• Title/Summary/Keyword: 3 dimensional evaluation

Search Result 1,179, Processing Time 0.032 seconds

A reliability measure of three dimensional shapes based on statistical shape analysis (통계적 형상분석을 이용한 3차원 형상의 신뢰도 계수)

  • Shin, Sang Min
    • The Korean Journal of Applied Statistics
    • /
    • v.32 no.1
    • /
    • pp.15-27
    • /
    • 2019
  • The reliability of the data means the overall consistency of the measurement results. Methods for evaluating reliability have been continuously studied because it affects the results of the statistical analysis. Cronbach's ${\alpha}$ coefficient or intraclass correlation coefficient is used for reliability evaluation; however, these measures cannot be applied to data consisting of three-dimensional coordinates to represent an object. In this study, we propose a measure to evaluate the reliability of three dimensional shapes based on statistical shape analysis that is made possible by extracting the shape information from the measured three dimensional coordinates and decomposing the shape variation.

Development of Facial Palsy Grading System with Three Dimensional Image Processing (3차원 영상처리를 이용한 안면마비 평가시스템 개발)

  • Jang, M.;Shin, S.H.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.9 no.2
    • /
    • pp.129-135
    • /
    • 2015
  • The objective grading system for the facial palsy is needed. In this study, the facial palsy grading system was developed with combination of three dimensional image processing and Nottingham scale. The developed system is composed of 4 parts; measurement part, image processing part, computational part, facial palsy evaluation & display part. Two web cam were used to get images. The 8 marker on face were recognized at image processing part. The absolute three dimensional positions of markers were calculated at computational part. Finally, Nottingham scale was calculated and displayed at facial palsy evaluation & display part. The effects of measurement method and position of subject on Nottingham scale were tested. The markers were measured with 2-dimension and 3-dimension. The subject was look at the camera with $0^{\circ}$ and $11^{\circ}$ rotation. The change of Scale was large in the case of $11^{\circ}$ rotation with 2-dimension measurement. So, the developed system with 3-dimension measurement is robust to the orientation change of subject. The developed system showed the robustness of grading error originated from subject posture.

  • PDF

Sensitivity Analysis of 3-Dimensional FE Models for Jointed Concrete Pavements (줄눈 콘크리트포장 3차원 유한요소모델의 민간도 분석)

  • Yoo, Taeseok;Sim, Jongsung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.3D
    • /
    • pp.435-444
    • /
    • 2006
  • This paper investigates the effect of 3-dimensional FE models to evaluation results of jointed concrete pavements which is back-calculated by AREA method. Sensitivity of 3-dimensional FE models developed to simulate the behavior of real jointed concrete pavement are analyzed after compared with 2-dimensional FE models using ILLISLAB. In comparison with 2-dimensional models, influence of concrete contraction under loading plate and base layer on surface deflections is more than that of loading configuration. Deflections at 3-dimensional model between linear and nonlinear temperature distribution under same temperature difference are similar, but noticeable differences are investigated in low elastic modulus of foundations. Dynamic deflections under loading plate are larger than static deflections in high elastic modulus of foundation, but smaller in low elastic modulus. Lower dynamic modulus of subgrade reactions are backcalculated by dynamic deflections than by static deflections. But reverse trend is investigated in the backcalculated elastic modulus of concrete which describes trends of the field backcalculation values calculated from AREA method.

Development of a Rigid-ended Beam Element and Its Application to Simplify 3-Dimensional Analysis of Bracketed Frame Structures (강체 단부 보요소의 개발 및 브라켓이 있는 골조 구조의 3차원 해석 단순화를 위한 적용)

  • Seo, Seung Il;Lim, Seong Joon
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.34 no.3
    • /
    • pp.76-84
    • /
    • 1997
  • At the initial design stage, for rapid evaluation of strength of ship structures, finite element analysis using beam elements is carried out in general. In beam modeling of ship structures, brackets are usually represented by rigid elements to simplify the analysis. Extent of rigid ends, which is called as a span point, can be determined from the three kinds of view points, i.e., bending, shearing and axial deformation. In this paper, a 2-dimensional novel beam element is developed and a method to replace the 3-dimensional analysis with 2-dimensional analysis is proposed. The developed novel beam element named rigid-ended beam element can consider the effect of three kinds of span points within one element, which was impossible in modeling with the ordinary beam element. Calculated results for the portal frame using the rigid-ended beam element agree with the results using membrane elements. And also, the proposed semi 3-dimensional analysis method which includes two step analysis using influence coefficients shows good accuracy. Structural analysis using the rigid-ended beam element and the semi 3-dimensional method is revealed to have good computing efficiency due to unnecessity of elements corresponding to the brackets and simplification of 3-dimensional analysis.

  • PDF

Three-dimensional evaluation on the repeatability and reproducibility of dental scanner-based digital models (치과용 스캐너로 채득한 디지털 모형의 반복성 및 재현성에 관한 3차원적 평가)

  • Lee, Gyeong-Tak;Kim, Jae-Hong;Kim, Woong-Chul;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.34 no.3
    • /
    • pp.213-220
    • /
    • 2012
  • Purpose: The aim of this study was to determine the repeatability and reproducibility of two dental scanners. Methods: The master die and the stone replicas(Kavo, Germany) were digitized in touch-probe scanner(Incise, Renishaw, UK), white light scanner(Identica, Medit, Korea) to create 3-dimensional surface-models. The number of points in the point clouds from each reading were calculated and used as the CAD reference model(CRM). Discrepancies between the points in the 3-dimensional surface models and the corresponding CRM were measured by a matching-software(Power-Inspect R2, Delcam Plc, UK). The t-student test for one samples were used for statistical analysis. Results: The reproducibility of both scanner was within $3{\mu}m$, based on mean value. The mean value between measurements made directly on the touch probe scanner digital models and those made on the white light scanner digital models was $2.20-2.90{\mu}m$, and was statistically significant(P<0.05). Conclusion: With respect to adequate data acquisition, the reproducibility of dental scanner differs. Three-dimensional analysis can be applied to differential quality analysis of the manufacturing process as well as to evaluation of different analysis methods.

The application of GIS in analyzing acoustical and multidimensional data related to artificial reefs ground (인공어초 어장에서 수록한 음향학적 다차원 데이터 해석을 위한 GIS의 응용)

  • Kang, Myoung-Hee;Nakamura, Takeshi;Hamano, Akira
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.47 no.3
    • /
    • pp.222-233
    • /
    • 2011
  • This study is for the multi-dimensional analysis of diverse data sets for artificial reefs off the coast of Shimonoseki, Yamaguchi prefecture, Japan. Various data sets recorded in artificial reefs ground were integrated in new GIS software: to reveal the relationships between water temperature and fish schools; to visualize the quantitative connection between the reefs and the fish schools; and to compare the seabed types derived from two different data sources. The results obtained suggest that the application of GIS in analyzing multi-dimensional data is a better way to understand the characteristics of fish schools and environmental information around artificial reefs and particularly in the evaluation of the effectiveness of artificial reefs.

Frankfort horizontal plane is an appropriate three-dimensinal reference in the evaluation of clinical and skeletal cant

  • Oh, Suseok;Ahn, Jaemyung;Nam, Ki-Uk;Paeng, Jun-Young;Hong, Jongrak
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.39 no.2
    • /
    • pp.71-76
    • /
    • 2013
  • Objectives: In three-dimensional computed tomography (3D-CT), the cant is evaluated by measuring the distance between the reference plane (or line) and the tooth. The purpose of this study was to determine the horizontal skeletal reference plane that showed the greatest correlation with clinical evaluation. Materials and Methods: The subjects were 15 patients who closed their eyes during the CT image taking process. The menton points of all patients deviated by more than 3 mm. In the first evaluation, clinical cant was measured. The distance from the inner canthus to the ipsilateral canine tip and the distance from the eyelid to the ipsilateral first molar were obtained. The distance between the left and right sides was also measured. In the second evaluation, skeletal cant was measured. Six reference planes and one line were used for the evaluation of occlusal cant: 1) FH plane R: Or.R - Or.L - Po.R; 2) FH plane L: Or.R - Or.L - Po.L; 3) F. Ovale plane R: Rt.F.Ovale - Lt.F.Ovale - Or.R; 4) F. Ovale plane L: Rt.F.Ovale - Lt.F.Ovale - Or.L; 5) FZS plane R: Rt.FZS - Lt.FZS - Po.R; 6) FZS plane R: Rt.FZS - Lt.FZS - Po.L, and; 7) FZS line: Rt.FZS - Lt.FZS. Results: The clinical and skeletal cants were compared using linear regression analysis. The FH plane R, FH plane L, and FZS line showed the highest correlation (P<0.05). Conclusion: The FH plane R and FH plane L are the most appropriate horizontal reference plane in evaluation of occlusal cant on 3D-CT.

Computational strategies for improving efficiency in rigid-plastic finite element analysis (강소성 유한요소해석의 안정화와 고능률화에 관한 연구)

  • ;;Yoshihiro, Tomita
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.3
    • /
    • pp.317-322
    • /
    • 1989
  • Effective computational strategies have been proposed in the evaluation of stiffness matrices of rigid-plastic finite element method widely used in simulation of metal forming processes. The stiffness matrices are expressed as the sum of stiffness matrices evaluated by reduced integration and Liu's stabilization matrices which control the occurrence os zero-energy mode due to excessive reduced integration. The proposed method has been applied to the solution of fundamental 3-dimensional problems. The results clarified that the deformed mesh configuration was remarkably stabilized and computation speed attained about 3 times as fast as that of conventional 3-dimensional analyses. Furthermore, computation speed increases by a factor 60 when parallel computation is introduced. This speed has a tendency to increase as the total degree of freedom increases. As a result, this rigid-plastic finite element method enables us to analyze real 3-dimensional forming processes with practically acceptable computation time.

Accuracy and reliability of 2-dimensional photography versus 3-dimensional soft tissue imaging

  • Ayaz, Irem;Shaheen, Eman;Aly, Medhat;Shujaat, Sohaib;Gallo, Giulia;Coucke, Wim;Politis, Constantinus;Jacobs, Reinhilde
    • Imaging Science in Dentistry
    • /
    • v.50 no.1
    • /
    • pp.15-22
    • /
    • 2020
  • Purpose: This study was conducted to objectively and subjectively compare the accuracy and reliability of 2-dimensional(2D) photography and 3-dimensional(3D) soft tissue imaging. Materials and Methods: Facial images of 50 volunteers(25 males, 25 females) were captured with a Nikon D800 2D camera (Nikon Corporation, Tokyo, Japan), 3D stereophotogrammetry (SPG), and laser scanning (LS). All subjects were imaged in a relaxed, closed-mouth position with a normal smile. The 2D images were then exported to Mirror® Software (Canfield Scientific, Inc, NJ, USA) and the 3D images into Proplan CMF® software (version 2.1, Materialise HQ, Leuven, Belgium) for further evaluation. For an objective evaluation, 2 observers identified soft tissue landmarks and performed linear measurements on subjects' faces (direct measurements) and both linear and angular measurements on all images(indirect measurements). For a qualitative analysis, 10 dental observers and an expert in facial imaging (subjective gold standard) completed a questionnaire regarding facial characteristics. The reliability of the quantitative data was evaluated using intraclass correlation coefficients, whereas the Fleiss kappa was calculated for qualitative data. Results: Linear and angular measurements carried out on 2D and 3D images showed excellent inter-observer and intra-observer reliability. The 2D photographs displayed the highest combined total error for linear measurements. SPG performed better than LS, with borderline significance (P=0.052). The qualitative assessment showed no significant differences among the 2D and 3D imaging modalities. Conclusion: SPG was found to a reliable and accurate tool for the morphological evaluation of soft tissue in comparison to 2D imaging and laser scanning.

Stability Evaluation of Multi-storied Stone Pagoda in the Daewonsa Temple using Three-dimensional Image Analysis (3차원 영상분석을 이용한 대원사다층석탑의 안정성 평가)

  • Jun, Byung-Kyu;Lee, Chan-Hee;Suh, Man-Cheol
    • Journal of Conservation Science
    • /
    • v.22
    • /
    • pp.31-42
    • /
    • 2008
  • A stone cultural heritage often lacks design drawing and detailed geometric informations, thus it becomes more difficult to conservation and restoration. Even though there is active database of detail shape information and numerical measurement for stone monuments, most of the data is in hard-to-utilize two-dimensional images. The new technology developed to overcome this problem is three-dimensional image scanning system. The multi-storied stone pagoda of the Daewonsa temple was analysed with 3D scanning image data then survey map with orientation displacement was evaluated. The difference of each side became apparent with the members of the stone properties was measured, also horizontal and vertical displacement occurred. Horizontal displacement occurred in increasing severity from left to right and from body section to upper part. The 8th roof stones are leaning toward northwest direction due to lateral displacement. The evaluation and measurement of displacement could cause a little errors due to the characteristics uneven surface of stone monuments, computer program and mistakes from the researcher. In future, more precise measurement and stability studies should be done to suggest that accurate data for conservation and understanding of damage condition can be provided.

  • PDF