• Title/Summary/Keyword: 2-Dimensional

Search Result 15,171, Processing Time 0.046 seconds

Community Structure of Macrobenthic Fauna in the Hallyeohaesang National Park from Korea Strait, Korea (한려해상국립공원 조하대 해역 대형저서동물의 군집구조)

  • Yoon, Kon-Tak;Seo, In-Soo;Kim, Kwang-Bong;Cho, Byoung-Mi;Son, Min-Ho
    • Korean Journal of Environmental Biology
    • /
    • v.27 no.1
    • /
    • pp.124-133
    • /
    • 2009
  • The study was performed to investigate the community structure of macrobenthic fauna during June 2005, in Hallyeohaesang National Park from Korea Strait. A total of 284 macrobenthic fauna were collected. The overall average macrobenthic density and biomass were 2,002 individuals m$^{-2}$ and 154.92 gWWt m$^{-2}$, respectively. Based on the Lebris (1988) index, there were 20 species accounting for approximately 47.64% of total individuals. And the highest densities were found in the polychaetes Scoletoma longifolia, Isolda pulchella, Mediomastus californiensis, Minuspio multibranchia, Tharyx sp. 1 and the bivalve Theora fragilis. On the other hand, the top twenty species made up 70.47% of the total biomass while the three most abundant, the echinoderms Schizaster lacunosus, Amphiura vadicola and the bivalve Fulvia mutica. The conventional multivariate statistics (cluster analysis and non-metric Multi-Dimensional Scaling) applied to assess spatial variation in macrobenthic assemblages. As a result of cluster analysis and nMDS ordination, this study area was divided into two different groups of stations and species. In case of station, there are two groups: one is a mud dominated station group and the other is dead shell and sand dominated group. And the 2 faunistic groups were established as follows: 1) a group of relatively higher abundances in mud dominated sediment. There were numerically dominated by the polychaetes Magelona japonica, Sternaspis scutata, Paraprionospio pinnata, Tharyx sp. 1 and the amphipods Monocorophium sinense and Eriopisella sechellensis. 2) a group of relatively higher densities dead shell and sand dominated sediment. These groups were characterized by the polychaetes I. pulchella, M. multibranchiata, the amphipods M. acherusicum, Gammaropsis japonicus and the echinoderm A. vadicola.

Effect of Heat-Killed Enterococcus faecalis, EF-2001 on C2C12 Myoblast Damage Induced by Oxidative Stress and Muscle Volume Decreased by Sciatic Denervation in C57BL/6 Mice (산화스트레스에 의해 유도된 C2C12 근세포 손상과, 신경절제에 의해 근감소가 유도된 C57BL/6 마우스에서 열처리 사균체 엔테로코커스 패칼리스 EF-2001의 효과)

  • Chang, Sang-Jin;Lee, Myung-Hun;Kim, Wan-Joong;Chae, Yuri;Iwasa, Masahiro;Han, Kwon-Il;Kim, Wan-Jae;Kim, Tack-Joong
    • Journal of Life Science
    • /
    • v.29 no.2
    • /
    • pp.215-222
    • /
    • 2019
  • Muscle dysfunction may arise from skeletal muscle atrophy caused by aging, injury, oxidative stress, and hereditary disease. Powdered heat-killed Enterococcus faecalis (EF-2001) has anti-allergy, anti-inflammatory, and anti-tumor effects. However, its antioxidant and anti-atrophy effects are poorly characterized. In this study, we examined the effects of EF-2001 on muscle atrophy. To determine the protective effect of EF-2001 on oxidative stress, C2C12 myoblasts were treated with $H_2O_2$ to induce oxidative stress. This induced cell damage, which was reduced by treatment with EF-2001. The mechanism of EF-2001's effect was examined in response to oxidative stress. Treatment with EF-2001 reversed the expression of HSP70 and SOD1 proteins. Also, mRNA levels of Atrogin-1/MAFbx and MuRF1 increased under oxidative stress conditions but decreased following EF-2001 treatment. To evaluate muscle volume, two and three dimensional models of the muscles were analyzed using micro-CT. As expected, muscle volume decreased after sciatic denervation and recovered after oral administration of EF-2001. Therefore, EF-2001 is a candidate for the treatment of muscular atrophy, and future discovery of the additional effects of EF-2001 may yield further applications as a functional food with useful activities in various fields.

Evaluation of Bone Change by Digital Subtraction Radiography after Implantation of Tooth Ash-plaster Mixture (치아회분과 석고혼합제제 매식후 Digital Subtraction Radiography에 의한 골량 변화의 평가)

  • Kim Jae-Duk;Kim Kwang-Won;Cho Yaung-Gon;Kim Dong-Kie;Choi Eui-Hwan
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.2
    • /
    • pp.423-433
    • /
    • 1999
  • Purpose : To assess the methods for the clinical evaluation of the longitudinal bone changes after implantation of tooth ash-plaster mixture into the defect area of human jaws. Materials and methods : Tooth ash-plaster mixtures were implanted into the defects of 8 human jaws. 48 intraoral radiograms taken with copper step wedge as reference at soon, 1st, 2nd, 4th, and 6th week after implantation of mixture were used. X-ray taking was standardized by using Rinn XCP device customized directly to the individual dentition with resin bite block. The images inputted by Quick scanner were digitized and analyzed by NIH image program. Cu­equivalent values were measured at the implanted sites from the periodic digital images. Analysis was performed by the bidirectional subtraction with color enhancement and the surface plot of resliced contiguous image. The obtained results by the two methods were compared with Cu­equivalent value changes. Results : The average determination coefficient of Cu-equivalent equations was 0.9988 and the coefficient of variation of measured Cu values ranged from 0.08~0.10. The coefficient of variation of Cu-equivalent values measured at the areas of the mixture and the bone by the conversion equation ranged from 0.06 ~0.09. The analyzed results by the bidirectional subtraction with color enhancement were coincident with the changes of Cu-equivalent values. The surface plot of the resliced contiguous image showed the three dimensional view of the longitudinal bone changes on one image and also coincident with Cu-equivalent value changes after implantation. Conclusion : The bidirectional subtraction with color enhancement and the surface plot of the resliced contiguous image was very effective and reasonable to analyze clinically and qualitatively the longitudinal bone change. These methods are expected to be applicable to the non-destructive test in other fields.

  • PDF

Correlation between Oriental Medicine Diagnosis and the Autonomic Nervous System Functions of Hyperhidrosis Patients (다한증 환자의 한의학적 변증특성 및 자율신경계 기능과의 상관관계)

  • Lee, Sung-Hun;Kim, Jae-Hwan;Roh, Yeong-lae;Rhee, Hyung-Koo;Jeong, Seung-Yeon;Jung, Sung-Ki;Jung, Hee-Jae
    • The Journal of Internal Korean Medicine
    • /
    • v.29 no.2
    • /
    • pp.359-374
    • /
    • 2008
  • Objective : Hyperhidrosis is a condition characterized by excessive sweating. Some studies suggest that hyperhidrosis is associated with autonomic nervous system dysfunction. Hyperhidrosis is often accompanied by hypersensitivity, tension, irritability, heat flashes, fatigue, etc. This study was designed to evaluate the correlation between Oriental Medicine diagnosis and the autonomic nervous system function in patients with hyperhidrosis using Heart Rate Variability (HRV) analysis. Methods : 23 palmar and plantar hyperhidrosis patients and 10 systemic hyperhidrosis patients were recruited and evaluated by Oriental Medicine diagnostic questionnaire and HRV analysis. The Oriental Medicine diagnostic questionnaire used a three-dimensional diagnosis that classified patients into Cold or Heat Syndrome, Yin or Yang Syndrome, and Deficiency or Excess Syndrome. Measured indices of HRV used the frequency domain analysis(i.e. TP, VLF, LF, HF and LF/HF ratio). Also, measure indices of HRV adjusted for aging effects were evaluated. Results : Cold/Heat Syndrome was not associated with hyperhidrosis prevalence nor the HRV analysis in hyperhidrosis patients. The Yang Syndrome group(78.8%) was more strongly correlated than the Yin Syndrome group(21.2%), and character of Yang was correlated with the adjusted TP and adjusted LF. The LF/HF ratio in the Excess Syndrome group was significantly higher than the LF/HF ratio in the Deficiency Syndrome group. Conclusion : Hyperhidrosis was not associated with the Cold/Heat Syndrome, but was found to be closely associated with the Yang Syndrome. The LF/HF ratio was significantly higher in the Excess Syndrome group than in the Deficiency Syndrome group in hyperhidrosis patients.

  • PDF

Analysis of the GPS-derived Control Point Errors for Quality Assurance of 3D Digital Maps (3차원 수치지도 정확도 검증을 위한 GPS 기반 기준점 오차의 영향 분석)

  • Bae, Tae-Suk;Lee, Dong-Cheon
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.28 no.1
    • /
    • pp.153-160
    • /
    • 2010
  • It is necessary to determine accurate 3-dimensional coordinates of the building corner points that could be control or check points in order to verify the accuracy of 3D digital maps in the near future. The usual process of obtaining the coordinates of the building corner points is to set up the ground control points with a GPS and then to practice terrestrial survey such as distance or angle measurements. However, since an error in the ground control points can be propagated through the terrestrial survey into the final coordinates of the buildings, accurately should be considered as much as possible. The actual effect of the GPS-derived ground control point error on the estimates of the unknowns through the terrestrial survey is mathematically analyzed, and the simulation data is tested numerically. The error of the ground control points is tested in the cases of 1-4 cm for the horizontal components and 2-8 cm for the vertical component. The vertical component error is assigned twice the horizontal ones because of the characteristics of the GPS survey. The distance measurement is assumed for convenience and the precision of the estimated coordinates of the building corner points is almost linearly increased according to the errors of the ground control points. In addition, the final estimates themselves can vary by the simulated random errors depending on the precision of the survey instrument, but the precision of the estimates is almost independent of survey accuracy.

Modeling of Earthquake Ground Motion in a Small-Scale Basin (소규모 분지에서의 지진 지반운동 모델링)

  • Kang, Tae-Seob
    • Geophysics and Geophysical Exploration
    • /
    • v.15 no.2
    • /
    • pp.92-101
    • /
    • 2012
  • Three-dimensional finite-difference simulation in a small-scale half-sphere basin with planar free-surface is performed for an arbitrary shear-dislocation point source. A new scheme to deal with free-surface boundary condition is presented. Then basin parameters are examined to understand main characteristics on ground-motion response in the basin. To analyze the frequency content of ground motion in the basin, spectral amplitudes are compared with each other for four sites inside and outside the basin. Also particle motions for those sites are examined to find which kind of wave plays a dominant role in ground-motion response. The results show that seismic energy is concentrated on a marginal area of the basin far from the source. This focusing effect is mainly due to constructive interference of the direct Swave with basin-edge induced surface waves. Also, ground-motion amplification over the deepest part of the basin is relatively lower than that above shallow basin edge. In the small-scale basin with relatively simple bedrock interface, therefore, the ground-motion amplification may be more related to the source azimuth or direction of the incident waves into the basin rather than depth of it.

Articulated Human Body Tracking Using Belief Propagation with Disparity Map (신뢰 전파와 디스패리티 맵을 사용한 다관절체 사람 추적)

  • Yoon, Kwang-Jin;Kim, Tae-Yong
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.49 no.3
    • /
    • pp.51-59
    • /
    • 2012
  • This paper suggests an efficient method which tracks articulated human body modeled with markov network using disparity map derived from stereo images. The conventional methods which only use color information to calculate likelihood for energy function tend to fail when background has same colors with objects or appearances of object are changed during the movement. In this paper, we present a method evaluating likelihood with both disparity information and color information to find human body parts. Since the human body part are cylinder projected to rectangles in 2D image plane, we use the properties of distribution of disparity of those rectangles that do not have discontinuous distribution. In addition to that we suggest a conditional-messages-update that is able to reduce unnecessary message update of belief propagation. Since the message update has comprised over 80% of the whole computation in belief propagation, the conditional-message-update yields 9~45% of improvements of computational time. Furthermore, we also propose an another speed up method called three dimensional dynamic models assumed the body motion is continuous. The experiment results show that the proposed method reduces the computational time as well as it increases tracking accuracy.

Validity analysis of the social emotion model based on relation types in SNS (SNS 사용자의 관계유형에 따른 사회감성 모델의 타당화 분석)

  • Cha, Ye-Sool;Kim, Ji-Hye;Kim, Jong-Hwa;Kim, Song-Yi;Kim, Dong-Keun;Whang, Min-Cheol
    • Science of Emotion and Sensibility
    • /
    • v.15 no.2
    • /
    • pp.283-296
    • /
    • 2012
  • The goal of this study is to determine the social emotion model as an emotion sharing relationship and information sharing relationship based on the user's relations at social networking services. 26 social emotions were extracted by verification of compliance among 92 different emotions collected from the literature survey. The survey on the 26 emotion words was verified to the similarity of social relation types to the Likert 7-points scale. The principal component analysis of the survey data determined 12 representative social emotions in the emotion sharing relation and 13 representative social emotions in the information sharing relation. Multidimensional scaling developed the two-dimensional social emotion model of emotion sharing relation and of information sharing relation based on online communication environment. Meanwhile, insignificant factors in the suggest social emotion models were removed by the structural equation modeling analysis, statistically. The test result of validity analysis demonstrated the fitness of social emotion models at emotion sharing relationships (CFI: .887, TLI: .885, RMSEA: .094), social emotion model of information sharing relationships (CFI: .917, TLI: .900, RMSEA : 0.050). In conclusion, this study presents two different social emotion models based on two different relation types. The findings of this study will provide not only a reference of evaluating social emotions in designing social networking services but also a direction of improving social emotions.

  • PDF

Use of Two Dimensional Electrical Resistivity Tomography to Identify Soil Water Dynamics and the Effective Plant Root Zone

  • Yoon, Sung-Won;Zhang, Yong-Seon;Han, Kyung-Hwa;Jo, Hee-Rae;Ha, Sang-Keun;Park, Sam-Kyeu;Sonn, Yeon-Kyu
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.45 no.3
    • /
    • pp.353-359
    • /
    • 2012
  • The identification of effective root zone would clarify dynamics of plant available water and soil water balance. Using the relationship between soil properties and electrical resistivity (ER) the purpose of this research is to identify soil zone affected by a plant root activity using electrical resistivity tomography (ERT) technique. Four plastic containers were prepared for two different soil textures (clay and sandy loam) and one container for each texture was selected for planting four corn seedlings (Zea mays L.) and the others were prepared for the blank. For ERT monitoring, we prepared 0.8 m plastic sticks with 17 electrodes installed with 5 cm space. The Ministing (AGI Inc., Texas) instrument for electrical resistivity measurement and semi-auto converter of electrode arrangement were set up for dipole-dipole array. During 2 months of the corns growing, ERT monitoring was made 3 to 4 days after the irrigation practice. Despite of the same amount water supplied into soils, two textures showed very different apparent resistivity values due to different clay content. The apparent electrical resistivity is consistently lower in clay loam comparing to sandy loam soil implying that plant root does not significantly alter the overall trend of resistivity. When plant root system, however, is active both soils with plants showed 2-7 times higher electrical resistivity and higher coefficient variation than soils without plant, implying the effect of root system on the resistivity, in which may caused by. This result suggests plant root activities regulating the soil water dynamics mainly control the variation of electrical resistivity over soil textural difference. Therefore the identification of water uptake zone would highly be correlated to plant root activities, thus ERT will be feasible approach to identify spatial characteristics of a plant root activity.

The Effect on the Lower Limbs Joint as the Landing Height and Floor Pattern (착지 높이와 지면 형태가 하지 관절에 미치는 영향)

  • Kim, Eun-Kyong
    • Korean Journal of Applied Biomechanics
    • /
    • v.21 no.4
    • /
    • pp.437-447
    • /
    • 2011
  • In this study, the lower limbs joints were analyzed for features based on the biomechanical characteristics of landing techniques according to height and landing on the ground type (flats and downhill). In order to achieve the objectives of the study, changes were analyzed in detail contents such as the height and form of the first landing on the ground at different angles of joints, torso and legs, torso and legs of the difference in the range of angular motion of the joint, the maximum angular difference between joints, the lower limbs joints difference between the maximum moment and the difference between COM changes. The subjects in this study do not last six months did not experience joint injuries 10 males in 20 aged were tested. Experimental tools to analyze were the recording and video equipment. Samsung's SCH-650A model camera was used six units, and the 2 GRF-based AMTI were used BP400800 model. 6-unit-camera synchronized with LED (photo cell) and Line Lock system were used. the output from the camera and the ground reaction force based on the data to synchronize A/D Syc. box was used. To calculate the coordinates of three-dimensional space, $1m{\times}3m{\times}2m$ (X, Y, Z axis) to the size of the control points attached to the framework of 36 markers were used, and 29 where the body was taken by attaching a marker to the surface. Two kinds of land condition, 40cm and 60cm in height, and ground conditions in the form of two kinds of flat and downhill slopes ($10^{\circ}$) of the landing operation was performed and each subject's 3 mean two-way RM ANOVA in SPSS 18.0 was used and this time, all the significant level was set at a=.05. Consequently, analyzing the landing technique as land form and land on the ground, the changes of external environmental factors, and the lower limbs joints' function in the evaluation were significantly different from the slopes. Landing of the slop plane were more load on the joints than landing of plane. Especially, knee extensor moment compared to the two kinds of landing, slopes plane were approximately two times higher than flat plane, and it was statistical significance. Most of all not so much range of motion and angular velocity of the shock to reduce stress was important. In the further research, front landing as well as various direction of motion of kinetic, kinetic factors and EMG variables on lower limbs joints of the study in terms of injury-prevention-approach is going to be needed.