• Title/Summary/Keyword: 3-D contact

Search Result 982, Processing Time 0.049 seconds

A Study on the Heat Transfer and Durability of Carbon Nano Coating for the Safety Improvement of a Pool Boiling System (비등 열전달 시스템의 안정성 향상을 위한 탄소나노튜브 코팅의 열전달 및 내구성에 대한 연구)

  • Jeon, Yong-Han;Kim, Young-Hun;Kim, Nam-Jin
    • Journal of the Korea Safety Management & Science
    • /
    • v.19 no.1
    • /
    • pp.211-217
    • /
    • 2017
  • In this study, we investigated to the heat transfer performance of coating nano-structure with various shapes and patterns on the heat transfer surface. As a result of the measurement of the 3D nano shape, it was confirmed that the roughness generally increases when the adhesive is sprayed on the coating surface and finished durability experiment. In the case of TEOS adhesive, the roughness increased by $0.074{\mu}m$, $0.012{\mu}m$ and $0.015{\mu}m$, and the contact angle decreased $12.64^{\circ}$, $1.31^{\circ}$, $9.84^{\circ}$ at the coating time of 120 seconds, 180 seconds and 240 seconds, respectively. In the case of PVA adhesive, the roughness increased by $0.069{\mu}m$, $0.056{\mu}m$ and $0.03{\mu}m$, and the contact angle decreased $2.85^{\circ}$, $4.82^{\circ}$, $6.96^{\circ}$ at the coating time of 120 seconds, 180 seconds and 240 seconds, respectively. In the case of DGEBF adhesive, the roughness increased by $0.042{\mu}m$, $0.053{\mu}m$ and $0{\mu}m$, and the contact angle decreased $0.81^{\circ}$ at the coating time of 120 seconds, increased $4.82^{\circ}$, $6.96^{\circ}$ at the coating time of 180 seconds and 240 seconds, respectively. As a result, the durability tends to decrease as more nano-structures are deposited, and 3D nano shapes, contact angles and SEM photographs showed that the performance of the PVA adhesive was superior among the three adhesives.

Fabrication of a Porous Copper Current Collector Using a Facile Chemical Etching to Alleviate Degradation of a Silicon-Dominant Li-ion Battery Anode

  • Choi, Hongsuk;Kim, Subin;Song, Hayong;Suh, Seokho;Kim, Hyeong-Jin;Eom, KwangSup
    • Corrosion Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.249-255
    • /
    • 2021
  • In this work, we proposed a facile method to fabricate the three-dimensional porous copper current collector (3D Cu CC) for a Si-dominant anode in a Li-ion battery (LiB). The 3D Cu CC was prepared by combining chemical etching and thermal reduction from a planar copper foil. It had a porous layer employing micro-sized Cu balls with a large surface area. In particular, it had strengthened attachment of Si-dominant active material on the CC compared to a planar 2D copper foil. Moreover, the increased contact area between a Si-dominant active material and the 3D Cu could minimize contact loss of active materials from a CC. As a result of a battery test, Si-dominant active materials on 3D Cu showed higher cyclic performance and rate-capability than those on a conventional planar copper foil. Specifically, the Si electrode employing 3D Cu exhibited an areal capacity of 0.9 mAh cm-2 at the 300th cycles (@ 1.0 mA cm-2), which was 5.6 times higher than that on the 2D copper foil (0.16 mAh cm-2).

A Study on effect that position of contact area at adjacent side has on fractures of porcelains in case of porcelain fused to metal crown (금속 소부 도재관의 경우 인접면에서 접촉점의 위치가 도재 파절에 미치는 영향에 관한 연구)

  • Kim, Yong-Won
    • Journal of Technologic Dentistry
    • /
    • v.29 no.2
    • /
    • pp.173-180
    • /
    • 2007
  • There was a great problem about the deposition between materials of a different kind at the beginnings of the introduction of porcelains, however, thereafter the deposition efficiency was settlded to the sufficient level of all user thanks to effort to have studied by many scholars and clinical authorities. But in a clinical process, as the difference of designs has an effect on fractures of porcelains, this researcher divided them into 4 groups of A: 1 mm, B: 2 mm, C: 3 mm, and D: 4 mm, and made 40 pieces to each 10 as the test samples to consider a length axis of tooth for studies in accordance with a position of a finishing line to meet between porcelain and metal at the contact point at the adjacent side to a metal porcelain. The sample materials are those to be use at the open market and the test samples wer completed by the same manufacturing technique to that of existent metal porcelain tube. s a result of the strength test on fractures, the average value is as in the following, A: 1 mm - 8.5bar, B: 2 mm - 10.5bar, C: 3 mm - 14.3bar, and D: 4 mm - 15.0bar. In case of the metal porcelain tube, the more faraway to process parts of metal and porcelain from the contact point of adjacent side has the stronger strength of fractures, Accordingly, the research shows that it had better to keep off more than 3 to consider a ledngth axis of tooth.

  • PDF

Low Resistivity Ohmic Ni/Si/Ni Contacts to N-Type 4H-SiC (낮은 접촉저항을 갖는 Ni/Si/Ni n형 4H-SiC의 오옴성 접합)

  • Kim C. K.;Yang S. J.;Cho N. I.;Yoo H. J.
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.10
    • /
    • pp.495-499
    • /
    • 2004
  • Characteristics of ohmic Ni/Si/Ni contacts to n-type 4H-SiC are investigated systematically. The ohmic contacts were formed by annealing Ni/Si/Ni sputtered sequentially The annealings were performed at 950℃ using RTP in vacuum ambient and N₂ ambient, respectively. The specific contact resistivity(p/sub c/), sheet resistance(R/sub s/), contact resistance (R/sub c/) transfer length(L/sub T/) were calculated from resistance(R/sub T/) versus contact spacing(d) measurements obtained from TLM(transmission line method) structure. While the resulting measurement values of sample annealed at vacuum ambient were p/sub c/ = 3.8×10/sup -5/Ω㎠, R/sub c/ = 4.9 Ω and R/sub T/ = 9.8 Ω, those of sample annealed at N₂ ambient were p/sub c/ = 2.29×10/sup -4/Ω㎠, R/sub c/ = 12.9 Ω and R/sub T/ = 25.8 Ω. The physical properties of contacts were examined using XRD 3nd AES. The results showed that nickel silicide was formed on SiC and Ni was migrated into SiC. This result indicates that Ni/Si/Ni ohmic contact would be useful in high performance electronic devices.

A Practical Finite Element Analysis Model for Hydrostatic Extrusion of a Biaxial Bar (이중봉 정수압 압출의 실용적 유한요소해석 모델)

  • Yoon, S.H.;Park, H.J.;Kim, E.Z.;Lee, S.;Lee, J.;Lee, G.A.;Kim, Y.B.;Lee, Y.S.
    • Transactions of Materials Processing
    • /
    • v.22 no.3
    • /
    • pp.143-149
    • /
    • 2013
  • A new finite element model for the hydrostatic extrusion of a biaxial bar is introduced. In this model, a penalty contact algorithm, which is adopted to replace the traction boundary conditions due to the fluid in the container of the extruder, is incorporated into a consistent penalty finite element formulation for the viscoplastic deformation of a work piece during hydrostatic extrusion. Two parameters, introduced in the penalty contact algorithm in this study, a critical penalty contact pressure $P_0$ and a critical penalty contact distance $D_c$, are carefully examined for various process conditions. The proposed finite element model is applied to the hydrostatic extrusion of a Cu-clad Al bar. The extrusion loads and thickness ratios of the clad materials by the proposed model are compared in detail to values from experiments reported in the literature. Finally, it is concluded that the proposed finite element model is useful in practical implementations.

Effect of Hwangryunhaedok-tang Extracts on DNCB-induced Allergic Contact Dermatitis (DNCB로 유발된 알레르기성 접촉피부염에 황련해독탕이 미치는 영향)

  • Kim, Bo-Ae;Yang, Jae-Chan;Park, Chan-Ik
    • The Korea Journal of Herbology
    • /
    • v.24 no.2
    • /
    • pp.1-5
    • /
    • 2009
  • Objectives : HRHDT has been known as a useful prescription with antibiotic, anti-inflammatory, antioxidative and immunosuppressive activity. To evaluate anti-inflammatory effect of HRHDT, we treated HRHDT-skin in Balb/c mice model induced contact hypersensitivity. Methods : Contact hypersensitivity, a local inflammatory respinse of skin, was induced by spreading the back skin of Balb/c mice with 1% DNCB. HRHDT-skin was prepared by dissolving 3% 1,3-butylene glycol extract of HRHDT in solution and treated 2 weeks on the back skin. Results: HRHDT-skin significantly reduced TEWL and erythema by 0.4-1% of DNCB treatment compared with control group. HRHDT-skin reduced IgE on serum obtained from blood of DNCB-treated Balb/c mice. Histopathological examination showed that thickening of the epidermis, hyperkeratosis and the infiltration of inflammatory cells were found in Balb/c mice under conventional circumstances. Conclusions : These results showed that HRHDT-skin could be used as a pharmaceutical material with antiinflammatory effects by reducing IgE in contact hypersensitivity dermatitis Balb/c mice by DNCB.

Effect of Ozone Oxidation on Biodegradability of Dissolved Organic Compounds in the Landfill Leachate (오존산화가 매립지 침출수내 용존성 유기화합물의 생분해도에 미치는 영향)

  • Jeong, Seung-Hyun;Jeong, Byung-Gon
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.1
    • /
    • pp.1-6
    • /
    • 2005
  • The effect of ozone oxidation on biodegradability of leachate was studied. Ozone oxidation process was used as pre-treatment process to enhance performance of biological process in treating landfill leachate. Optimum ozone dosing rate and contact time in this experiment was $160mg\;O_3/L$ hr and 45 minutes, respectively. Biodegradability was enhanced 5.08% by ozone oxidation. The ratio of ozone demand/DOC concentration was $0.049{\sim}0.091mg\;O_3/mg$ DOC. The increase of biodegradability depending on ozone dosing rate(D) and contact time(T) can be expressed as follows ; ${\Delta}E=0.00479{\cdot}D^{0.773}{\cdot}T^{0.800}$ The biodegradation rate of DOC was increased proportionally with the increase of ozone dosing rate and contact time irrespective of landfill site age. The increase of biodegradability by ozone addition was not satisfactory. It is hard to expect significant increase in biodegradability by ozone treatment only. Thus, it is evaluated that ozone oxidation can not increase biodegradability significantly in concentrated wastewater composed of complex organic compound such as leachate.

A Study on Characteristics of Overhead Rigid Conductor System for Developing the High-speed System up to 250km/h (250km/h급 강체전차선로 시스템 개발을 위한 R-BAR 특성 고찰)

  • Bae, Sang-Joon;Jang, Kwang-Dong;Lee, Ki-Won;Park, Youn-Cheol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.3
    • /
    • pp.492-497
    • /
    • 2015
  • An overhead rigid conductor system is mainly applied to the subway and recently studies on the rigid system have been conducted for applications such as tunnels of high-speed line and speed improvement of a conventional lines up to 250km/h. Power feeding performance which is the most important in a rigid system can be measured by contact force and characteristics of this contact force are related to the shape and material of the R-BAR. In this paper, we analyze the measurements of contact force, current heating temperature, impedance of a rigid conductor which was developed in Korea, after that we compare static characteristics of home and abroad rigid conductors which have various shapes and materials.

Effect of Chungsimyeonjaeum on myocardiac cell injury in mouse myoblast $C_2Cl_{12}$ cells (청심연자음(淸心蓮子飮)이 Mouse유래 $C_2Cl_{12}$세포주에서 심근세포 손상의 보호 효과)

  • Lee, Sang-Heon;Park, Chi-Sang
    • The Journal of Korean Medicine
    • /
    • v.27 no.3 s.67
    • /
    • pp.26-37
    • /
    • 2006
  • Determination and differentiation of cells in the skeletal muscle lineage is positively regulated by cell-cell contact. Differentiation proteins proposed to mediate this effect include both classical MyoD and MEF members; potential interactions between the promyogenic activities of these classes of protein, however, are unknown. We show here that MyoD and MEF, two promyogenic family members that relate to each other in a cis fashion, form interactions with MyoD and MEF. These proteins contain myosin-heavy chainsand are enriched at sites of cell-cell contact between myoblasts. Therefore, in differentiation of MyoD and MEF from Chungsimyeonjaeum interact dependently, suggesting that the interactions occur in a cis fashion; consistent with this conclusion, MyoD-mediated differentiation is required for myoblasts to occur by Chungsimyeonjaeum. Inhibition in myoblasts of a MyoD by Staurosporine in its ability to associate with MEF interferes with differentiation as assessed by morphological and transcription levels, suggesting that this interaction is functionally important in myogenesis. Also, some of the differentiation-mediated proteins that are required for myogenesis seem to be based on interdependent activities of the promyogenic classical smad-subfamily.

  • PDF

Photoelectron Spectroscopic Investigation of Ag and Au Deposited Amorphous In-Ga-Zn-O Thin Film Surface

  • Gang, Se-Jun;Baek, Jae-Yun;Sin, Hyeon-Jun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.338.2-338.2
    • /
    • 2014
  • 투명반도체산화물은 우수한 광학적, 전기적 특성을 가지고 있기 때문에 차세대 박막트랜지스터의 채널층으로 각광을 받고 있다. 특히, 그 중에서도 a-IGZO를 이용한 TFT는 높은 가시광선 투과율(>80%)과 큰 전하이동도(>10 cm2/Vs) 를 갖는 등 좋은 광학적, 전기적 특성을 갖기 때문에 많은 연구가 이루어졌다. 여러 연구들에 의하면, a-IGZO TFT는 소스/드레인의 전극으로 어떤 물질을 사용하는지에 따라서 동작특성에 큰 영향을 미치는 것으로 알려져 있다. 일반적으로, a-IGZO 박막은 n형 반도체로써 일함수가 작은 금속과는 ohmic contact를 형성하고, 일함수가 큰 금속과는 Schottky barrier를 형성한다고 알려져 있다. 이와 관련된 대부분의 이전의 연구들에서는 각각의 전극물질에 따라 전기적인 특성변화에 초점을 맞춰서 연구하였다. 본 연구에서는 일함수가 작은 Ag와 일함수가 큰 Au를 a-IGZO의 박막 위에 얇게 증착하면서 이에 따른 고분해능 광전자분광(high-resolution x-ray photoelectron spectroscopy) 정보의 변화를 분석함으로써, 금속의 증착에 따른 금속층과 a-IGZO 표면 및 계면에서의 화학적 상태의 변화를 연구하였다. Au 4f, Ag 3d는 metallic property를 나타내기 이전까지는 lower binding energy(BE) 쪽으로 shift하였으며, In 3d 또한 lower BE 성분이 크게 증가하였다. O 1s, Ga 3d, Zn 3d들은 상대적으로 적은 변화를 나타내었는데, 이는 Ag, Au가 In과 상대적으로 더 많이 상호작용한다는 것을 의미한다. 본 발표에서는 이들 core level의 정보들과, 가전자대의 분광정보, 그리고 band bending의 정보가 제시될 것이며, 이 정보들은 metal 증착에 따른 contact 특성을 이해하는데 기여할 것으로 기대한다.

  • PDF