• Title/Summary/Keyword: 2-D analytical method

Search Result 486, Processing Time 0.023 seconds

CURVED BOUNDARY TREATMENT OF THE LATTICE BOLTZMANN METHOD FOR SLIP FLOW SIMULATIONS (Slip flow 해석을 위한 격자볼츠만 방법의 곡면처리기법)

  • Jeong, Namgyun
    • Journal of computational fluids engineering
    • /
    • v.19 no.3
    • /
    • pp.77-84
    • /
    • 2014
  • The lattice Boltzmann (LB) method has been used to simulate rarefied gas flows in a micro-system as an alternative tool. However, previous results were mainly focused on a simple geometry with flat walls because the LB method is modeled on uniform Cartesian lattices. When previous boundary conditions for the microflows are applied to curved walls, the use of them requires approximation of the curved boundary by a series of stair steps, and introduces additional errors. For macroflows, no-slip curved wall boundary treatments have been developed remarkably in order to overcome these limits. However, the investigations for the slip curved wall boundary have rarely been performed for microflows. In this work, a curved boundary treatment of the LB method for a slip flow has been introduced. The results of the LB method for 2D microchannel and 3D microtube flows are in excellent agreement with the analytical solutions.

Fundamental Investigation of Non-invasive Determination of Glucose by Near Infrared Spectrophotometry (근적외선 분광법을 이용한 비침투적 혈당 분석법 개발에 관한 기초 연구)

  • Kim, Hyo J.;Woo, Young A.;Chang, Soo H.;Cho, Chang H.;Cantrell, Kevin;Piepmeier, Edward H.
    • Analytical Science and Technology
    • /
    • v.11 no.1
    • /
    • pp.47-53
    • /
    • 1998
  • This study is to improve the diagnosis of diabetes mellitus and the self-monitoring of blood glucose in people with diabetes by providing a non-invasive method of monitoring blood glucose. A near-infrared (NIR) spectrophotometer was used to measure absorption spectra of 80 glucose samples ranges from 1 mg/dL to 200 mg/dL, and shows the standard error of prediction 1.8 mg/dL. Also, to investigate the effect of interference in blood, NaCl and sand were added in glucose and found the standard error of prediction of 2.8 mg/dL and 3.8 mg/dL, respectively. A new and more accurate calibration system for the spectrophotometer was developed from systematic study of light scattering, which cause nonlinear spectrophotometer response.

  • PDF

A Study on the Structural Analysis of Curved Portions of Pipe Loops Used in Ships (선박용 파이프 루프 곡선부의 구조해석에 관한 연구)

  • Park, Chi-Mo;Bae, Byoung-Il
    • Journal of Ocean Engineering and Technology
    • /
    • v.24 no.5
    • /
    • pp.88-93
    • /
    • 2010
  • Many pipes that are arranged longitudinally in ships have loops at intervals to prevent the failure of the pipes as they absorb large portions of the axial load caused by the bending of the hull girder and/or thermal loads when the pipes are carrying very hot fluids. Since the loops are curved at corners, an efficient method for conducting the structural analyses of these curved portions is required. In this paper, a pipe loop was analyzed by an analytical method and by the finite-element method in four different ways, i.e., based on straight-beam elements, curved-beam elements, 2-D shell elements, and 3-D solid elements. The results of the five analyses were compared to check the validity of the current curved-beam theory. The paper includes some suggestions on how to analyze the pipe loops efficiently.

Novel quasi 3D theory for mechanical responses of FG-CNTs reinforced composite nanoplates

  • Alazwari, Mashhour A.;Daikh, Ahmed Amine;Eltaher, Mohamed A.
    • Advances in nano research
    • /
    • v.12 no.2
    • /
    • pp.117-137
    • /
    • 2022
  • Effect of thickness stretching on free vibration, bending and buckling behavior of carbon nanotubes reinforced composite (CNTRC) laminated nanoplates rested on new variable elastic foundation is investigated in this paper using a developed four-unknown quasi-3D higher-order shear deformation theory (HSDT). The key feature of this theoretical formulation is that, in addition to considering the thickness stretching effect, the number of unknowns of the displacement field is reduced to four, and which is more than five in the other models. Two new forms of CNTs reinforcement distribution are proposed and analyzed based on cosine functions. By considering the higher-order nonlocal strain gradient theory, microstructure and length scale influences are included. Variational method is developed to derive the governing equation and Galerkin method is employed to derive an analytical solution of governing equilibrium equations. Two-dimensional variable Winkler elastic foundation is suggested in this study for the first time. A parametric study is executed to determine the impact of the reinforcement patterns, nonlocal parameter, length scale parameter, side-t-thickness ratio and aspect ratio, elastic foundation and various boundary conditions on bending, buckling and free vibration responses of the CNTRC plate.

Application and Validation of an Optimal Analytical Method using QuEChERS for the determination of Tolpyralate in Agricultural Products (QuEChERS법을 활용한 농산물 중 제초제 Tolpyralate의 최적 분석법 선발 및 검증)

  • Lee, Han Sol;Park, Ji-Su;Lee, Su Jung;Shin, Hye-Sun;Kim, Ji-Young;Yun, Sang Soon;Jung, Yong-hyun;Oh, Jae-Ho
    • Korean Journal of Environmental Agriculture
    • /
    • v.39 no.3
    • /
    • pp.246-252
    • /
    • 2020
  • BACKGROUND: Pesticides are broadly used to control weeds and pests, and the residues remaining in crops are managed in accordance with the MRLs (maximum residue limits). Therefore, an analytical method is required to quantify the residues, and we conducted a series of analyses to select and validate the quick and simple analytical method for tolpyralate in five agricultural products using QuEChERS (quick, easy, cheap, effective, rugged and safe) method and LC-MS/MS (liquid chromatography-tandem mass spectrometry). METHODS AND RESULTS: The agricultural samples were extracted with acetonitrile followed by addition of anhydrous magnesium sulfate, sodium chloride, disodium hydrogencitrate sesquihydrate and trisodium citrate dihydrate. After shaking and centrifugation, purification was performed with d-SPE (dispersive-solid phase extraction) sorbents. To validate the optimized method, its selectivity, linearity, LOD (limit of detection), LOQ (limit of quantitation), accuracy, repeatability, and reproducibility from the inter-laboratory analyses were considered. LOQ of the analytical method was 0.01 mg/kg at five agricultural products and the linearity of matrix-matched calibration were good at seven concentration levels, from 0.0025 to 0.25 mg/L (R2≥0.9980). Mean recoveries at three spiking levels (n=5) were in the range of 85.2~112.4% with associated relative standard deviation values less than 6.2%, and the coefficient of variation between the two laboratories was also below 13%. All optimized results were validated according to the criteria ranges requested in the Codex Alimentarius Commission (CAC) and Ministry of Food and Drug Safety (MFDS) guidelines. CONCLUSION: In conclusion, we suggest that the selected and validated method could serve as a basic data for detecting tolpyralate residue in imported and domestic agricultural products.

STEADY-STATE TEMPERATURE ANALYSIS TO 2D ELASTICITY AND THERMO-ELASTICITY PROBLEMS FOR INHOMOGENEOUS SOLIDS IN HALF-PLANE

  • GHADLE, KIRTIWANT P.;ADHE, ABHIJEET B.
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.24 no.1
    • /
    • pp.93-102
    • /
    • 2020
  • The concept of temperature distribution in inhomogeneous semi-infinite solids is examined by making use of direct integration method. The analysis is done on the solution of the in-plane steady state heat conduction problem under certain boundary conditions. The method of direct integration has been employed, which is then reduced to Volterra integral equation of second kind, produces the explicit form analytical solution. Using resolvent- kernel algorithm, the governing equation is solved to get present solution. The temperature distribution obtained and calculated numerically and the relation with distribution of heat flux generated by internal heat source is shown graphically.

Load Transfer Mechanism between Rafter and Cross-beam by 2-D Analysis (이차원해석에 의한 서까래 도리 사이의 하중전달 메카니즘)

  • Jung, Sung-Jin;Hong, Sung-Gul;Kim, Nam-Hee;Lee, Young-Wook;Hwang, Jong-Kook;Joo, Seok-Jun
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2007.04a
    • /
    • pp.229-234
    • /
    • 2007
  • In the structural analysis of the Korean traditional wooden structure, while the understanding of the transfer mechanism of roof load is very important, there are few researches on this subject. So, some modeling methods considering the connecting methods of the Korean traditional wooden structure are suggested, the results using each modeling method are compared, and the most reasonable analytical model is presented in this study.

  • PDF

Pretreatment of Fish for the determination of polycyclic aromatic hydrocarbons using alkali digestion (알칼리분해를 이용한 어류 중 다환방향족탄화수소의 전처리방법)

  • Hu, Soojung;Lee, Hyomin;Chae, Youngzoo;Yoo, Eun-Ah
    • Analytical Science and Technology
    • /
    • v.18 no.5
    • /
    • pp.403-409
    • /
    • 2005
  • Polycyclic Aromatic Hydrocarbons(PAHs) contamination arises from several sources including processing of food(smoking, direct drying, cooking) and environmental contamination of air, water, or soil, the later being considered as the most important. In this study, to establish the analytical method for some PAHs[benzo(a)anthracene, chrysene, benzo(b)fluoranthene, benzo(k)fluoranthene, benzo(a)pyrene, dibenzo(a,h)anthracene, benzo(g,h,i)perylene, indeno(1,2,3-c,d)pyrene] in fish, alkali digestion time, extraction solvents, elution volume of florisil cartridge for clean-up have been optimized. The methodology involved saponification and extraction with n-hexane, clean-up on Sep-Pak florisil cartridges and determination by HPLC/FLD(High Performance Liquid Chromatography/Fluorescence Detector). Overall method recoveries for 8 PAHs spiked into these products ranged from 90 to 106%.

Three-Dimensional Performance Analysis of a Thermally Asymmetric Rectangular Fin

  • Kang, Hyung-Suk
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.9 no.2
    • /
    • pp.94-101
    • /
    • 2001
  • Fin effectiveness and efficiency of a thermally asymmetric rectangular fin are represented as a function of non-dimensional fin length, width, fip tip surface Biot number and the ratio of fin bottom surface Biot number to top surface Biot number. For this analysis, three dimensional separation of variables method is used. One of the results shows that fin effectiveness can be increased or decreased depending on the fin length as the fin tip surface Biot number increases while fin efficiency decreases without depending on that as the fin tip surface Biot number increases.

  • PDF

Simultaneous Determination of C22-C26 Very Long - Chain Fatty Acids Following tert-Butyldimethylsilyl Derivatization by Stable Isotope GC- MS for the Screening of Adrenoleucodystrophy

  • Yoon, Hye-Ran
    • Biomolecules & Therapeutics
    • /
    • v.15 no.4
    • /
    • pp.266-272
    • /
    • 2007
  • A rapid analytical method was developed to quantify very long-chain fatty acids (VLCFAs, C22:0, C24:0, C26:0) in human plasma with good sensitivity and specificity using tert-butyldimethylsilyl (TBDMS) derivatization and stable isotope GC-MS selective ion monitoring (GC-MS/SIM). Two-hundred and fifty ${\mu}L$ of plasma was fortified with deuterated stable isotope internal standards (d3-C22:0, d3-C24:0, d3-C26:0) and standard mixtures of chloroform and methanol, and then extracted with hexane and acetonitrile. To upper layer of liquid-liquid-extraction, N-(t-Butyldimethylsilyl)-N-methyltrifluoroacetamide was added and then heated to $60^{\circ}C$ for 30 min to produce the TBDMS derivatives. Derivatives of VLCFAs were analyzed by GC-MS/SIM. Calibration curves showed a linear relationship for the target compounds in the concentration range of $10^{-4}{\sim}2{\times}10^3\;{\mu}g/mL$ with the correlation coefficient ranging from 0.996 to 0.999. The limit of quantification for the plasma was $10^{-4}{\sim}2{\times}10^{-4}\;{\mu}g/mL$ (S/N=3). When applied to the plasma specimens of patients with peroxisomal disorder, X-linked adrenoleucodystropy (ALD, Mckusick 202370), the method clearly differentiated normal subjects from ALD patients. The C24:0/C22:0 and C26:0/C22:0 ratios were significantly elevated in the plasma of patients with X-linked ALD compared to normal subjects. The new developed method might be useful for a rapid and sensitive diagnosis of X-linked ALD and other peroxisomal disorders.