• 제목/요약/키워드: 2D-PIV & 3D-PIV Measurement

검색결과 28건 처리시간 0.029초

Stereoscopic PTV 기법의 개발과 성능비교 연구 (Development of Stereoscopic PTV Technique and Performance Tests)

  • 이상준;윤전환
    • 대한기계학회논문집B
    • /
    • 제30권3호
    • /
    • pp.215-221
    • /
    • 2006
  • A stereoscopic particle tracking velocimetry (SPTV) technique based on the 2-frame hybrid particle tracking velocimetry (PTV) method was developed. The expansion of 2D PTV to SPTV is facilitated by the fact that the PTV method tracks individual particle centroids. To evaluate the performance and measurement accuracy of the present SPTV technique, it was applied to flow images of rigid body translation and synthetic standard images of jet shear flow and impinging jet flow. The data processing routine and measurement uncertainty of the SPTV technique are compared with those of conventional stereoscopic particle image velecimet.y (SPBV). In addition, the centroid translation effect of 2D particle image velocimetry (PIV) is defined and its effect on SPIV measurements is discussed. Compared to the SPIV method, the SPTV technique has inherited merits of concise and precise velocity evaluation procedures and provides better spatial resolution and measurement accuracy.

정방형 발열체를 갖는 수직채널 내부의 공기유동 관한 PIV계측 (PIV Measurement of Airflow in a Vertical Channel With Square Heat Source)

  • 배석태;김동균;김시범;조대환;이영호
    • 태양에너지
    • /
    • 제17권3호
    • /
    • pp.35-41
    • /
    • 1997
  • 정방형 발열체를 갖는 수직채널내부의 공기유동을 고찰하고자 레이저를 광원으로하는 가시화 실험을 행하였다. 영상처리시스템은 퍼스널컴퓨터의 내부에 장착할 수 있는 범용의 이미지보오드로 구성하였고 광원으로서는 아르곤-이온레이저와 원통형렌즈를 이용하여 시이트라이트를 만들어 이를 대상 유동장에 조사하고 유동장의 영상을 기록하였다. 전유동장의 순시속도벡터는 2차원 PIV시스템에 의하여 구하였고 채택된 동일입자추적기법은 계조치상호상관법이다. 발열체의 발열량은 5W로 균일하며 유입유속은 0.3m/sec으로 일정하게 하였다. 가시화를 통한 PIV계측 결과는 운동에너지와 난류운동에너지의 분포 등에서 유동패턴을 잘 나타내었다.

  • PDF

Development of 3-D Stereo PIV and Its Application to a Delta Wing

  • Kim, Beom-Seok;Lee, Hyun;Choi, Jang-Woon;Kadooka, Yoshimasa;Tago, Yoshio;Lee, Young-Ho
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.658-663
    • /
    • 2003
  • A process of 3-D stereo particle image velocimetry(PIV)was developed for the measurement of an illuminated sliced section field of 3-D complex flows. The present method includes modeling of camera by a calibrator based on the homogeneous coordinate system, transformation of the oblique-angled image to the right-angled image, identification of 2-D velocity vectors by 2-D cross-correlation equation, stereo matching of 2-D velocity vectors of two cameras, accurate calculation of 3-D velocity vectors by homogeneous coordinate system, removal of error vectors by a statistical method followed by a continuity equation criteria, and finally 3-D display as the post processing. An experimental system was also used for the application of the proposed method. Two high speed digital CCD cameras and an Argon-Ion Laser for the illumination were adopted to clarify the time-dependent characteristics of the leading edge extension(LEX) in a highly swept shape applied to a delta wing found in modern air-fighters.

  • PDF

Stereo-PIV/LIF의 속도장과 농도장 동시측정 기법을 이용한 러쉬톤 교반기내 난류특성에 관한 연구 (A Study on the Turbulent Characteristics of Rushton Turbine Mixer by Simultaneous Measurement of Velocity and Concentration field with Stereo-PIV/PLIF Technique)

  • 민영욱;김윤기;김경천
    • 대한기계학회논문집B
    • /
    • 제28권3호
    • /
    • pp.365-370
    • /
    • 2004
  • Simultaneous measurement with PLIF(Planar Laser-Induced Fluorescence) and Stereo-PIV(Stereo Particle Image Velocimetry) was performed to investigate the structural characteristics of flow field in Rushton Turbine Mixer. Instantaneous 3D velocity fields are measured by two 2K${\times}$2K CCD cameras focused on an object plane with the angular displacement methods while the concentration fields are obtained through the measurement of the fluorescence intensity of Rhodamine B tracer excited by the second pulse of Nd:Yag laser light. Image distortion due to the camera view-angle is compensated by a mapping function. Finally, the spatial structures of turbulent flow around Rushton turbine were identified by the calculation of synchronized data of the velocity field and concentration field.

슬라이드 밸브 급폐쇄에 따른 디스크 주위 비정상유동의 PIV계측에 관한 연구 (A Study on PIV Measurement of Unsteady Flow around Disk caused by Slide Type Valve Quick Closing)

  • 이철재;조대환
    • 해양환경안전학회지
    • /
    • 제15권3호
    • /
    • pp.251-256
    • /
    • 2009
  • 이 연구에서는 전 유동장의 순간속도를 계측 할 수 있는 PIV계측기법을 슬라이딩 밸브의 폐쇄 직후에 적용하고 짧은 시간에 발생하는 디스크 주위의 비정상 속도를 계측하여 유동특성을 실험적으로 고찰하였다. 순간유동장을 분석한 결과를 기존의 압력변동을 측정한 연구 결과에 비교 검토한 결과 슬라이드 밸브 급폐쇄에 따른 속도변동이 크게 나타나는 시간구간은 0.1초 이내이고 주기는 0.12초로 추정되었다. 또한 원관 내부의 디스크 주위유동은 상부부터 폐쇄되면서 유로가 좁아져 순간적으로 빠르게 하류로 진행하였으며 폐쇄직후에 역류하는 속도의 크기는 4/120초까지 감소하다가 다시 증가하는 경향을 보였다. 그리고 완전 폐쇄 후 상류 측으로 역류하는 흐름의 영향으로 y/D=0.2 하부 영역에 역류하는 속도성분이 나타났으며, y/D=0.7, x/D=-0.3의 근방에서 0.2D 크기의 회전와류가 관찰되었다.

  • PDF

구동류를 갖는 계단 캐비티의 PIV계측 (PIV measurement of step cavity with driven flow)

  • 조대환;김진구;이영호
    • 한국해양공학회지
    • /
    • 제12권1호
    • /
    • pp.113-119
    • /
    • 1998
  • An experimental study was carried out in a three-dimensional cubic cavity driven by 2-dimensional plane Poiseuille flow for three kinds of Reynolds number, $10^4$, 3 $\times$ $10^4$ and 5 $\times$ $10^4$ based on the cavity width and cavity inlet mean flow velcoity. Instant simultaneous velocity vectors at whole field were measured by 2-D PIV system. Laser based illumination and two-frame grey-level cross correlation algorithm are adopted. Severe unsteady flow fluctuation within the cavity are remarkable at above Re = 3 $\times$ $10^4$ Reynolds numbers and sheared mixing layer phenomena are also found at the region where inlet driving Poiseuille flow is collided with the clock-wise rotating main primary vortex at upper center area. Instant velocity profiles reveal that deformed forced vortex formation is observed throughout the separate two areas.

  • PDF

Stereo-PIV/PLIF의 속도장과 농도장 동시측정 기법을 이용한 러쉬톤 교반기내 난류특성에 관한 연구 (A Study on the Turbulent Characteristics of Rushton Turbine Mixer by Simultaneous Measurement of Velocity and Concentration Field with Stereo-PIV/PLIF Technique)

  • 민영욱;김윤기;김경천
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.694-699
    • /
    • 2003
  • Simultaneous measurement with PLIF(Planar Laser-Induced Fluorescence) and Stereo-PIV(Stereoscopic Particle Image Velocimetry) was performed to investigate the structural characteristics of flow field in Rushton Turbine Mixer. Instantaneous 3D velocity fields are measured by two 2K ${\times}$ 2K CCD cameras focused on an object plane with the angular displacement methods while the concentration fields are obtained through the measurement of the fluorescence intensity of Rhodamine B tracer excited by the second pulse of Nd:Yag laser light. Image distortion due to the camera view-angle is compensated by a mapping function. Finally, the spatial structures of turbulent mixing around Rushton turbine were identified by the calculation of cross-correlation fields between the velocity and concentration field.

  • PDF

PIV 기법을 이용한 모형철도터널 직관덕트에서 유동 분포 계측 및 수치해석 결과와의 비교분석 (MEASUREMENT OF FLOW DISTRIBUTION IN A STRAIGHT DUCT OF RAILWAY TUNNEL MOCK-UP USING PIV AND COMPARISON WITH NUMERICAL SIMULATION)

  • 장용준;정우성;박일순
    • 한국전산유체공학회지
    • /
    • 제15권3호
    • /
    • pp.39-45
    • /
    • 2010
  • The turbulent flows in a tunnel mock-up($10L{\times}0.5W{\times}0.25H$ m3 : scale reduction 1/20) with rectangular cross section were investigated. The instantaneous velocity fields of Re = 49,029, 89,571 were measured by the 2-D PIV system which is consisted of double pulsed Nd:Yag laser and the tracer particles in the straight-duct mock-up where the flows were fully developed. The mean velocity profiles were taken from the ensemble averages of 1,000 instantaneous velocity fields. Simultaneously, numerical simulations(RANS) were performed to compare with experimental data using STREAM code. Non-linear eddy viscosity model (NLEVM : Abe-Jang-Leschziner Eddy Viscosity Model) was employed to resolve the turbulent flows in the duct. The calculated mean velocity profiles were well compared with PIV results. In the log-law profiles, the experimental data were in good agreement with numerical simulations all the way to the wake region except the viscous sub-layer (near wall region).

Towed underwater PIV measurement for free-surface effects on turbulent wake of a surface-piercing body

  • Seol, Dong Myung;Seo, Jeong Hwa;Rhee, Shin Hyung
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제5권3호
    • /
    • pp.404-413
    • /
    • 2013
  • In the present study, a towed underwater particle image velocimetry (PIV) system was validated in uniform flow and used to investigate the free-surface effects on the turbulent wake of a simple surface-piercing body. The selected test model was a cylindrical geometry formed by extruding the Wigley hull's waterplane shape in the vertical direction. Due to the constraints of the two-dimensional (2D) PIV system used for the present study, the velocity field measurements were done separately for the vertical and horizontal planes. Using the measured data at several different locations, it was possible to identify the free-surface effects on the turbulent wake in terms of the mean velocity components and turbulence quantities. In order to provide an accuracy level of the data, uncertainty assessment was done following the International Towing Tank Conference standard procedure.

PIV 계측에 의한 산업용 송풍기 익의 유동특성 (Flow Characteristics for Blade of Industiral Axial Blower by PIV Measurement Method)

  • 김진구;윤석범
    • 태양에너지
    • /
    • 제19권3호
    • /
    • pp.115-123
    • /
    • 1999
  • An experimental study was carried out to investigate the flow characteristics of a stationary blade for six kinds of measuring angles of attack, $0^{\circ},\;10^{\circ},\;20^{\circ}\;and\;30^{\circ}$ at Reynolds number of $5.8{\times}10^4$. Instant simultaneous velocity vectors around blade were measured by 2-D PIV system where laser-based illumination and two-frame grey-level cross correlation algorithm were adopted. Velocity profiles show uniform approaching flow from the straightening equipment, and experimental results reveal that separation phenomena occur and the separation point moves upstream with increasing angle of attack.

  • PDF