• Title/Summary/Keyword: 3-Dimensional Measurement

Search Result 1,256, Processing Time 0.029 seconds

Acquiring 3-dimensional data of a human face using a laser slit-ray projection method

  • Ishimatsu, T.;Taguchi, N.;Kawasue, K.;Kumon, K.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1988.10b
    • /
    • pp.816-821
    • /
    • 1988
  • This paper describes a system which enables a fast 3-dimensional measurement of a human face using a sli-ray projection method. One distinctive feature of our system is that a real-time video signal processor is employed in order to reduce the amount of image data to be processed and enable a fast measurement. Another feature of our system is that a skillful calibration software is developed. Due to this calibration software, opetators can be free from cumbersome settings of the measuring system.

  • PDF

TDOA Measurement Based Taylor Series Design Method Considering Height Error for Real-Time Locating Systems (실시간 위치추적 시스템에서 높이 오차를 고려한 TDOA 측정치 기반 테일러 급수 설계 방법)

  • Kang, Hee-Won;Hwang, Dong-Hwan;Park, Chan-Sik
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.8
    • /
    • pp.804-809
    • /
    • 2010
  • This paper proposes a Taylor-series design method which reduces the height error of the tag when readers are arranged at the same height in 3-dimensional space. The proposed method consists of two steps. Firstly, the planar position is estimated by the Taylor-series method using the TDOA measurement. Next, the height is estimated from the estimated planar position. In order to show the validity of the proposed method, computer simulations were performed for the static case and linear trajectory of the tag. Results show that the proposed method gives convergent estimated position and better height estimate than the Taylor series method.

3-D Profile Measurement System of Live Human Faces for the '93 Taejon Expo Kumdori Robot Scupltor (93 대전엑스포 꿈돌이 조각가로보트의 인물형상 측정시스템)

  • 김승우;박현구;김문상
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.3
    • /
    • pp.670-679
    • /
    • 1995
  • This paper presents the 3-D profile measurement system of live human faces, which was developed specially for 'KUMDORI sculptor robot' of the '93 Taejon Exposition. '93 Taejon EXPO. The basic principle for measurement adopts the slit beam projection which is a method of measuring 3-D surface profiles using geometric optics between the slit beam and the CCD camera. Since the slit beam projection consumes long measuring time, it is unfit to measure the 3-D profiles of living objects as human. Therefore, the projection type slit beam method which consumes short measuring time is newly suggested. And an algorithm to reconstruct the 3-D profile from the deformed images using finite approximated calibration is suggested and practically implemented. The projection type slit beam method was applied to spectators in a period of '93 Taejon EXPO. The measurement results show that the technique is suitable for 3-D face profile measurement on a living body.

Acquisition Model for 3D Shape Measurement Data

  • Park, Jong-Sik;Jang, Wang-Jin;Lee, Seong-Beom;Park, Chan-Seok
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.9 no.4
    • /
    • pp.16-21
    • /
    • 2008
  • The demand for three-dimensional (3D) shape measurements is increasing in a variety of fields, including the manufacture of molds and dies. The most popular technology for 3D shape measurement is the coordinate measuring machine (CMM) with a contact trigger probe. Although a CMM provides a high degree of accuracy, it is inefficient due to its long measuring time. It also has difficulty measuring soft objects that can be deformed by the touch of the contact probe. In addition, a CMM cannot digitize areas that are difficult to reach, and cannot capture very minute details on the surface of complex parts. For these reasons, optical non-contact measurement techniques are receiving more attention since they eliminate most of the problems associated with contact methods. Laser scanning is emerging as one of the more promising non-contact measurement techniques. This paper describes various acquisition considerations for laser scanning, including the accuracy of the 3D scan data, which depends on the charge-coupled device (CCD) gain and noise. The CCD gain and noise of a 3D laser scanner are varied while keeping the other conditions constant, and the measurement results are compared to the dimensions of a standard model. The experimental results show that a considerable time savings and an optimum degree of accuracy are possible by selecting the proper CCD gain and noise.

Three Dimensional Measurement of Ideal Trajectory of Pedicle Screws of Subaxial Cervical Spine Using the Algorithm Could Be Applied for Robotic Screw Insertion

  • Huh, Jisoon;Hyun, Jae Hwan;Park, Hyeong Geon;Kwak, Ho-Young
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.4
    • /
    • pp.376-381
    • /
    • 2019
  • Objective : To define optimal method that calculate the safe direction of cervical pedicle screw placement using computed tomography (CT) image based three dimensional (3D) cortical shell model of human cervical spine. Methods : Cortical shell model of cervical spine from C3 to C6 was made after segmentation of in vivo CT image data of 44 volunteers. Three dimensional Cartesian coordinate of all points constituting surface of whole vertebra, bilateral pedicle and posterior wall were acquired. The ideal trajectory of pedicle screw insertion was defined as viewing direction at which the inner area of pedicle become largest when we see through the biconcave tubular pedicle. The ideal trajectory of 352 pedicles (eight pedicles for each of 44 subjects) were calculated using custom made program and were changed from global coordinate to local coordinate according to the three dimensional position of posterior wall of each vertebral body. The transverse and sagittal angle of trajectory were defined as the angle between ideal trajectory line and perpendicular line of posterior wall in the horizontal and sagittal plane. The averages and standard deviations of all measurements were calculated. Results : The average transverse angles were $50.60^{\circ}{\pm}6.22^{\circ}$ at C3, $51.42^{\circ}{\pm}7.44^{\circ}$ at C4, $47.79^{\circ}{\pm}7.61^{\circ}$ at C5, and $41.24^{\circ}{\pm}7.76^{\circ}$ at C6. The transverse angle becomes more steep from C3 to C6. The mean sagittal angles were $9.72^{\circ}{\pm}6.73^{\circ}$ downward at C3, $5.09^{\circ}{\pm}6.39^{\circ}$ downward at C4, $0.08^{\circ}{\pm}6.06^{\circ}$ downward at C5, and $1.67^{\circ}{\pm}6.06^{\circ}$ upward at C6. The sagittal angle changes from caudad to cephalad from C3 to C6. Conclusion : The absolute values of transverse and sagittal angle in our study were not same but the trend of changes were similar to previous studies. Because we know 3D address of all points constituting cortical shell of cervical vertebrae. we can easily reconstruct 3D model and manage it freely using computer program. More creative measurement of morphological characteristics could be carried out than direct inspection of raw bone. Furthermore this concept of measurement could be used for the computing program of automated robotic screw insertion.

A Study on the Compensation of Thermal Errors for Phase Measuring Profilometry (PMP 형상 측정법의 열 변위 보정에 관한 연구)

  • Kim, Gi-Seung;Park, Yoon-Chang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.6
    • /
    • pp.598-603
    • /
    • 2019
  • Three-dimensional shape measurement technology is used in various industries. Among them, optical three-dimensional shape measurement techniques based on the optical trigonometry are mainly used in the field of semiconductor product inspection, where large quantities of three-dimensional shape measurements are made daily in factories and fine measurements are also required. The light source and the drive circuit, which are components of three-dimensional measurement equipment based on this optical trigonometry, produce heat generated by prolonged operation, and may be exposed to conditions where the ambient temperature is not constant, resulting in temperature-induced measurement errors. In this study, the compensation method of the Thermal Errors for Phase Measuring Profilometry is proposed. Three-Dimensional Shape Measurement Equipment based on Phase Measuring Profilometry is implemented to measure the height of an object and ambient temperature for 10 Hours, and a regression line was obtained line by making simple linear regression using measured temperature and height values. This regression line was used to correct the error of the height measurement according to the temperature, and thermal error was from 139.88 um(Micrometer) to 13.12 um.

3-Dimensional Calibration and Performance Evaluation Method for Pupil-labs Mobile Pupil Tracking Device (퓨필랩 모바일 동공 추적 장치를 위한 3차원 캘리브레이션 및 성능 평가 방법)

  • Mun, Ji-Hun;Shin, Dong-Won;Ho, Yo-Sung
    • Smart Media Journal
    • /
    • v.7 no.2
    • /
    • pp.15-22
    • /
    • 2018
  • Pupil tracking technologies can be used as an efficient information provider means that provides convenience to the user by connecting with a smart device. In this paper, we measure the distance of user gaze point using the pupil tracking device which produced by Pupil-labs, also shows the experimental result with analyzing accuracy and precision. Based on that the pupil gaze point location which tracked by pupil tracking device is compared with object target in terms of error. Since the mobile pupil tracking device is also one kind of camera, we have to perform the calibration before using the device. Not only generally used 2-dimensional calibration, but also 3-dimensional calibration method is explained. To get the improved accuracy of 2-dimensional calibration result, the 3-dimensional calibration set an imaginary plane and executes the calibration in various 3-dimensional spaces. To show the efficiency of 3-dimensional calibration, we analyze the experimental result. It also introduces various using methods and information that can be obtained through the device.

A Measuring Method for 3-DOF Displacement by Using Spherical Reflector (구면 반사체를 이용한 3 자유도 변위 측정 기법)

  • Kwon, Ki-Hwan;Moon, Hong-Kie;Cho, Nahm-Gyoo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.12
    • /
    • pp.2687-2694
    • /
    • 2002
  • A precision displacement measuring system is proposed, which can detect the 3-DOF translational motions of precision positioning devices. The optical system, which is composed of two diode-laser sources and two quadratic PSDs, is adapted to detect the position of the spherical reflector usually mounted on the platform of positioning devices. Each of the laser beams from diode-laser sources is reflected at the highly reflective surface of the sphere; hence, the 3-dimensional position of the sphere causes the directional change of the reflected beams, which is detected by the PSDs. In this paper, we define the relationships between the output values of the two PSDs and the 3-DOF translational motions of the sphere. Based on a deduced measurement model, we perform measurement simulation and evaluate the performance of the proposed measurement system: linearity, sensitivity, measuring range, and measurement error. The results show that the proposed measuring method is very useful for the measurement of the precision displacement of 3-DOF micro motions.

Stability Evaluation of Multi-storied Stone Pagoda in the Daewonsa Temple using Three-dimensional Image Analysis (3차원 영상분석을 이용한 대원사다층석탑의 안정성 평가)

  • Jun, Byung-Kyu;Lee, Chan-Hee;Suh, Man-Cheol
    • Journal of Conservation Science
    • /
    • v.22
    • /
    • pp.31-42
    • /
    • 2008
  • A stone cultural heritage often lacks design drawing and detailed geometric informations, thus it becomes more difficult to conservation and restoration. Even though there is active database of detail shape information and numerical measurement for stone monuments, most of the data is in hard-to-utilize two-dimensional images. The new technology developed to overcome this problem is three-dimensional image scanning system. The multi-storied stone pagoda of the Daewonsa temple was analysed with 3D scanning image data then survey map with orientation displacement was evaluated. The difference of each side became apparent with the members of the stone properties was measured, also horizontal and vertical displacement occurred. Horizontal displacement occurred in increasing severity from left to right and from body section to upper part. The 8th roof stones are leaning toward northwest direction due to lateral displacement. The evaluation and measurement of displacement could cause a little errors due to the characteristics uneven surface of stone monuments, computer program and mistakes from the researcher. In future, more precise measurement and stability studies should be done to suggest that accurate data for conservation and understanding of damage condition can be provided.

  • PDF