• Title/Summary/Keyword: 2nd-harmonic

Search Result 168, Processing Time 0.024 seconds

A Study on the 2nd Harmonic Blocking Scheme and Setting Value of a Current Differential Relay for 154 kV Transformers to Prevent Maloperation (154 kV 변압기 보호용 비율차동계전기 오동작 방지를 위한 2고조파 억제 방식의 적용방법 및 정정값에 관한 연구)

  • Son, Yong-Beom;Kang, Sang-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.1
    • /
    • pp.29-37
    • /
    • 2018
  • Inrush current and fault current in a transformer need to be distinguished from one another. In order to do this, KEPCO uses a 2nd harmonic restraint/block method. We use two setting values for 2nd harmonic restraint; 15% and 10%. We also apply per-phase blocking method among various harmonic restraint methods. If the transformer is located at the radial system, we adjust 10% in the 2nd harmonic restraint, but this method is not enough to prevent mal-operations of the current differential relay and let us spend more time to change setting value again as the power system changes. In this paper, a more reasonable setting value for a 2nd harmonic blocking scheme in KEPCO is proposed. To present a proposed method, the fault data of the current differential relays which have occurred since 2009 are analyzed. To evaluate the performance of the proposed method, the results of the RTDS test for the current differential relay of the transformer by KEPCO are analyzed.

Islanding Detection Method for Inverter-Based Distributed Generation through Injection of Second Order Harmonic Current

  • Lee, Yoon-Seok;Yang, Won-Mo;Han, Byung-Moon
    • Journal of Power Electronics
    • /
    • v.18 no.5
    • /
    • pp.1513-1522
    • /
    • 2018
  • This paper proposes a new islanding detection method for inverter-based distributed generators by continuously injecting a negligible amount of 2nd order harmonic current. The proposed method adopts a proportional resonant (PR) controller for the output current control of the inverter, and a PR filter to extract the 2nd order harmonic voltage at the point of common coupling (PCC). The islanding state can be detected by measuring the magnitude ratio of the 2nd order harmonic voltage to the fundamental voltage at the PCC by injecting a 2nd order harmonic current with a 0.8% magnitude. The proposed method provides accurate and fast detection under grid voltage unbalance and load unbalance. The operation of the proposed method has been verified through simulations and experiments with a 5kW hardware set-up, considering the islanding test circuit suggested in UL1741.

A 2nd Order Harmonic Compensation Method for Wind Power System Using a PR Controller

  • Jeong, Hae-Gwang;Lee, Jong-Hyun;Lee, Kyo-Beum
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.3
    • /
    • pp.507-515
    • /
    • 2013
  • This paper proposes a compensation method for the $2^{nd}$-order harmonic of single-phase grid-connected wind power generation systems. Theoretically, a single-phase grid-connected inverter system has no choice but to cause the $2^{nd}$-order harmonic to DC-link voltage. The reference active current is affected by the DC-link voltage. The output current from the reference active current is distorted by the $1^{st}$ and $3^{rd}$-order harmonic. The proposed method can compensate, conveniently, the reference active current with the $2^{nd}$-order harmonic. To reduce the $2^{nd}$-order ripple in the reference active current, proposed method takes a PR controller as a feed-forward compensator. PR controllers can implement selective harmonic compensation without excessive computational requirements; the use of these controllers simplifies the method. Both the simulation and experimental results agree well with the theoretical analysis.

Even Harmonic Analysis of Series Arc-fault Current Using BPF of GIC Application in Computer (GIC 적용 대역통과필터를 이용한 컴퓨터 부하의 직렬 아크고장 전류 우수고조파 분석)

  • Ko, Won-Sik;Moon, Won-Sik;Bang, Sun-Bae;Kim, Jae-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.10
    • /
    • pp.1554-1560
    • /
    • 2012
  • In this paper, the even harmonic current(2nd, 4th, 6th, 8th) of the arc fault current and normal current were measured in computer load and analyzed. The BPF with GIC was developed to detection of harmonic, the exact center frequency and a high degree of sharpness could be easily obtained. The total even harmonic distortion due to series arc fault in computer load was 31.2%, this value was increased 3.9 times better than the total even harmonic distortion of normal current. The results of analysis of arc fault current RMS variation rate and Peak variation rate per half-cycle, The RMS average variation rate are as follows ; the 2nd harmonic was 0.24, the 4th harmonic was 0.15, the 6th harmonic was 0.19, the 8th harmonic was 0.25, respectively. The Peak average variation rate are as follows ; the 2nd harmonic was 0.19, the 4th harmonic was 0.12, the 6th harmonic was 0.13, the 8th harmonic was 0.15, respectively. The results of this analysis utilize data to detect of series arc fault on wiring of computer load.

Analysis of Harmonic Wave Generation in Nonlinear Oblique Crack Surface (비선형 경사 균열면에서의 고조파 발생 특성 해석)

  • Kim, Noh-Yu;Yang, Seung-Yong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.4
    • /
    • pp.376-387
    • /
    • 2012
  • Based on the nonlinear spring model coupled with perturbation method, 2nd harmonic waves generated by oblique incident ultrasound on nonlinear crack interface were calculated and investigated. Reflected and transmitted waves from the interface were determined and analyzed at various angle of incidence for the cracks with different interfacial stiffness in order to estimate the 2nd harmonic generation of incident ultrasound. It was shown in computer simulation that the 2nd harmonic components changed much with the increase of incidence angle in both reflected and transmitted wave, but became very small when the incident angle approached toward 90 degree. It can be concluded that the 2nd harmonic component of reflected wave has a meaningful amplitude as much as the transmitted 2nd harmonic wave from partly closed crack.

Performance Improvement of Protective Relaying for Large Transformer by Using Voltage-Current Trend and Flux-Differential Current Slope Characteristic (전압-전류 추이와 자속-차전류 기울기 특성을 이용한 변압기 보호계전기법의 성능 개선)

  • Park, Chul-Won;Park, Jae-Sae;Jung, Yun-Man;Ha, Kyung-Jae;Shin, Myong-Chul
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.53 no.2
    • /
    • pp.43-50
    • /
    • 2004
  • Percentage differential characteristic relaying(PDR) has been recognized as the principal basis for power transformer protection. Second harmonic restraint PDR has been widely used for magnetizing inrush in practice. Nowadays, relaying signals can contain 2nd harmonic component to a large extent even in a normal state, and 2nd harmonic ratio indicates a tendency of relative reduction because of the advancement of material. Further, as the power system voltage becomes higher and more underground cables are used, larger 2nd harmonic component in the differential current under internal fault is observed. And then, conventional 2nd harmonic restraint PDR exposes some doubt in reliability. It is, therefore, necessary to develop a new algorithm for performance improvement of conventional protective relaying. This paper proposes an advanced protective relaying algorithm by using voltage-current trend and flux-differential current slope characteristic. To evaluate the performance of the proposed algorithm, we have made comparative studies of PDR, fuzzy relaying and DWT relaying. The paper is constructed power system model including power transformer, utilizing the WatATP, and data collection is made through simulation of various internal faults and inrush. As the results of test, the new proposed algorithm was proven to be faster and more reliable.

A Study on Higher Harmonic Conversion of High Power Nd:Glass Laser (대출력 Nd:글라스 레이저의 고조파 변환에 관한 연구)

  • Gang, Hyeong-Bu;Jang, Yong-Mu
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.397-398
    • /
    • 1988
  • We report on the simulation results of 1)the second harmonic conversion with $1.053{\mu}m$ Nd:glass laser using monolithic KDP crystal and 2)the efficient conversion from $1.053{\mu}m$ to $0.35{\mu}m$ by the polarization-mismatch 3rd harmonic conversion in two Type-II crystals.

  • PDF

Q-Switched Nd YAG's SHG conversion techniques for a skin diseased treatment (피부질환 치료를 위한 Q-Switched Nd:YAG의 SHG 변환기술)

  • Kim, Whi-Young
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.6
    • /
    • pp.1141-1149
    • /
    • 2009
  • Pulse style Nd: YAG Laser is suitable in skin remaking treatment, in compliance with the ramp continuous oscillation until of course normal takeoff, the Q-switch and mode motive takeoff the takeoff form which is various is possible and it is coming to be widely used in microsurgery and skin remaking promotion. According to therapeutic objective very it is important to control a energy density. Control of energy density the method which controls the pulse repetition rate of Laser output is mainly used. From the research which it sees pulse style Nd: It will be able to control the pulse repetition rate of YAG, the 2nd harmonic occurrence Laser (second harmonic generation: SHG) with the energy part of the light-wave which is a footnote wave number will hold and nonlinear decision it propagates and is converted by energy of the light-wave which is a footnote wave number the actual condition which and it applies the second harmonic occurrence in compliance with a secondary nonlinearity it leads and until skin deep part therapeutic possibility is the thing it will be able to observe simply.

Second Harmonic Conversion of Nd:YAG Laser using $KH_2PO_4(KDP)$ Crystal ($KH_2PO_4(KDP)$ 결정을 이용한 Nd:YAG 레이저의 제3고조파 변환)

  • Chang, Yong-Moo;Kim, Byung-Tai;Kang, Hyung-Boo
    • Proceedings of the KIEE Conference
    • /
    • 1989.07a
    • /
    • pp.633-636
    • /
    • 1989
  • The simulation results of the third harmonic conversion with 1.064 um Nd :YAG laser using polarization mismatch method are reported. The third harmonic conversion efficiency was over 65% for the Gaussian incident pulse of $300{\sim}400MW/cm^2$ peak intensity, and over 80% for $3{\sim}4GW/cm^2$ peak intensity pulse. The dependence of the third harmonic conversion efficiency' on the variation of incident polarization angle ${\theta}_p$ and angular discrepancy ${\Delta}{\theta}$ of phase matched angle ${\theta}_m$ is discussed.

  • PDF

Second harmonic generation of YCOB($YCa_4O(BO_3)_3$) (YCOB($YCa_4O(BO_3)_3$)의 제2조화파 발생)

  • 장원권
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.4
    • /
    • pp.301-305
    • /
    • 1999
  • The phase matching conditions of the new optical crystal grown by Czochralski pulling method, YCOB($YCa_4O(BO_3)_3$) with wavelength were suggested, and the second harmonic generation efficiency for the fundamental of Nd:YAG laser of 1064 nm was investigated. The variation of nonlinearity with rare earth ion doping was also investigated by measuring the second harmonic generation efficiencies of $Yb^{3+}$ + $Nd^{3+}$and ion doped YCOBs.

  • PDF