-FRAP) system was developed, and validated using macromolecules in water and agarose gels of different concentrations. We applied f-FRAP to measure the site-specific diffusion of fluorescein (NaFluo) in peritoneal membranes (PMs) on the liver, cecum, and kidney of a living rat during peritoneal dialysis. Diffusion of fluorescein in PM varied in a time-dependent manner according to the type of organ ($D_{PM\;on\;Liver}/D_{NaFluo}=0.199{\pm}0.085$, $D_{PM\;on\;Cecum}/D_{NaFluo}=0.292{\pm}0.151$, $D_{PM\;on\;Kidney}/D_{NaFluo}=0.218{\pm}0.110$). The proposed method allows direct quantitative measurement of the three-dimensional diffusion in local PM in vivo, which was previously inaccessible by peritoneal function test methods such as peritoneal equilibration test (PET) and standardized PM assessment (SPA). f-FRAP is promising for local and dynamic assessments of peritoneal pathophysiology and the mass transport properties of PMs, presumed to be affected by variation of tissue structures over different organs and functional changes of the PM with years of peritoneal dialysis.

Designs of Pipe Fitting with Three Dimensional Measurement and Kinematic Constrained Equations (파이프 체결을 위한 3차원 측정 및 기구적 구속조건 기반의 설계 방식)

  • Yang, Jeong-Yean
    • The Journal of the Korea Contents Association
    • /
    • v.22 no.3
    • /
    • pp.54-61
    • /
    • 2022
  • Ship is a huge system including a variety of pipe arrangements. Pipes are installed according to the design layout, however the end poistion of pipes are not well matched owing to its measurement and construction errors. In this situation, the customized pipe fitting is frequently designed to connect with both pipes, the position of which are manually measured. This paper focused that these two coordinates are measured by point cloud from RGBD sensor and the relative transformation induced by positional and orientational differences is calculated by inverse kinematics in robotics theory. Therefore, the result applies for the methodology of the pipe connection design. The pipe coordinate that is estimated by the matching and the probabilistic RANSAC method will be verified by experiments. The kinematic design parameters are computationally calculated by using the minimum degree of freedom that connects both pipe coordinates.

Three-dimensional Machine Vision System based on moire Interferometry for the Ball Shape Inspection of Micro BGA Packages (마이크로 BGA 패키지의 볼 형상 시각검사를 위한 모아레 간섭계 기반 3차원 머신 비젼 시스템)

  • Kim, Min-Young
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.19 no.1
    • /
    • pp.81-87
    • /
    • 2012
  • This paper focuses on three-dimensional measurement system of micro balls on micro Ball-Grid-Array(BGA) packages in-line. Most of visual inspection system still suffers from sophisticate reflection characteristics of micro balls. For accurate shape measurement of them, a specially designed visual sensor system is proposed under the sensing principle of phase shifting moire interferometry. The system consists of a pattern projection system with four projection subsystems and an imaging system. In the projection system, four subsystems have spatially different projection directions to make target objects experience the pattern illuminations with different incident directions. For the phase shifting, each grating pattern of subsystem is regularly moved by PZT actuator. To remove specular noise and shadow area of BGA balls efficiently, a compact multiple-pattern projection and imaging system is implemented and tested. Especially, a sensor fusion algorithm to integrate four information sets, acquired from multiple projections, into one is proposed with the basis of Bayesian sensor fusion theory. To see how the proposed system works, a series of experiments is performed and the results are analyzed in detail.

Manufacturing of a Korean Hand Phantom with Human Electrical Properties at 835 MHz and 1,800 MHz Bands (835 MHz 및 1,800 MHz 대역에서 인체의 전기적 특성을 가지는 한국인 손 모양의 팬텀 제작)

  • Choi, Donggeun;Gimm, Yoonmyoung;Choi, Jaehoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.5
    • /
    • pp.534-540
    • /
    • 2013
  • Interest of the hand effect on the electromagnetic wave are internationally increasing with the increase of the use of the mobile phone. IEC TC106(International Electrotechnical Commission, Technical Committee 106) promotes international research exchange program in order to reflect the effect of human hands in the standard assessment method of human exposure dosimetry by the electromagnetic wave of mobile phones. Since current commercialized hand phantom is manufactured by taking into account the average size of westerners and provides only one grip posture, it imposes many restrictions on the accurate SAR measurement. Therefore, the development of proper hand phantom accounting for domestic situation and various grip posture capability is essential in order to analyze the accurate effect of human hand on the exposure estimation. In this paper, a jelly hand phantom suitable for Korean was manufactured with various grip posture capability at 835 MHz and 1,800 MHz bands. Although the tolerances of permittivity and conductivity of the manufactured hand phantom are with ${\pm}10%$ each, it was much less than CTIA(Cellular Telecommunication Industry Association) tolerance of ${\pm}20%$ at both bands. Its 3D CAD(3 Dimensional Computer Aided Design) file which was developed can be utilized for the simulation of human hand effect on SAR measurement of mobile phones. The findings in this study can be utilized for the analysis of human hand effect on SAR measurement of a mobile phone.