• Title/Summary/Keyword: 2D scanner

Search Result 403, Processing Time 0.021 seconds

Marginal and internal fit of interim crowns fabricated with 3D printing and milling method (3D 프린팅 및 밀링 방법으로 제작된 임시 보철물 적합도 비교 분석)

  • Son, Young-Tak;Son, KeunBaDa;Lee, Kyu-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.4
    • /
    • pp.254-261
    • /
    • 2020
  • Purpose: The purpose of this study was to assess the marginal and internal fit of interim crowns fabricated by two different manufacturing method (subtractive manufacturing technology and additive manufacturing technology). Materials and Methods: Forty study models were fabricated with plasters by making an impression of a master model of the maxillary right first molar for ceramic crown. On each study model, interim crowns (n = 40) were fabricated using three types of 3D printers (Meg-printer 2; Megagen, Zenith U; Dentis, and Zenith D; Dentis) and one type milling machine (imes-icore 450i; imes-icore GmbH). The internal of the interim crowns were filled with silicon and fitted to the study model. Internal scan data was obtained using an intraoral scanner. The fit of interim crowns were evaluated in the margin, absolute margin, axial, cusp, and occlusal area by using the superimposition of 3D scan data (Geomagic control X; 3D Systems). The Kruskal-wallis test, Mann-Whitney U test and Bonferroni correction method were used to compare the results among groups (α = 0.05). Results: There was no significant difference in the absolute marginal discrepancy of the temporary crown manufactured by three 3D printers and one milling machine (P = 0.812). There was a significant difference between the milling machine and the 3D printer in the axial and occlusal area (P < 0.001). The temporary crown with the milling machine showed smaller axial gap and higher occlusal gap than 3D printer. Conclusion: Since the marginal fit of the temporary crown produced by three types of 3D printers were all with in clinically acceptable range (< 120 ㎛), it can be sufficiently used for the fabrication of the temporary crown.

Fit Tests for Second-class Half Masks (2급 방진마스크 밀착도 평가)

  • Cho, Kee Hong;Kim, Hyun Soo;Choi, Ah Rum;Chun, Ji Young;Kang, Tae Won;Kim, Min Su;Park, Kyeong Hak;Kim, Ze One
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.32 no.2
    • /
    • pp.146-152
    • /
    • 2022
  • Objectives: The purpose of this study is to confirm whether there is a factor to affect the evaluation of fit test of a 2nd class half masks using a OPC test method. Methods: Total 34 adults including Males and Females were tested using OPC-based fit testing equipment while wearing a 2nd class half filtered mask. Results: 1. The result of measuring face dimensions using different tools such as a 3D scanner and digital calipers revealed that the variation of lip width was not statistically significant because there was only a difference of about 4 mm. However, it showed that a difference in face length was statistically significant enough with 10 mm(p<0.000). 2. The fit factor for each exercise stage according to gender was the highest at 124.54(p<0.001) in Step 3, and the fit factor was the lowest at 73.75 in Step 1. 3. In the evaluation of the degree of fit factor according to gender, female passed 67.44%, which was higher than the value in male(p<0.038). 4. The acceptance rate of the group having a face length of shorter than 110 mm was 91.67%. On the other hand, the acceptance rate of the group with a face length of longer than 110 mm was 47.27%(p<0.000). 5. The fit test was possible because the fit factor with 2nd class half masks corresponding to FFP1(Filtering Face Piece 1) was passed 55% or more. Conclusions: The test results showed that using a 2nd class half filtered mask, it is important to wear a properly designed mask so that face size does not affect the fit factor.

Reconstruction of Stereo MR Angiography Optimized to View Position and Distance using MIP (최대강도투사를 이용한 관찰 위치와 거리에 최적화 된 입체 자기공명 뇌 혈관영상 재구성)

  • Shin, Seok-Hyun;Hwang, Do-Sik
    • Investigative Magnetic Resonance Imaging
    • /
    • v.16 no.1
    • /
    • pp.67-75
    • /
    • 2012
  • Purpose : We studied enhanced method to view the vessels in the brain using Magnetic Resonance Angiography (MRA). Noticing that Maximum Intensity Projection (MIP) image is often used to evaluate the arteries of the neck and brain, we propose a new method for view brain vessels to stereo image in 3D space with more superior and more correct compared with conventional method. Materials and Methods: We use 3T Siemens Tim Trio MRI scanner with 4 channel head coil and get a 3D MRA brain data by fixing volunteers head and radiating Phase Contrast pulse sequence. MRA brain data is 3D rotated according to the view angle of each eyes. Optimal view angle (projection angle) is determined by the distance between eye and center of the data. Newly acquired MRA data are projected along with the projection line and display only the highest values. Each left and right view MIP image is integrated through anaglyph imaging method and optimal stereoscopic MIP image is acquired. Results: Result image shows that proposed method let enable to view MIP image at any direction of MRA data that is impossible to the conventional method. Moreover, considering disparity and distance from viewer to center of MRA data at spherical coordinates, we can get more realistic stereo image. In conclusion, we can get optimal stereoscopic images according to the position that viewers want to see and distance between viewer and MRA data. Conclusion: Proposed method overcome problems of conventional method that shows only specific projected image (z-axis projection) and give optimal depth information by converting mono MIP image to stereoscopic image considering viewers position. And can display any view of MRA data at spherical coordinates. If the optimization algorithm and parallel processing is applied, it may give useful medical information for diagnosis and treatment planning in real-time.

Effect of mixing method and storage time on dimensional stability of alginate impressions materials (혼합 방법과 보관 시간이 알지네이트 인상재의 체적 안정성에 미치는 효과)

  • Bang, Hyun-Ji;Shim, Hyun-Ah;Cho, Young-Eun;Park, Eun-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.2
    • /
    • pp.86-94
    • /
    • 2020
  • Purpose: The purpose of this study is to compare the volume stability depending on the mixing methods and storage time for the conventional alginate and extended-pour alginate. Materials and methods: An arch-shaped metal model was fabricated, and one conventional alginate and two extended-pour alginates were used to take impressions using different mixing methods (hand and automatic). 120 impressions were taken (40 per each alginate) and stone models were made in accordance with the different storage times (immediate, 2 days, 5 days, and 6 days). The models were scanned with a 3D table scanner and dimensional change was measured by superimposing the scan data. Using SAS 9.4 (SAS Institute Inc., Cary, NC, USA), the general linear model and Tukey's post hoc test was conducted for statistical analysis (P<.001). Results: There was no statistically significant difference in the dimensional accuracy between two mixing methods, and the volume change was minimum when the stone was poured immediately in all groups. Dimensional accuracy showed a statistically significant difference between groups after 2 days of storage, and extended-pour alginate showed higher accuracy after 5 days of storage comparing to conventional one. Large amounts of volume change were showed at 2 - 5 days for conventional alginate and at 5 - 6 days for extended pour alginate. Conclusion: The mixing method of alginate does not affect volume stability. Although extended-pour alginate has better volume stability than conventional alginate for a long time, it is recommended to pour stone as soon as possible.

Accuracy Analysis of Medium Format CCD Camera RCD105 (중형카메라 RCD105 정확도 분석)

  • Kim, Tae-Hoon;Won, Jae-Ho;Kim, Chung-Pyeong;So, Jae-Kyeong;Yun, Hee-Cheon
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.28 no.4
    • /
    • pp.449-454
    • /
    • 2010
  • Lately, airborne digital camera and airborne laser scanner in field of airborne surveying are used to build geography information such as digital ortho photo map and DEM(Digital Elevation Model). In this study, 3D position accuracy is compared medium format CCD camera RCD105 with airborne digital camera DMC. For this, test area was decided for aerial photograph. And using 1/1,000 scale digital map, ground control points were selected for aerial triangulation and check points were selected for horizontal/vertical accuracy analysis using softcopy stereoplotter. Accuracy of RCD105 and DMC was estimated by result of aerial triangulation and result of check points measurement of using softcopy stereoplotter. In result of aerial triangulation, RMSE(Root Mean Square Error) X, Y, Z of RCD105 is 2.1, 2.2, 1.3 times larger than DMC. In result of check point measurement using softcopy stereoplotter, horizontal/ vertical RMSE of RCD105 is 2.5, 4.3 times larger than DMC. Even though accuracy of RCD105 is lower than DMC, it is maybe possible to make digital map and ortho photo using RCD105.

The Study of in Vivo Visual Pathway Tracing using Magnetic Magnanese Tracer (자성 망간 추적자를 이용한 in Vivo 시신경경로 추적에 관한 연구)

  • Bae, Sung-Jin;Chang, Yong-Min
    • Progress in Medical Physics
    • /
    • v.18 no.1
    • /
    • pp.42-47
    • /
    • 2007
  • Purpose: To evaluate the tracing of optic nerve tract using manganese enhanced magnetic resonance Imaging. Materials and Methods: After injecting $30{\mu}l$ of $MnCl_2(1mol)$ (1 mol) Into the retina of female New Zealand white rabbit, the contrast enhancements at major anatomical structures of optic nerve tract were evaluated by high resolution T1-weighted Images 12 hours, 24 hours, and 48 hours after $MnCl_2(1mol)$ Injection using 3D FSPGR (Fast Speiled Gradient Recalled echo) pulse sequence at 1.5T clinical MR scanner with high performance gradient system. Also, for quantitative evaluation, the signal-to-noise ratios of circular ROI on anatomical locations were measured. Results: The major structures on the optic nerve tract were enhanced after injecting $MnCl_2(1mol)$. The structures, which showed enhancement, were right optic nerve, optic chiasm, left optic tract, left lateral geniculate nucleus, left superior colliculus. The structures on the contralateral optic pathway to the right retina were enhanced whereas the structures on the ipsilateral pathway did not show enhancement. Conclusion: The Mn transport through axonal pathway of optic nerve sys)em was non- invasively observed after injecting injecting $MnCl_2$ at the retina, which is the end terminal of optic nerve system. This Mn transport seems to occur by voltage gated calcium $(Ca^{2+})$ channel and In case of direct Injection Into the retina, the fast transpori pathway of voltage gated calcium channel seems to be responsible for Mn transport.

  • PDF

Three-dimensional finite element analysis of unilateral mastication in malocclusion cases using cone-beam computed tomography and a motion capture system

  • Yang, Hun-Mu;Cha, Jung-Yul;Hong, Ki-Seok;Park, Jong-Tae
    • Journal of Periodontal and Implant Science
    • /
    • v.46 no.2
    • /
    • pp.96-106
    • /
    • 2016
  • Purpose: Stress distribution and mandible distortion during lateral movements are known to be closely linked to bruxism, dental implant placement, and temporomandibular joint disorder. The present study was performed to determine stress distribution and distortion patterns of the mandible during lateral movements in Class I, II, and III relationships. Methods: Five Korean volunteers (one normal, two Class II, and two Class III occlusion cases) were selected. Finite element (FE) modeling was performed using information from cone-beam computed tomographic (CBCT) scans of the subjects' skulls, scanned images of dental casts, and incisor movement captured by an optical motion-capture system. Results: In the Class I and II cases, maximum stress load occurred at the condyle of the balancing side, but, in the Class III cases, the maximum stress was loaded on the condyle of the working side. Maximum distortion was observed on the menton at the midline in every case, regardless of loading force. The distortion was greatest in Class III cases and smallest in Class II cases. Conclusions: The stress distribution along and accompanying distortion of a mandible seems to be affected by the anteroposterior position of the mandible. Additionally, 3-D modeling of the craniofacial skeleton using CBCT and an optical laser scanner and reproduction of mandibular movement by way of the optical motion-capture technique used in this study are reliable techniques for investigating the masticatory system.

A Study on the Pattern of Custom-Made Girdles for Obese Women (비만여성의 일대일 맞춤거들 패턴에 대한 연구)

  • Nam, Yun-Ja;Lee, Jun-Ok
    • Journal of the Ergonomics Society of Korea
    • /
    • v.21 no.2
    • /
    • pp.71-86
    • /
    • 2002
  • This study's purpose is to gain basic data for the factory automation of manufacturing custom-made girdles. For this study , obese women in their 30s and 40s was experimented through direct measuring and by the 3D scanner, by means of which the proportions of the subject's body was measured. Based upon the results of this experiment, individually designed girdles were made. In order to gain the basic data for the factory automation of manufacturing custom-made girdles, the patterns and the clothing pressure and the feeling of wearing such girdles were analyzed. This study can be summarized as follows: The material properties and the designs of existing functional girdles in the market were studied thoroughly, and the subject were required to wear those existing girdles. On the basis of this result, the experimental girdles were designed and produced which could serve well the subject's intension. The experimental girdles were of the basic long-type in order to apply to all sorts of girdles, and they were produced according to the style and pattern of the existing grading system. The second experiment was conducted by applying the subject's body measurements. Due to the elasticity of the material, in girdles the smaller measurements were to be used in this second experiment were: 80% of waist size, 84% of the hip and 85% of the thigh. To determine the length of the girdles, the same measurements were applied. The test results of the feeling of wearing the experimental girdles showed that the second, custom-made experimental girdles were better. According to the test results of the clothing pressure, the second experimental girdles(custom-made girdles) marked the higher pressure than the first on every part of the body, especially on the hips and thighs. Thus, it can be said that the second experimental girdles are better than the first in lifting up the hips. It is expected that the design methods developed in this study can be utilized as basic resources for the factory automation system of manufacturing custom-made girdles.

The Qualitative Analysis of Single Shot Fast Spin Echo (SSFSE) and Maximum Intensity Projection (MIP) on Magnetic Resonance Cholangiopancreatography

  • Park, Cheol-Soo;Cho, Jae-Hwan;Lee, Hae-Kag;Dong, Kyung-Rae;Chung, Woon-Kwan;Seok, Jong-Min;Han, Man-Seok;Lee, Sun-Yeob;Goo, Eun-Hoe;Kim, Eng-Chan
    • Journal of Magnetics
    • /
    • v.17 no.2
    • /
    • pp.138-144
    • /
    • 2012
  • 3-dimensional magnetic resonance cholangiopancreatography (MRCP) images reconstructed using the maximum intensity projection technique were analyzed qualitatively in patients diagnosed with pancreatobiliary diseases to determine their diagnostic utility. Single shot fast spin echo (SSFSE), fast spin echo (FSE) and 3-dimensional reconstructive images were acquired from 20 patients diagnosed histologically with pancreatobiliary diseases using a 3.0T MR scanner. According to qualitative analysis, the fast spin echo images and 3-dimensional reconstructed images of the hepatic duct, gall bladder and common bile duct had a higher signal to noise ratio (SNR) than the single shot fast spin echo images. Fast spin echo images and 3-dimensional reconstructed images did not show any differences. The contrast to noise ratio of the hepatic duct, gallbladder and common bile duct on the fast spin echo images and 3-dimensional reconstructed images was higher than that of the single shot fast spin echo images. The fast spin echo images and 3-dimensional reconstructed images showed similar quality.

Marginal fit evaluation of 3 unit fixed dental prostheses fabricated by rapid prototyping method (쾌속 조형 기술을 이용하여 제작된 3본 고정성 보철물의 적합도 평가)

  • Kim, Ki-Baek;Kim, Jae-Hong;Kim, Woong-Chul;Kim, Hae-Young;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.34 no.2
    • /
    • pp.105-111
    • /
    • 2012
  • Purpose: The purpose this study was to evaluate the marginal fitness of metal copings fabricated using rapid prototyping method and to compare the fitness with copings by conventional method. Then clinical availability of fixed dental prostheses (FDPs) fabricated using rapid prototyping method shall be confirmed based on marginal fitness. Methods: Ten same cases of3 unit FDPs epoxy models (abutment teeth 14 and 16) were manufactured. Each of ten epoxy models were scanned by 3shape D-700 scanner to be designed by experienced technician, and photopolymer 3 unit FDPs were fabricated using rapid prototyping methodand fabricated using Lost wax technique (LW) with same models. Marginal fitness of 3 unit FDPs were measured by silicone replica technique. T-test of independent sample for statistical analysis was executed with SPSS 12.0K for Windows. (${\alpha}$=.05) Results: Significantly higher mean (SD) marginal fitness (P<.000) were observed in the RP group $(95.9(18.0){\mu}m$ compared to the conventionally LW group $(80.1(13.8){\mu}m$. Conclusion: Marginal fitness of LW group showed excellent rather than RP group. However marginal fitness of 3 unit FDPs fabricated by RP method did not get out of clinical allowance value range significantly to allow clinical application.