• Title/Summary/Keyword: 2D Marker

Search Result 509, Processing Time 0.031 seconds

Computations of Free-Surface Flows by Use of Marker and Cell Method (MAC 방법을 이용한 자유표면 유동계산)

  • PARK Jong-Chun;SHIN Myung-Soo;VAN Suak-Ho;KIM Wu-Joan
    • 한국전산유체공학회:학술대회논문집
    • /
    • 1995.10a
    • /
    • pp.138-147
    • /
    • 1995
  • The boundary conditions for the free-surface including the important meaning for both scientific and engineering purposes are described together with the numerical techniques to implement the conditions. Two kinds of numerical method based on MAC method are introduced. One is applied to the problem of 2D solitary wave propagation and the other is applied to the problem of 3D bow wave breaking.

  • PDF

Whole Mitochondrial Genome Sequence of an Indian Plasmodium falciparum Field Isolate

  • Tyagi, Suchi;Pande, Veena;Das, Aparup
    • Parasites, Hosts and Diseases
    • /
    • v.52 no.1
    • /
    • pp.99-103
    • /
    • 2014
  • Mitochondrial genome sequence of malaria parasites has served as a potential marker for inferring evolutionary history of the Plasmodium genus. In Plasmodium falciparum, the mitochondrial genome sequences from around the globe have provided important evolutionary understanding, but no Indian sequence has yet been utilized. We have sequenced the whole mitochondrial genome of a single P. falciparum field isolate from India using novel primers and compared with the 3D7 reference sequence and 1 previously reported Indian sequence. While the 2 Indian sequences were highly divergent from each other, the presently sequenced isolate was highly similar to the reference 3D7 strain.

On the Voiced-Voiceless Distinction in Stops of English

  • Kim, Dae-Won
    • Korean Journal of English Language and Linguistics
    • /
    • v.2 no.1
    • /
    • pp.23-30
    • /
    • 2002
  • Phonologically, the difference between the English stops /b, d, g/ and /p, t, k/ is carried by the presence or the absence of the vocal fold vibration throughout their oral closure phase. If phonology has its foundation in phonetics, there must be phonetic evidence for the voiced-voiceless distinction. This study is aimed to determine whether or not the voiced-voiceless distinction is acceptable or proper in English. The determination was based mainly on findings in the existing literature and in informal experiments. In conclusion, there is no phonetic evidence for the voiced-voiceless distinction both in production and perception. The [voice] appears to be one of potential phonetic correlates of the phonologically voiced stop. It is improper to use the [voice] as independent phonological marker, regardless of position (word-initial, intervocalic, word-final). A feature other than the voiced-voiceless feature must distinguish /b, d, g/ from /p, t, k/.

  • PDF

Phenanthrene Derivatives, 3,5-Dimethoxyphenanthrene-2,7-diol and Batatasin-I, as Non-Polar Standard Marker Compounds for Dioscorea Rhizoma

  • Yoon, Kee-Dong;Yang, Min-Hye;Nam, Sang-Il;Park, Ju-Hyun;Kim, Young-Choong;Kim, Jin-Woong
    • Natural Product Sciences
    • /
    • v.13 no.4
    • /
    • pp.378-383
    • /
    • 2007
  • Phenathrene derivatives, such as batatasins, are well-known constituents in Dioscorea Rhizoma. Although phenanthrenes have been reported as representative compounds in this plant, standard markers for quality control have been focused on the polar constituents (saponins and purine derivatives). Herein, simple, rapid and reliable HPLC method was developed to determine 3,5-dimethoxyphenanthrene-2,7-diol (DMP) and batatasin-I (BA-I) as non-polar standard maker compounds of Dioscorea Rhizoma. DMP and BA-I were analyzed under optimized HPLC conditions [column: Columbus $5{\mu}$ C18 100A ($30{\times}4.6mm$ i.d., $5{\mu}m$; mobile phase: $H_2O$ with 0.025% $CH_3COOH$ (v/v) for solvent A and $CH_3CN$ with 0.025% $CH_3COOH$ (v/v) for solvent B, gradient elution; flow rate: 2 mL/min; detection: 260 nm), and each experiment was finished within 13 min. Good linearity was achieved in the range from 0.5 to $10.0{\mu}g/mL$ for each compound, and intra- and inter-day precision were in the acceptable levels. The recovery test were performed with three different Dioscorea Rhizoma samples (D. opposita, D. batatas and D. japonica), and showed its accuracy values in the range of 97.2 - 102.8% for three different concentrations of DMP and BA-I. The content levels of DMP and BA-I were ranged under 0.0020%. These results demonstrated that amounts of DMP and BA-I are easily determined with conventional HPLC-UV-DAD method although the content levels were lower than those of saponins and allantoin in Dioscorea Rhizoma. This HPLC method could be used for quality control of various Dioscorea preparations.

Genetical and Pathological Studies on the Mutant Mice as an Animal Model for Deafness Disease

  • Lee, Jeong-Woong;Lee, Eun-Ju;Lee, Hoon-Taek;Chung, Kil-Saeng;Ryoo, Zae-Young
    • Proceedings of the KSAR Conference
    • /
    • 2001.03a
    • /
    • pp.48-48
    • /
    • 2001
  • A new neurological mutant has been found in the ICR outbred strain mouse. Affected mice display profound deafness and a head-tossing and bidirectional circling behavior, showing an autosomal recessive mode of inheritance. It was, therefore, named cir/Kr with the gene symbol cir. The auditory tests identified clearly the hearing loss of the cir mice when compared to wild type mice. Pathological studies confirmed the developmental defects in the middle ear, cochlea, cochlear nerve, and semicircular canal areas, which were correlated to the abnormal behavior observed in the cir mice. Thus, cir mice may be useful as a model for studying inner ear abnormalities and deafness. We have constructed a genetic linkage map by positioning 14 microsatellite markers across the (cir) region and intraspecific backcross between cir and C57BL/6J mice. The cir mouse harbors an autosomal recessive mutation on mouse chromosome 9. The cir gene was mapped to a region between D9Mit116 and D9Mit38 Estimated distances between cir and D9Mit116, and between cir and D9Mit38 are 0.7 and 0.2 cM, respectively. The gene in order was defines : centromere-D9Mit182-D9Mit51/D9Mit79/D9Mit310-D9Mit212/D9Mit184-D9Mit116-cir-D9Mit38-D9Mit20-D9Mit243-D9Mit16-D9Mit55/D9Mit125-D9Mit281. The mouse map location of the cir locus appears to be in a region homologous to human 3q21. Our present date suggest that the nearest flanking marker D9Mit38 provides a useful anchor for the isolation of the cir gene in a yeast artificial chromosome contig.

  • PDF

Prognostic Value of Fibroblastic Foci in Patients with Usual Interstitial Pneumonia (통상성 간질성 폐렴 환자 예후인자로서의 섬유모세포병소(fibroblastic foci)의 유용성)

  • Park, Yong-Bum;Kang, Gil-Hyun;Shim, Mae-Sun;Lim, Chae-Man;Lee, Sang-Do;Koh, Youn-Suck;Kim, Woo-Sung;Kim, Won-Dong;Kitaichi, Masanori;Kim, Dong-Soon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.53 no.3
    • /
    • pp.309-318
    • /
    • 2002
  • Background : Usual interstitial pneumonia (UIP) is a fatal progressive fibrotic disorder of the lung with unknown etiology and characterized by a poor response to conventional immunosuppressive therapy. The histologic hallmark of UIP is parchy distribution of subpleural fibrosis and fibroblastic foci(FBF) with interposed normal appearing lung. Because FBF is a collection of actively proliferating myofibroblasts, it can be a marker of activity and prognosis of UIP. However, there were contradictory reports about the correlation between the degree of FBF and survival. Therefore we performed this study to investigate the value of FBF as prognostic marker of UIP. Methods : This was a retrospective study on the 46 patients(M:F=33:13, mean age:$59{\pm}12$ years) with UIP diagnosed by the surgical lung biopsy at the Asan Medical Center, Seoul, Korea between 1990 and 2000 and had follow-up of more than a year. All the biopsy specimens were reevaluated and diagnosed as UIP according to the ATS/ERS classification. Semiquantitative grading of FBF(absent, 0; mild 1; moderate 2; marked 3) by the experienced pathologists who did not know the clinical findings were compared to the clinical data and the follow up course. Results : Thirteen patients(28.2%) died of UIP progression during the study period. The median survival time of all the subjects was 26 months after the biopsy. At the univariate analysis, FVC, $D_Lco$, smoking history and the grade of FBF were significantly related to the survial. The survival was longer in subjects with lesser degrees of FBF, higher DLco, higher FVC and history of smoking. However the multivariate analysis with Cox regression test showed the extent of FBF was the only independent prognostic marker of UIP. Conclusion : These data suggested that the extent of FBF on the surgical lung biopsy can be used as a prognostic marker of UIP.

Effect of External Load on Shoulder Joint Active Relocation Using 3D Motion Capture System: A Pilot Study (외부 하중이 어깨관절의 능동적 재위치 검사 결과에 미치는 영향: 3차원 동작 분석 시스템을 이용한 예비연구)

  • Hwang, Jisun;Hwang, Seonhong
    • Physical Therapy Korea
    • /
    • v.25 no.2
    • /
    • pp.71-77
    • /
    • 2018
  • Background: There are insufficient objective or quantitative evidence for the better intervention to improve proprioception particularly for the application of external load. There are conflicting opinions whether the external load is effective for proprioception improvement or not. Objects: The purpose of this study was to investigate effects of external load on proprioception of shoulder joint quantitatively using 3D motion capture system. Methods: Nine healthy adults joined for this study. They were asked to perform scapular plane abduction motion with attaching reflective markers on the trunk and upper limb. The 3D positions of finger marker, while they performed the same task with and without external load, were recorded and analyzed. Results: All participants showed decreased variable errors in the vertical direction when the external load was applied (p<.02). Even though other directions (y, z) and absolute errors increased, they did not have statistical significances. Conclusion: Based on this study results, the external load application would be effective for shoulder joint position sense improvement.

Incompressible Viscous Flow Analysis around a High-Speed Train Including Cross-Wind Effects (측풍영향을 고려한 고속전철 주위의 비압축성 점성 유동 해석)

  • Jung Y. R.;Park W. G.;Kim H. W.;Ha S. D.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 1995.10a
    • /
    • pp.55-63
    • /
    • 1995
  • The flow field around a high-speed train including cross-wind effects has been simulated. This study solves 3-D unsteady incompressible Navier-Stokes equations in the inertial frame using the iterative time marching scheme. The governing equations are differenced with 1st-order accurate backward difference scheme for the time derivatives, 3th-order accurate QUICK scheme for the convective terms and 2nd-order accurate central difference scheme for the viscous terms. The Marker-and-Cell concept was applied to efficiently solve continuity equation, which is differenced with 2nd-order accurate central difference scheme. The 4th-order artificial damping is added to the continuity equation for numerical stability. A C-H type of elliptic grid system is generated around a high-speed train including ground. The Baldwin-Lomax turbulent model was implemented to simulate the turbulent flows. To validate the present procedure, the flow around a high speed train at constant yaw angle of $45^{\circ}\;and\;90^{\circ}$ has been simulated. The simulation shows 3-D vortex generation in the lee corner. The flow separation is also observed around the rear of the train. It has concluded that the results of present study properly agree with physical flow phenomena.

  • PDF

Properties Characterization of the Hydrophilic Inorganic Film as Function of Coating Thickness (코팅 두께에 따른 친수성 무기 필름의 특성 분석)

  • Joung, Yeunho;Choi, Won Seok;Shin, Yongtak;Lee, Minji;Kim, Heekon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.6
    • /
    • pp.425-428
    • /
    • 2013
  • In this paper, we present a novel hydrophilic coating material (Wellture Finetech, Korea) which can be utilized as a coating layer for anti-contamination for electrical and electronic system. The coating material was deposited on 4 inch silicon wafer with several different film thickness. The film thickness was controlled by spin coating speed. After curing of the film, we have scratched by permanent marker to check self-cleaning property of the film. Also we have executed several mechanical tests of the films. As the spin coating speed is increased, the film thickness was thinned from 230 nm to 125 nm. Contact angle of the film was lowered from $30^{\circ}$ to $12^{\circ}$ as the spin coating speed is increased from 700 to 2,500 rpm. On permanent marker scratched film surface coated at 1,000 rpm, we have poured regular city water to investigate self cleaning property of the film. The scratches were gradually separated from the film surface due to super-hydrophilicity of the film. Hardness of spin coated film was 9H measured by ASTM D3363 method. and adhesion of all film was 5B tested by ASTM D3359 method. Also, to get exact hardness value of the film, we have utilized a nano-indenter. As spin speed is increased, the hardness of film was increased from 3 GPa to 5 GPa.

Development of Quality Control Method for a Novel Herbal Medicine, HPL-1 using UHPLC (UHPLC를 이용한 새로운 한약제제 HPL-1의 품질관리법 개발)

  • Kim, Se-Gun;Lamichhane, Ramakanta;Lee, Kyung-Hee;Jung, Hyun-Ju
    • The Korea Journal of Herbology
    • /
    • v.30 no.3
    • /
    • pp.19-24
    • /
    • 2015
  • Objectives : HPL-1, a novel herbal medicine which is composed of five herbs such as Kalopanacis Cortex, Chaenomelis Fructus, Raphani Semen, Atractylodis Rhizoma and Pulvis Aconiti Tuberis Purificatum, was developed for treatment of osteoarthritis. This study is aimed to develop analytical method for consistent quality control of HPL-1 and validate chromatographic method. Methods : Chromatographic analysis was performed using ultra-high performance liquid chromatography - diode array detector (UHPLC-DAD) equipped with RP-amide column, column oven, and auto sampler. Marker compounds [protocatechuic acid, chlorogenic acid, liriodendrin, 3,5-dicaffeoylquinic acid, ${\beta}$-D-(3-O-sinapoyl)-fructofuranosyl-$\alpha$-D-(6-O-sinapoyl)glucopyranoside and benzoylmesaconine] were separated by step gradient elution of acetonitrile and 0.1% phosphoric acid/water. The method validation was evaluated by quantitative validation parameters of linearity, accuracy, precision, limit of detection (LOD) and limit of quantification (LOQ) according to KFDA guideline.Results : An optimized method for six marker compounds in HPL-1 was established by UHPLC-DAD. The correlation coefficient (R2) with each calibration curve was greater than 0.99. The LOD and LOQ were within the range of 0.008-0.090 and $0.023-0.274{\mu}g/mL$, respectively. The relative standard deviation (RSD) of intra- and inter-day variability were less than 4.0%. The result of recovery test was range from 93.3-106.3% with RSD < 4.0%.Conclusions : These results suggest that the quantitative UHPLC method is precise, accurate, effective for quality evaluation of HPL-1. The method may also contribute to improve quality of crude drug preparations used for treatment of various diseases.