• 제목/요약/키워드: 2-Phase

검색결과 24,149건 처리시간 0.05초

LHTL 위상변위기를 이용한 4×4 광대역 위상배열안테나 (4×4 Broadband Phased Array Antenna Using LHTL Based Phase Shifter)

  • 박순우;김홍준
    • 전기학회논문지
    • /
    • 제66권2호
    • /
    • pp.379-382
    • /
    • 2017
  • This paper proposes a $4{\times}4$ broadband phased array antenna using a Left-Handed Transmission Line (LHTL) based phase shifter. The phased array is constructed with sixteen quasi-Yagi antenna elements and the phase shifters, as well as four power dividers. A key component of the system, the LHTL based phase shifter is able to control a phase delay of incident waves linearly and continuously. The fabricated phased array antenna operate for a frequency range of 800 MHz (1.6 GHz~2.4 GHz). The beam scanning range of the $4{\times}4$ array antenna is ${\pm}27^{\circ}$ horizontally and vertically while the antenna gain is maintained with a variation of ${\pm}1.4dBi$.

비선형 위상공간에서의 기포 분율 신호의 끌개밀도분식을 이용한 수직 상향 이상유동의 유동패턴분류 (Flow Pattern Identification of Vertical Upward Two-Phase Flow Using the Attractor-Density-Map Analysis of the Void Fraction Signal in the Nonlinear Phase Space)

  • 김남석;이재영
    • 대한기계학회논문집B
    • /
    • 제28권11호
    • /
    • pp.1398-1406
    • /
    • 2004
  • The nonlinear signals from an impedance meter for the area average void fraction in two-phase flow have been analyzed to construct a phase space trajectory. The pseudo phase space was constructed with the time delay and proper dimensions. The time delay and the embedding dimension were chosen by the average mutual information and by the false nearest neighborhood, respectively. The attractor-density-map of projected states was used to produce the two dimensional probability distribution functions (2D-PDF). Since the developed 2D-PDF showed clear distinction of the flow patterns, the flow regime identification was made with three rules and with the 2D-PDF. Also, the transition criteria of Mishima-Ishii agree well with the present results.

3.5% NaCl 수용액의 pH변화가 복합조직강의 부식피로파괴에 미치는 영향 (Influence of pH in 3.5% NaCl aqueous solution on corrosion fatigue-fracture of dual phase steel)

  • 오세욱;안호민;도영문
    • 한국해양공학회지
    • /
    • 제1권2호
    • /
    • pp.123-129
    • /
    • 1987
  • Corrosion fatigue fracture of dual phase steel(SS41) and raw material steel(SS41) were investigated in 3.5% NaCl aqueous solution at PH 4,6,9 and 11. The fatigue limit of dual phase steel is increased approximately 1.8 times larger than that of raw material in air. The corrosion fatigue life of dual phase steel is about 5-10 times larger than that of raw material in 3.5% NaCl aqueous solution. The reduction of fatigue life is larger for the acidsalt solution than for the alkali salt solution. The reduction of stress level on the reduction ratio of corrosion fatigue life is large as pH 6-11. The reduction ratio of corrosion fatigue life of dual phase steel and raw material is nearly coincided at pH 2. While at pH4-2 the reduction ratio of corrosion fatigue life only depends on the corrosion effect. It has been found that the corrosion resistance effect of dual phase steel is smaller than that of raw material in corrosion fatigue crack propagation rate. As pH below 6 is changed, it can be clearly observed from raw material that the brittle intergranular fracture is characterized, and from the above result, the influence of corrosion of dual phase steel is small.

  • PDF

Antiferroelectric and antiferrodistortive phase transitions in Ruddlesden-Popper Pb2TiO4 from first-principles

  • Xu, Tao;Shimada, Takahiro;Wang, Jie;Kitamura, Takayuki
    • Coupled systems mechanics
    • /
    • 제6권1호
    • /
    • pp.29-40
    • /
    • 2017
  • This work employed density functional theory to investigate the structural and ferroelectric properties of the Ruddlesden-Popper (RP) phase of lead titanate, $Pb_2TiO_4$, as well as its phase transitions with epitaxial strain. A wealth of novel structural instabilities, which are absent in the host $PbTiO_3$ material, were identified in the RP phase through phonon soft-mode analysis. Our calculations showed that the ground state of $Pb_2TiO_4$ is antiferroelectric, distinct from the dominant ferroelectric phase in the corresponding host material. In addition, applied epitaxial strain was found to play a key role in the interactions among the instabilities. The induction of a sequence of antiferroelectric and antiferrodistortive (AFD) phase transitions by epitaxial strain was demonstrated, in which the ferroic instability and AFD distortion were cooperative rather than competitive, as is the case in the host $PbTiO_3$. The RP phase in conjunction with strain engineering thus represents a new approach to creating ferroic orders and modifying the interplay among structural instabilities in the same constituent materials, enabling us to tailor the functionality of perovskite oxides for novel device applications.

간 전이환자에서 최적의 펄스시퀀스에 따른 SPIO 특이성 조영제의 국소병변검출: Case review (Focal Lesion Detection of SPIO-specific agent Compared with Optimized Pulse Sequences in the Hepatic Metastases: Case Review)

  • 구은회
    • 대한디지털의료영상학회논문지
    • /
    • 제14권2호
    • /
    • pp.57-61
    • /
    • 2012
  • To compare the accuracy of breath-hold magnetic resonance imaging sequences to establish the most effective superparamagnetic iron oxide-enhanced sequence for detection of hepatic metastases. A total of 100 patients(50men and 50women, mean age: 60years) with liver disease(including malignant and benign liver lesions) were investigated at 3.0T machine (GE, General Electric Medical System, Excite HD) with 8Ch body coil. Pulse sequence for MR imaging decided to the FS-T2-FSE-RT(TR/TE/Thick./Freq./Phase=12857ms/100ms/7mm/512/384), MGRE(TR/TE/Thick./Freq./Phase=100ms/9.7ms/7mm/384/288), in-out of phase echo(TR/$TE_1$, $TE_2$/Thick./Freq./Phase=140ms/2.4, 5.8ms/7mm/352/300), Images obtained before the injection of SPIO. Six sequences were optimized for lesion detection: FS-T2-FSE-RT, multigradient recalled echo data image(MGRE), T2-weighted MGRE with an 9.7msec echo time. Images were reviewed independently by five blinded observers. The accuracy of each sequence was measured by using picture archiving communication system analysis. All results were correlated with findings at multidectator computed tomography examination. Differences between the mean results of the six observers were measured by using paired student t-test analysis. Postcontrast T2-weighted MGRE sequences were the most accurate and were significantly superior to postcontrast FS-T2-FSE-RT, T2-weighted MGRE, in-out of phase MR sequences(p < .05). For all lesions that were malignant or smaller than 1 cm, respectively, contrast to noise ratio of pre and postcontrast sequences were -1and -0.3 for T2-weighted FSE, 0.53 and 4.5 in-out of phase, 7, 7.08, 5.08, 3.32, 1.7, 1.16, 0.79, 0.68 for GRE with 2.9, 7.5, 12.1, 16.6, 21.2, 25.8, 30.4, 35.0 TE values. Breath-hold various TE precontrast sequences offer improvement in sensitivity compared with fixed multigradient recalled echo sequences alone.

  • PDF

인삼전지의 토양특성이 인삼의 생육및 수량에 미치는 영향에 관한 연구 (Influence of Various Soil CharacteriBtics in GinBeng Field or the Growth and the Yield of Ginseng (Panax gisoseng C. A. Meyer))

  • 이일호;육창수;한강완;박찬수;박현석;남기열
    • Journal of Ginseng Research
    • /
    • 제4권2호
    • /
    • pp.175-185
    • /
    • 1980
  • A study was made to clarify the topographical. and Physical characteristics of ginseng field in terms of soil science and to find the relationship between soil characteristics and ginseng growth, as well as yield of ginseng roots Forty nine farmer's red ginseng field of ginseng growing area were chosen for this study and investigated for two years. The results obtained were as follow. 1. Ginseng fie1ds with high yield which represent the more than 1.8kg of ginseng root per 3.2m2 were found in soil series of Bancheon, Yeongog, Weongog, etc. whose texture were the clay loam to clay soil. On the other hand, ginseng field with low yield were observed in soil series of seogto whose texture was loamy soil with high content of gravels. 2 Soil of ginseng field with high yield had higher content of clay. silt soil moisture and soil pore as compared with soils of low yields. These soil characteristics were positively correlated with stem length stem diameter and root weight of ginseng plsnt and negatively correlated with rate of missing plant 3. The adequate ranges of soil 3 phase from high yield ginseng field were 40 to 50% of solid Phase, 22 to 35% of liquid phase, 25 to 35% of gaseous phase in top soil and 45 to 55% of solid phase. 28 to 30% of liquid phase. 15 to 20% of gaseous phase in subsoil respectively.

  • PDF

유도 허벅다리걸기 기술 발휘 시 지지발에 대한 근전도 및 운동역학적 분석 (The Kinetic and EMG Analysis about Supporting Leg of Uke in Judo)

  • 박종율;김태완;최인애
    • 한국운동역학회지
    • /
    • 제17권2호
    • /
    • pp.197-205
    • /
    • 2007
  • The purpose of this study is to analyze the muscle activations and Ground Reaction Force(GRF) in university judo players, and provide the guide of training in Judo. Using surface electrode electromyography(EMG), we evaluated muscle activity in 5 university judo players during the Judo Uke Movements. Surface electrodes were used to record the level of muscle activity in the Tibialis Anterior, Rectus Femoris, Elector Spinae, Gluteus Maximus, Gastrocnemius muscles during the Uke. These signals were compared with %RVC(Reference voluntary contraction) which was normalized by IEMG(Integrated EMG). The Uke was divided into four phases : Kuzushi-1, Kuzushi-2, Tsukuri, Kake. The results can be summarized as follows: 1. The effective Uke Movements needs to short time in the Kake Phase 2. The Analysis of Electromyography of Uke Movements in Supporting Leg; TA(Tibialis anterior) had Higher %RVC in the Kuzushi Phase, RF(Rectus Femoris) had Higher %RVC in the Tsukuri Phase, GM(Gluteus Maximus) had Higher %RVC in the Kake Phase 3. The ground reaction force for Z(vertical) direction was showed increase tendency in Kuzushi phase, Tsukuri phase and decrease tendency in Kake phase.

Cu-Zn-Al 형상기억합금에서 기계적 성질에 미치는 결정형상의 영향에 관한 연구;주조조직과 재결정처리에 따른 기계적 성질과 형상기억능의 변화 (Study on the Effect of Crystal Morphology on Mechanical Property in Cu-Zn-Al Shape Memory Alloy)

  • 황승준;이진형;홍종휘
    • 한국주조공학회지
    • /
    • 제9권1호
    • /
    • pp.58-66
    • /
    • 1989
  • The effect of heat treating temperature and ${\alpha}$ phase In the ${\beta}$ phase matrix were investigated for ${\beta}-CuZnAl$ shape memory alloys by tension test, fatigue test, and shape memory effect test. After heat treatment at $677^{\circ}C$, $750^{\circ}C$, $800^{\circ}C$ and $850^{\circ}C$ for 10 min. respectively, static fracture stress(${\sigma}_f$), fatigue fracture stress(${\tau}_{max}$) at $10^6$ cycle, and elongation(${\epsilon}_f$) was $24.2kg/mm^2$, $17.21kg/mm^2$ and 11.8%, respectively. As heat treating temperature decreased, fracture surfaces of the specimens were changed from the intergranular to the transgranular fracture mode. Especially, the a phase precipitated in the ${\beta}$ phase matrix had an effect on crack propagation and the fracture surface was characterized by dimple-like pattern when crack propagated in transgranular cracking mode. Precipitation of the ${\alpha}$ phase in the ${\beta}$ phase matrix lowered the transformation temperature by $10^{\circ}C$, and about 2.5 vol.% ${\alpha}$ phase did not affect the shape memory effect examined by the bending test.

  • PDF

위성 변조 비콘 신호의 2위상 특성을 이용한 주파수 오프셋 보상방법에 대한 연구 (A Study on Frequency Offset Compensation using 2-Phase Characteristic of Beacon Signal modulated by Satellite)

  • 최철희
    • 한국인터넷방송통신학회논문지
    • /
    • 제18권1호
    • /
    • pp.97-103
    • /
    • 2018
  • 위성 변조 비콘 신호는 위성에서 생성한 TOD (Time of Day) 데이터를 gold sequence를 이용하여 확산 시킨 후 linear phase modulation을 통해 전송된다. 변조 비콘 신호를 수신 시 위성과 지상 수신기 간 특성 차이 때문에 주파수 오프셋(FO)이 발생한다. 기존 위성 변조 비콘 수신기는 변조 비콘 신호를 FFT(Fast Fourier Transform)를 이용하여 주파수를 동기화시키는 방법이며, 이는 시스템 구현 관점에서 딜레이 및 복잡도를 증가 시킬 뿐만 아니라 points 간 생기는 FO과 phase offset에 의한 위상차를 보정하는 별도의 회로가 필요하다. 본 논문에서는 이를 극복하기 위해 변조 비콘 신호의 2위상 성형된 특성을 이용하여 coarse FO와 phase offset을 한 번에 보정 및 복조하기 위한 방안과 그에 따른 하드웨어 구성도를 제안 및 분석하였다. 또한, 시뮬레이션을 통해 본 논문에서 제안하는 방식에 적합한 변조 지수(modulation index)를 분석하였으며 그에 따른 적정 누적 개수 또한 분석하였다.

원자력발전소 변압기 연결 선로 결상 검출 시스템 (Open-Phase Condition Detecting System for Transformer Connected Power Line in Nuclear Power Plant)

  • 하체웅;이도환
    • 전기학회논문지
    • /
    • 제64권2호
    • /
    • pp.254-259
    • /
    • 2015
  • On January 30, 2012 an auxiliary component of Byron Unit 2 was tripped on bus under voltage. The cause of the event was the failure of the C-phase insulator track for the Unit 2 station auxiliary transformer(SAT) revenue metering transformer. In addition to this event, other events have occurred at other plants resulting in an open-phase condition.[1] Therefore, Nuclear Regulatory Commission(NRC) has requested that not only nuclear power plant(NPP) operating company but also its Design Certification(DC) applicant have to prepare open-phase detecting system in their operating plants and design document. In this paper, various open-phase conditions are simulated in NPP using Electromagnetic Transient Program(EMTP) and Atpdraw, and open-phase condition detecting system is proposed for Main Transformer(MT), Unit Auxiliary Transformer(UAT) and SAT connected power line in NPP.