• 제목/요약/키워드: 2-Dimensional

Search Result 15,203, Processing Time 0.044 seconds

APPLICATION OF FINITE ELEMENT ANALYSIS TO EVALUATE IMPLANT FRACTURES

  • Kim Yang-Soo;Kim Chang-Whe;Lim Young-Jun;Kim Myung-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.3
    • /
    • pp.295-313
    • /
    • 2006
  • Statement of problem. Higher fracture rates were reported for Branemark implants placed in the maxilla and for 3.75 mm diameter implants installed in the posterior region. Purpose. The purpose of this study was to investigate the fracture of a fixture by finite element analysis and to compare different diameter of fixtures according to the level of alveolar bone resorption. Material and Methods. The single implant and prosthesis was modeled in accordance with the geometric designs for the 3i implant systems. Models were processed by the software programs HyperMesh and ANSA. Three-dimensional finite element models were developed for; (1) a regular titanium implant 3.75 mm in diameter and 13 mm in length (2) a regular titanium implant 4.0 mm in diameter and 13 mm in length (3) a wide titanium implant 5.0 mm in diameter and 13 mm in length each with a cementation type abutment and titanium alloy screw. The abutment screws were subjected to a tightening torque of 30 Ncm. The amount of preload was hypothesized as 650 N, and round and flat type prostheses were 12 mm in diameter, 9 mm in height were loaded to 600 N. Four loading offset points (0, 2, 4, and 6 mm from the center of the implants) were evaluated. To evaluate fixture fracture by alveolar bone resorption, we investigated the stress distribution of the fixtures according to different alveola. bone loss levels (0, 1.5, 3.5, and 5.0 mm of alveolar bone loss). Using these 12 models (four degrees of bone loss and three implant diameters), the effects of load-ing offset, the effect of alveolar bone resorption and the size of fixtures were evaluated. The PAM-CRASH 2G simulation software was used for analysis of stress. The PAM-VIEW and HyperView programs were used for post processing. Results. The results from our experiment are as follows: 1. Preload maintains implant-abutment joint stability within a limited offset point against occlusal force. 2. Von Mises stress of the implant, abutment screw, abutment, and bone was decreased with in-creasing of the implant diameter. 3. With severe advancing of alveolar bone resorption, fracture of the 3.75 and the 4.0 mm diameter implant was possible. 4. With increasing of bending stress by loading offset, fracture of the abutment screw was possible.

Shipboard Active Phased Array Antenna System for Satellite Communications (위성 통신용 선박 탑재 능동 위상배열 안테나 시스템)

  • 전순익;채종석;오승엽
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.10
    • /
    • pp.1089-1097
    • /
    • 2002
  • In this paper, the novel shipboard Active Phased Array Antenna(APAA) system for maritime mobile satellite communications is introduced. The antenna uses novel technologies like wide range hybrid tracking, single antenna elements with both of Rx and Tx, asymmetrical array structure, interference isolation between Rx and Tx, and error correction method from frequency scan effect. The antenna has single aperture for both of Rx and Tx with 32 $\times$ 4 two-dimensional array. The antenna has two beams. Its frequencies are 7.25 ~ 7.75 GHz for Rx and 7.9 ~ 8.4 GHz for Tx. The antenna gains are 35.4 dBi for Rx and 35.7 dBi for Tx, those are 54 % of efficiency. The electrically steering ranges are $\pm$35$^{\circ}$ of elevation direction and $\pm$4$^{\circ}$ of azimuth direction. The mechanical control ranges at hybrid tracking capability are continuous 360$^{\circ}$ of azimuth direction and $\pm$10$^{\circ}$ of elevation direction. The antenna has 2.2$^{\circ}$ of 3 dB beamwidth, -14 dB of sidelobe level, and 21 dB of cross-pol suppression. The antenna performance was measured by near field measurement set. Its system performance was tested on the ship motion simulator and with the satellite transponder simulator. The test result showed that its tracking error was within -3 dB from its peak gain under motion condition. The antenna system was tested by real modulated Direct Broadcasting Satellite(DBS) signals to check its communication processing function.

A Study of the Local Scour Considering the Pier Shapes in the Cohesive Bed (점착성 하상에서의 교각형상에 따른 국부세굴 연구)

  • Choe, Gye-Un;Kim, Gi-Hyeong
    • Journal of Korea Water Resources Association
    • /
    • v.31 no.5
    • /
    • pp.539-552
    • /
    • 1998
  • When the pier is constructed in the cohesive be, the accuracy maynot be obtained because the equation for calculating the scour at piers is based upon the results which are analyzed through the experiments in the non-cohesive bed. In this paper, the variation of the depth of the pier scour occurred by constructing 5 types of pier in the channel having the cohesive material is examined. The experimental results are analyzed based upon Froude numbers and non-dimensional numbers which are indicated as the flow depths compared to the pier width. The results are also compared with the results obtained using the existing pier scour equations. In this paper, the shape factors, which can be used for calculating the scour depth of the pier in the cohesive channel bed, are suggested. The shape factors are indicated through the ratios between the scour depth at the circular pier and the scour depths at the different types of pier, and are suggested as two stages. In the first stage, in which the water depth compared to the pier width is less than 1.2, the shape factors are given as the equations. However, in the second stage the shape factors are given as the constant values. It is understood that the shape factors suggested in this paper can be properly usd for calculating local scour at piers in the bridges which are constructed in the cohesive channel bed having the characteristics of the bed material which is used in these experiments. Keywords : local scour, maximum scour depth, cohesive bed material, pier shape, pier, shape factor.

  • PDF

Unsteady 2-D flow field characteristics for perforated plates with a splitter

  • Yaragal, Subhash C.
    • Wind and Structures
    • /
    • v.7 no.5
    • /
    • pp.317-332
    • /
    • 2004
  • Wind tunnel experiments were conducted under highly turbulent and disturbed flow conditions over a solid/perforated plate with a long splitter plate in its plane of symmetry. The effect of varied level of perforation of the normal plate on fluctuating velocities and fluctuating pressures measured across and along the separation bubble was studied. The different perforation levels of the normal plate; that is 0%, 10%, 20%, 30%, 40% and 50% are studied. The Reynolds number based on step height was varied from $4{\times}10^3$ to $1.2{\times}10^4$. The shape and size of the bubble vary with different perforation level of the normal plate that is to say the bubble is reduced both in height and length up to 30% perforation level. For higher perforation of the normal plate, bubble is completely swept out. The peak turbulence value occurs around 0.7 to 0.8 times the reattachment length. The turbulence intensity values are highest for the case of solid normal plate (bleed air is absent) and are lowest for the case of 50% perforation of the normal plate (bleed air is maximum in the present study). From the analysis of data it is observed that $\sqrt{\overline{u^{{\prime}2}}}/(\sqrt{\overline{u^{{\prime}2}}})_{max}$, (the ratio of RMS velocity fluctuation to maximum RMS velocity fluctuation), is uniquely related with dimensionless distance y/Y', (the ratio of distance normal to splitter plate to the distance where RMS velocity fluctuation is half its maximum value) for all the perforated normal plates. It is interesting to note that for 50% perforation of the normal plate, the RMS pressure fluctuation in the flow field gets reduced to around 60% as compared to that for solid normal plate. Analysis of the results show that the ratio [$C^{\prime}_p$ max/$-C_{pb}(1-{\eta})$], where $C^{\prime}_p$ max is the maximum coefficient of fluctuating pressure, $C_{pb}$ is the coefficient of base pressure and ${\eta}$ is the perforation level (ratio of open to total area), for surface RMS pressure fluctuation levels seems to be constant and has value of about 0.22. Similar analysis show that the ratio $[C^{\prime}_p$ max/$-C_{pb}(1-{\eta})]$ for flow field RMS pressure fluctuation levels seems to be constant and has a value of about 0.32.

Color Filter Based on a Sub-Wavelength Patterned Poly-Silicon Grating Fabricated using Laser Interference Lithography (광파장 이하의 주기를 갖는 다결정 실리콘 격자 기반의 컬러필터)

  • Yoon, Yeo-Taek;Lee, Hong-Shik;Lee, Sang-Shin;Kim, Sang-Hoon;Park, Joo-Do;Lee, Ki-Dong
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.1
    • /
    • pp.20-24
    • /
    • 2008
  • A color filter was proposed and demonstrated by incorporating a subwavelength patterned 1-dimensional grating in poly silicon. It was produced by employing the laser interference lithography method, providing much wider effective area compared to the conventional e-beam lithography. A $SiO_2$ layer was introduced on top of the silicon grating layer as a mask for the etching of the silicon, facilitating the etching of the silicon layer. It was theoretically found that the selectivity of the filter was also improved thanks to the oxide layer. The parameters for the designed device include the grating pitch of 450 nm, the grating height of 100 nm and the oxide-layer height of 200 nm. As for the fabricated filter, the spectral pass band corresponded to the blue color centered at 470 nm and the peak transmission was about 40%. Within the effective area of $3{\times}3mm^2$, the variation in the relative transmission efficiency and in the center wavelength was less than 10% and 2 nm respectively. Finally, the influence of the angle of the incident beam upon the transfer characteristics of the device was investigated in terms of the rate of the relative transmission efficiency, which was found to be equivalent to 1.5%/degree.

A Kinematic Analysis of the Defence Types during Body Lock Technique in the Ground Wrestling (그라운드 레슬링 가로들기 공격 시 수비 유형의 운동학적 분석)

  • Hah, Chong-Ku;Ryu, Ji-Seon
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.1
    • /
    • pp.155-164
    • /
    • 2007
  • This study is to find out effective defensive type by analysis on differences among three different defence types of the body lock technique in the ground wrestling. The subjects are 5 athletes who are in 60kg weight class. To get the kinematic analysis seven ProReflex MCU-240(Motion Capture Unit), infrared rays cameras, which was produced by Qualisys, were used to get a two-dimensional coordinate. Following are the analysis result from kinematic factors such as time element, speed element and angular element. 1. During position of ground wrestling, the average necessary time until defender's hip joint touches the mat for Phase1 was $0.34{\pm}0.14sec$ at side position was the shortest space of time out of three types, and Phase2 was $0.21{\pm}0.02sec$ at front position was the shortest space of time out of three types. Moreover, side defence position was the shortest for total average necessary time with $0.78{\pm}0.05sec$. 2. The movement change for hip joint was $57.21{\pm}20.17cm$ for front, $43.35{\pm}7.13cm$ for rear, and $18.67{\pm}10.24cm$ for side at Phase1 and $42.08{\pm}17.56cm$ for side, $16.61{\pm}6.34cm$ for front, and $1.48{\pm}1.29cm$ for rear at Phase2. 3. Movement speed of hip joint at defensive type were most effective in success and fail rate at Phase 1 and its frontal average speed was fastest with $1.01{\pm}0.23m/s$ following by $0.52{\pm}0.15m/s$ for side, and $0.62{\pm}0.15m/s$ for rear. The average for total change of speed is $0.79{\pm}0.32m/s$ for front, $0.78{\pm}0.17m/s$ for side, and $0.49{\pm}0.08m/s$ for rear. 4. The joint angle gets smaller in a order by rear, front, and side for the size of hip joint angle and knee angle for different defensive type. 5. As a result of one-way ANOVA on linear velocity for hip joint in frontal defence(phase1) was significance ($\alpha$=.05), but phase 2 was not significance. Synthetically, analyzing on differences among three different defence types which were front, rear, and side of the body lock technique in the ground wrestling, front defensive type was the most effective. In future, there should be more studies regarding on defence at not a laboratory study but a field study to help out wrestler to pertinent techniques to improve the game of wrestling.

Phosphorylated Proteins of Mitogen Stimulated-Rat Peripheral Blood Lymphocytes (분열유발인자에 의한 흰쥐 림프구 단백의 인산화)

  • Jou, I-Lo;Ko, Sung-Soo;Ahn, Young-Soo
    • The Korean Journal of Pharmacology
    • /
    • v.29 no.1
    • /
    • pp.121-130
    • /
    • 1993
  • This study was done to classify the proteins involved in the specific phosphorylation using the rat peripheral blood lymphocytes (rPBL) stimulated with mitogens, phorbol 12-myristate 13-acetate (PMA) and concanavalin A (Con A). The lymphocytes were incubated with $^{32}P-orthophosphate$ before PMA or Con A stimulation. The migration patterns of the phosphorylated proteins of mitogen-treated rPBL in two dimensional electrophoretic fields were analyzed after autoradiography. The stimulation of the lymphocytes with PMA and Con A increased the phosphorylation of thirteen protein fractions. The phosphorylation intensities of the protein spots differ to the treatments of the cells with specific kinase inhibitors, H-7 and W-7. These protein fractions were grouped into 3 classes, namely, PKC-mediated, CaM kinase-mediated, and other kinase mediated proteins. The effect of the duration of the stimulation on the phosphorylated behaviors occurred concurrently, not sequentially, although each individual protein fraction had a different time for the peak phosphorylation during the stimulation period upto 30 minutes. The phosphoproteins found in the cytosolic soluble fraction were phosphorylated prior to those in the pellet, whose phosphorylations were sustained at a high level for over 10 minutes. The above results suggest that the early events in lymphocyte activation involve 3 different sets of proteins which are phosphorylated by CaM kinase, PKC and other kinases, and those kinases do not work sequentially, but rather, independently or cooperatively.

  • PDF

Wet Etching Characteristics of Cu Surface for Cu-Cu Pattern Direct Bonds (Cu-Cu 패턴 직접접합을 위한 습식 용액에 따른 Cu 표면 식각 특성 평가)

  • Park, Jong-Myeong;Kim, Yeong-Rae;Kim, Sung-Dong;Kim, Jae-Won;Park, Young-Bae
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.19 no.1
    • /
    • pp.39-45
    • /
    • 2012
  • Three-dimensional integrated circuit(3D IC) technology has become increasingly important due to the demand for high system performance and functionality. In this work, BOE and HF wet etching of Cu line surfaces after CMP were conducted for Cu-Cu pattern direct bonding. Step height of Cu and $SiO_2$ as well as Cu dishing after Cu CMP were analyzed by the 3D-Profiler. Step height increased and Cu dishing decreased with increasing BOE and HF wet etching times. XPS analysis of Cu surface revealed that Cu surface oxide layer was partially removed by BOE and HF wet etching treatment. BOE treatment showed not only the effective $SiO_2$ etching but also reduced dishing and Cu surface oxide rather than HF treatment, which can be used as an meaningful process data for reliable Cu-Cu pattern bonding characteristics.

The Analysis of Japanese Public Libraries' Characteristics by Types: Focused on the Consideration of Liaison Between Service Contents and Service Space (일본 공립도서관의 유형별 특성 분석 - 서비스내용과 서비스공간의 연계적 고찰을 중심으로 -)

  • Jung, A-Young
    • Journal of the Korean BIBLIA Society for library and Information Science
    • /
    • v.23 no.2
    • /
    • pp.171-185
    • /
    • 2012
  • This study takes note on the need for the consideration of the relationship between the service contents and service space which libraries provide, since at the moment the demands of library users, purpose of using it, etc. gradually become varied. In this study, type classification of public libraries was done focused on the relationship between service contents and service space, targeting Japanese public libraries. Through linking approach between service contents and service space, the analysis of Japanese public libraries' characteristics and type characteristics could be captured. This study has ultimately aimed to prepare for the basic data which will help Korean public libraries to make connection between service contents and service space in the future. The collected service contents and service space had been analyzed by multi-dimensional data analysis methods such as the "Quantification Theory Analysis Type III" and "Cluster Analysis". After characters of libraries were analyzed, the findings of this study show the views such as "the field of information provided, the method of information provision, and the object of service provision." And types of 44 libraries are classified into those which have 6 kinds of characteristics as follows : (1) group-oriented libraries which provide the jobs and employment information, (2) libraries which provide the jobs and employment information through the counselling space, (3) individual-oriented libraries which provide the information of education-related fields, (4) group-oriented libraries which provide the information of education-related fields, (5) libraries which provide information focusing on the counselling space, (6) individual-oriented libraries which focused on the service provision.

Effect of Partial Prestressing Ratio and Effective Prestress on the Flexural Behavior of Prestressed Lightweight Concrete Beams (프리스트레스트 경량 콘크리트 보의 휨 거동에 대한 부분 프리스트레싱비와 유효 프리스트레스의 영향)

  • Yang, Keun-Hyeok;Moon, Ju-Hyun;Byun, Hang-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.1
    • /
    • pp.39-48
    • /
    • 2011
  • The present investigation evaluates the flexural behavior of pre-tensioned lightweight concrete beams under two-point symmetrical concentrated loads according to the variation of the partial prestressing ratio and the effective prestress of prestressing strands. The designed compressive strength of the lightweight concrete with a dry density of 1,770 $kg/m^3$ was 35 MPa. The deformed bar with a yield strength of 383 MPa and three-wire mono-strands with tensile strength of 2,040 MPa were used for longitudinal tensile reinforcement and prestressing steel reinforcement, respectively. According to the test results, the flexural capacity of pre-tensioned lightweight concrete beams increased with the increase of the partial prestressing ratio and was marginally influenced by the effective prestress of strands. With the same reinforcing index, the normalized flexural capacity of pre-tensioned lightweight concrete beams was similar to that of pre-tensioned normal-weight concrete beams tested by Harajli and Naaman and Bennett. On the other hand, the displacement ductility ratio of pre-tensioned lightweight concrete beams increased with the decrease of the partial prestressing ratio and with the increase of the effective prestress of strands. The load-displacement relationship of pre-tensioned lightweight concrete beam specimens can be suitably predicted by the developed non-linear two-dimensional analysis procedure. In addition, the flexural cracking moment and flexural capacity of pre-tensioned lightweight concrete beams can be conservatively evaluated using the elasticity theorem and the approach specified in ACI 318-08, respectively.