• 제목/요약/키워드: 3-D Stereoscopic

검색결과 526건 처리시간 0.023초

다중 스테레오를 위한 DEM 융합기법 (OEM Fusion Technique for Multi-Image stereo)

  • 김민석;우동민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 D
    • /
    • pp.3047-3049
    • /
    • 2000
  • The ability to efficiently and robustly recover accurate 3D terrain models from sets of stereoscopic images is important to many civilian and military applications. To develop an effective and practical terrain modeling system. We propose the methods which detect unreliable elevations in digital elevation maps (DEMs). and fuse several DEMs from multiple sources into an accurate and reliable result. This paper focuses on two key factors for generating robust 3D terrain models. the ability to detect unreliable elevation estimates. and to fuse the reliable elevations into a single optimal terrain model. We apply the correlation score methodology to reconstruct accurate DEM for multi-image and show the method is more effective than the conventional averaging method. The photo-realistic simulator is used for generating four simulated images from ground truth DEM and orthoimage.

  • PDF

안경식 스테레오스코픽 3DTV의 주관적 화질평가 방법에 대한 고찰 (Subjective Evaluation on Image Quality of Stereoscopic 3DTV)

  • 이호동;박민철
    • 한국방송∙미디어공학회:학술대회논문집
    • /
    • 한국방송공학회 2011년도 하계학술대회
    • /
    • pp.333-334
    • /
    • 2011
  • 본 논문에서는 안경식 스테레오스코픽 3DTV에 대한 효율적인 주관적 화질평가 방법에 대한 논의를 한다. 3DTV의 주관적 화질평가는 시각피로나 신체적 불편감을 유발하는 요인들을 규명하고 평가하여 사용자가3D 영상물을 관람할 때 이들을 최소화하면서 컨텐츠 제공자가 의도한 입체 깊이를 시청자가 지각 할 수 있도록 도와 줄 수 있도록 가이드라인을 제공하기 위해 이루어진다. 주관적 화질평가를 위해 적절한 깊이감을 갖는 카메라기반의 실영상과 컴퓨터 그래픽 기반의 3D컨텐츠를 사용하였다. 설문은 디스플레이 자체와 3D컨텐츠에 대한 화질평가 구분을 하고, 전문가와 일반인들을 대상으로 이루어졌다. 주관적 평가에 앞서 평가결과에 대한 객관성을 유지하기 위해 Random-dot Stereogram을 이용하여 개인별 입체시 평가를 하였다. 일반인들의 경우 전문가들에 비해 상대적으로 응답편차가 많이 발생하였으나 전문가 집단과 일반인 집단의 설문응답 경향은 대체적으로 일치하였다. 전문가 그룹의 주관적 평가 결과를 적절히 반영하고 일반인들의 응답편차를 줄임으로써 3DTV에 대한 주관적 평가에 대한 시간과 비용을 효율적으로 줄일 수 있을 것으로 기대된다.

  • PDF

3D TV 시청 환경에서 수렴 훈련에 의한 시각적 불편감의 감소 (Effects of the Convergence Training on Reduction of Visual Discomfort in 3D TV Environment)

  • 감기택;전현민
    • 방송공학회논문지
    • /
    • 제18권5호
    • /
    • pp.738-748
    • /
    • 2013
  • 본 연구는 개인의 불편감을 최소로 유지한 상태에서 3D 자극의 깊이를 늘려나가는 수렴 훈련을 통해 시각적 불편감이 감소되는지를 알아보고자 수행되었다. 실험집단은 수렴 훈련에 사용된 자극의 입체시 깊이가 순차적으로 변화하는지 무선적으로 변화하는지에 따라 두 개의 훈련 집단으로 나뉘었다. 수렴 훈련은 약 2주 간격으로 3회 실시되었으며 훈련 집단의 융합영역(fusional range)을 증가시켰다. 수렴 훈련이 시각적 불편감에 미치는 영향을 평가하기 위해 훈련 회기의 전과 후에 3D 영상을 시청하게 한 뒤, 주관적인 시각적 불편감을 설문 문항으로 측정하였다. 실험 결과, 시각적 불편감은 훈련 자극의 깊이를 순차적으로 변화시킨 훈련집단에서 감소하였다. 이러한 결과는 반복된 수렴 훈련이 3D 환경에서 시각적 불편감을 줄이는 데 효과적일 수 있음을 시사한다.

Augmented System for Immersive 3D Expansion and Interaction

  • Yang, Ungyeon;Kim, Nam-Gyu;Kim, Ki-Hong
    • ETRI Journal
    • /
    • 제38권1호
    • /
    • pp.149-158
    • /
    • 2016
  • In the field of augmented reality technologies, commercial optical see-through-type wearable displays have difficulty providing immersive visual experiences, because users perceive different depths between virtual views on display surfaces and see-through views to the real world. Many cases of augmented reality applications have adopted eyeglasses-type displays (EGDs) for visualizing simple 2D information, or video see-through-type displays for minimizing virtual- and real-scene mismatch errors. In this paper, we introduce an innovative optical see-through-type wearable display hardware, called an EGD. In contrast to common head-mounted displays, which are intended for a wide field of view, our EGD provides more comfortable visual feedback at close range. Users of an EGD device can accurately manipulate close-range virtual objects and expand their view to distant real environments. To verify the feasibility of the EGD technology, subject-based experiments and analysis are performed. The analysis results and EGD-related application examples show that EGD is useful for visually expanding immersive 3D augmented environments consisting of multiple displays.

Effects of Culture Dimensions on Maintenance of Porcine Inner Cell Mass-Derived Cell Self-Renewal

  • Baek, Song;Han, Na Rae;Yun, Jung Im;Hwang, Jae Yeon;Kim, Minseok;Park, Choon Keun;Lee, Eunsong;Lee, Seung Tae
    • Molecules and Cells
    • /
    • 제40권2호
    • /
    • pp.117-122
    • /
    • 2017
  • Despite the fact that porcine embryonic stem cells (ESCs) are a practical study tool, in vitro long-term maintenance of these cells is difficult in a two-dimensional (2D) microenvironment using cellular niche or extracellular matrix proteins. However, a three-dimensional (3D) microenvironment, similar to that enclosing the inner cell mass of the blastocyst, may improve in vitro maintenance of self-renewal. Accordingly, as a first step toward constructing a 3D microenvironment optimized to maintain porcine ESC self-renewal, we investigated different culture dimensions for porcine ICM-derived cells to enhance the maintenance of self-renewal. Porcine ICM-derived cells were cultured in agarose-based 3D hydrogel with self-renewal-friendly mechanics and in 2D culture plates with or without feeder cells. Subsequently, the effects of the 3D microenvironment on maintenance of self-renewal were identified by analyzing colony formation and morphology, alkaline phosphatase (AP) activity, and transcriptional and translational regulation of self-renewal-related genes. The 3D microenvironment using a 1.5% (w/v) agarose-based 3D hydrogel resulted in significantly more colonies with stereoscopic morphology, significantly improved AP activity, and increased protein expression of self-renewal-related genes compared to those in the 2D microenvironment. These results demonstrate that self-renewal of porcine ICM-derived cells can be maintained more effectively in a 3D microenvironment than in a 2D microenvironment. These results will help develop novel culture systems for ICM-derived cells derived from diverse species, which will contribute to stimulating basic and applicable studies related to ESCs.

2D H.264 동영상의 3D 입체 변환 (3D Conversion of 2D H.264 Video)

  • 홍호기;백윤기;이승현;김동욱;유지상
    • 한국통신학회논문지
    • /
    • 제31권12C호
    • /
    • pp.1208-1215
    • /
    • 2006
  • 본 논문에서는 스테레오 카메라로 입체 동영상을 얻는 방법이 아닌 H.264로 압축된 2D 동영상으로부터 복호화 과정에서 얻게 되는 움직임 정보를 이용하여 효과적인 3D 입체 동영상을 생성하는 기법을 제안한다. MPEG 기반의 동영상에서 각 프레임의 움직임 정보는 복호화단에서 얻게 되는 움직임 벡터로 분석이 가능하며 H.264에서는 움직임 예측을 위하여 다양한 크기의 블록을 이용하기 때문에 더 정확한 움직임 벡터와 정보를 얻을 수 있다. 본 논문에서 제안한 2D/3D 변환기법에서는 장면 전환점 검출, delay factor, 운동 방향, 운동 형태 등을 이용하여 좌영상과 우영상을 생성한다. 이때 동일한 컷(cut)내의 프레임들 간의 운동 형태와 운동 방향은 높은 상관도를 가지게 된다. 실험 결과를 통해서 제안된 기법을 이용할 경우 안정된 동영상 입체 변환이 가능함을 알 수 있다.

단백질 가시화 형태에 따른 정보표현적합도 평가 (Evaluation of Information Representation Goodness-of-fit According to Protein Visualization Pattern)

  • 변재희;최유주;서정근
    • 인터넷정보학회논문지
    • /
    • 제16권2호
    • /
    • pp.117-125
    • /
    • 2015
  • 단백질 기능을 규명하는 단백질 구조 정보는 단백질 의약품의 약효를 증진시키고, 개발을 단축시키는데 큰 영향을 미친다. 따라서 단백질의 구조를 효과적으로 분석하기 위한 단백질 가시화에 대한 연구가 증가하고 있다. 하지만 단백질 가시화에 대한 연구가 단백질의 구조를 예측하거나 렌더링의 속도를 향상시키는 것을 중심으로 이뤄지고 있으며, 단백질 가시화 형태에 따른 정보 전달 효용성에 대한 연구는 미비한 실정이다. 본 연구는 단백질 의약품에 대한 효율적인 정보 서비스의 사전 연구로써 단백질 1, 2차구조 혼합가시화 형태별 정보표현적합도를 분석하였다. 단백질 1, 2차구조 혼합가시화 형태는 대표적 가시화 서비스인 Chimera, PDB, Cn3D와 기존 가시화 서비스의 문제점을 개선한 단백질 1, 2차구조 혼합가시화 형태를 대상으로 하였다. 정보표현적합도를 구하기 위한 정보요인은 피험자 분석 결과를 바탕으로 단백질 1차구조, 아미노산 위치, 단백질 2차구조, 단백질 2차구조 비율정보로 구분하였으며, 피험자는 단백질 의약품 업계종사기간이 5년 이상인 전문가 집단을 대상으로 하였다. 그 결과 단백질 1, 2차구조 혼합가시화형태별 정보표현적합도에는 유의미한 차이가 있었으며, 가시화 형태별 정보 전달 효용성에 차이가 있음을 입증할 수 있었다.

깊이정보를 활용한 입체 편집 프로세스 연구 (The study of stereoscopic editing process with applying depth information)

  • 백광호;김민서;한명희
    • 디지털콘텐츠학회 논문지
    • /
    • 제13권2호
    • /
    • pp.225-233
    • /
    • 2012
  • <아바타>이후 3D 입체영상은 차세대 콘텐츠 산업의 블루칩으로 떠올라있다. 그에 반해 국내에서 상업적으로 제작하였던 모든 입체 콘텐츠들이 흥행에 실패 하였다. 이는 국내 입체콘텐츠의 완성도가 해외의 콘텐츠에 비하여 매우 떨어지기 때문이며, 현행되고 있는 2D기반의 입체 후반작업 프로세스가 그 원인으로 작용하고 있다. 그중에서도 입체 편집프로세스는 콘텐츠의 질과 가장 밀접한 관련이 있다. 영화<나탈리>의 제작사례를 통해 알아본 현행 입체 편집프로세스는 2D기반의 시스템을 이용하여 편집을 진행한 후 3D 디스플레이 시스템으로 확인하며 이후 문제가 발생할 경우 수정하는 방식을 취하고 있다. 이러한 현상을 개선하고자 좌 우 영상의 분석을 통해 합성에서 사용되고 있는 변위지도와 깊이지도 등의 깊이정보를 시각화 하여 현행 입체 편집 프로세스에 적용하였으며, 보다 객관성 있는 입체편집 프로세스를 제안하고자 한다. 제안한 프로세스를 실제 뮤직드라마 <기억의 조각>제작에 활용하여 영화<나탈리>와 비교해보았다. 그 결과 <나탈리>의 경우 컷과 컷 사이의 입체 값 변화가 매우 큰 것을 볼 수 있었으나 <기억의 조각>의 경우 입체 값이 전체적으로 균일한 결과를 도출 할 수 있었다. 현행 프로세스의 경우 주관적인 입체감을 바탕으로 하기 때문에 작업자의 컨디션과 상태에 따라 그 값이 달라 질수 있다. 또한 Positive영역에 대한 예상은 할 수 없기 때문에 동일한 공간 혹은 한정된 공간에서 컷에 따라 각기 다른 입체 값을 보임으로써 공간의 입체감을 왜곡시킬 우려가 있다. 반면 깊이정보의 시각화를 활용한 객관적인 입체 편집은 동일한 공간에 대한 입체감과 콘텐츠 전체의 입체감을 균일하게 맞추어 입체 콘텐츠의 질을 높이고, 나아가 입체감 왜곡, 시각적 피로 등의 문제도 동시에 해결 할 수 있다.

3차원 기하를 이용한 스테레오스코픽 비디오의 흔들림 측정 (Camera Shake Estimation of Stereoscopic Video Using 3D Geometry)

  • 김종유;이현호;박상욱;김정환;김학섭;강지우;이상훈
    • 한국방송∙미디어공학회:학술대회논문집
    • /
    • 한국방송공학회 2013년도 하계학술대회
    • /
    • pp.293-295
    • /
    • 2013
  • 최근 3D 비디오의 흥행과 더불어 사람들이 스테레오스코픽 비디오를 쉽게 접할 수 있게 되었다. 하지만 부적절한 스테레오 스코픽 비디오는 시청자로 하여금 어지럼증, 눈의 피로 등을 느끼게 할 수 있다. 따라서 비디오 컨텐츠를 분석하여 피로도를 예츨할 수 있는 지표의 개발이 필요하다. 스테레오스코픽 비디오에서 피로도를 유발시키는 원인은 여러 가지가 있으며, 본 논문에서는 비디오의 카메라 움직임 정보에 집중한다. 카메라의 흔들림은 심각한 멀미를 유발할 수 있다. 이는 스테레오스코픽 비디오에서 더욱 강렬하게 나타나게 된다. 우리는 스테레오스코픽 비디오의 흔들림을 측정하기 위해 3D 복원 기술을 사용한다. 특히, 좌안 비디오와 우안 비디오의 정보를 모두 활용하는 최적화된 알고리즘을 제안한다. 이를 통해 우리는 각 프레임의 카메라 위치와 방향 정보를 획득할 수 있다. 마지막으로 획득한 3차원 카메라 움직임 정보로부터 카메라의 흔들림을 잘 표현할 수 있는 점수를 계산한다.

  • PDF

거리에 따른 집적 영상 복원을 지원하는 에뮬레이터의 구현 (Implementation of an Emulator for the Integrated Image Reconstruction according to Distance)

  • 장하은;이은지;이연주;임순범
    • 한국멀티미디어학회논문지
    • /
    • 제19권3호
    • /
    • pp.548-556
    • /
    • 2016
  • Integral imaging is an auto-stereoscopic display method that can produce 3D image of a finite viewing window through an array of micro elemental lenses. Integral imaging requires the pickup part of each elemental images acquisition and display part of reconstruction of the images. The successful reconstructed image depends on various parameters such as distance between lens arrays and display device, focal length of lenses, and a number of the array. In this paper, we present reconstruction emulator for display of Integral imaging in order to adjust parameters for 3D contents reconstruction and to observe the result from different configuration. Especially, we provide the user interface for the emulator to control the distance easily. We have confirmed through various experiments that the emulator adjusted the distance and could check error in the process of creating elemental images.