• Title/Summary/Keyword: 2-D correlation

Search Result 2,731, Processing Time 0.029 seconds

Correlation over Nonlinear Analysis of EEG and TCI Factor (상관차원에 의한 비선형 뇌파 분석과 기질성격척도(TCI) 요인간의 상관분석)

  • Park, Jin-Sung;Park, Young-Bae;Park, Young-Jae;Huh, Young
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.11 no.2
    • /
    • pp.96-115
    • /
    • 2007
  • Background and Purpose: Electroencephalogram(EEG) is a multi-scaled signal consisting of several components of time series with different origins. Recently, because of the absence of an identified metric which quantifies the complex amount of information, there are many limitations in using such a linear method. According to chaos theory, irregular signals of EEG can also result from low dimensional deterministic chaos. Chaotic nonlinear dynamics in the EEG can be studied by calculating the correlation dimension. The aim of this study is to analyze correlation between the correlation dimension of EEG and psychological Test (TCI). Methods: Before and after moxibustion treatment, EEG raw data were measured by moving windows during 15 minutes. The correlation dimension(D2) was calculated from stabilized 40 seconds in 15 minutes data. 8 channels EEG study on the Fp, F, T, P was carried out in 30 subjects. Results: Correlation analysis of TCI test is calculated with deterministic non-linear data and stochastic non-linear data. 1. Novelty seeking in temperament is positive correlated with D2 of EEG on Fp. 2. reward dependence in temperament is positive correlated with D2 of EEG on T3,T4 and negative correlated with D2 of EEG on P3,P4. 3. self directedness in character is positive correlated with D2 of EEG on F4, P3. 4. Harm avoidance is negative correlated with D2 of EEG on Fp2, T3, P3. Conclusion: These results suggest that nonlinear analysis of EEG can quantify dynamic state of brain abolut psychological Test (TCI).

  • PDF

2D Correlation Analysis of Spin-Coated Films of Biodegradable P(HB-co-HHx)/PEG Blends

  • Kim, Min-Kyung;Ryu, Soo-Ryeon;Noda, Isao;Jung, Young-Mee
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.11
    • /
    • pp.4005-4010
    • /
    • 2011
  • We investigated thermal behavior of spin-coated films of P(HB-co-HHx)/PEG blends by using infraredreflection absorption (IRRAS) spectroscopy and 2D correlation spectroscopy. Based on 2D IRRAS correlation spectra, we could determine the sequence of spectral intensity changes with increasing temperature that PEG band changes first and then a band for crystalline component of P(HB-co-HHx) changes before a band for amorphous component. The intensities of bands for PEG and amorphous P(HB-co-HHx) were changed greatly as PEG weigh % of P(HB-co-HHx)/PEG blends increased. Transition temperatures of P(HB-co-HHx)/PEG blends were successfully determined by 2D gradient mapping method. The transition temperature of spincoated films of 98/2 and 90/10 P(HB-co-HHx)/PEG blends and 80/20 P(HB-co-HHx)/PEG blend determined by 2D gradient map are, respectively, about 137.5 and $132.5^{\circ}C$. Furthermore, P(HB-co-HHx)/PEG blends show an additional transition temperature that have been interpreted in terms of different lamellar thicknesses in spin coated films.

ML Frame Synchronization for Gaussian Channel with Co-channel Interference (가우스 잡음과 CO-CHANNEL 간섭이 존재하는 채널에서의 최대추정 프레임 동기)

  • 문병현;우홍체;김신환;이채욱
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.18 no.5
    • /
    • pp.643-649
    • /
    • 1993
  • The problem of locating a periodically inserted frame synchronization pattern in random data for a binary pulse amplitude modulated (PAM) digital communication system over a additive white Gaussian noise(AWGN) channel with co-channel interference is considered. The performance degradation of frame synchronization for the correlation rule due to the presence of co-channel interference is shown. The maximum likelihood(ML) decision rule for the frame synchronization over an AWGN channel with co-channel interference is derived. For the entire range of SNR considered, the ML frame synchronization rule obtains about 1dB signal energy gain over the correlation rule. Specially, the ML rule obtains as much as 2dB gain over the correlation rule when the SNR is greater than 0dB.

  • PDF

Electroencephalographic Correlation Dimension Changes with Depth of Halothane

  • Lee, Maan-Gee;Park, Eun-Ju;Choi, Jung-Mee;Yoon, Moon-Han
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.3 no.5
    • /
    • pp.491-499
    • /
    • 1999
  • This study was designed to evaluate the efficacy of dynamic parameters, such as correlation dimension $D_2,$ by comparing spectral electroencephalographic (EEG) parameters. These parameters are used to estimate the depth of halothane anesthesia as defined by the presence of body movement in response to a tail clamp. Six rats were used and each of them was exposed to halothane sequentially at the concentrations of 0%, 0.5%, 1.0% and 1.5% for 30 min. A tail clamp was applied every five min and the movements were recorded at each concentration level. The spectral parameters and the dynamic parameters were derived from 20-sec and 10-sec segments, respectively, from the last 5-mins of EEG recording at each concentration level. Correlation coefficients between the parameters and the movements were calculated. Standardized values of three parameters, betaL power, median power frequency (MPF), and $D_2$ were derived by calculation based on the number of animals showing the movement in response to a tail clamp. The betaL power had the largest correlation coefficient to spontaneous movement and to the response to a tail clamp than any other band parameter. MPF had a better correlation with the movement than 90% spectral edge frequency. Among the dynamic parameters, $D_2$ on the parietal cortex had a better correlation with the movement. The level of deviation and variation of standardized $D_2,$ MPF, and betaL were significant (p<0.01). The order of deviation and variation was; betaL power > MPF > $D_2.$ The correlation dimension serves as a better index for the depth of halothane anesthesia defined in forms of a response to external stimulation.

  • PDF

Improved generalized cross correlation-phase transform based time delay estimation by frequency domain autocorrelation (주파수영역 자기상관에 의한 위상 변환 일반 상호 상관 시간 지연 추정기 성능 개선)

  • Lim, Jun-Seok;Cheong, MyoungJun;Kim, Seongil
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.5
    • /
    • pp.271-275
    • /
    • 2018
  • There are several methods for estimating the time delay between incoming signals to two sensors. Among them, the GCC-PHAT (Generalized Cross Correlation-Phase Transform) method, which estimates the relative delay from the signal whitening and the cross-correlation between the different signal inputs to the two sensors, is a traditionally well known method for achieving stable performance. In this paper, we have identified a part of GCC-PHAT that can improve the periodicity. Also, we apply the auto-correlation method that is widely used as a method to improve the periodicity. Comparing the proposed method with the GCC-PHAT method, we show that the proposed method improves the mean square error performance by 5 dB ~ 15 dB at the SNR above 0 dB for white Gaussian signal source and also show that the method improves the mean square error performance up to 15 dB at the SNR above 2 dB for the color signal source.

Analysis of cross-correlation functions of non-linear sequences (비선형수열의 상호상관함수 분석)

  • Cho, Sung-Jin;Yim, Ji-Mi
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.5
    • /
    • pp.1138-1144
    • /
    • 2013
  • Cross-correlation functions of maximal period sequences have been studied for decades. In this paper, we find the cross-correlation values of non-linear sequences $S_a^r(t)=Tr_1^m\{[Tr_m^n(a{\alpha}^t+{\alpha}^{dt})]^r\}$ having the maximal period $2^n-1$ for Niho type decimation $d=2^{m-2}(2^m+3)$, where n=2m. In particular, we call d Niho type decimation in case $d{\equiv}1(mod\;2^m-1)$. And we analyze the cross-correlation distributions of $S_a^r(t)$ when the phase shift ${\tau}=(2^m+1)k(0{\leq}k{\leq}2^m-2)$ and provide experiment results.

Generalized Two-dimensional (2D) Correlation Spectroscopy: Principle and Its Applications (일반화된 이차원 상관 분광학: 원리 및 응용)

  • Young Mee Jung;Seung Bin Kim
    • Journal of the Korean Chemical Society
    • /
    • v.47 no.5
    • /
    • pp.447-459
    • /
    • 2003
  • Generalized 2D correlation spectroscopy has been applied extensively to the analysis of spectral data sets obtained during the observation of a system under some external perturbation. It is used in various fields of spectroscopy including IR, Raman, UV, fluorescence, X-ray diffraction, and X-ray absorption spectroscopy (XAS) as well as chromatography. 2D hetero-spectral correlation analysis compares two completely different types of spectra obtained for a system under the same perturbation. Because of the wide range of applications of this technique, it has become one of the standard analytical techniques for the analytical chemistry, physical chemistry, biochemistry, and so on, and for studies of polymers, biomolecules, nanomaterials, etc. In this paper, we will introduce the principle of generalized 2D correlation spectroscopy and its applications that we have studied.

Depth Extraction of Integral Imaging Using Correlation (상관관계를 활용한 집적 영상의 깊이 추출 방법)

  • Kim, Youngjun;Cho, Ki-Ok;Kim, Cheolsu;Cho, Myungjin
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.7
    • /
    • pp.1369-1375
    • /
    • 2016
  • In this paper, we present a depth extraction method of integral imaging using correlation between elemental images with phase only filter. Integral imaging is a passive three-dimensional (3D) imaging system records ray information of 3D objects through lenslet array by 2D image sensor, and displays 3D images by using the similar lenslet array. 2D images by lenslet array have different perspectives. These images are referred to as elemental images. Since the correlation can be calculated between elemental images, the depth information of 3D objects can be extracted. To obtain high correaltion between elemental images effectively, in this paper, we use phase only filter. Using this high correlation, the corresponding pixels between elemental images can be found so that depth information can be extracted by computational reconstruction technique. In this paper, to prove our method, we carry out optical experiment and calculate Peak Sidelobe Ratio (PSR) as a correlation metric.

The Study of Correlation between HNR and NNE (HNR과 NNE와의 상관관계 연구)

  • Kim, Kyung-Yuel;Shin, Myung-Sun;An, Jong-Bok;Jeong, Ok-Ran
    • Speech Sciences
    • /
    • v.8 no.3
    • /
    • pp.235-241
    • /
    • 2001
  • The purpose of this study was to determine the correlation between HNR and NNE, EGG HNR and EGG NNE, which are most closely related to noise of voice. Dr. Speech was utilized to obtain acoustic measurements and physiologic measurements, simultaneously. In addition, no normative data of HNR, NNE, EGG HNR, EGG NNE are available in Korean subjects at present. The Pearson correlation coefficient was used to find the correlation between HNR and NNE, EGG HNR and EGG NNE. The results of the study were as follows: First, there was no correlation between HNR and NNE. Second, there was a negative correlation between EGG HNR and EGG NNE. Finally, the mean value of HNR of normal Korean adults was $28.8\pm2.7$ dB, that of NNE -$11.7\pm3.9$ dB, that of EGG HNR $32.9\pm4.6$ dB, and that of EGG NNE $-30.3\pm4.6$ dB.

  • PDF