• 제목/요약/키워드: 2D scanner

검색결과 403건 처리시간 0.026초

A Study on the Sundials of the Kang Family of Jinju

  • Kim, Sang-Hyuk;Lee, Ki-Won;Lee, Yong-Sam
    • Journal of Astronomy and Space Sciences
    • /
    • 제27권2호
    • /
    • pp.161-172
    • /
    • 2010
  • In this paper, we investigate the sundials made by the Kang Family of Jinju in the later period of the Joseon dynasty in terms of their characteristics, functions and the manufacturing technique. One of the characteristics of these sundials is that the value of polar height (i.e., the latitude of Seoul), the name of manufacturer, 24 seasonal subdivisions and so forth are written on the surface. In particular, polar height is expressed as '$37^{\circ}$ 39' 15"' in all 12 sundials examined in this study. To investigate the manufacturing technology in terms of astronomy, we analyze the positions of gnomon and of the lines corresponding to 24 seasonal subdivisions (season lines) and to each hour (hour lines). To verify the accuracy of the positions, we use a planar projection method. That is, we obtain 2D images of the sundials using a camera or scanner, and compare these with astronomical calculations for the positions of gnomon and season/hour lines. We believe that this method will be very useful for the study of sundials preserved elsewhere.

3차원 대면적 연속 마이크로 레이저 패터닝을 위한 연구 (Study of 3 dimensional wide area continuous laser micro patterning)

  • 김경한;손현기;이제훈
    • 한국레이저가공학회지
    • /
    • 제18권4호
    • /
    • pp.1-5
    • /
    • 2015
  • For continuous laser micro patterning on three-dimensional free form surface, innovative laser system is developed. The two axis galvanometer is combined with the dynamic focusing unit to increase optical distance. Also, it is synchronized with the 3 axis mechanical system. To determine laser machining sequence, laser CAM system is developed. It can make possible of 3D surface micro patterning under $25{\mu}m$ pattern width. The uniformity of pattern width is about 2.8% and it is validated that focal plane is well conserved by the dynamic focusing unit. Velocity and positional information of 1 axis is stage is fed to the scanner control board by the encoder signal and it makes possible real time synchronization. With this system, possible patterning volume is enlarged from $40{\times}40mm^2$ to $40{\times}120{\times}30mm^3$.

드론 및 레이저스캐너를 활용한 근대 건축물 문화재 빌딩정보 모델 역설계 구축에 관한 연구 (Using Drone and Laser Scanners for As-built Building Information Model Creation of a Cultural Heritage Building)

  • 정래규;구본상;유영수
    • 한국BIM학회 논문집
    • /
    • 제9권2호
    • /
    • pp.11-20
    • /
    • 2019
  • The use of drones and laser scanners have the potential to drastically reduce the time and costs of conventional techniques employed for field survey of cultural heritage buildings. Moreover, point cloud data can be utilized to create an as-built Building Information Model (BIM), providing a repository for consistent operations information. However, BIM creation is not a requisite for heritage buildings, and their technological possibilities and barriers have not been documented. This research explored the processes required to convert a heritage university building to a BIM model, using existing off-the-shelf software applications. Point cloud data was gathered from drones for the exterior, while a laser scanner was employed for the interior of the building. The point clouds were preprocessed and used as references for the geometry of the building elements, including walls, slabs, windows, doors, and staircases. The BIM model was subsequently created for the individual elements using existing and custom libraries. The model was used to extract 2D CAD drawings that met the requirements of Korea's heritage preservation specifications. The experiment showed that technical improvements were needed to overcome issues of occlusion, modeling errors due to modeler's subjective judgements and point cloud data cleaning and filtering techniques.

Comparison of different digital shade selection methodologies in terms of accuracy

  • Nursen Sahin;Cagri Ural
    • The Journal of Advanced Prosthodontics
    • /
    • 제16권1호
    • /
    • pp.38-47
    • /
    • 2024
  • PURPOSE. This study aims to evaluate the accuracy of different shade selection techniques and determine the matching success of crown restorations fabricated using digital shade selection techniques. MATERIALS AND METHODS. Teeth numbers 11 and 21 were prepared on a typodont model. For the #11 tooth, six different crowns were fabricated with randomly selected colors and set as the target crowns. The following four test groups were established: Group C, where the visual shade selection was performed using the Vita 3D Master Shade Guide and the group served as the control; Group Ph, where the shade selection was performed under the guidance of dental photography; Group S, where the shade selection was performed by measuring the target tooth color using a spectrophotometer; and Group I, where the shade selection was performed by scanning the test specimens and target crowns using an intraoral scanner. Based on the test groups, 24 crowns were fabricated using different shade selection techniques. The ΔE values were calculated according to the CIEDE2000 (2:1:1) formula. The collected data were analyzed by means of a one-way analysis of variance. RESULTS. For the four test groups (Groups C, Ph, S, and I), the following mean ΔE values were obtained: 2.74, 3.62, 2.13, and 3.5, respectively. No significant differences were found among the test groups. CONCLUSION. Although there was no statistically significant difference among the shade selection techniques, Group S had relatively lower ΔE values. Moreover, according to the test results, the spectrophotometer shade selection technique may provide more successful clinical results.

Comparison of Vendor-Provided Volumetry Software and NeuroQuant Using 3D T1-Weighted Images in Subjects with Cognitive Impairment: How Large is the Inter-Method Discrepancy?

  • Chung, Jieun;Kim, Hayoung;Moon, Yeonsil;Moon, Won-Jin
    • Investigative Magnetic Resonance Imaging
    • /
    • 제24권2호
    • /
    • pp.76-84
    • /
    • 2020
  • Background: Determination of inter-method differences between clinically available volumetry methods are essential for the clinical application of brain volumetry in a wider context. Purpose: The purpose of this study was to examine the inter-method reliability and differences between the Siemens morphometry (SM) software and the NeuroQuant (NQ) software. Materials and Methods: MR images of 86 subjects with subjective or objective cognitive impairment were included in this retrospective study. For this study, 3D T1 volume images were obtained in all subjects using a 3T MR scanner (Skyra 3T, Siemens). Volumetric analysis of the 3D T1 volume images was performed using SM and NQ. To analyze the inter-method difference, correlation, and reliability, we used the paired t-test, Bland-Altman plot, Pearson's correlation coefficient, intraclass correlation coefficient (ICC), and effect size (ES) using the MedCalc and SPSS software. Results: SM and NQ showed excellent reliability for cortical gray matter, cerebral white matter, and cerebrospinal fluid; and good reliability for intracranial volume, whole brain volume, both thalami, and both hippocampi. In contrast, poor reliability was observed for both basal ganglia including the caudate nucleus, putamen, and pallidum. Paired comparison revealed that while the mean volume of the right hippocampus was not different between the two software, the mean difference in the left hippocampus volume between the two methods was 0.17 ml (P < 0.001). The other brain regions showed significant differences in terms of measured volumes between the two software. Conclusion: SM and NQ provided good-to-excellent reliability in evaluating most brain structures, except for the basal ganglia in patients with cognitive impairment. Researchers and clinicians should be aware of the potential differences in the measured volumes when using these two different software interchangeably.

A Comparative Study on Virtual Try-on Systems using Body Measurement Input

  • Lim, Ho-Sun;Istook, Cynthia
    • The International Journal of Costume Culture
    • /
    • 제13권2호
    • /
    • pp.118-129
    • /
    • 2010
  • Digital technology introduced into the clothing and fashion industry is evolving to digital virtual fashions and consumer-centered mass-customized production systems. Today the application of such 3D virtual try-on systems is being expanded gradually in the clothing industry. This study purposed to make virtual avatars and virtual garments using OptiTex and V-stitcher virtual software and compared the appearance of the virtual garments put on the virtual avatars. For this, we created virtual avatars and virtual garments using body measurements obtained from jive subjects of top jive body shapes, respectively, using $[TC]^2$ body scanner. According to the results of comparing the outcomes of the two different virtual software systems, virtual avatar II of V-Stitcher tended to have a more round and lifted hip and the waist line at a higher position. In addition, the body curves and shapes of a virtual avatar affect the appearance of virtual garments. This study applied the same body measurements to virtual avatars and the same pattern to virtual garments, but when different kinds of virtual software were used, the virtual avatars and virtual garments showed different appearance and fit. This result may mean that when customers buy apparel products using different kinds of virtual try-on systems, their evaluation of appearance can vary depending on the virtual try-on system. Therefore, research needs to be made actively for the development and use of linkage programs that can reflect actual body measurements between virtual software systems and 3D body scanning systems.

  • PDF

In vivo wear determination of novel CAD/CAM ceramic crowns by using 3D alignment

  • Aladag, Akin;Oguz, Didem;Comlekoglu, Muharrem Erhan;Akan, Ender
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권2호
    • /
    • pp.120-127
    • /
    • 2019
  • PURPOSE. To determine wear amount of single molar crowns, made from four different restoratives, and opposing natural teeth through computerized fabrication techniques using 3D image alignment. MATERIALS AND METHODS. A total of 24 single crowns (N = 24 patients, age range: 18 - 50) were made from lithium disilicate (IPS E-max CAD), lithium silicate and zirconia based (Vita Suprinity CAD), resin matrix ceramic material (Cerasmart, GC), and dual matrix (Vita Enamic CAD) blocks. After digital impressions (Cerec 3D Bluecam, DentsplySirona), the crowns were designed and manufactured (Cerec 3, DentsplySirona). A dualcuring resin cement was used for cementation (Variolink Esthetic DC, Ivoclar). Then, measurement and recording of crowns and the opposing enamel surfaces with the intraoral scanner were made as well as at the third and sixth month follow-ups. All measurements were superimposed with a software (David-Laserscanner, V3.10.4). Volume loss due to wear was calculated from baseline to follow-up periods with Siemens Unigraphics NX 10 software. Statistical analysis was accomplished by Repeated Measures for ANOVA (SPSS 21) at = .05 significance level. RESULTS. After 6 months, insignificant differences of the glass matrix and resin matrix materials for restoration/enamel wear were observed (P>.05). While there were no significant differences between the glass matrix groups (P>.05), significant differences between the resin matrix group materials (P<.05) were obtained. Although Cerasmart and Enamic were both resin matrix based, they exhibited different wear characteristics. CONCLUSION. Glass matrix materials showed less wear both on their own and opposing enamel surfaces than resin matrix ceramic materials.

Anatomic Description of the Infraorbital Soft Tissues by Three-dimensional Scanning System

  • Peralta, Alonso Andres Hormazabal;Choi, You-Jin;Hu, Hyewon;Hu, Kyung-Seok;Kim, Hee-Jin
    • Journal of Korean Dental Science
    • /
    • 제14권2호
    • /
    • pp.101-109
    • /
    • 2021
  • Purpose: For minimally invasive procedures, three-dimensional (3D) anatomical knowledge of the structures of the face is essential. This study aimed to describe the thickness of the skin and subcutaneous tissue and depths of the facial muscles located in the infraorbital region using a 3D scanner to provide critical clinical anatomical guidelines for improving minimally invasive cosmetic procedures. Materials and Methods: The 3D scanning images of 38 Korean cadavers (22 males and 16 females; age range: 51~94 years at the time of death) were analyzed. Eight facial landmarks (P1~P8) were marked on the cadaveric faces. The images were scanned in three steps-undissected face, hemiface after skinning, and revealing the facial muscles. Student's t-test was used to identify significant differences. Result: The skin and subcutaneous tissue tended to become thicker from the upper to lower and medial to lateral aspects, and the muscles followed the same pattern as that of the most superficial located muscle and the deepest located muscles. No significant sex-related differences were found in the skin at any landmark. However, the muscles tended to be deeper in the female participants. Conclusion: The study data can serve as a basis for creating or enhancing clinical anatomy-based guidelines or improving procedures in the infraorbital region.

A Study on Depth Information Acquisition Improved by Gradual Pixel Bundling Method at TOF Image Sensor

  • Kwon, Soon Chul;Chae, Ho Byung;Lee, Sung Jin;Son, Kwang Chul;Lee, Seung Hyun
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제7권1호
    • /
    • pp.15-19
    • /
    • 2015
  • The depth information of an image is used in a variety of applications including 2D/3D conversion, multi-view extraction, modeling, depth keying, etc. There are various methods to acquire depth information, such as the method to use a stereo camera, the method to use the depth camera of flight time (TOF) method, the method to use 3D modeling software, the method to use 3D scanner and the method to use a structured light just like Microsoft's Kinect. In particular, the depth camera of TOF method measures the distance using infrared light, whereas TOF sensor depends on the sensitivity of optical light of an image sensor (CCD/CMOS). Thus, it is mandatory for the existing image sensors to get an infrared light image by bundling several pixels; these requirements generate a phenomenon to reduce the resolution of an image. This thesis proposed a measure to acquire a high-resolution image through gradual area movement while acquiring a low-resolution image through pixel bundling method. From this measure, one can obtain an effect of acquiring image information in which illumination intensity (lux) and resolution were improved without increasing the performance of an image sensor since the image resolution is not improved as resolving a low-illumination intensity (lux) in accordance with the gradual pixel bundling algorithm.

광산에서의 ICT 장비 활용 및 안전시스템 운용 사례 연구 (Study on the ICT Device Safety System Application Examples in Mines)

  • 김승준;고영훈;김정규;서만근;김종관
    • 터널과지하공간
    • /
    • 제32권3호
    • /
    • pp.194-202
    • /
    • 2022
  • 2000년대 이후 자원개발 분야에서는 안전성, 친환경 및 저비용 등의 이유로 ICT 기술을 적용한 사례들이 증가되고 있다. 국내에서도 제 2차 광업기본계획에서 광업 전주기와 ICT 융합에 대한 중요성을 명시하고, 제 3차 광업기본계획에서는 국내에 ICT 광산장비 보급 지원 및 스마트마이닝 시범 도입 등 ICT와 스마트 마이닝에 대해 강조하고 있다. 본 연구는 (주)고려시멘트 장성 광업소에서의 ICT 장비의 활용과 안전시스템 운용에 대해 설명하였다. 장성 광업소에서는 측량과 3D 스캐닝이 가능한 멀티스테이션과 핸드형 3D 스캐닝 등 두 종류의 3D 장비를 혼용하여 갱도의 3D 측량을 실시하고 있다. 3D 측량을 통해서 각 편별 위험 개소 및 특이사항을 파악하고, 편과 편 사이의 크라운 필라에 대한 안정성을 분석하였다. 또한, 실시간 위치추적 및 통신시스템을 구축하여 갱내 사고에 대한 구조방안 및 대피계획을 수립하고 있다.