• 제목/요약/키워드: 2 phase pulse

검색결과 465건 처리시간 0.027초

Atomic Layer Epitaxy 법에 의한 TiN 박막의 성장과 그 특성 (Growth and Characteristics of TiN Thin Films by Atomic Layer Epitaxy)

  • 이종화;김동진
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1998년도 추계종합학술대회 논문집
    • /
    • pp.581-584
    • /
    • 1998
  • TiN thin films were grown on (100) Si substrate by atomic layer epitaxy at 130 - $240^{\circ}C$ using TEMAT and NH3 as precursors. Reactants were injected into the reactor in sequence of TEMAT precursor vapor pulse, N2 purging gas pulse, NH3 gas pulse and N2 purging gas pulse so that gas-phase reactions could be removed. The films were characterized by means of x-ray diffraction(XRD), 4-point probe, atomic force microscopy(AFM) and auger electron spectroscopy(AES).

  • PDF

Polycystic Ovary Syndrome(PCOS) 환자의 맥 분석 연구 (A Study on Pulse Diagnosis in Women with Polycystic Ovary Syndrome (PCOS))

  • 박경덕;배주은;윤영진
    • 대한한방부인과학회지
    • /
    • 제30권4호
    • /
    • pp.77-88
    • /
    • 2017
  • Objectives: The purpose of this study is to analyze the characteristics of the pulse energy in women with PCOS (Polycystic ovary syndrome) compared with women who have a regular menstrual cycle. Methods: We analyzed the values of pulse energy on 20 patients with PCOS as an experimental group and 40 patients with regular menstrual cycle as a control group. Control group was divided into 20 women with follicular phase and 20 women with luteal phase respectively. Statistical analysis was performed using SPSS/Win 18.0, one way ANOVA and Tukey HSD. Results: The results were as follows. 1. The mean pulse energy of the Right Chon was significantly increased compared with those of the Left Kwan and the Right Kwan among PCOS group. 2. There were no statistically significant pulse energy among control groups. Conclusions: The pulse energy of Lung is bigger than that of Spleen and Liver in PCOS patients compared with women who have a regular menstrual cycle.

연소가스내 탈황탈질처리를 위한 저온 플라즈마 기술 (Non-Thermal Plasma Technique for Removing $SO_2$ and $NO_x$ from Combustion Flue Gas)

  • 송영훈;신완호;김석준;장길홍
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 1997년도 제15회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.69-76
    • /
    • 1997
  • Industrial-scale pulse corona process to remove $SO_2$ and $NO_x$ simultaneously from combustion flue gas has been studied. The pilot plant built in the present study treats 2,000 $Nm^3$/hr of flue gas from a boiler. The geometry of the pulse corona reactor is similar to that of an electrostatic precipitator commonly used in industry, A thyratron switch and magnetic pulse compressors, which can generate up to 130 kV of peak pulse voltage and up to 30 kW of average pulse power, have been used to produce pulsed corona. The removal efficiencies of $S0_2$ and $NO_x$ with the present process are maximum of 95 % and 85 %, respectively. Electrical power consumption to produce the pulsed corona, which has been one of the major difficulties to apply this process to industry, has been evaluated in the present study. The results showed that the power consumption can be reduced significantly by simultaneous addition of hydrocarbon injection and heterogeneous phase reactions to the process.

  • PDF

200-MW 모듈레이터의 동작 특성 및 고조파 해석 (Operation Characteristic and Harmonic Analysis of 200-MW Modulator)

  • 박성수;오종석;조무현;남궁원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1577-1579
    • /
    • 1994
  • 200-MW pulse modulators(total 11units) for the PLS linac employ the SCR phase control circuit. It controls 3-phase AC line voltage for the high-voltage DC power supply (DCPS, maximum of 25kVDC, 4.2A) which charges the pulse forming network(PFN). The PFN delivers 400kV, 500A, ESW $7.5{\mu}s$ pulse power to the 80-MW klystron amplifier tube. The SCR regulates 3-phase AC power and feeds to the high voltage transformer. Two different types of the transformer configurations namely ${\Delta}-{\Delta}$ and ${\Delta}-Y$, are alternatively installed to 11 modulator units for the suppression of harmonic noises. RC filters and reactors are also installed. Currently, approximately 110-kW of average AC power per unit is consumed at the normal operation level of the modulator with 30pps. This paper presents the operational characteristics of the high power pulse modulator, especially the experimental results of the AC line harmonic components generated by the operation of the high power pulse modulator to suppress the switching noises from the SCR and rectifying diode arrays.

  • PDF

철도차량 추진용 Linear Pulse Motor의 축소 모델 해석 및 추력 리플 저감 연구 (Study on the FEA Model of the Linear Pulse Motor for Railway Application and Reduction of Thrust Ripple)

  • 설현수;이강석;정거철;이주
    • 전기학회논문지
    • /
    • 제66권6호
    • /
    • pp.981-987
    • /
    • 2017
  • In this paper, we describe the LPM structure with a two-phase, which is not used previously, and explain its operation principle. In order to predict the accurate performance of LPM reduction model, finite element model was derived and the back EMF of LPM reduction model was measured and compared. In order to investigate the thrust and normal force of the LPM reduction model, a driving circuit capable of applying two-phase pulse currents was constructed and the performance was predicted in conjunction with the finite element analysis model. Finally, the design considering actual LPM size was performed. Since the size of the reduction model is small, the field could be made of a permanent magnet. However, it is almost impossible to manufacture a permanent magnet to match the size and capacity of a real LPM for a vehicle, in terms of cost and writing. Therefore, the actual vehicle LPM was replaced by wound type that generates a magnetic field by applying current to the field winding, and the final model was derived using the reaction surface method.

2상 인버터를 위한 공간 전압벡터 방식 (Space Voltage Vector Pulse Width Modulation for 2-Phase Inverter)

  • 장도현;박재권
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 전력전자학술대회 논문집
    • /
    • pp.280-286
    • /
    • 1998
  • In this paper, space voltage vector pulsewidth modulation for 2-phase inverter is proposed. When this method is appled to 2-phase induction motor, the phase difference of voltage between phase A and B is fixed at $90^{\circ}$and amplitude of voltage of phase Ais same with that of phase B. This method have advantages over low-power servo system because this is simple method comparing to 3-phase space vector method which requires d-q transform.

  • PDF

2상 8극 HB형 리니어펄스모터의 제어회로구성을 위한 기초연구 (A Basic Study for the Control Circuit of 2-phase 8-pole HB type Linear Pulse Motor)

  • 김성헌;김일중;이은웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.135-137
    • /
    • 1994
  • In this paper, step response, speed, maximum frequency characteristics of 2-phase, 8-pole, HB type, prototype linear pulse motor(LPM) were investigated with the open loop control system(OLCS) being attached to the LPH. In this experiment, both 1-phase and 1-2 phase excitation types were adopted and microcomputer was used in deal with the data. The results point to some directions for the improvement of the open loop control system.

  • PDF

2중 영 벡터 모드를 갖는 2상 개별 펄스 위치 변조기법 (A Two-Phase Separately Randomized Pulse Position PWM Technique with Double-Zero Vector Mode)

  • 김정근;오승열;정영국;임영철
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권12호
    • /
    • pp.739-750
    • /
    • 2004
  • In case while M(modulation index) is more than 0.7, the spectrum of motor voltage and current of a conventional two-phase SRP-PWM scheme are not reduced considerably. To solve the problems of a conventional two-phase SRP-PWM, this paper proposes a two-phase SRP-PWM(DZSRP-PWM) with double zero vector mode which zero vector is selected as V(111) in case of M >0.7, and zero vector is selected as V(000) if M < 0.7. For the validity of the proposed method, the PSIM simulations and experiments were achieved. And the simulation and experiment results show that the voltage and current harmonics all over the modulation index are spread to a wide band area.

Performance Evaluation of Various Bus Clamped Space Vector Pulse Width Modulation Techniques

  • Nair, Meenu D.;Biswas, Jayanta;Vivek, G.;Barai, Mukti
    • Journal of Power Electronics
    • /
    • 제17권5호
    • /
    • pp.1244-1255
    • /
    • 2017
  • The space vector pulse width modulation (SVPWM) technique is a popular PWM method for medium voltage drive applications. Conventional SVPWM (CSVPWM) and bus clamped SVPWM (BCSVPWM) are the most common SVPWM techniques. This paper evaluates the performance of various advanced BCSVPWM strategies in terms of their harmonic distortion and switching loss based on a uniform frame work. A uniform frame work, pulse number captures the performance parameter variations of different SVPWM strategies for various number of samples with heterogeneous pulse numbers. This work compares different advanced BCSVPWM techniques based on the modulation index and location of the clamping position (zero vector changing angle ) of a phase in a line cycle. The frame work provides a fixed fundamental frequency of 50Hz. The different BCSVPWM switching strategies are implemented and compared experimentally on a 415V, 2.2kW, 50Hz, 3-phase induction motor drive which is fed from an IGBT based 2 KVA voltage source inverter (VSI) with a DC bus voltage of 400 V. A low cost PIC microcontroller (PIC18F452) is used as the controller platform.

토끼 단일 심방근 세포에서 Na-Ca 교환전류의 특성에 관한 연구 (The Properties of Na-Ca Exchange Current in Single Atrial Cells of ,The Rabbit)

  • 염욱;호원경;서경필
    • Journal of Chest Surgery
    • /
    • 제22권4호
    • /
    • pp.548-561
    • /
    • 1989
  • In single atrial cells isolated from the rabbit the properties of inward current of Na-Ca exchange were investigated using the whole cell voltage clamp technique. The current was recorded during repolarization following brief 2 ms depolarizing pulse to +40 mV from a holding potential of * 70 mV. Followings are the results obtained: 1. When stimulated every 30 seconds, the inward currents were activated and reached peak values 6-12 ms after the beginning of depolarizing pulse. The mean current amplitude was 342 pA/cell. 2. The current decayed spontaneously from the peak activation and the time course of the relaxation showed two different phases fast and slow phase. The time constants were 10-18 ms and 60-140 ms, respectively. 3. The recovery of inward current was tested by paired pulse of various intervals. The peak current recovered exponentially with time constant of 140 ms and 1 p M isoprenaline accelerated the recovery process. 4. Relaxation time course was also affected by pulse interval and time constant of the fast phase was reduced almost linearly according to the decrease of pulse interval between 30 sec and 1 sec. 5. The peak activation was increased in magnitude by long prepulse stimulation, 5 p M Bay K, 1 p M isoprenaline or internal and external application of c-AMP. 6. The relaxation time constant of the fast phase was prolonged by 5 p M Bay K or c-AMP, and shortened by isoprenaline. However the time course of the slow relaxation phase was not so much changed. From the above results, it could be concluded that increase of the calcium current by Bay K or c-AMP results in the potentiation and prolongation of intracellular calcium transient, and the facilitation of Ca uptake by SR might be a mechanism of shortening the time constant of current relaxation by short interval stimulation or isoprenaline.

  • PDF