• Title/Summary/Keyword: 2-unit

Search Result 13,905, Processing Time 0.065 seconds

Evaluation on the Marginal Fitness of Zirconia Core fabricated with CAD/CAM System (CAD/CAM 시스템으로 제작한 지로코니아 코어의 변연 적합도 평가)

  • Noh, Hyeongrok;Sun, Gumju;Joo, Kyuji
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.11
    • /
    • pp.800-806
    • /
    • 2013
  • The purpose of this study was to evaluate the marginal fitnesses on the effect of span length of bridge and the marginal gaps within the clinically allowed range. The samples were fabricated with zirconia core using CAD/CAM system. The test groups were divided by four groups, single crown, 2-units bridge, 3-units bridge and 4-units bridge and 10 zirconia cores per each group. The results of mean marginal gaps were $42.95{\pm}6.93{\mu}m$ in the single crown, $43.53{\pm}5.27{\mu}m$ in 2-unit, $53.43{\pm}13.38{\mu}m$ in 3-unit, and $50.85{\pm}8.25{\mu}m$ in 4-unit on each. The marginal gap of mesial and distal surfaces were statistically significant differences between single, 2-unit group and 3-unit, 4-unit group (p<.05) and this results was effected by the span length. The buccal and lingual surfaces were no statistically significant differences within all groups(p>.05). From this results the span length of the zirconia core may have influence on marginal fitness and the marginal gaps were within the clinically allowed range.

Normal MR Spectroscopic Findings of the Cerebellum and Pons: Comparison of the Results between Intra-Unit and Inter-Unit Studies (소뇌와 뇌교의 정상 자기공명분광 소견: 같은 장비내 및 다른 장비간의 결과 비교)

  • 최준일;장기현;송인찬;도강현;이준우
    • Investigative Magnetic Resonance Imaging
    • /
    • v.5 no.2
    • /
    • pp.123-129
    • /
    • 2001
  • Purpose: The purposes of this study are to evaluate normal MR spectroscopy (MRS) data of the cerebellum and pons, and to evaluate intra-unit and inter-unit differences of the results. Materials and methods: Nine normal volunteers (mean age 23 years) were studied with two 1.5 Tesla MR units (A and B units). A total of four sessions of MRS study were performed with two sessions in ea.ch MR unit in each volunteer. In each session, MRS data were obtained from bilateral cerebellar hemisphere and pons. MRS was performed using spin-echo single voxel technique with repetition time of 2000 ms, echo time of 288ms and 128 averagings. Voxel size was $2{\;}{\times}{\;}2{\;}{\times}{\;}1.5{\;}cm$ in the cerebellum and $1.5{\;}{\times}{\;}1.5{\;}{\times}{\;}1.5{\;}cm$ in the pons. Metabolite ratios of NAA/Cho, NAAcCr, NAAc(Cho+Cr) and Cr/Cho (both peak heights and the peak areas) were compared among the results of four sessions of MRS for evaluation of intra-unit and inter-unit differences. Results: In the cerebellum, mean (SO values of peak height NAA/Cho, NAA/Cr, NAA/(Cho+Cr) and Cr/Cho ratios obtained in the first session of A unit were $1.08{\pm}O.16,{\;}1.44{\pm}O.286,{\;}0.61{\pm}O.09{\;}and{\;}O.76{\pm}0.13$, respectively. Comparing with the results of the second session, intra-unit differences were 3-7%. In B unit intra-unit differences were 1-9%, except for 22% of Cr/Cho ratio. Inter-unit differences between A and B units were 1-26%. In the pons, mean ISD values of peak height NANCho, NANCr, NANICho + Cr) and Cr/Cho ratios obtained in the first session of A unit were $1.51{\pm}O.35,{\;}3.35{\pm}O.78,{\;}1.02{\pm}0.16{\;}and{\;}0.47{\pm}O.14$, respectively. Mean NAAfCho, NANCr and NAAI(Cho+ Cr} ratios of the pons were significantly higher than those of the cerebellum. Intra-unit differences were 2-21 % in A unit and 4-18 % in B unit. Inter-unit differences between A and B units were 1-18%. The mean values obtained by using peak area were generally higher and wider in range than those of peak height in both units. Conclusion: Mean NAAfCho, NAAlCr and NAAf(Cho+Cr) ratios of the cerebellum were significanHy lower than those of the pons. Intra-unit differences of most metabolites ratios were generally not significant, whereas inter-unit differences were greater than intra-unit differences in more metabolite ratios. Therefore, normal MRS data of the cerebellum and the pons should be obtained in every MR unit, before MRS applications in the diseases of the cerebellum and the pons.

  • PDF

COMPARISON OF LINEAR POLYMERIZATION SHRINKAGE IN COMPOSITES AND COMPOMER POLYMERIZED BY PLASMA ARC OR CONVENTIONAL VISIBLE LIGHT CURING (리노미터를 이용한 할로겐 가시광선 광조사기와 플라즈마 아크 광조사기의 복합레진 및 컴포머의 광중합 양상 비교)

  • Lee, Jae-Ik;Park, Sung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.5
    • /
    • pp.488-492
    • /
    • 2002
  • The purpose of this study was to evaluate the effectiveness of plasma arc curing (PAC) unit for composite and compomer curing. To compare its effectiveness with conventional quartz tungsten halogen (QTH) light curing unit, the polymerization shrinkage rates and amounts of three composites (Z100, Z250, Synergy Duo Shade) and one compomer, that had been light cured by PAC unit or QTH unit, was compared using a custome made linometer. The measurement of polymerization shrinkage was peformed after polymerization with either QTH unit or PAC unit. In case of curing with the PAC unit, the composite was light cured with Apollo 95E for 6s, the power density of which was recorded as 1350 mW/$\textrm{cm}^2$ by Coltolux Light Meter. For light curing with QTH unit, the composite was light cured for 30s with the XL2500, the power density of which was recorded as 800 mW/$\textrm{cm}^2$ by Coltolux Light Meter. The amount of linear polymerization shrinkage was recorded in the computer every 0.5s for 60s. Ten measurements were made for each material. The amount of linear polymerization shrinkage for each material in 10s and 60s which were cured with PAC or QTH unit were compared with t test. The amount of polymerization shrinkage in the tested materials were compared with 1way ANOVA with Duncan's multiple range test. As for the amounts of polymerization shrinkage in 60s, there was no difference between PAC unit and QTH unit in Z250 and Synergy Duo Shade. In Z100 and Dyract AP, it was lower when it was cured with PAC unit than when it was cured with QTH unit (p<0.05). As for the amounts of polymerization shrinkage in 10s, there was no difference between PAC unit and QTH unit in Z100 and Dyract AP. The amounts of polymerization shrinkage was significantly higher when it was cured with PAC unit in Z250 and Synergy Duo Shade (p<0.05). The amounts of polymerization shrinkage in the tested materials when they were cured with QTH unit were Z250 (6.6um) < Z100 (9.3um), Dyract AP (9.7um) < Synergy Duo Shade (11.2um) (p<0.05). The amount of polymerization shrinkage when the materials were cured with PAC unit were Dyract AP (5.6um) < Z100 (8.1um), Z250(7.0um) < Synergy Duo Shade (11.2um) (p<0.05).

Development of a robust bench-scale testing unit for low-pressure membranes used in water treatment

  • Huang, Haiou;Schwab, Kellogg;Jacangelo, Joseph G.
    • Membrane and Water Treatment
    • /
    • v.2 no.2
    • /
    • pp.121-136
    • /
    • 2011
  • A bench-scale test has recently been proposed as a predictive tool to minimize the scope of pilot-scale testing or to optimize the operation of full-scale membrane filtration systems. Consequently, a bench-scale testing unit was developed for this purpose and systematically evaluated in this study. This unit was capable of accommodating commercially available, low pressure, hollow fiber (LPHF) membranes with various configurations for testing under conditions comparable to real-world applications. Reproducibility of this unit in assessing membrane fouling and microbial removal efficiency of LPHF membranes was tested and statistically comparable results were obtained. This unit serves as a useful apparatus for academic researchers and utilities to evaluate the performance of LPHF membranes used for water treatment.

The Study on the Developing Process of BIM Modeling for Urban-life-housing Based on Unit Modular (유닛모듈러 기반 도시형 생활주택의 BIM 모델링 프로세스 개발 연구)

  • Lee, Chang-Jae;Lim, Seok-Ho
    • KIEAE Journal
    • /
    • v.12 no.6
    • /
    • pp.77-84
    • /
    • 2012
  • The current architectural design of unit modular has been based on 2D of CAD program, so unit modular character which needs unit information management, as a dried-member system, has no effect on design process. The purpose of this study is We have developed a suitable BIM design process, according to various works of construction, then tried to contribute to supply and activation of the urban-life-housing based on unit modular. The BIM modeling process based on unit modular has been in order of unit combination with preparing manual classification, and, it has been constructed, at construction site, from housing foundation to roof finish by Bottom-up method. At a manufacturing factory, it has been produced in order of 1) grouping materials and parts, 2) fabricating unit boxes, and 3) interference examination of unit boxes, and each order has been classified as housing structure, architecture, plumbing process separately. At a construction site, the fabrication has been done in order of, like as a real housing construction scenario, 1) RC foundation work 2) unit module job-site-fabrication work, 3) roof truss work, 4) plumbing and HVAC work, and 5) housing interior finish work. After modeling process, the interference examination on each work of construction has finally completed modeling. The Unit modular utilizing BIM modeling can make easy housing maintenance through systematic control with preparing manual of unit module information, and securing accurate and speedy construction information. And it will promote design credibility and create maximum effect of unit modular construction method, such as construction period reduction and upgrade of construction quality, etc., through the computer simulation as real as construction environment in cyber space, and with the interfering examination.

A Study on the Cooling Load of South and East Facing Apartment Houses (남향과 동향 집합주택의 냉방부하에 관한 연구)

  • 박근우;이경희
    • Journal of the Korean housing association
    • /
    • v.11 no.2
    • /
    • pp.129-137
    • /
    • 2000
  • This study is about the difference of South and East facing Cooling load of Apartment s Houses using Dynamic Heat-flow Calculation. Therefore, the purpose of this study is come in to use Material for the Thermal Environments of Apartment Houses. The results of the analysis are below. (1) For the peak load of degree hour; The highest is "I" unit and the next high load is H, F, E, C, B, G, D and A unit for the south facing Apartment houses. The higher load is "H" unit and the next high load is I, E, F, B, C, G, D, A Unit for the east facing Apartment houses. (2) For the total load of degree day; The highest load is "I" unit and the next high load is H, G, F, E, C, B, D and A Unit for the south facing Apartment houses. The highest load is "H" unit and the next high load is I, G, E, F, B, C, D, A Unit for the east facing Apartment houses. (3) For the total load of degree day; The highest load is "H" Unit for the east facing Apartment houses and the Lowest load is "A" Unit for the south facing Apartment houses.is "A" Unit for the south facing Apartment houses.nt houses.

  • PDF

Fabrication Characteristics and Performance Evaluation of a Large Unit Cell for Solid Oxide Fuel Cell (고체산화물연료전지용 대면적 단위전지 제조특성 및 성능평가)

  • Shin, Y.C.;Kim, Y.M.;Oh, I.H.;Kim, H.S.;Lee, M.S.;Hyun, S.H.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.13-16
    • /
    • 2008
  • Solid oxide fuel cell(SOFC) is an electrochemical energy conversion system with high efficiency and low-emission of pollution. In order to reduce the operating temperature of SOFC system under $800^{\circ}C$, the thickness reduction of YSZ electrolyte to be as thin as possible, e.g., less than 10 ${\mu}m$ are considered with the microstructure control and optimum design of unit cell. Methods for reducing the thickness of YSZ electrolyte have been investigated in coin cell. Moreover, a large unit cell($8cm{\times}8cm$) for SOFC was fabricated using an anode-supported electrolyte assembly with a thinner electrolyte layer, which was prepared by a tape casting method with a co-sintering technique. we studied the design factors such as active layer, electrolyte thickness, cathode composition, etc,. by the coin type of unit cell ahead of the fabrication process of a large unit cell and also reviewed about the evaluation technique of a large size unit cell such as interconnect design, sealing materials and current collector and so forth. Electrochemical evaluations of the unit cells, including measurements such as power density and impedance, were performed and analyzed. Maximum power density and polarization impedance of coin cell were 0.34W/$cm^2$ and $0.45{\Omega}cm^2$ at $800^{\circ}C$, respectively. However, Maxium power density of a large unit cell($5cm{\times}5cm$) decreased to 0.21W/$cm^2$ at $800^{\circ}C$ due to the increase of ohmic resistance. However, It was found that the potential value of a large unit cell loaded by 0.22A/$cm^2$ showed 0.76V at 100hrs without the degradation of unit cell.

  • PDF

A Study on Unit Model Development of Urban Type Silver Housing Applying Open Housing Concept -In Response to the kinds and process of diabetes elders- (오픈 하우징 개념을 적용한 도시형 노인 공동주거시설의 주호 모형 개발에 관한 연구 -당뇨병 노인의 질병 종류와 진행에 대응하여-)

  • Lee, Bo-Ram;Yoon, Chae-Shin
    • Journal of the Korean housing association
    • /
    • v.18 no.5
    • /
    • pp.11-22
    • /
    • 2007
  • The purpose of this study is to propose prototypical plans for a dwelling unit applying the concepts of 'open housing' and 'aging in place' for senior citizens living in cities focusing on specific life patterns with chronic disease. Especially, a unit was designed for diabetes patients because diabetes, a representative disease of elderly people, often accompanies complications such as arthritis and Alzheimer disease. A unit design suitable for the convenient life of the elderly people with diabetes will provide a guideline for the similar unit designs of the senior citizens with other diseases. In this study, three types of unit plan are proposed. A-type plan is for type-1 diabetes patients, B-type alt.1 for the independent seniors of type-2 diabetes patients, and B-type alt.2 for the dependant seniors of type-2 diabetes patients. And a support design for a unit plan with the exclusive area of $60\;m^2$ is proposed. The same support design is used for all three unit types. Although the locations of bathroom and storage room are fixed and the location of the kitchen is changeable only in wet-zone. In conclusion, senior residents with diabetes can choose one of three unit types before occupation and the chosen unit type can be renovated by replacing infill systems as the health condition or life style changes.

The Study of Complex RF Unit in WiBro Base Station for Wave 2 Standard (Wave 2 규격을 위한 와이브로 기지국용 일체형 복합 RF unit 연구)

  • Choi, DooHun;Moon, Yon-Tae;Kim, Do-Gyun;Choi, Young-Wan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.9
    • /
    • pp.1660-1668
    • /
    • 2008
  • The WiBro was adopted to the 3G international standard. By the change of specification from Wave 1 to Wave 2, MIMO technology is applied in order to increase the speed of downlink. By MIMO the RF part of WiBro base station is increased to 2 Tx paths. Therefore, the size of RF part is bigger and material cost is increased. For reducing these demerits, the RF part which is consisted of PA, LNA, and TDD switch is designed to one complex RF unit. Also, the experimental results of the RF unit have been discussed. Since the complex RF unit is more compact than the RF part of Wave 1 base station, it can be used as the RF part of Wave 2 base station with 2T/2R MIMO.