• 제목/요약/키워드: 2D Laser Scanning System

검색결과 58건 처리시간 0.025초

나노 정밀도 스캐닝 용 공기베어링과 보이스 코일 모터의 초정밀 이중 스테이지 설계 및 제어 (Design and Control of Ultra-precision Dual Stage with Air bearings and Voice coil motor for nm scanning system)

  • 김기현;최영만;김정재;이문구;이석원;권대갑
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1883-1886
    • /
    • 2005
  • In this paper, a decoupled dual servo (DDS) stage for ultra-precision scanning system with large working range is introduced. In general, dual servo systems consist of a fine stage for short range and a coarse stage for long range. The proposed DDS also consists of a $XY\theta$ fine stage for handling and carrying workpieces and one axis coarse stage. Its coarse stage consists of air bearing guide system and a coreless linear motor with force ripple. The fine has four voice coil motors(VCM) as its actuator. According to a VCM's nature, there are no mechanical connections between coils and magnetic circuits. Moreover, VCM doesn't have force ripples due to imperfections of commutation components of linear motor systems - currents and flux densities. However, due to the VCM's mechanical constraints the working range of the fine is about $25mm^2$. To break that hurdle, the coarse stage with linear motors is used to move the fine about 500mm. Because of the above reasons, the proposed DDS can achieve higher precision scanning than other stages with only one servo. With MATLAB's Sequential Quadratic Programming (SQP), the VCMs are optimally designed for the highest force under conditions and constraints such as thermal dissipations due to its coil, its size, and so on. And for their movements without any frictions, guide systems of the DDS are composed of air bearings. To get precisely their positions, a linear scale with 5nm resolution are used for the coarse stage's motion and three plane mirror laser interferometers with 5nm for the fine's $XY\theta$ motions. With them, on scanning the two stages have same trajectories. The control algorithm is named Parallel method. The embodied ultra-precision scanning system has sub 100nm following error and in-positioning stability.

  • PDF

안면 입체영상 중첩시 중첩 기준 범위 설정에 따른 적합도 차이 (VALIDITY OF SUPERIMPOSITION RANGE AT 3-DIMENSIONAL FACIAL IMAGES)

  • 최학희;조진형;박홍주;오희균;최진휴;황현식;이기헌
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제31권2호
    • /
    • pp.149-157
    • /
    • 2009
  • Purpose: This study was to evaluate the validity of superimposition range at facial images constructed with 3-dimensional (3D) surface laser scanning system. Materials and methods: For the present study, thirty adults, who had no severe skeletal discrepancy, were selected and scanned twice by a 3D laser scanner (VIVID 910, Minolta, Tokyo, Japan) with 12 markers placed on the face. Then, two 3D facial images (T1-baseline, T2-30 minutes later) were reconstructed respectably and superimposed in several manners with $RapidForm^{TM}2006$ (Inus, Seoul, Korea) software program. The distances between markers at the same place of face were measured in superimposed 3D facial images and measurement were done all the 12 makers respectably. Results: The average linear distances between the markers at the same place in the superimposed image constructed by upper 2/3 of the face was $0.92{\pm}0.23\;mm$, in the superimposed image constructed by upper 1/2 of the face was $0.98{\pm}0.26\;mm$, in the superimposed image constructed by upper 1/3 of the face and nose area was $0.99{\pm}0.24\;mm$, in the superimposed image constructed by upper 1/3 of the face was $1.41{\pm}0.48\;mm$, and in the superimposed image constructed by whole face was $0.83{\pm}0.13\;mm$. There were no statistically significant differences in the liner distances of the makers placed on the area included in superimposition range used for partial registration methods but there were significant differences in the linear distances of the markers placed on the areas not included in superimposition range between whole registration method and partial registration methods used in this study. Conclusion: The results of the present study suggest that the validity of superimposition is decreased as superimposition range is reduced in the superimposition of 3D images constructed with 3D laser scanner for the same subject.

실시간 차종인식 시스템의 설계 및 구현 (Design and Implementation of a Real-Time Vehicle's Model Recognition System)

  • 최태완
    • 한국정보통신학회논문지
    • /
    • 제10권5호
    • /
    • pp.877-889
    • /
    • 2006
  • 교통제어나 차량에 연관된 범죄 등에서 자동차의 인식에 관한 연구의 중요성 때문에 이에 관련된 연구는 오래전부터 수행되어 왔다. 본 논문에서는 차량이 주행할 때의 정보와 영상을 획득하여 제조회사별 차종을 인식하는 방법을 제안하고자 한다. 본 논문의 차종인식은 차량의 압력을 이용한 차폭 검출방법, 그리고 보다 더 정확한 인식률을 얻기 위한 레이저 거리계를 이용한 차고 검출방법, $3\sim5$종의 구별을 위 한 차량의 번호판 인식 방법을 조합함으로써 차량 인식의 오류를 줄이는 시스템을 구현하였다. 구현된 차종인식 시스템은 2차원 CCD에 의한 차량의 영상획득과 이를 통한 다양한 영상처리 알고리즘에 의해서 국내의 전 차종에 적용할 수 있으며, 실제의 실험 결과는 높은 인식률을 나타내었다.

THE EFFECT OF GOLD ELECTROFORMING PROCEDURE ON GOLD-SILVER-PALLADIUM ALLOY

  • Hwang, Bo-Yeon;Kim, Chang-Whe;Lim, Young-Jun;Kim, Myung-Joo
    • 대한치과보철학회지
    • /
    • 제45권3호
    • /
    • pp.303-309
    • /
    • 2007
  • Statement of problem. The effect of gold electroforming on gold alloy was not studied. Purpose. This in vitro study investigate the effect of gold electroforming on gold-silver-palladium alloy. Material and methods. Three pieces of gold strips had undergone the electroforming procedures on one side and then half of the side again electroformed. The set mode for this study was program 1 ($200{\mu}m$). And the processing time was 15min (1/20 time to form $200{\mu}m$ coping). The confocal laser scanning microscope (PASCAL 5, Carl Zeiss, Bernried, Germany) was used to measure the thickness of the pure gold layer electroformed on the gold strips. Half of the gold strip was coated two times with electroformed gold, and the other half one time. The data from the cone focal laser system was processed to get the vertical profile of the strips and the difference of the vertical height between the double coated and single coated layer was regarded as the thickness of the gold coating. The layer thickness value to built 3D image of the cone-focal laser was set $0.5{\mu}m$. Next to the measurement of the thickness of the coating, the Vicker's hardness test was done. It was performed on the double coated surface, single coated surface and non-coated surface (back side) three times each. Results. The mean thickness value gained from gold electroforming technique was measured to be $22{\mu}m$ for sample 1, $23{\mu}m$ for sample 2, $21{\mu}m$ for sample 3. In the same condition of time, power and the amount of electrolyte, the data showed no difference between samples. According to the results of variance analysis, the differences among the variations in number of coating were statistically insignificant (p>0.05), meaning that the two times of gold electroforming coating did not change the hardness of gold-silver-palladium alloy. Conclusion. The test of thickness of gold coating proved the coherency of the gold electroforming procedure, in other words, when the power, the exposed surface area, processing time and the amount of electrolytes were set same, the same thickness of gold would be coated on. The hardness test showed that the electroformed gold coating did not change the hardness of the gold-silver-palladium alloy when it is coated not more than $45{\mu}m$.

디지털 산림자원정보 구축을 위한 최적의 지상LiDAR 스캔 경로 분석 (Analysis of Optimal Pathways for Terrestrial LiDAR Scanning for the Establishment of Digital Inventory of Forest Resources)

  • 고치웅;임종수;김동근;강진택
    • 대한원격탐사학회지
    • /
    • 제37권2호
    • /
    • pp.245-256
    • /
    • 2021
  • 본 연구는 LiDAR 센서의 산림자원조사 적용성 검토를 위하여 제주 절물자연휴양림을 대상으로 삼나무의 개체목 탐지, 흉고직경과 수고를 측정하여 전통적인 산림자원조사와 정확성과 효율성을 비교·분석하였다. 백팩형 지상라이다(Backpack Personal Laser Scanning; BPLS)는 Greenvalley International 사(社)의 Model D50을 사용하였다. 최적의 데이터 수집을 위하여 표준지의 밀도와 작업 효율성을 고려한 LiDAR스캔의 표본추출방법을 7가지로 구분하였다. 분석은 개체목 변수 측정의 정확성을 파악하고 요소작업별 시간과 전체 분석시간을 조사하여 효율성을 평가하였다. 분석 결과, 백팩형 지상라이다를 이용한 입목 탐지율은 모든 패턴이 100%로 나타났다. 정확성은 패턴5(흉고직경: RMSE: 1.07 cm, Bias: -0.79 cm, 수고: RMSE: 0.95 m, Bias: -3.2 m)와 패턴7(흉고직경: RMSE: 1.18 cm, Bias: -0.82 cm, 수고: RMSE 1.13 m, Bias: -2.62 m)이 현장조사 방법으로 얻은 결과와 비교하였을 때 통계적 정확성이 높은 결과를 보였다. BPLS와 현장조사를 이용하여 1 ha의 데이터를 처리하는데 걸린 시간을 환산한 결과 BPLS는 약 115분~135분이 소요되며, 현장조사방법은 375분~1,115분으로 BPLS를 이용한 방법이 더 효율적인 것으로 나타났다. 따라서 하층식생이 적고 비교적 관리가 잘 된 인공 침엽수림에서는 BPLS 장비를 활용하여 효율적인 산림자원조사가 가능하며, 앞으로 다양한 임분 조건에서 적용 가능성을 분석할 필요가 있다고 판단된다.

이광자 광중합의 윤곽선 스캐닝법에 의한 마이크로 입체형상 제작 (Fabrication of Microstructures Using Double Contour Scanning (DCS) Method by Two-Photon Polymerization)

  • 박상후;임태우;이상호;양동열;공흥진;이광섭
    • 폴리머
    • /
    • 제29권2호
    • /
    • pp.146-150
    • /
    • 2005
  • 본 연구는 수십 마이크로미터 크기의 임의의 3차원 형상제작을 위한 이광자 광중합에 의한 나노 입체 리소그래피(nano-stereolithography) 공정개발에 관한 것이다. 본 연구에서 제안한 공정은 3차원 CAD 파일을 이용하여 형상의 윤곽선을 고화시켜서 연속적으로 적층하여 구조물을 제작하는 공정으로 기존의 리소그래피 공정과 달리 복잡한 형상제작이 가능하다. 형상제작은 펨토초 레이저를 이용하여 이광자 흡수 색소가 첨가된 아크릴레이트 계열의 단량체에 이광자 중합반응으로 제작하였으며 선 폭 정밀도는 150 nm수준이었다. 이광자 광중합법으로 윤곽선을 고화시켜 쉘(shell) 형태로 3차원 형상을 제작할 때에는 기계적 강성이 약하여 고화 후에 용매로 중합반응이 일어나지 않는 부분을 제거할 때 변형이 쉽게 발생하게 된다. 본 연구에서는 이러한 문제점을 해결하고자 윤곽 쉘 두께를 증가시켜 윤곽선을 중첩으로 제작하는 이중 윤곽선 스캐닝 방법(double contour scanning)을 시도하였으며 이를 통하여 제작된 형상의 강도가 향상됨을 확인할 수 있었다.

UAS 영상기반 문화유산물의 정밀 3차원 현상 모델링 (The Precise Three Dimensional Phenomenon Modeling of the Cultural Heritage based on UAS Imagery)

  • 이용창;강준오
    • 지적과 국토정보
    • /
    • 제49권1호
    • /
    • pp.85-101
    • /
    • 2019
  • 컴퓨터기술의 발달, 영상해석 기술의 고도화 및 경량 무인항공기(UAV)가 대중화되면서 'UAV와 각종 센서의 융합을 기반으로 한 응용시스템(UAS)'이 산업계 전반으로 확산되고 있다. 국가문화유산물의 기록, 유지 관리는 물론 파손 시 복구를 위해서는 효율적인 정밀 3차원 현상 모델링 재현과 주기적 육안점검 기술이 필요하다. 본 연구의 목적은 초대형 마애보살입상의 정밀 현상모델링 재현과 육안점검의 대안으로 UAS 영상을 기반으로 한 사진측량방법의 효용성을 검증하는 것이다. 이를 위해 고려시대(918-1392) 제작된 국내 최대 마애불이며 당초문양의 '보관(모자)'이 특징인 보물 제1324호, 시흥 소래산 마애보살입상을 대상으로 UAS 영상을 획득하고 검사점에 대한 UAS 영상해석과 토탈스테이션 측량시스템 간의 측위정확도를 비교하였다. 또한, 실세계좌표계 상의 3차원 현상모델링 및 선각 현상을 도화하여 문화재청의 정량적 규격 값과 비교하며 유지관리를 위한 육안점검 작업의 대체 가능성을 검토하였다. 특히, UAS 영상해석과 지상 레이저 스캐너에 의한 3차원 재현 모형간의 중첩해석을 통해 두 기법간의 활용성은 물론 2년 전 후의 상대적 변동 상태를 검토하였다. 연구결과, 대형 마애보살입상의 정밀 현상조사 및 육안점검의 대안으로 UAS 영상 해석법의 효용성을 확인할 수 있었으므로 향후, 대형 국가문화유산의 현상조사와 유지관리에 그 활용이 기대된다.

CAD-CAM을 이용한 3D printing, milling, casting 방법의 비귀금속 코핑의 지대치 변연 적합도 연구 (Influence of finish line design on the marginal fit of nonprecious metal alloy coping fabricated by 3D printing, milling and casting using CAD-CAM)

  • 김서랑;김명주;박지만;김성균;허성주;곽재영
    • 대한치과보철학회지
    • /
    • 제61권1호
    • /
    • pp.1-17
    • /
    • 2023
  • 목적: 본 연구의 목적은 레이져 신터링, 컴퓨터 밀링, 주조의 세 가지 방법으로 제작된 비귀금속 합금 코핑의 변연 형태에 따른 변연 적합도의 변화를 관찰하는 데 있다. 재료 및 방법: 서로 다른 두 개의 변연 형태를 정확히 재현하기 위해 3D Computer-aided Design을 이용하여 지대치 삭제의 원칙에 따라 지대치를 디자인한 다음, 티타늄 블럭을 컴퓨터 밀링하여 주모델을 제작하였다. 각각의 모델에 대하여 위의 3가지 제작 방식으로 비귀금속 합금 코핑을 12개씩 제작하여, 총 72개의 코핑을 제작하였다. 각 코핑은 지대치에 적합시켜서 공초점 레이저 주사 현미경으로 근심, 협측, 원심, 설측 변연의 변연 적합도를 150배율로 측정하였다. 결과: 레이져 신터링으로 제작한 코핑의 평균 변연 오차는 deep chamfer margin에서 11.8 ± 7.4 ㎛, rounded shoulder margin에서 6.3 ± 3.5 ㎛ 였고, 그 차이는 통계적으로 유의했다 (P < .0001). 컴퓨터 밀링으로 제작한 그룹에서는 deep chamfer margin에서 53.9 ± 27.8 ㎛, rounded shoulder margin에서 48.6 ± 30.0 ㎛였고, 변연 형태에 따른 유의한 차이가 없었다 (P = .279). 주조 방법으로 제작한 그룹은 deep chamfer margin에서 18.8 ± 20.2 ㎛, rounded shoulder margin 에서 30 ± 20.5 ㎛ 였고, 그 차이는 통계적으로 유의했다 (P = .0004). 결론: 이번 실험을 통하여, 다음과 같은 결론을 얻었다. 1. 변연의 형태에 따른 변연 적합도는 레이져 신터링이나 주조 방법으로 제작된 금속 코핑의 경우 변연 형태에 따라 유의한 차이가 있었다. 2. 레이져 신터링으로 제작한 금속 코핑에서 rounded shoulder margin이 deep chamfer margin보다 우수한 변연 적합도를 보였다. 3. 주조 방법으로 제작한 금속 코핑의 경우는 deep chamfer margin이 rounded shoulder margin보다 우수한 변연 적합도를 보였다. 4. 제작 방식에 따른 코핑의 변연 적합도는 레이져 신터링이 가장 양호하였고, 그 다음 주조 방법과 밀링 방법 순으로 변연 적합도 양호하였다. 이번 연구를 통해, 지대치의 변연 형태에 따른 금속 코핑의 변연 적합도의 변화를 관찰하였으며, 레이져 신터링으로 제작하거나 디지털 밀링한 왁스 패턴을 캐스팅한 경우에는 상관 관계가 있음을 확인하였다. 임상에 적용함에 있어 지대치의 변연 형태를 고려하여 제작 방식을 결정하는 것이 추천된다.

편광 기반 주파수 스캐닝 간섭 시스템 및 병렬 프로그래밍 기반 측정 고속화 (A Polarization-based Frequency Scanning Interferometer and the Measurement Processing Acceleration based on Parallel Programing)

  • 이승현;김민영
    • 전자공학회논문지
    • /
    • 제50권8호
    • /
    • pp.253-263
    • /
    • 2013
  • 광학측정기법 중 주파수 스캐닝 간섭계는 기존 3차원 측정기법과 비교하여 광학 하드웨어 구조가 측정과정동안 고정되어 있어, 대물렌즈나 대상물체의 수직 스캐닝 없이 단지 광원의 주파수만 특정한 주파수 밴드내에서 스캐닝 하여 대상물체에 주사되므로, 우수한 광학 측정 성능을 보인다. 광원의 주파수를 변경하여 간섭계를 통해 간섭 영상을 획득한 후, 밝기 영상 데이터를 주파수 영역 데이터로 변환하고, 고속 푸리에 변환을 통한 주파수 분석을 이용하여 대상 물체의 높이 정보를 계측한다. 하지만, 대상물체의 광학적 특성에 기인한 광학노이즈와 주파수 스캐닝동안 획득되는 영상의 수에 따라 증가하는 영상처리시간은 여전히 주파수 스캐닝 간섭계의 문제이다. 이를 위해, 1) 편광기반 주파수 스캐닝 간섭계가 광학 노이즈에 대한 강인성을 확보하기 위해 제안되어진다. 시스템은 주파수 변조 레이저, 참조 거울 앞단의 ${\lambda}/4$ 판, 대상 물체 앞단의 ${\lambda}/4$ 판, 편광 광분배기, 이미지 센서 앞단의 편광기, 광섬유 광원 앞단의 편광기, 편광 광분배기와 광원의 편광기 사이에 위치하는 ${\lambda}/2$ 판으로 구성된다. 제안된 시스템을 이용하여, 편광을 기반으로한 간섭이미지의 대조대비를 조절할 수 있다. 2) 신호처리 고속화 방법이 간섭계 시스템을 위해 제안되며, 이는 그래픽 처리 유닛(GPU)과 같은 병렬처리 하드웨어와 계산 통합 기기 구조(CUDA)와 같은 프로그래밍 언어로 구현된다. 제안된 방법을 통해 신호처리 시간은 실시간 처리가 가능한 작업시간을 얻을 수 있었다. 최종적으로 다양한 실험을 통해 제안된 시스템을 정확도와 신호처리 시간의 관점으로 평가하였고, 실험결과를 통해 제안한 시스템이 광학측정기법의 실적용을 위해 효율적임을 보였다.

음이온 계면활성제에서 파파인 효소의 안정도에 관한 연구 (A Study on the Stabilization of the Papain Enzyme in the Moderately Concentrated Anionic Surfactant System)

  • 김지영;김진우;김용진;이재욱;이해광;강학희
    • 대한화장품학회지
    • /
    • 제33권2호
    • /
    • pp.93-97
    • /
    • 2007
  • 일반적으로 음이온 계면활성제는 효소의 disulfide bond를 분해시켜 효소의 활성이 없어진다. 따라서 특정한 캡슐에 효소를 포집하여 안정도를 증대시킨다. 본 연구에서는 polyethylene glycol (PEG), polypropylene glycol (PPG), 그리고 PEG-PPG-PEG block copolymer 등의 폴리올을 이용하여 papain 효소의 안정도를 증대시켰다. Energy dispersive spectroscopy (EDS)와 confocal laser scanning microscope (CLSM) 분석을 통하여 폴리올은 고분자층과 효소의 중간에 위치하며, 이들은 완충액으로 작용하여 효소의 안정도를 증대시키는 것으로 확인하였다. 또한, 이온 복합체를 이용하여 다층 캡슐을 제조하여 wash-off 형태의 세정제에 응용하였다. 세정제 내에서 계면활성제와 물은 효소캡슐의 표면에 분산되었으며, 캡슐의 중앙부분으로 서서히 침투되었다. 반면에 본 연구에서 사용된 sodium lauroyl sarcosinate와 polyguaternium-6는 물이 효소부분으로 침투하지 않는 것을 in vivo 시험을 통하여 확인하였다.