• Title/Summary/Keyword: 2-flex

Search Result 218, Processing Time 0.022 seconds

FPGA Implementation of the AES Cipher Algorithm by using Pipelining (파이프라이닝을 이용한 AES 암호화 알고리즘의 FPGA 구현)

  • 김방현;김태규;김종현
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.8 no.6
    • /
    • pp.717-726
    • /
    • 2002
  • In this study, we analyze hardware implementation schemes of the ARS(Advanced Encryption Standard-128) algorithm that has recently been selected as the standard cypher algorithm by NIST(National Institute of Standards and Technology) . The implementation schemes include the basic architecture, loop unrolling, inner-round pipelining, outer-round pipelining and resource sharing of the S-box. We used MaxPlus2 9.64 for VHDL design and simulations and FLEX10KE-family FPGAs produced by Altera Corp. for implementations. According to the results, the four-stage inner-round pipelining scheme shows the best performance vs. cost ratio, whereas the loop unrolling scheme shows the worst.

A Study on an Application of HyFlex Learning Model for Early Childhood Education in the PostCOVID-19 era (PostCOVID-19 시대 유아교육을 위한 HyFlex 수업모형의 적용 가능성 탐색)

  • Kim, Sun-Hee
    • Journal of Digital Convergence
    • /
    • v.19 no.12
    • /
    • pp.311-320
    • /
    • 2021
  • This study aims to explore the applicability of the HyFlex Learning Model as a new form of early childhood education in the post-COVID-19 era. In order to achieve the purpose of this study, first, the current challenges of early childhood education and the form of early childhood distance education in Korea were examined. Second, after examining the outline and characteristics of the HyFlex Learning Model(HLM) and the application cases of overseas institutions, in particular, the cases of applying the HLM in overseas early childhood education institutions were reviewed. Third, things to consider when applying the HLM in the field of early childhood education in Korea were derived. As a result, the HLM was investigated to be applicable not only in higher education but also in early childhood education as a model that emphasizes the learner's choice, learner-centered/directed, and activity. In order to apply the HLM to the early childhood education field in Korea, several points to be considered were proposed. Finally, the contribution of this study and further study were suggested.

Production of Flavonoid Compounds and Anti-inflammatory Property of Fermented Licorice Extract with the Basidiomycete Grifola frondosa HB0071 (잎새버섯 균사체를 이용한 감초추출발효물의 플라보노이드 생성과 항염 활성 연구)

  • Bae, Jun Tae;Song, Min Hyeon;Kim, Jin Hwa;Lee, Geun Soo;Pyo, Hyeong Bae
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.38 no.4
    • /
    • pp.327-338
    • /
    • 2012
  • Liquiritigenin and isoliquiritigenin are the major flavonoids present in licorice. These flavonoid compounds were prepared by submerged culture of Grifola frondosa (G. frondosa) HB0071 mycelia producing ${\beta}$-glucosidase in the aqueous extract of licorice. The contents of liquiritigenin and isoliquiritigenin were increased during the fermentation. This fungus produced a high ${\beta}$-glucosidase (activity of 91.5 mU/mL), thereby achieving high amounts of liquiritigenin and isoliquiritigenin ($568.5{\mu}g/mL$ and $89.6{\mu}g/mL$), respectively at 96 h. A reversed- phase high-performance liquid chromatography method was established for simultaneous determination of liquiritigenin and isoliquiritigenin in fermented licorice extract (FLEx). The anti-inflammatory activities were investigated by licorice extract (LEx) before and after fermentation with G. frondosa HB0071. The treatment of UVB-irradiated HaCaT keratinocytes with FLEx resulted in a dose-dependent decrease in the expression level of cyclooxygenase-2 (COX-2) mRNA. Furthermore, FLEx dose-dependently decreased mRNA of the pro-inflammatory cytokines of IL-$1{\beta}$ and IL-6 in UVB-irradiated HaCaT cells. These results suggest that FLEx may mitigate the effects of skin inflammation by reducing UVB-induced adverse skin reactions.

Anatomy of Spleen Meridian Muscle in human (족태음비경근(足太陰脾經筋)의 해부학적(解剖學的) 고찰(考察))

  • Park Kyoung-Sik
    • Korean Journal of Acupuncture
    • /
    • v.20 no.4
    • /
    • pp.65-75
    • /
    • 2003
  • This study was carried to identify the component of Spleen Meridian Muscle in human, dividing into outer, middle, and inner part. Lower extremity and trunk were opened widely to demonstrate muscles, nerve, blood vessels and the others, displaying the inner structure of Spleen Meridian Muscle. We obtained the results as follows; 1. Spleen Meridian Muscle is composed of the muscle, nerve and blood vessels. 2. In human anatomy, it is present the difference between a term of nerve or blood vessels which control the muscle of Meridian Muscle and those which pass near by Meridian Muscle. 3. The inner composition of meridian muscle in human arm is as follows ; 1) Muscle; ext. hallucis longus tend., flex. hallucis longus tend.(Sp-1), abd. hallucis tend., flex. hallucis brevis tend., flex. hallucis longus tend.(Sp-2, 3), ant. tibial m. tend., abd. hallucis, flex. hallucis longus tend.(Sp-4), flex. retinaculum, ant. tibiotalar lig.(Sp-5), flex. digitorum longus m., tibialis post. m.(Sp-6), soleus m., flex. digitorum longus m., tibialis post. m.(Sp-7, 8), gastrocnemius m., soleus m.(Sp-9), vastus medialis m.(Sp-10), sartorius m., vastus medialis m., add. longus m.(Sp-11), inguinal lig., iliopsoas m.(Sp-12), ext. abdominal oblique m. aponeurosis, int. abd. ob. m., transversus abd. m.(Sp-13, 14, 15, 16), ant. serratus m., intercostalis m.(Sp-17), pectoralis major m., pectoralis minor m., intercostalis m.(Sp-18, 19, 20), ant. serratus m., intercostalis m.(Sp-21) 2) Nerve; deep peroneal n. br.(Sp-1), med. plantar br. of post. tibial n.(Sp-2, 3, 4), saphenous n., deep peroneal n. br.(Sp-5), sural cutan. n., tibial. n.(Sp-6, 7, 8), tibial. n.(Sp-9), saphenous br. of femoral n.(Sp-10, 11), femoral n.(Sp-12), subcostal n. cut. br., iliohypogastric n., genitofemoral. n.(Sp-13), 11th. intercostal n. and its cut. br.(Sp-14), 10th. intercostal n. and its cut. br.(Sp-15), long thoracic n. br., 8th. intercostal n. and its cut. br.(Sp-16), long thoracic n. br., 5th. intercostal n. and its cut. br.(Sp-17), long thoracic n. br., 4th. intercostal n. and its cut. br.(Sp-18), long thoracic n. br., 3th. intercostal n. and its cut. br.(Sp-19), long thoracic n. br., 2th. intercostal n. and its cut. br.(Sp-20), long thoracic n. br., 6th. intercostal n. and its cut. br.(Sp-21) 3) Blood vessels; digital a. br. of dorsalis pedis a., post. tibial a. br.(Sp-1), med. plantar br. of post. tibial a.(Sp-2, 3, 4), saphenous vein, Ant. Med. malleolar a.(Sp-5), small saphenous v. br., post. tibial a.(Sp-6, 7), small saphenous v. br., post. tibial a., peroneal a.(Sp-8), post. tibial a.(Sp-9), long saphenose v. br., saphenous br. of femoral a.(Sp-10), deep femoral a. br.(Sp-11), femoral a.(Sp-12), supf. thoracoepigastric v., musculophrenic a.(Sp-16), thoracoepigastric v., lat. thoracic a. and v., 5th epigastric v., deep circumflex iliac a.(Sp-13, 14), supf. epigastric v., subcostal a., lumbar a.(Sp-15), intercostal a. v.(Sp-17), lat. thoracic a. and v., 4th intercostal a. v.(Sp-18), lat. thoracic a. and v., 3th intercostal a. v., axillary v. br.(Sp-19), lat. thoracic a. and v., 2th intercostal a. v., axillary v. br.(Sp-20), thoracoepigastric v., subscapular a. br., 6th intercostal a. v.(Sp-21)

  • PDF

A Novel on a Crops Management Growth System using Web and Design Development Method

  • Jung, Se-Hoon;Kim, Jong Chan;Kim, Cheeyong
    • Journal of Multimedia Information System
    • /
    • v.4 no.2
    • /
    • pp.93-98
    • /
    • 2017
  • A new cultivation diary system based on environment sensor data and Web 2.0 with Flex is suggested, to improve the previous system using the subjective data of cultivators. The proposed system is designed by applying an object-oriented model called mini-architecture, in order to enhance the reliability of software as well as promote stability to overall system design. The environment sensor data such as temperature and humidity are used to develop the new reliable diary. Also, an active interface based on Web 2.0 and Android as the user GUI are implemented to maximize the convenience while recording the cultivation diary. The result of the performance evaluation shows that the data from sensors has 99.1% of correlation with that of analogue.

A Study on the Assembly Process and Reliability of COF (Chip-On-Flex) Using ACFs (Anisotropic Conductive Films) for CCM (Compact Camera Module) (ACF를 이용한 CCM (Compact Camera Module)용 COF(Chip-On-Flex) 실장 기술 및 신뢰성 연구)

  • Chung, Chang-Kyu;Paik, Kyung-Wook
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.15 no.2
    • /
    • pp.7-15
    • /
    • 2008
  • In this paper, the Chip-On-Flex (COF) assembly process using anisotropic conductive films (ACFs) was investigated and the reliability of COF assemblies using ACFs was evaluated. Thermo-mechanical properties of ACFs such as coefficient of thermal expansion (CTE), storage modulus (E'), and glass transition temperature $(T_g)$ were measured to investigate the effects of ACF material properties on the reliability of COF assemblies using ACFs. In addition, the bonding conditions for COF assemblies using ACFs such as time, temperature, and pressure were optimized. After the COF assemblies using ACFs were fabricated with optimized bonding conditions, reliability tests were then carried out. According to the reliability test results, COF assemblies using the ACF which had lower CTE and higher $T_g$ showed better thermal cycling reliability. Consequently, thermo-mechanical properties of ACFs, especially $T_g$, should be improved for high thermal cycling reliability of COF assemblies using ACFs for compact camera module (CCM) applications.

  • PDF

Remote Control of Movable Robot Arm using Gyro Sensor and Flex Sensor (자이로센서와 플렉스 센서를 이용한 이동형 로봇팔 원격 제어)

  • Jang, Jae-Seok;Kim, Min-Soo;Kim, Seong-Jin;Lee, Cheol-Keun;Park, Hyoung-Keun
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.6
    • /
    • pp.1205-1212
    • /
    • 2021
  • Robots that can actually help people a lot by dealing with dangerous tasks that are difficult for people to do, such as disaster situations, lifesaving, handling dangerous goods, and reconnaissance of dangerous areas, continue to become an issue. Therefore, in this paper, we intend to implement a mobile robot arm that can implement a human motion will on the robot arm to enable active response according to the situation and control the vehicle according to hand movements to give mobility. A controller is manufactured using a flex sensor and agyro sensor, and the roll and pitch values of the two gyro sensors are adjusted to control the angle of the robot arm and specify the vehicle direction. In addition, by designating the levels of the three flex sensors, the motor is operated according to hand movements, and a robot arm is implemented so that objects can be picked up and moved.

Biomechanical Evaluation of SMA Dynamic Stabilization for Spinal fusion (척추고정용 형상기억합금 동적안정기기의 생체역학적 성능 평가)

  • Kim Y.H.;Park W.M.;Kim K.;Park H.K.;Joo J.W.;Park K.W.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.517-518
    • /
    • 2006
  • In this study, a commercial fixation device, BioFlex, which was designed with shape memory alloy(SMA) for dynamic stabilization of spine was biomechanically evaluated. The finite element model of intact lumbar spine from L1 to S was developed using CT images. Also, low FE models of 2-level(L4-L5-S) and 3-level(L3-L4-L5-S) posteriori fixation using titanium(Ti) rod and BioFlex(SMA) rod. The rotations of bone segments in the intact model and four models were predicted. Although the rotations of the BioFlex fixation model were smaller than those of the intact model, they were relatively larger than those of Ti fixation. The present can be applied for not only evaluation of the stability of interbody fixator, but also development of new implant.

  • PDF

Docking and Virtual Screening Studies for New Leads of Boar Salivary Lipocalin

  • Sung, Nack-Do;Park, Chang-Sik;Park, Hyung-Yeon;Kim, Chan-Kyung
    • Bulletin of the Korean Chemical Society
    • /
    • v.29 no.5
    • /
    • pp.959-962
    • /
    • 2008
  • We have performed FlexX docking experiments to predict the best docking poses of 5-androst-16-en-3-ol or 5-androst-16-en-3-one to Boar salivary lipocalin (SAL). Since no steroids were found inside of the binding pocket of the X-ray structure of 1GM6, we tried to find docking structures after opening the pocket using the random tweak option implemented in SYBYL. This operation allowed the ligand to enter the pocket. The best poses generated from FlexX were different from the structures reported earlier, which calculated docking poses by manual docking followed by minimization. Analysis of docking poses allowed us to identify pharmacophores. From this information, virtual screening experiments using UNITY were performed. Among six candidates, 3-(3,7-dimethyloct-6-enylamino)propane-1,2-diol (Leadquest code name: 5755) was chosen for further development. Future work will involve synthesis of some derivatives of 5755 and biological experiments if any derivatives can control the biostimulation and improve reproductive efficiency in pigs.

Influence of access cavity design on calcium hydroxide removal using different cleaning protocols: a confocal laser scanning microscopy study

  • Seda Falakaloglu;Merve Yeniceri Ozata;Betul Gunes;Emmanuel Joao Nogueira Leal Silva;Mustafa Gundogar;Burcu Gucyetmez Topal
    • Restorative Dentistry and Endodontics
    • /
    • v.48 no.3
    • /
    • pp.25.1-25.13
    • /
    • 2023
  • Objectives: The purpose of this study was to evaluate the influence of endodontic access cavities design on the removal of calcium hydroxide medication of the apical third of mandibular incisor root canal walls and dentinal tubules with different cleaning protocols: EDDY sonic activation, Er,Cr:YSGG laser-activated irrigation, or conventional irrigation with IrriFlex. Materials and Methods: Seventy-eight extracted human mandibular incisors were assigned to 6 experimental groups (n = 13) according to the endodontic access cavity and cleaning protocol for calcium hydroxide removal: traditional access cavity (TradAC)/EDDY; ultraconservative access cavity performed in the incisal edge (UltraAC.Inc)/EDDY; TradAC/Er,Cr:YSGG; UltraAC. Inc/Er,Cr:YSGG; TradAC/IrriFlex; or UltraAC.Inc/IrriFlex. Confocal laser scanning microscopy images were used to measure the non-penetration percentage, maximum residual calcium hydroxide penetration depth, and penetration area at 2 and 4 mm from the apex. Data were statistically analyzed using Shapiro-Wilk and WRS2 package for 2-way comparison of non-normally distributed parameters (depth of penetration, area of penetration, and percentage of non-penetration) according to cavity and cleaning protocol with the significance level set at 5%. Results: The effect of cavity and cleaning protocol interactions on penetration depth, penetration area and non-penetration percentage was not found statistically significant at 2 and 4 mm levels (p > 0.05). Conclusions: The present study demonstrated that TradAC or UltraAC.Inc preparations with different cleaning protocols in extracted mandibular incisors did not influence the remaining calcium hydroxide at 2 and 4 mm from the apex.