• Title/Summary/Keyword: 22

Search Result 77,918, Processing Time 0.101 seconds

Effectiveness Evalution of 18F-FDG Auto Dispenser (RIID: Radiopharmaceutical Intelligent Dispenser) (18F-FDG 자동분주기 사용에 따른 유용성 평가)

  • Yoo, Moon-Gon;Moon, Jae-Seung;Kim, Su-Geun;Shin, Min-Yong;Kim, Seung-Chul;Lee, Tea-hun;An, Sung-Hyeun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.2
    • /
    • pp.79-83
    • /
    • 2018
  • Purpose $^{18}F-FDG$, which is commonly used in PET-CT examinations, is low in capacity and it is difficult to keep the amount of radioactivity busy when the specific activity is high, increasing the amount of space dose and radioactive contamination in the distribution room. Therefore, while evaluating the actual dose administered to patients during the manual dispense process, the medical institution intends to assess the usefulness of the auto dispenser by comparing the differences from the actual dose administered to the patient using the new automatic dispense. Materials and Methods From July 2016 to December 2016, 846 patients were manually administered by workers using $^{18}F-FDG$ and $^{18}F-FDG$ 906 patients were using auto dispenser from July 2017 to December 2017. Results Capacity administered to patients during the manual dispense averaged $35.41{\pm}27.79%$ compared to the recommended dose, and the auto dispenser process showed a small difference of $-2.15{\pm}3.99%$ compared to the recommended dose(p<0.05). Conclusion Working people did not have to touch radioactive medicines directly while they were busy in the auto dispenser, and because of the availability of other tasks far away, the time and distance to receive the exposure were also advantageous. It is believed that future use by many medical institutions will not only reduce the dose to patients but also help reduce the exposure dose to workers.

Comparison and Review of GBEF% on the Anterior and Right Lateral Images of Nuclear Hepatobiliary Scan (핵의학 간담도 스캔 시, 전면상과 우측 측면상에서의 담낭박출률에 대한 비교 및 고찰)

  • Lee, Eun-Byeol;Kim, Jae-Il;Do, Yong-Ho;Llm, Jung-Jin;Cho, Sung-Wook;Noh, Gyeong-Woon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.2
    • /
    • pp.92-96
    • /
    • 2018
  • Purpose In case of nuclear medical hepatobiliary scan, To quantitatively evaluate contractility of a gallbladder, gallbladder ejection fraction (GBEF%) is calculated from anterior images using fatty meal. However, when a gallbladder and other organs overlap on an anterior image, the gallbladder ejection fraction is not accurately evaluated. In order to reduce this error, the objective of our study was to figure out whether there is a significant difference in GBEF% calculated from the anterior and right lateral images. Materials and Methods After intravenous injection of 99mTc-Mebrofenin 370 MBq to randomly 50 patients who visited our hospital, we started to examine nuclear hepatobiliary scan. Using skylight(Philips, United States), we acquired anterior and right lateral image at 10 minutes, 20 minutes, 30 minutes, 60 minutes, 90minutes after injection. Using images at 60 and 90 minutes, gallbladder ejection fraction (GBEF%) was calculated from the anterior and right lateral images using JETstream workspace. For drawing more accurate ROI, CT images were referenced and 4 radiologists calculated the GBEF% in the same image and calculated the average value. We assessed whether there was a significant difference in GBEF% calculated from the anterior and right lateral images using SPSS program(Statistical Package for the Social Science, SPSS Ver.18 Inc. USA). Results About randomly 50 patients, the average value of the GBEF% calculated from the anterior image was 63.212 and the average value of the GBEF% calculated from the right lateral image was 62.666. GBEF% decreased 0.433% on the right lateral image compared with anterior image. Result of paired sample t-test, p value is over 0.05. So, there was no significant difference in GBEF% calculated from the anterior and right lateral images. Conclusion In the case that a gallbladder and other organs are not separated on an anteior image, Right lateral image would be better to acquire more accurate GBEF% than using anterior image.

Effect of Gaseous Chlorine Dioxide on Sterilization in Industrial Food-holding Cabinets (이산화염소가스를 이용한 식품산업용 소독장에서의 살균효과)

  • Kim, Hyeon Jeong;Shin, Jiyoung;Kim, Ji-eun;Yang, Ji-young
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.2
    • /
    • pp.170-177
    • /
    • 2019
  • The aim of this study was to investigate the effect of different concentrations of chlorine dioxide ($ClO_2$) on sterilization and deodorization of food-holding cabinets under different exposure times. For the measuring sterilization and deodorization, a 6.5 L chamber and a 625 L cabinet with circulation systems were used. Two bacteria (Staphylococcus aureus KCTC1916 and Escherichia coli KCTC 1682) that were artificially inoculated in the plate respectively were put into the 6.5 L chamber and the 625 L cabinet. The $ClO_2$ gas was produced by ampules. In the 6.5 L chamber, neither of the two bacteria was detected after 24 hours treatment by $ClO_2$ gas. Moreover, the deodorization rate against ammonia and phenol was 94% and 70%, respectively, but deodorization against formaldehyde was not effective. When the concentration reached maximum (6 ampule, 4.6 ppm) levels in the cabinet, it lasted for approximately 2 h and then decreased slowly. When a circulator was used, the gas concentration was very low (6 ampule, 0.8 ppm) and the antibacterial activity against S. aureus and E. coli was low. The level of reduction against S. aureus and E. coli was 2.98 log CFU/plate and 6.06 log CFU/plate, respectively, in the cabinet after 24 h without a circulator. The reduction against S. aureus KCTC1916 and E. coli KCTC1682 was 2.69 log CFU/plate and 4.41 log CFU/plate for 24 h, respectively.

Dissipation of Bifenthrin and Chlorothalonil in Crown Daisy during Cultivation and their Biological Half-lives (쑥갓 중 bifenthrin과 chlorothalonil의 경시적 잔류량 변화 및 생물학적 반감기)

  • Kang, Min-Seong;Park, Po-Hyun;Kim, Ki-Yu;Lim, Bu-Geon;Ryu, Kyong-Shin;Lee, You-Jin;Lim, Jeong-Hwa;Kang, Choong-Won;Kim, Youn-Ho;Lee, Sun-Young;Seo, Jeong-Hwa;Park, Yong-Bae;Yoon, Mi-Hye
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.2
    • /
    • pp.191-198
    • /
    • 2019
  • This study investigated the residual characteristics of bifenthrin and chlorothalonil in crown daisy and suggested pre-harvest residue limits (PHRLs) based on their dissipation patterns and biological half-lives. The samples for residue analysis were harvested at 0 (3 hr), 1, 3, 5, 7, 9, 11, 13, 15, 18, 22 and 26 days after treatment, and analyzed by $GC/{\mu}-ECD$ and TOF/MS. The limit of quantitation (LOQs) of bifenthrin and chlorothalonil were 0.0046 mg/kg and 0.0007 mg/kg, respectively. Recoveries ranged from $88.67{\pm}7.97%$ and $99.90{\pm}16.03%$, showing that this method is appropriate for the analysis of the pesticide residues in crown daisy. Being well within first order kinetics, the biological half-lives of the pesticide residues in crown daisy were 9.63 days for bifenthrin and 6.54 days for chlorothalonil. The PHRLs of bifenthrin and chlorothalonil were recommended as 11.70 mg/kg and 24.10 mg/kg for 26 days before harvest, respectively.

Effects of Wind Net Shading and Sprinkling on Growing Conditions and Fruit Quality in 'Hongro' and 'Fuji' Apple Fruits (방풍망 차광시설 및 미세살수 처리가 '홍로' 및 '후지' 사과나무의 생육환경 및 과실 품질에 미치는 영향)

  • Kang, Kyeong-Jin;Seo, Jeong-Hak;Yoon, Hong-Ki;Seo, Jeong-Seok;Choi, Taek-Yong;Chun, Jong-Pil
    • Journal of Bio-Environment Control
    • /
    • v.28 no.2
    • /
    • pp.126-133
    • /
    • 2019
  • In recent years, the deterioration of fruit quality caused by poor coloration and sunburn disorder has become serious problems in apple market, which is a result of the increase of surface temperature due to the abnormal temperature increase during summer season. This study was conducted to investigate the effect of wind net shading and fine water spray using sprinkler on fruit coloration, sunburn damage and overall fruit quality of 'Fuji' and 'Hongro' apples. Fifteen sprinklers (7L/hr) were installed at the orchard of the Chungcheongnam-do Agricultural Research and Extension Services, located in Sinam-myeon Chungcheongnam-do Korea, at a height of 3m above the apple tree of $1.5m{\times}3.5m$ north-south direction. Fine water spraying treatment was divided into day time spray (10:00 am to 6:00 pm) and all day spray (10:00 am to 10:00 pm) from early July to 10 days before harvest in 2017 and 2018 season, respectively. Temperature of the surface of apple fruit, characteristic of fruit, and degree of sunburn damage were investigated. In 'Fuji', the fruit surface temperature checked at 2 pm on August 10 was decreased considerably in the day time spray ($35.6^{\circ}C$) and wind net ($39.0^{\circ}C$) when compared with the untreated control ($44.4^{\circ}C$). Similarly, the fruit surface temperature also decreased considerably in the all day spray ($35.1^{\circ}C$) and wind net ($36.9^{\circ}C$) treatments when compared with the untreated control ($46.5^{\circ}C$) in 'Hongro' apples. The incidence of sunburn disorder was significantly decreased with day time spray (5.0%), all day spray (5.8%) and wind net (7.0%) when compared with untreated control (23.4%) in 'Fuji' apples. As a results, the treatment of fine water spray and wind net consequently showed 26% and 34% increase of redness ($a^*$) value in the skin color difference, respectively, in 'Fuji' apples.

Glomerular Filtration Rate Test Methods and Guidelines (Glomerular Filtration Rate 검사방법 및 가이드라인)

  • Park, Min-Ho;Lee, Ha-Young;Ryu, Hwa-Jin;Yoo, Tae-Min;Noh, Gyeong-Woon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.2
    • /
    • pp.97-100
    • /
    • 2018
  • Purpose The glomerular filtration rate (GFR) test is an important indicator of glomerular filtration and has been used to test renal function and the extent of its function. The GFR test is performed by intravenous injection of radioactive medicines made of $^{51}Cr$-EDTA, and blood concentration is measured by taking blood according to the elapsed time. also, PET-CT, bone scan, transfusion and so on will affect the outcome. Therefore, we will improve the quality of the test by providing guidelines for the GFR test for more accurate testing. Materials and Methods 5 mL of physiological saline solution and 2 mL of $^{51}Cr$-EDTA solution are used to make 5 mL of the radiopharmaceutical solution to be injected into the patient. First, the syringe weight is measured before the injection, and then the radioactive medicine is injected into the patient's vein and the syringe weight is measured after the injection. Blood sampling is performed twice in total. In adults, blood is collected 3 hours / 5 hours after injection and in children 2 hours / 5 hours after injection. The blood sample is centrifuged at 3300 rpm for 5 minutes. Standard solution is prepared by filling diluent water up to the scale indicated in the 200-mL volumetric flask, discarding $500{\mu}L$, injecting $500{\mu}L$ of GFR reagent and mixing well. $500{\mu}L$ each of the standard solution is dispensed into two test tubes, and $500{\mu}L$ of each of the plasma samples collected in time is dispensed into two test tubes and measured with a Cobra Counter. Results At present, the reference range applied in this study is $119.5{\pm}30.3ml/min/1.73m2$ for males and $125.2{\pm}28.2ml/min/1.73m^2$ for females. Conclusion The GFR test is conducted using radioactive medical products. GFR testing is performed as a scheduled test, but PET-CT, dialysis and transfusion, which may affect GFR testing, may be scheduled during GFR testing. Therefore, we could get accurate GFR test results by notifying the ward and department beforehand when booking.

Consideration of a Bacteria Contamination Management in the Dispensation of 99mTc Radiopharmaceutical (테크네슘 방사성의약품의 조제와 분배 과정에서 오염균에 대한 고찰)

  • Choi, Do Chul;Gim, Yeong Su;Jo, Gwang Mo;Gim, Hui Jeong;Seo, Han Gyeong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.2
    • /
    • pp.84-87
    • /
    • 2018
  • Purpose The radiopharmaceutical used in the nuclear medicine department is used only for the specific patient according to the prescription or instruction of the doctor without selling, so it is dispensed and it is distributed and used for the examination. Radiopharmaceuticals administered to patients should be managed appropriately as well as radiation safety management during dispensation. The purpose of this study is to investigate microbial contamination during dispensation of radiopharmaceuticals Materials and Methods This study distinguished between general workbench and clean workbench and performed three tests. First, microbial cultivation test of radiopharmaceutical prepared and dispensed in general workbenches and sterile workbenches were carried out five times, respectively. The second test was performed settle plate method three times before and after the use of the exhaust filter. Finally, Adenosine Triphosphate (ATP) measurement was performed in each workbench to measure bacterial counts. In addition, ATP measurement were carried out by designating locations and items that may be contaminated during dispensation. Results In the microbial culture test, no microorganisms were detected in both samples. In the settle plate method, it was detected without using of the exhaust filter in a general workbench once. In the ATP measurement test, it was measured at the level of 400 RLU or less, which is the standard value of contamination, in both workbenches surface. In additional ATP measurement test, the refrigerator handle in the distribution room was measured above the reference value of 1217 RLU, the vacuum vial shield of the Tech Generator at 435 RLU, and the syringe holder at 1357 RLU. After environmental disinfection, the results were reduced to 311 RLU, 136 RLU, and 291 RLU. Conclusion No contamination by bacteria was found in both workbenches. However, microbial contamination may occur if the use of an exhaust filter or proper hand hygiene is not achieved. Regular inspections and management for aseptic processing themselves will be necessary.

'Samkwang1', a Medium Maturing, Multiple Disease Resistant, and High-quality Rice (중생 복합내병성 고품질 벼 '삼광1호')

  • Lee, Jeong-Heui;Won, Yong-Jae;Cho, Young-Chan;Lee, Jeom-Ho;Yang, Chang-Ihn;Kim, Myeong-Ki;Ahn, Eok-Keun;Suh, Jung-Pil;Lee, Sang-Bok;Jeon, Yong-Hee;Sung, Yeol-Kyu;Jeong, Eung-Gi;Ha, Woon-Goo;Chang, Jae-Ki;Jung, Kuk-Hyun;Yoon, Mi-Ra;Kang, Kyeong-Ho;park, Hyang-Mi;Roh, Jae-Hwan;Kim, Bo-Kyeong
    • Korean Journal of Breeding Science
    • /
    • v.50 no.4
    • /
    • pp.490-496
    • /
    • 2018
  • "Samkwang1," a japonica rice variety, was developed as a cross between "Samkwang" and F1 of Suwon152 (IT008283), which has a medium maturing and lodging resistance and Samkwang (IT284608), a high quality variety with bacterial blight resistance and mid-late maturing property by the rice breeding team at NICS in 2015. The heading date of "Samkwang1" was August 8 in the middle plain area, which was 2 days early than that of "Hwaseong." "Samkwang1" had a culm length of 77 cm, which was 7 cm shorter than that of "Hwaseong," and it had 128 spikelets per panicle. The viviparous germination rate of "Samkwang1" was 2.1%. "Samkwang1" showed resistance to blast, bacterial blight (K1, K2, and K3 race) and stripe virus, but was susceptible to the K3a race of bacterial blight, dwarf and black streak dwarf viruses, and plant hoppers. The milled rice of this variety exhibits translucent and medium short grains. The cooked rice grains of "Samkwang1" have an excellent palatability index (0.35) and lower protein content (6.2%) than that of "Hwaseong." The characteristics related to grain milling were better than those of "Hwaseong," especially the head rice milling recovery ratio and head rice ratio (94.2%). "Samkwang1" showed 5.62 MT/ha of milled rice productivity at 11 sites under ordinary cultivation conditions (Registration No. 6798).

Characteristics of New Ever-bearing Strawberry 'Bokha' Bred for Tropical and Subtropical zone Cultivation (열대 및 아열대 지역 재배용 사계성 딸기 '복하' 육성)

  • Lee, Jong Nam;Kim, Hye Jin;Choi, Mi Ja;Suh, Jong Taek;Nam, Jung Hwan;Hong, Su Young;Kim, Su Jeong;Shon, Hwang Bae;Kim, Ki Deog;Kim, Yul Ho
    • Journal of the Korean Society of International Agriculture
    • /
    • v.30 no.4
    • /
    • pp.300-304
    • /
    • 2018
  • 'Bokha' is a new strawberry (Fragaria x ananassa Duch.) cultivar, which was released by the Highland Agriculture Research Institute in 2016. The 'Bokha' cultivar originated from a cross between 'Goha' and 'Saebong No. 3' that showed excellent ever-bearing characteristics, including continuous flowering habit and high soluble-solids contents under long-day and high temperature conditions in 2011. This cultivar was initially named 'Saebong No. 8' after examining its characteristics and productivity in summer culture from 2013 to 2015. After regional adaptability tests in 2016, 'Bokha' was selected from Saebong No. 8 as an elite cultivar. The general characteristics of 'Bokha' include semispreading type, elliptical leaves, and moderately vigorous growth. The fruits are conical in shape, and red in color. 'Bokha' plants have 32.7 leaves, 9.9 more than 'Goha' plants. The soluble-solids content of 'Bokha' was 9.2%, which was 0.2% higher than that of 'Goha'. The average fruit weight of 'Bokha' was about 9.5g and the marketable yield was $27,701kg{\cdot}ha^{-1}$, 72% higher than 'Goha'. 'Bokha' is suitable for tropical and subtropical zone cultivation as a high soluble solids contents cultivar, because it shows continuous flowering habit under long-day and high temperature conditions.

A Study on the Possibility of Recycling Coir Organic Substrates for using Strawberry Hydroponics Media (토마토 폐배지를 딸기 수경재배 배지로 재이용 가능성 연구)

  • Lee, Gyu-Bin;Park, Young-Hoon;Choi, Young-Whan;Son, Beung-Gu;Kim, Jooh-Yup;Kang, Nam-Jun;Kang, Jum-Soon
    • Journal of Korea Society of Waste Management
    • /
    • v.34 no.2
    • /
    • pp.205-213
    • /
    • 2017
  • The current study was performed to investigate the effect of recycling coir substrates on the growth, fruit yield, and quality of strawberry plants. Analysis of physical properties revealed that the pH of a fresh coir substrate was 5.04 while those of substrates reused for one and two years were 5.20 and 5.33, respectively. The electrical conductivity (EC) of a new substrate was as high as $4.58dS{\cdot}m^{-1}$. This can cause salt stress after transplanting. The EC tended to decrease as the substrate was recycled, and the EC of a two-year recycled substrate was $1.48dS{\cdot}m^{-1}$. The fresh substrate had lower nitrogen and calcium concentrations, but higher phosphate, potassium, and sodium concentrations than the recycled coir substrate. The coir substrates recycled for one or two years maintained better chemical properties for plant growth than the fresh substrate. Strawberry growth varied depending on the number of years that the coir substrate was recycled. In general, strawberries grown in substrates that had been reused for two years did better than those grown in substrates that had been reused once or were fresh. Ninety days after transplanting, a plant grown in a substrate that had been reused for two years contained 25 leaves, which was 3.6 more than with a fresh substrate. In addition, the plants grown in a substrate that had been reused for two years exhibited larger leaf areas than those grown in other substrates. Coir substrates that had been reused for one year increased the number and area of leaves, but not as much as the substrate that had been reused for two years. One- and two-year reused coir substrates increased the weight of strawberries produced relative to the unused substrate, but the difference was not statistically significant. The plants grown in two-year reused substrates were longer and wider, as well. Also, the number of fruits per plant was higher when substrates were reused. Specifically, the number of fruits per plant was 28.7 with a two-year reused substrate, but only 22.2 with a fresh substrate. The fruit color indices (as represented by their Hunter L, a, b values) were not considerably affected by recycling of the coir substrate. The Hunter L value, which indicates the brightness of the fruit, did not change significantly when the substrate was recycled. Neither Hunter a (red) nor b (yellow) values were changed by recycling. In addition, there were no significant changes in the hardnesses, acidities, or soluble solid-acid ratios of fruits grown in recycled substrates. Thus, it is thought that recycling the coir substrate does not affect measures of fruit quality such as color, hardness, and sugar content. Overall, reuse of coir substrates from hydroponic culture as high-bed strawberry growth substrates would solve the problems of new substrate costs and the disposal of substrates that had been used once.