Browse > Article
http://dx.doi.org/10.5856/JKDS.2021.14.2.101

Anatomic Description of the Infraorbital Soft Tissues by Three-dimensional Scanning System  

Peralta, Alonso Andres Hormazabal (Division in Anatomy and Developmental Biology, Department of Oral Biology, Human Identification Research Institute, BK21 FOUR Project, Yonsei University College of Dentistry)
Choi, You-Jin (Division in Anatomy and Developmental Biology, Department of Oral Biology, Human Identification Research Institute, BK21 FOUR Project, Yonsei University College of Dentistry)
Hu, Hyewon (Division in Anatomy and Developmental Biology, Department of Oral Biology, Human Identification Research Institute, BK21 FOUR Project, Yonsei University College of Dentistry)
Hu, Kyung-Seok (Division in Anatomy and Developmental Biology, Department of Oral Biology, Human Identification Research Institute, BK21 FOUR Project, Yonsei University College of Dentistry)
Kim, Hee-Jin (Division in Anatomy and Developmental Biology, Department of Oral Biology, Human Identification Research Institute, BK21 FOUR Project, Yonsei University College of Dentistry)
Publication Information
Journal of Korean Dental Science / v.14, no.2, 2021 , pp. 101-109 More about this Journal
Abstract
Purpose: For minimally invasive procedures, three-dimensional (3D) anatomical knowledge of the structures of the face is essential. This study aimed to describe the thickness of the skin and subcutaneous tissue and depths of the facial muscles located in the infraorbital region using a 3D scanner to provide critical clinical anatomical guidelines for improving minimally invasive cosmetic procedures. Materials and Methods: The 3D scanning images of 38 Korean cadavers (22 males and 16 females; age range: 51~94 years at the time of death) were analyzed. Eight facial landmarks (P1~P8) were marked on the cadaveric faces. The images were scanned in three steps-undissected face, hemiface after skinning, and revealing the facial muscles. Student's t-test was used to identify significant differences. Result: The skin and subcutaneous tissue tended to become thicker from the upper to lower and medial to lateral aspects, and the muscles followed the same pattern as that of the most superficial located muscle and the deepest located muscles. No significant sex-related differences were found in the skin at any landmark. However, the muscles tended to be deeper in the female participants. Conclusion: The study data can serve as a basis for creating or enhancing clinical anatomy-based guidelines or improving procedures in the infraorbital region.
Keywords
Anatomy; Infraorbital region; Soft tissue; Thickness; Three-dimensional scanning;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Kusnoto B, Evans CA. Reliability of a 3D surface laser scanner for orthodontic applications. Am J Orthod Dentofacial Orthop 2002; 122: 342-8.   DOI
2 Hur MS, Youn KH, Kim HJ. New insight regarding the zygomaticus minor as related to cosmetic facial injections. Clin Anat 2018; 31: 974-80.   DOI
3 Hormazabal-Peralta A, Lee KW, Lee HJ, Choi YJ, Hu KS, Kim HJ. Clinical anatomy considerations on the muscular and vascular components of the midface by ultrasonographic imaging. Clin Anat 2021; 34: 1142-9.   DOI
4 Kaplan JB. Consideration of muscle depth for botulinum toxin injections: a three-dimensional approach. Plast Surg Nurs 2019; 39: 52-8.   DOI
5 Ozsoy U, Sekerci R, Hizay A, Yildirim Y, Uysal H. Assessment of reproducibility and reliability of facial expressions using 3D handheld scanner. J Craniomaxillofac Surg 2019; 47: 895-901.   DOI
6 Farolch-Prats L, Nome-Chamorro C. Facial contouring by using dermal fillers and botulinum toxin A: a practical approach. Aesthetic Plast Surg 2019; 43: 793-802.   DOI
7 Amornvit P, Sanohkan S. The accuracy of digital face scans obtained from 3D scanners: an in vitro study. Int J Environ Res Public Health 2019; 16: 5061.   DOI
8 Franco de Sa Gomes C, Libdy MR, Normando D. Scan time, reliability and accuracy of craniofacial measurements using a 3D light scanner. J Oral Biol Craniofac Res 2019; 9: 331-5.   DOI
9 Kim SH, Jung WY, Seo YJ, Kim KA, Park KH, Park YG. Accuracy and precision of integumental linear dimensions in a three-dimensional facial imaging system. Korean J Orthod 2015; 45: 105-12.   DOI
10 Surek CC, Beut J, Stephens R, Jelks G, Lamb J. Pertinent anatomy and analysis for midface volumizing procedures. Plast Reconstr Surg 2015; 135: 818e-29e.   DOI
11 Shirakabe Y, Suzuki Y, Lam SM. A new paradigm for the aging Asian face. Aesthetic Plast Surg 2003; 27: 397-402.   DOI
12 Ebrahim M. 3D laser scanners: history, applications, and future [Internet]. Saarbrucken: LAP LAMBERT Academic Publishing [cited 2021 May]. Available from: https://www.researchgate.net/publication/267037683_3d_laser_scanners_history_applications_and_future.
13 Kim HJ, Seo KK, Lee HK, Kim J. Clinical anatomy of the face for filler and botulinum toxin injection. 1st ed. Singapore: Springer; 2016.
14 Spiegel JH, DeRosa J. The anatomical relationship between the orbicularis oculi muscle and the levator labii superioris and zygomaticus muscle complexes. Plast Reconstr Surg 2005; 116: 1937-42; discussion 1943-4.   DOI
15 Petrides G, Clark JR, Low H, Lovell N, Eviston TJ. Three-dimensional scanners for soft-tissue facial assessment in clinical practice. J Plast Reconstr Aesthet Surg 2021; 74: 605-14.   DOI
16 Lee KW, Kim SH, Gil YC, Hu KS, Kim HJ. Validity and reliability of a structured-light 3D scanner and an ultrasound imaging system for measurements of facial skin thickness. Clin Anat 2017; 30: 878-86.   DOI
17 Chopra K, Calva D, Sosin M, Tadisina KK, Banda A, De La Cruz C, Chaudhry MR, Legesse T, Drachenberg CB, Manson PN, Christy MR. A comprehensive examination of topographic thickness of skin in the human face. Aesthet Surg J 2015; 35: 1007-13.   DOI
18 Kim YS, Lee KW, Kim JS, Gil YC, Tanvaa T, Shin DH, Kim HJ. Regional thickness of facial skin and superficial fat: application to the minimally invasive procedures. Clin Anat 2019; 32: 1008-18.   DOI
19 Ryu MH, Moon VA, Yin W. The inclusion of orbicularis oculi muscle in the SMAS Flap in Asian facelift: anatomical consideration of orbicularis muscle and zygomaticus major muscle. Aesthetic Plast Surg 2018; 42: 471-8.   DOI