• 제목/요약/키워드: 3-D CT image

검색결과 432건 처리시간 0.035초

Evaluation of Images Depending on an Attenuation Correction in a Brain PET/CT Scan

  • Choi, Eun-Jin;Jeong, Mon-Taeg;Dong, Kyung-Rae;Kwak, Jong-Gil;Choi, Ji-Won;Ryu, Jae-Kwang
    • 방사선산업학회지
    • /
    • 제12권4호
    • /
    • pp.267-276
    • /
    • 2018
  • A Hoffman 3D Brain Phantom was used to evaluate two PET/CT scanners, BIO_40 and D_690, according to the radiation dose of CT (low, medium and high) at a fixed kilo-voltage-peak (kVp) with the tube current(mA) varied in 17~20 stages(Bio_40 PET/CT scanner: the tube voltage was fixed to 120 kVp, the effective tube current(mAs) was increased from 33 mAs to 190 mAs in 10 mAs increments, D_690 PET/CT scanner: the tube voltage was fixed to 140 kVp, tube current(mA) was increased from 10 mAs to 200 mAs in 10 mAs increments). After obtaining the PET image, an attenuation correction was conducted based on the attenuation map, which led to an analysis of the difference in the image. First, the ratio of white to gray matter for each scanner was examined by comparing the coefficient of variation (CV) depending on the average ratio. In addition, a blind test was carried out to evaluate the image. According to the study results, the BIO_40 and D_690 scanners showed a <1% change in CV value due to the tube current conversion. The change in the coefficients of white and gray matter showed that the Z value was negative for both scanners, indicating that the coefficient of gray matter was higher than that of white matter. Moreover, no difference was observed when the images were compared in a blind test.

Quantitative Measurements of 3-D Imaging with Computed Tomography using Human Skull Phantom

  • Kim, Dong-Wook;Kim, Hee-Joung;Haijo Jung;Soonil Hong;Yoo, Young-Il;Kim, Dong-Hyeon;Kim, Kee-Deog
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.506-508
    • /
    • 2002
  • As an advancement of medical imaging modalities and analyzing software with multi-function, active researches to acquire high contrast and high resolution image being done. In recently, development of medical imaging modalities like as Computed Tomography (CT) and Magnetic Resonance Imaging (MRI) is aiming to display anatomical structure more accuracy and faster. Thus, one of the important areas in CT today is the use of CT scanner for the quantitative evaluation of 3-D reconstruction images from 2-D tomographic images. In CT system, the effective slice thickness and the quality of 3-D reconstructed image will be influenced by imaging acquisition parameters (e.g. pitch and scan mode). In diagnosis and surgical planning, the accurate distance measurements of 3-D anatomical structures play an important role and the accuracy of distance measurements will depend on the acquisition parameters such as slice thickness, pitch, and scan mode. The skull phantom was scanned with SDCT for various acquisition parameters and acquisition slice thicknesses were 3 and 5 mm, and reconstruction intervals were 1, 2, and 3 mm to each pitch. 3-D visualizations and distance measurements were performed with PC based 3-D rendering and analyzing software. Results showed that the image quality and the measurement accuracy of 3-D SDCT images are independent to the reconstruction intervals and pitches.

  • PDF

디지털 재구성 방사선영상과 온보드 영상장치를 이용한 2D-2D 정합 시 디지털 재구성 방사선영상의 질이 정합 정확도에 미치는 영향 분석 (Analysis of Uncertainties due to Digitally Reconstructed Radiographic (DRR) Image Quality in 2D-2D Matching between DRRs and kV X-ray Images from the On-Board Imager (OBI))

  • 정광호;조병철;강세권;김경주;배훈식;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제17권2호
    • /
    • pp.67-76
    • /
    • 2006
  • 본 연구에서는 환자 치료 전 셋업 확인을 위해 디지털 재구성 방사선영상(digitally reconstructed radiographs, DRR)을 참조영상으로 하여 온보드 영상 장치로부터 획득된 kV X선 영상과의 2차원 정합을 수행하였을 경우 DRR 영상의 질에 따라 환자 셋업 오차 보정의 정확도가 어떻게 달라지는가를 확인하였다. 방사선치료계획 장치로는 Pinnacle3와 Eclipse를 이용하였으며 참조 영상으로는 팬텀 및 환자를 각각 다른 슬라이스 두께로 부위별로 CT 촬영한 영상으로부터 재구성된 DRR 영상을 이용하였다. DRR 영상 및 프로파일 비교에서는 CT 슬라이스 두께가 증가함에 따라 이를 이용한 DRR 영상의 질이 저하됨을 확인할 수 있었지만 2차원 정합 결과 유사한 오차 값을 보여주어 DRR 영상의 질이 큰 영향을 미치지 않음을 확인할 수 있었다. 슬라이스 두께에 따른 2차원 정합 결과의 차이가 크지는 않지만 일반적인 환자 치료계획 및 2차원 정합을 위해 슬라이스 두께 3 mm 이하의 CT 영상 획득이 필요할 것으로 생각한다.

  • PDF

폐암의 정위적체부방사선치료시 호흡 움직임에 따른 3D 선량 측정평가 (A study to 3D dose measurement and evaluation for Respiratory Motion in Lung Cancer Stereotactic Body Radiotherapy Treatment)

  • 최병걸;최창헌;윤일규;양진성;이동명;박주미
    • 대한방사선치료학회지
    • /
    • 제26권1호
    • /
    • pp.59-67
    • /
    • 2014
  • 목 적 : 폐암의 정위적체부방사선치료시 실제 적용하고 있는 최대강도투사(MIP) 영상과 호흡위상별(0~90%)영상에서 3차원적으로 재구성된 선량 분포 차이를 평가하고자 한다. 대상 및 방법 : 본원에서 정위적체부방사선치료를 시행한 비소세포성 폐암(NSCLC) 환자 5명을 대상으로 4차원 전산화단층영상을 시행하여 10개의 호흡위상별 영상을 획득한 후 최대강도투사 영상을 재구성하여 각 호흡위상별 치료계획을 수립하였고, 2차원 이온전리함과 선량분석프로그램 COMPASS(IBA dosimetry, Schwarzenbruck, Germany)을 이용하여 3차원적으로 재구성된 선량분포를 측정하였다. 이를 이용하여 치료계획 선량분포와 실제 측정 선량분포의 일치성 여부 및 최대강도투사 영상과 호흡위상별 영상에서 선량 분포의 차이를 정량적으로 비교 분석하였다. 결 과 : 최대강도투사 영상 및 호흡위상별 영상에서의 선량분포의 일치성을 알아보기 위한 감마분석 통과율은 대상 환자 모두 99%이상으로 평가기준을 만족 시켰으며, 각각의 환자들에 대한 최대강도투사 영상과 호흡위상별 영상에서 재구성된 선량의 HI(Homogeneity Index) 차이의 평균은 -0.03~0.04로 크지 않았으며, PTV(Planning Target Volume)의 Dmax 차이는 평균 3.30 cGy, 척수는 평균 40 cGy, 양측 폐, 우폐, 좌폐의 $V_{20}$, $V_{10}$, $V_5$ 차이는 평균 -0.04~2.32% 차이를 나타내었다. 또한 모든 환자에 대한 최대강도투사 영상과 호흡위상별 영상에서 재구성된 선량의 HI 차이의 평균은 -0.03~0.03로 크지 않았으며, PTV의 Dmax 차이의 평균은 10% 영상에서 가장 차이가 작았고, 70% 영상에서 가장 큰 차이를 나타내었다. 척수의 Dmax차이의 평균은 50% 영상에서 가장 차이가 작았고, 0% 영상에서 가장 큰 차이를 나타내었다. 폐 $V_{20}$, $V_{10}$, $V_5$의 차이의 평균은 호흡위상별로 일정한 경향성을 나타내지 않았다. 결 론 : 본 연구를 통해 최대강도투사 영상과 각 호흡위상별 영상에서 측정되어 3차원적으로 재구성된 선량분포차이는 일정한 경향을 나타내지는 않았지만 특정 호흡위상에서 선량 분포 차이가 상이한 경우를 볼 수 있었다. 종양의 위치 및 호흡 움직임이 유사한 대상환자군을 선정하여 체계적인 연구를 통해 데이터화 하게 되면 폐와 같이 움직임이 큰 장기의 정위적체부방사선치료시 특정 호흡위상에서 획득한 영상에서의 치료계획이 실제 치료에 적용되어야 하는지에 대한 적합성 여부를 판단 할 수 있을 것이라고 사료된다.

Evaluation of accuracy of 3D reconstruction images using multi-detector CT and cone-beam CT

  • Kim, Mi-Ja;Huh, Kyung-Hoe;YI, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • 제42권1호
    • /
    • pp.25-33
    • /
    • 2012
  • Purpose : This study was performed to determine the accuracy of linear measurements on three-dimensional (3D) images using multi-detector computed tomography (MDCT) and cone-beam computed tomography (CBCT). Materials and Methods : MDCT and CBCT were performed using 24 dry skulls. Twenty-one measurements were taken on the dry skulls using digital caliper. Both types of CT data were imported into OnDemand software and identification of landmarks on the 3D surface rendering images and calculation of linear measurements were performed. Reproducibility of the measurements was assessed using repeated measures ANOVA and ICC, and the measurements were statistically compared using a Student t-test. Results : All assessments under the direct measurement and image-based measurements on the 3D CT surface rendering images using MDCT and CBCT showed no statistically difference under the ICC examination. The measurements showed no differences between the direct measurements of dry skull and the image-based measurements on the 3D CT surface rendering images (P>.05). Conclusion : Three-dimensional reconstructed surface rendering images using MDCT and CBCT would be appropriate for 3D measurements.

Personal Computer를 이용한 3차원적 뇌정위적 방사선 치료계획 (3-D Radiosurgery Planning Using Personal Computer)

  • 서태석;서덕영;박찬일;하성환;강위생
    • 한국의학물리학회지:의학물리
    • /
    • 제3권1호
    • /
    • pp.63-69
    • /
    • 1992
  • 최근 3차원적인 영상 데이타 및 방사선량 분포에 대한 정보를 필요로하는 뇌정위적 방사선 치료계획이 절실히 요구되고 있다. 본 연구의 목적은 personal computer를 이용하여 3차원적인 환자영상 데이터 및 선량분포를 함께 처리할 수 있는 치료계획 시스템을 개발하는 데 있다. 본 연구를 위한 처리 과정은 크게 3단계로 나누어 수행된다. 첫째, 환자영상 데이타 입력과정으로서, CT, MRI 등 단층촬영영상을 on-line 및 digitizer 방식을 통하여 personal computer에 입력시킨다 병소위치 및 모양도 Angio 및 CT localization 방법을 이용하여 함께 입력시킨다. 둘째, 선량계산 단계로서, stereotactic frame 좌표로 변환된 영상내에서 선량 분포를 계산하고 환자영상 데이타 및 치료기의 조사조건등에 따라 최적 선량분포를 얻는다. 셋째, display 과정으로서, 임의의 단층영상 및 재구성 영상내에서 환자영상과 방사선량에 대한 영상을 합성하여 computer monitor를 통하여 단일 영상내에 동시에 묘출할 수 있도록 처리한다. 본 연구의 치료계획 시스템을 응용한 바 치료계획을 신속하고 정확하게 처리할 수 있었으며, Angio, CT 혹은 MRI와 같은 여러형태의 영상내에서 선량분포를 동시에 묘출함으로써 능률적인 치료계획을 세울 수 있었다. 이와같은 치료계획의 자동화 시스템은 지금까지 어려웠던 3차원적인 뇌정위적 방사선치료계획을 가능케 하며, 추후 beam's eye view나 CT simulation을 통한 일반적인 3차원 방사선 치료계획에도 크게 이바지할 것으로 기대된다.

  • PDF

대퇴 골두 충돌 증후군(Cam type)의 진단과 치료를 위한 자기공명 3D 영상 재구성 기법의 유용성 (Usefulness of MRI 3D Image Reconstruction Techniques for the Diagnosis and Treatment of Femoral Acetabular Impingement Syndrome(Cam type))

  • 곽영곤;김종일;조영기
    • 한국콘텐츠학회논문지
    • /
    • 제15권11호
    • /
    • pp.313-321
    • /
    • 2015
  • Hip FAI 진단과 수술 계획 시 Hip FAI MRI 검사시 3D 영상을 추가로 활용하여 CT 영상으로 이루어지는 Hip Clock face 영상을 MRI 3D 영상으로 대체할 수 있는지 비교 평가 하였다. Hip 자기공명 영상검사(MRI)와 3D Hip 컴퓨터 단층 촬영(CT)을 동시 시행한 환자 31명 (남: 21명 평균연령: 35세 여: 10명 평균연령: 40.3세)을 대상으로 분석하였으며, 영상평가는 정형외과 전문의 1명과 영상의학과 전문의 1명이 MR과 CT modality에서 Hip joint articular transverse ligament의 6 o'clock을 중심으로 Superior을 12 o'clock, Labrum의 전면을 3 o'clock, 반대쪽을 9 o'clock로 기술하는 Clock face을 재구성 한 후 11 o'clock에서 A. retinacular vessel, B. head neck junction, 12 o'clock A. Epiphyseal line, B. Cam lesion, 1,2,3,4 o'clock의 Cam lesion, Posterior Cam lesion확인 여부를 리커트(Likert scale) 5점 척도로 평가하였다(Independent t-test p<0.05). 리커드 척도 결과 11 o'clock A. retinacular vessel MR 평균 값 $3.69{\pm}1.0$, CT 평균값 $2.8{\pm}0.78$이며 통계적으로 유의하였다(p<0.001). B. head neck junction은 두 평가자간 차이가 없었다(p<0.416). 12 o'clock A. Epiphyseal line MR 평균값 $3.54{\pm}1.00$, CT 평균값 $4.5{\pm}0.62$이었다(p<0.000). B. Cam lesion은 두 평가자간 차이가 없었다(p<0.532). 1,2,3,4 o'clock 의 Cam lesion과 Posterior Cam lesion은 통계적으로 유의하지 않았다(p<0.656, p<0.658). weighted Kappa 검증 결과 11 o'clock A.retinacular vessel CT K값이 0.663으로 가장 낮은 일치도였으며, 각각의 평가 항목의 일치도 평가 결과 매우 높은 결과로 두 평가자간 높은 신뢰도를 보여주었다.

초고속 정보통신망을 통한 3차원 영상 정보의 가상현실 관리에 관한 연구 (A Study on Virtual Reality Management of 3D Image Information using High-Speed Information Network)

  • 김진호;김지인;장천현;송상훈
    • 한국정보처리학회논문지
    • /
    • 제5권12호
    • /
    • pp.3275-3284
    • /
    • 1998
  • 본 논문에서는 각종 단층 촬영 의료영상 장비로 촬영한 2차원 단면화상 데이터들을 차원 재구성 알고리즘을 사용하여 3차원 영상으로 재구성한 다음, 웹 서버의 데이터베이스에 저장하고 관리하며, 인터넷 가상현실 표준언어인 VRML(Virtual Reality Modeling Language)로 표현된 3차원 의료영상을 비롯한 각종 의료영상 정보를 웹브라우저를 사용하여 검색해 볼 수 있는 의료영상정보시스템(Medical Image Information System)에 관하여 기술한다. 본 연구를 통하여 개발한 의료영상정보시스템에서는 단층 촬영된 2차원 단면화상을 처리한 다음, 3차원 의료 영상을 생성하기 위하여 표면기반 랜더링 방법(Surface-based Rendering Method)을 사용하였다. 인터넷을 통하여 전송되는 영상파일의 크기를 줄이기 위하여 삼각형 매쉬(Triangle Meshes)을 이루는 다각형의 개수를 줄이는 알고리즘을 사용하며, 3차원 의료영상 데이터의 크기를 약 50%이상 줄일 수 있다. 아울러, 3차원 영상 데이터 파일을 압축을 하게 되면 파일의 크기를 80%이상 줄일 수 가 있으므로 웹상에서 신속하게 3차원 의료영상 데이터를 검색할 수 있고, 의료영상을 VRML을 사용하여 표현하므로 고성능의 그래픽 카드가 없는 일반 PC에서도 인터넷을 통하여 디스플레이 할 수 있다. 또한, CGI(Common Gateway Interface)방식을 사용하여 서버의 데이터베이스에 저장되어 있는 CT(Computerized Tomography), MRI(Magnetic Resonance Imaging), PET(Positron Emission Tomography), SPECT(Single Photon Emission Computed Tomography)등의 단층 촬영 장비로 촬영한 다양한 종류의 디지털 의료영상을 사용자에게 의료영상정보시스템을 통하여 2차원 단면화상 또는 3차원 영상으로 표현하여 보여주고, 환자에 관한 각종 정보와 진단정보 등을 신속하게 제공한다. 본 논문에서 제안하는 의료영상정보시스템은 초고속 정보통신 망을 통하여 원격의료시스템을 구축하는데 활용될 수 있을 것이다.

  • PDF

PET/CT 2D와 3D 영상 획득에서 방사능 집적에 따른 방사능 농도의 평가 (Evaluation of Radioactivity Concentration According to Radioactivity Uptake on Image Acquisition of PET/CT 2D and 3D)

  • 박선명;홍건철;이혁;김기;최춘기;석재동
    • 핵의학기술
    • /
    • 제14권1호
    • /
    • pp.111-114
    • /
    • 2010
  • 양전자 방출 단층촬영은 세포의 생화학적 변화에 따른 방사성의약품의 집적 정도를 영상화함으로서 암을 조기에 진단할 수 있는 검사방법으로 알려져 있다. 이러한 집적 정도는 여러 가지 원인에 따라 발생될 수 있는 것으로 $^{18}F$-FDG 주사량, 종양의 크기, 혈중 포도당 농도 등이 있다. 본 연구에서는 집적방사능과 2D와 3D 영상 획득이 방사능 농도(kBq/mL)에 미치는 영향에 대하여 평가하고자 한다. GE Discovery STe 16 PET/CT에서 1994 NEMA PET phantom을 이용하였으며, 배후방사능과 열소의 방사능 농도비가 1:2, 1:4, 1:8, 1:10, 1:20, 1:30 표준이 되도록 하여 2D와 3D로 영상을 획득하였다. 재구성 방법으로 2D와 3D 모두에서 반복연산법으로 반복횟수 2회, 부분집합 20을 적용하였다. 그리고 CT 감쇠보정법과 획득 시간은 10분으로 설정하였다. 또한 영상분석은 열소의 중심과 배후방사능에 동일한 관심영역을 설정 한 후 각 부분의 방사능 농도를 측정하여 비교 분석하였다. 설정된 관심영역의 배후방사능과 열소의 방사능 농도 비는 2D에서 1:1.93, 1:3.86, 1:7.79, 1:8.04, 1:18.72, 1:26.90, 3D는 1:1.95, 1:3.71, 1:7.10, 1:7.49, 1:15.10, 1:23.24 값을 얻었다. 또한 표준 방사능 농도비를 기준으로 한 백분율 차이(% Difference)는 2D에서 3.50%, 3.47%, 8.12%, 8.02%, 10.58%, 11.06%로 최소 3.47%에서 최대 11.06% 차이가 있고 3D는 3.66%, 4.80%, 8.38%, 23.92%, 23.86%, 22.69%로 최소 3.66%에서 최대 23.92%까지의 차이를 나타냈다. 방사능 농도가 증가할수록 실제 집적된 방사능 농도의 차이가 커짐을 알 수 있으며, 2D가 3D보다 평균 약 10.6% 높게 집적되어 방사능 농도 변화에 영향을 적게 받는 것으로 나타났다. 따라서 임상환자의 추적 검사에서 영상 획득 방법을 변화할 시 정확한 정량 평가를 위해서 이점을 고려하여 적용하여야 한다.

  • PDF

부분영역처리를 이용한 영상재구성의 속도개선에 관한 연구 (A Study on Speed Improvement of Medical Image Reconstruction Using Limited Range Process)

  • 유종현;백승화
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권5호
    • /
    • pp.658-663
    • /
    • 1999
  • 2D sliced CT images hardly express the human disease in a space. This space expression can be reconstructed into 3D image by piling up the CT sliced image in succession. In medical image, in order to get the reconstructed 3D images, expensive system or much calculation time is needed. But by changing the method of reconstruction procedure and limit the range, the reconstruction time could be reduced. In this study, to reduce the processing time and memory, we suggested a method of interpolation and ray casting processing at the same time in a limited range. Such a limited range processing have advantages that we could reduce the unnecessary interpolation and ray casting. Through a experiment, it is founded that the reconstruction time and the memory was much reduced.

  • PDF