• Title/Summary/Keyword: 3 Level Converter

Search Result 279, Processing Time 0.028 seconds

Design, Implementation and Test of Flight Model of S-Band Transmitter for STSAT-3 (과학기술위성 3호 S-대역 송신기 비행모델 설계, 제작 및 시험)

  • Oh, Seung-Han;Seo, Gyu-Jae;Lee, Jung-Soo;Oh, Chi-Wook;Park, Hong-Young
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.39 no.6
    • /
    • pp.553-558
    • /
    • 2011
  • This paper describes the development and test result of S-band Transmitter flight model(FM) of STSAT-3 by satellite research center(SaTReC), KAIST. The communication sub-system of STSAT-3 is consist of two different frequency band channels, S-band for Telemetry & Command and X-band for mission data. S-band Transmitter(STX) functionally made of modulator, frequency synthesizer, power amp and DC/DC converter. The transmission data is modulated by FSK(Frequency Shift Keying) and the interface between spacecraft sub-module and STX is RS-422 standard method. The FM STX is based on modular design. The RF output power of STX is 1.5W(31.7dBm) and BER of STX is under $1{\times}10^{-5}$ which meets the specification respectively. The FM STX is delivered Spacecraft Assembly, Integration and Test(AIT) level through the completion of functional Test and environmental(vibration, thermal vacuum) Test successfully.

Characteristics of Hazardous Volatile Organic Compounds (HVOCs) at Roadside, Tunnel and Residential Area in Seoul, Korea (서울시 도로변, 터널 및 주거지역 대기 중 유해 휘발성 유기화합물의 특성)

  • Lee, Je-Seung;Choi, Yu-Ri;Kim, Hyun-Soo;Eo, Soo-Mi;Kim, Min-Young
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.5
    • /
    • pp.558-568
    • /
    • 2011
  • Hazardous volatile organic compounds (HVOCs) have been increasingly getting concern in urban air chemistry due to photochemical smog as well as its toxicity or potential hazards. In this study, we investigated their concentrations and the properties in tunnel, urban roadside and residential area. As a result, among 36HVOCs measured in this study, BTEX (benzene, toluene, ethylbenzene, xylene) and dichlorodifluoromethane, 1,2,4-trimethylbenzene, trichlorofluoromethane were detected above the concentration of $1{\mu}g/m^3$ in every sampling site and the most abundant compound was toluene. The other compounds were detected at trace level or below the detection limit. In addition, we found that three CFCs (chlorofluorocarbons), such as CFC-12, CFC-11, CFC-113, were persistently detected because of the emission in the past. Toluene to benzene ratio (T/B) at tunnel and roadside were calculated to be 4.3~5.3 and at residential area 15.4, suggesting that the residential area had several emission sources other than car exhaust. The ratio of X/E (m,p-xylene to ethylbenzene) ratio was calculated to be 1.8~2.1 at tunnel, 1.7 at roadside and 1.2 at residential area, which means this ratio reflected well the relative photochemical reactivity between these compounds. Good correlation between m,p-xylene and ethylbenzene ($r^2$ > 0.85) were shown in every study sites. This indicated that correlation between $C_2$-alkylbenzenes were not severely affected by 3-way catalytic converter. In this study, it was demonstrated that the concentration of benzene was very low, compared with national air quality standard (annual average of $5{\mu}g/m^3$). Its concentration were $2.52{\mu}g/m^3$ in roadside and $1.34{\mu}g/m^3$ in residential area. We thought this was the result of persistent policy implementation including the reduction of benzene content in gasoline enforced on January 1, 2009.

Removal of Aqueous Cyanide through the Utilization of Industrial By-products (산업부산물(제강 Sludge, 제강 Slag)을 이용한 시안 흡착 제거)

  • 이정원;현재혁;조재범
    • Journal of Korea Soil Environment Society
    • /
    • v.3 no.2
    • /
    • pp.89-99
    • /
    • 1998
  • Sorption of the aqueous cyanide onto steel mill sludge and steel mill slag, both of which are the by-products from the converter furnace, was studied. In the study, the influence of temperature, activation energy, concentration and pH on sorption of cyanide was investigated. Three different temperature($25^{\circ}C$ > $37^{\circ}C$> $50^{\circ}C$) was chosen to represent that of landfill leachate. Initial concentration was 1 mg/$\ell$ 5 mg/$\ell$, 10 mg/$\ell$, and 20 mg/$\ell$. In addition, pH was set to three different level, that is, 3, 7, and 11 respectively. As the result of batch mode experiment for cyanide adsorption, the removal rate was found to be proportional to the initial concentration of cyanide. The order of removal rate was 20 mg/$\ell$> 10 mg/$\ell$> 5 mg/$\ell$> 1 mg/$\ell$. Similarly the influence of pH was proportional because of the change in solubility of cyanide. The order of removal rate was pH 11 > pH 7 > pH 3. As the temperature increased, so did the removal rate. The reaction was endothermic and the value of activation energy(Ea) was 127.93 J/mole and 59.44 J/mole respectively at 1 mg/ιand 20 mg/ιof initial concentration. From the experiment, it can be postulated that the capability of steel mill by-products to attenuate aqueous cyanide is enough to be used as substitute for clay liner of landfill site in the aspect of pollutant removal.

  • PDF

Design and Fabrication of Digital 3-axis Magnetometer for Magnetic Signal from Warship (함정 자기신호 측정용 3-축 디지털 자기센서 설계 및 제작에 관한 연구)

  • Kim, Eunae;Son, Derac
    • Journal of the Korean Magnetics Society
    • /
    • v.24 no.4
    • /
    • pp.123-127
    • /
    • 2014
  • We developed a digital 3-axis flux-gate magnetometer for magnetic field signal measurement from warship during demagnetizing and degaussing processes. For the magnetometer design, we considered following points; the distance between magnetic field measurement station and magnetometer located under sea is about several 100 m, the magnetometer is exposed to magnetic field of ${\pm}1mT$ during demagnetizing process, and magnetometer is located under the sea about 30 m depth. To overcome long distance problem, magnetometer could be operated on wide input supply voltage range of 16~36 V using DC/DC converter, and for the data communication between the magnetometer and measurement station a RS422 serial interface was employed. To improve perming effect due to the ${\pm}1mT$ during demagnetizing process, magnetometer could be compensated external magnetic field up to ${\pm}1mT$ but magnetic field measuring rang is only ${\pm}100{\mu}T$. The perming effect was about ${\pm}2nT$ under ${\pm}1mT$ external magnetic field. The magnetometer was tested water vessel with air pressure up to 6 bar for the sea water pressure problems. Linearity of the magnetometer was better than 0.01 % in the measuring range of ${\pm}0.1mT$ and noise level was $30pT/\sqrt{Hz}$ at 1 Hz.

The Obstacle Avoidance Algorithm of Mobile Robot using Line Histogram Intensity (Line Histogram Intensity를 이용한 이동로봇의 장애물 회피 알고리즘)

  • 류한성;최중경;구본민;박무열;방만식
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.6 no.8
    • /
    • pp.1365-1373
    • /
    • 2002
  • In this paper, we present two types of vision algorithm that mobile robot has CCD camera. for obstacle avoidance. This is simple algorithm that compare with grey level from input images. Also, The mobile robot depend on image processing and move command from PC host. we has been studied self controlled mobile robot system with CCD camera. This system consists of digital signal processor, step motor, RF module and CCD camera. we used wireless RF module for movable command transmitting between robot and host PC. This robot go straight until recognize obstacle from input image that preprocessed by edge detection, converting, thresholding. And it could avoid the obstacle when recognize obstacle by line histogram intensity. Host PC measurement wave from various line histogram each 20 pixel. This histogram is (x, y) value of pixel. For example, first line histogram intensity wave from (0, 0) to (0, 197) and last wave from (280, 0) to (2n, 197. So we find uniform wave region and nonuniform wave region. The period of uniform wave is obstacle region. we guess that algorithm is very useful about moving robot for obstacle avoidance.

A 30 GHz Band Low Noise for Satellite Communications Payload using MMIC Circuits (MMIC 회로를 이용한 위성중계기용 30GHz대 저잡음증폭기 모듈 개발)

  • 염인복;김정환
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.5
    • /
    • pp.796-805
    • /
    • 2000
  • A 30GHz band low noise amplifier module, which has linear gain of 30dB and noise figure of 2.6dB, for 30GHz satellite communication transponder was developed by use of MMIC and thin film MIC technologies. Two kinds of MMIC circuits were used for the low noise amplifier module, the first one is ultra low noise MMIC circuit and the other is wideband and high gain MMIC circuit. The pHEMT technology with 0.15$mu extrm{m}$ of gate length was applied for MMIC fabrication. Thin film microstrip lines on alumina substrate were used to interconnect two MMIC chips, and the thick film bias circuit board were developed to provide the stabilized DC bias. The input interface of the low noise amplifier module was designed with waveguide type to receive the signal from antenna directly, and the output port was adopted with K-type coaxial connector for interface with the frequency converter module behind the low noise amplifier module. Space qualified manufacturing processes were applied to manufacture and assemble the low noise amplifier module, and space qualification level of environment tests including thermal and vibration test were performed for it. The developed low noise amplifier was measured to show 30dB of minimum gain, $\pm$0.3dB of gain flatness, and 2.6dB of maximum noise figure over the desired operating frequency range from 30 to 31 GHz.

  • PDF

Design of Single Balanced Diode Mixer with Filter for Improving Band Flatness in Microwave Frequency Down Converter (마이크로파 주파수 하향 변환기에서의 대역 평탄도 개선을 위한 여파기 집적형 단일 평형 다이오드 혼합기 설계)

  • Ryu, Seung-Kab;Hwang, In-Ho;Han, Seok-Kyun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.1 s.116
    • /
    • pp.37-43
    • /
    • 2007
  • In this.paper, we introduce design and implementation results of the single balanced diode mixer for European point-to-point microwave radio in order to improve flatness performance. When a resonator such as RF filter is integrated with a mixer, impedance characteristic of 50 ohm is maintained only in RF band, not in LO band resulting deterioration of flatness performance because of LO power variation on the diode. In the paper, we suggest a design method of mixer integrated with image rejection filter and LO harmonic filter to have a better performance of flatness using embedding electrical length between filter and mixer's port. Frequency specification of fabricated mixer is $21.2{\sim}22.6\;GHz$ for RF, $19.32{\sim}20.72\;GHz$ for LO and 1.88 GHz+/-50 MHz for IF, respectively. Measured results show conversion loss of 8.5 dB, flatness of 2 dB, input PldB of 8 dBm, IIP3 of 15 dBm under LO power level of 10 dBm. Return losses of RF, LO and IF port are under -12 dB, -10 dB and -5 dB, respectively. Isolations of LO/RF and LO/IF are 20 dB and 50 dB, respectively.

3-Dimensional Numerical Analysis of Air Flow inside OWC Type WEC Equipped with Channel of Seawater Exchange and Wave Characteristics around Its Structure (in Case of Regular Waves) (해수소통구를 구비한 진동수주형 파력발전구조물 내에서 공기흐름과 구조물 주변에서 파랑특성에 관한 3차원수치해석(규칙파의 경우))

  • Lee, Kwang Ho;Lee, Jun Hyeong;Jeong, Ik Han;Kim, Do Sam
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.30 no.6
    • /
    • pp.242-252
    • /
    • 2018
  • It is well known that an Oscillating Water Column Wave Energy Converter (OWC-WEC) is one of the most efficient wave absorber equipment. This device transforms the vertical motion of water column in the air chamber into the air flow velocity and produces electricity from the driving force of turbine as represented by the Wells turbine. Therefore, in order to obtain high electric energy, it is necessary to amplify the water surface vibration by inducing resonance of the piston mode in the water surface fluctuation in the air chamber. In this study, a new type of OWC-WEC with a seawater channel is used, and the wave deformation by the structure, water surface fluctuation in the air chamber, air outflow velocity from the nozzle and seawater flow velocity in the seawater channel are evaluated by numerical analysis in detail. The numerical analysis model uses open CFD code OLAFLOW model based on multi-phase analysis technique of Navier-Stokes solver. To validate model, numerical results and existing experimental results are compared and discussed. It is revealed within the scope of this study that the air flow velocity at nozzle increases as the Ursell number becomes larger, and the air velocity that flows out from the inside of the air chamber is larger than the velocity of incoming air into the air chamber.

Analysis of Quantization Noise in Magnetic Resonance Imaging Systems (자기공명영상 시스템의 양자화잡음 분석)

  • Ahn C.B.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.8 no.1
    • /
    • pp.42-49
    • /
    • 2004
  • Purpose : The quantization noise in magnetic resonance imaging (MRI) systems is analyzed. The signal-to-quantization noise ratio (SQNR) in the reconstructed image is derived from the level of quantization in the signal in spatial frequency domain. Based on the derived formula, the SQNRs in various main magnetic fields with different receiver systems are evaluated. From the evaluation, the quantization noise could be a major noise source determining overall system signal-to-noise ratio (SNR) in high field MRI system. A few methods to reduce the quantization noise are suggested. Materials and methods : In Fourier imaging methods, spin density distribution is encoded by phase and frequency encoding gradients in such a way that it becomes a distribution in the spatial frequency domain. Thus the quantization noise in the spatial frequency domain is expressed in terms of the SQNR in the reconstructed image. The validity of the derived formula is confirmed by experiments and computer simulation. Results : Using the derived formula, the SQNRs in various main magnetic fields with various receiver systems are evaluated. Since the quantization noise is proportional to the signal amplitude, yet it cannot be reduced by simple signal averaging, it could be a serious problem in high field imaging. In many receiver systems employing analog-to-digital converters (ADC) of 16 bits/sample, the quantization noise could be a major noise source limiting overall system SNR, especially in a high field imaging. Conclusion : The field strength of MRI system keeps going higher for functional imaging and spectroscopy. In high field MRI system, signal amplitude becomes larger with more susceptibility effect and wider spectral separation. Since the quantization noise is proportional to the signal amplitude, if the conversion bits of the ADCs in the receiver system are not large enough, the increase of signal amplitude may not be fully utilized for the SNR enhancement due to the increase of the quantization noise. Evaluation of the SQNR for various systems using the formula shows that the quantization noise could be a major noise source limiting overall system SNR, especially in three dimensional imaging in a high field imaging. Oversampling and off-center sampling would be an alternative solution to reduce the quantization noise without replacement of the receiver system.

  • PDF