• Title/Summary/Keyword: 2-channel sensing

Search Result 234, Processing Time 0.031 seconds

Implementation Algorithms and Performance Analysis of Maritime VHF Data System Based on Filtered Multi-Tone Modulation (FMT 변조 기반의 해상 초단파 데이터 시스템의 구현 알고리즘 및 성능분석)

  • Park, Ok-Sun;Ahn, Jae-Min
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38C no.3
    • /
    • pp.254-262
    • /
    • 2013
  • This paper proposes FMT(Filtered Multi-Tone)-based digital radio implementation algorithms and the results obtained by various field tests especially in terms of transmitter characteristics. In this study, we predefined frame structure and protocols used for the CSTDMA(Carrier Sensing Time Division Multiple Access) scheme, designed digital filters and RF front end to fulfill the system characteristics such as the spectral mask and processing delays given by the Recommendation ITU-R M.1842-1. The proposed system supports exchange of data for e-Navigation with the usage of wider channel of 50-100kHz bandwidth, Turbo coding and FMT modulation. Furthermore, the common Ethernet protocol makes connection to local WLAN(Wireless Local Area Network) on board the ship for other data services.

Development of stratospheric Lidar for observation of volcano aerosols in the stratosphere over Korea (한반도 성층권 에어로졸 관측을 위한 성층권 라이다 개발)

  • Shin, Dong Ho;Noh, Young Min;Lee, Kwon H.;Jang, Eun Suk;Shin, Sung Kyun;Kim, Young J.
    • Korean Journal of Remote Sensing
    • /
    • v.29 no.5
    • /
    • pp.581-588
    • /
    • 2013
  • We developed the three channel lidar system to measure stratospheric aerosols at the Gwangju Institute for Science and Technology (GIST), a suburban site in Republic of Korea. The system provides backscatter coefficient (${\beta}$) at 532 and 1064 nm as well as depolarization ratios (${\delta}$) at 532 nm ($2{\beta}+1{\delta}$) using the doubled Nd:YAG laser wavelength at 532 and 1064 nm. The lidar system is optimized to measure stratospheric aerosols such as volcanic ashes. This paper describes the details of the optical setup, data acquisition system, and analysis method. This study shows an example of measuring stratospheric aerosols emitted by the volcanic eruption which occurred in Mt. Nabro ($13.37^{\circ}$ N, $41.70^{\circ}$ E).

Label-free Femtomolar Detection of Cancer Biomarker by Reduced Graphene Oxide Field-effect Transistor

  • Kim, Duck-Jin;Sohn, Il-Yung;Jung, Jin-Heak;Yoon, Ok-Ja;Lee, N.E.;Park, Joon-Shik
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.549-549
    • /
    • 2012
  • Early detection of cancer biomarkers in the blood is of vital importance for reducing the mortality and morbidity in a number of cancers. From this point of view, immunosensors based on nanowire (NW) and carbon nanotube (CNT) field-effect transistors (FETs) that allow the ultra-sensitive, highly specific, and label-free electrical detection of biomarkers received much attention. Nevertheless 1D nano-FET biosensors showed high performance, several challenges remain to be resolved for the uncomplicated, reproducible, low-cost and high-throughput nanofabrication. Recently, two-dimensional (2D) graphene and reduced GO (RGO) nanosheets or films find widespread applications such as clean energy storage and conversion devices, optical detector, field-effect transistors, electromechanical resonators, and chemical & biological sensors. In particular, the graphene- and RGO-FETs devices are very promising for sensing applications because of advantages including large detection area, low noise level in solution, ease of fabrication, and the high sensitivity to ions and biomolecules comparable to 1D nano-FETs. Even though a limited number of biosensor applications including chemical vapor deposition (CVD) grown graphene film for DNA detection, single-layer graphene for protein detection and single-layer graphene or solution-processed RGO film for cell monitoring have been reported, development of facile fabrication methods and full understanding of sensing mechanism are still lacking. Furthermore, there have been no reports on demonstration of ultrasensitive electrical detection of a cancer biomarker using the graphene- or RGO-FET. Here we describe scalable and facile fabrication of reduced graphene oxide FET (RGO-FET) with the capability of label-free, ultrasensitive electrical detection of a cancer biomarker, prostate specific antigen/${\alpha}$ 1-antichymotrypsin (PSA-ACT) complex, in which the ultrathin RGO channel was formed by a uniform self-assembly of two-dimensional RGO nanosheets, and also we will discuss about the immunosensing mechanism.

  • PDF

Application of Satellite Data on Geomorphological Study of the Tidal Flats near Kum River Estuary (위성자료의 한국 금강 하구부근 조간대 지형 연구에 대한 응용)

  • 안충현;이용국;유흥룡;오재경
    • Korean Journal of Remote Sensing
    • /
    • v.5 no.1
    • /
    • pp.1-12
    • /
    • 1989
  • The objective of this study is to develop the application techniques, such as geometrical correction, image overlapping etc., of LANDSAT Thematic Mapper image data especially useful to the geomorphological study of tidal flats. The developed processing techniques were applied to the Kum river estuary. The results of this study are as follows. 1) According to the analysis of the distribution and topographical profiles of the tidal flats, the geomorphological characteristics of the study area seem to be different depending on their location. 2) Even though the geomorphological changes were not always observable on the satellite images, several areas of undoubtful short-term deposition could be detected on the analytical map-image which compares two different situations of tidal flats. 3) Even though a further ditailed study is necessary, the distribution and dispersal patterns of suspended materials and sea surface temperature distribution patterns due to tidal and other meteorological conditions were analyzed by LANDSAT TM channel 3 and 6.

A Study on 2-Dimensional Sound Source Tracking System III - mainly on digital signal processing - (2차원적 음원추적에 관한 연구III - 디지털 신호처리를 중심으로 -)

  • 문성배;전승환
    • Journal of the Korean Institute of Navigation
    • /
    • v.24 no.5
    • /
    • pp.443-450
    • /
    • 2000
  • Before some experiments were carried out with analog bandpass filter which used for filtering the noise included in sound source signal. And this filter was constituted by condenser, register and operational amplifier. Hut these elements made the phase characteristics to differentiate in each sensing channel and cause a little of measurement error. We made new measurement system that was substituted digital filter for the analog filter in order to develop the optimal system which could find the time delay between each sensors with high accuracy. This paper describes the new system's constitution and the function of each parts. Specially three digital filters were designed and applied to the digital signal processing Part. And a series of experiments were carried out with the source's distance 9.53meters and the random bearing interval within the limits of $0^{\circ}$ ~ $180^{\circ}$. As a result, we have recognized that the accuracy of measurements were differentiated by the methods what kind of digital filter were adopted. And we have confirmed the facts that IIR LPF was suitable for sound source's bearing measurement and FIR LPF reduced the range measurement error.

  • PDF

COMPARISONS OF MTSAT-1R INFRARED CHANNEL MEASUREMENTS WITH MODIS/TERRA

  • Han, Hyo-Jin;Sohn, Byung-Ju;Park, Hye-Suk
    • Proceedings of the KSRS Conference
    • /
    • v.2
    • /
    • pp.651-654
    • /
    • 2006
  • Infrared channels of newly launched Japanese geostationary satellite, MTSAT-1R are compared with well calibrated MODIS/Terra infrared measurements at 3.7, 6.7, 11, 12 ${\mu}m$ bands. There are four steps in this intercalibration method: 1) data collection, 2) spectral response function correction, 3) data collocation, and 4) calculation of mean bias and conversion coefficients. In order to minimize the navigation error of MTSAT-1R, comparisons are made over the area in which the viewing angle of MTSAT-1R is less than 50$^{\circ}$. The calibration method was tested for August 2005 and within the 40$^{\circ}N$-40$^{\circ}S$, 100$^{\circ}$E-180$^{\circ}$E domain. The differences of spectral response functions were corrected through radiative transfer model simulation. Constructing collocated data differences in viewing geometry, observation time and space were taken into account. In order to avoid the radiance variation induced by cloud presence, clear-sky targets are selected as intercalibration target. The mean biases of 11, 12, 6.7, and 3.7 ${\mu}m$ bands are about -0.16, 0.36, 1.31, and -6.69 K, suggesting that accuracies of 3.7 ${\mu}m$ is questionable while other channels are comparable to MODIS

  • PDF

The Analysis of Tidal Channel Development Using Fractal (프랙탈 기법을 이용한 조류로 발달 양상의 분석)

  • Choi, Jung-Hyun;Eom, Jin-Ah;Lee, Yoon-Kyung;Ryu, Joo-Hyung;Won, Joong-Sun
    • Proceedings of the KSRS Conference
    • /
    • 2007.03a
    • /
    • pp.262-266
    • /
    • 2007
  • 조간대의 생물상과 조류로는 조간대 내의 모래나 펄을 구성하는 입자의 크기와 조성에 의하여 많은 영향을 받는다. 이런 조류로의 특성을 파악하기 위하여 전통적으로 현장조사를 실시하였으나 이 방법은 짧은 조간대의 노출시간 동안 넓은 조간대 지역을 파악하기 힘든 단점이 있다. 이러한 단점을 극복하기 위하여 최근 국내외적으로 위성자료와 현장조사롤 통해 조간대내의 조류로 발달을 연구하는 노력이 활발히 진행 중 이다. 본 연구에서는 프랙탈 이론을 적용하여 발달양상이 다른 두 지역의 조류로의 발달정도를 정량적인 값으로 나타내었다. 본 연구에서는 강화도 남단 조간대에 대하여 IKONOS 영상에서 조류로를 추출한 뒤, 프랙탈 분석방법 중 2차원 분석에 많이 사용되는 box counting 방법을 적용하여 프랙탈 차원을 구하였다. 분석 결과, 강화도 남단 조간대 전체 지역에 대한 프랙탈 차원 값은 약 1.31 로 나타났다. 조류로의 지선이 단순하며 남북으로 수직방향으로 발달한 지역은 프랙탈 차원 값이 $1.0563{\sim}1.0672$로 나타났으며,조류로의 지선이 발달하고 매우 복잡한 형태를 보이는 곳은 프랙탈 차원 값이 $1.255{\sim}1.3016$로 나타나는 것을 알 수 있었다. 실제 해안선과 같은 곡선의 경우 프랙탈 차원 값이 $1.1{\sim}1.3$ 정도 나타나는데 본 연구에서 얻어진 프랙탈 차원 값을 보면 매우 흡사하게 나온 것을 알 수가 있다. 또한, 양상이 다른 두 지역의 프랙탈 차원 값이 약 0.2 정도 차이를 나타내는 것을 알 수가 있다. 이 결과는 영상에서의 조류로 발달의 복잡성에 대한 구분을 뒷받침 할 수 있을 것으로 생각한다.

  • PDF

Improvement of MFL sensing-based damage detection and quantification for steel bar NDE

  • Kim, Ju-Won;Park, Minsu;Kim, Junkyeong;Park, Seunghee
    • Smart Structures and Systems
    • /
    • v.22 no.2
    • /
    • pp.239-247
    • /
    • 2018
  • A magnetic flux leakage (MFL) method was applied to detect and quantify defects in a steel bar. A multi-channel MFL sensor head was fabricated using Hall sensors and magnetization yokes with permanent magnets. The MFL sensor head scanned a damaged specimen with five levels of defects to measure the magnetic flux density. A series of signal processing procedures, including an enveloping process based on the Hilbert transform, was performed to clarify the flux leakage signal. The objective damage detection of the enveloped signals was then analyzed by comparing them to a threshold value. To quantitatively analyze the MFL signal according to the damage level, five kinds of damage indices based on the relationship between the enveloped MFL signal and the threshold value were applied. Using the proposed damage indices and the general damage index for the MFL method, the detected MFL signals were quantified and analyzed relative to the magnitude of the damage increase.

Assessment of Suboptimal Control in Turbulent Pipe Flow (원관내 유동에서의 준최적 제어의 평가)

  • Choe, Jeong-Il;Xu, C.X.;Seong, Hyeong-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.2
    • /
    • pp.345-352
    • /
    • 2002
  • A suboptimal control law in turbulent pipe flow is derived and tested. Two sensing variables ∂p/∂$\theta$$\_$w/ and ∂v$\_$$\theta$/∂γ│$\_$w/ are applied with two actuations ø$\_$$\theta$/ and ø$\_$γ/. To test the suboptimal control law, direct numerical simulations of turbulent pipe flow at Re$\_$$\tau$/=150 are performed. When the control law is applied, a 13∼23% drag reduction is achieved. The most effective drag reduction is made at the pair of ∂v$\_$$\theta$/∂γ│$\_$w/ and ø$\_$γ/. An impenetrable virtual wall concept is useful for analyzing the near-wall suction and blowing. The virtual wall concept is useful for analyzing the near-wall behavior of the controlled flow. Comparison of the present suboptimal control with that of turbulent channel flow reveals that the curvature effect is insignificant.

A water stress evaluation over forest canopy using NDWI in Korean peninsula (NDWI를 활용한 한반도 지역의 산림 캐노피에 대한 water stress 평가)

  • Seong, Nohun;Seo, Minji;Lee, Kyeong-Sang;Lee, Changsuk;Kim, Hyunji;Choi, Sungwon;Han, Kyung-Soo
    • Korean Journal of Remote Sensing
    • /
    • v.31 no.2
    • /
    • pp.77-83
    • /
    • 2015
  • Leaf water content is one of important indicators that shows states of vegetation. It is important to monitor vegetation water content using remote sensing for forest management. In this study, we investigated the degree of water stress in Korean peninsula with Normalized Difference Water Index (NDWI) to study the water content of vegetation canopy. We calculated the NDWI using SPOT/VEGETATION S10 channel data over forest from 1999 to 2013. We calculated Simple Moving Average (SMA) to remove temporal noises of NDWI in time series, and used standardized anomaly to investigate temporal changes. We classified the NDWI anomalies into three scales (low, moderate, and high) in order to monitor intuitively. We also investigated suitability of the NDWI as an evaluation criterion about water stress of vegetation canopy by comparing and verifying forest fires damaged area over 150 ha. Consequently, huge forest fire occurred 24 times during the study period. Also, negative anomalies appeared in every forest fire location and their neighboring areas. In particular, we found huge forest fires where NDWI anomalies were in 'high' scale.