• Title/Summary/Keyword: 2차 평가인증지표

Search Result 5, Processing Time 0.02 seconds

Childcare Teacher's Perception of the Accreditation System Based on Accreditation Experience -Focused on the Second Accreditation Index of Childcare Centers- (보육교사의 평가인증 경험에 따른 평가인증제에 대한 인식비교 -2차 평가인증지표를 중심으로-)

  • Cho, Hyun-Ok;Choi, Inhwa
    • Korean Journal of Childcare and Education
    • /
    • v.7 no.4
    • /
    • pp.301-324
    • /
    • 2011
  • The purpose of this study was to examine the perception of the childcare teachers regarding accreditation procedures and feasibility of the second accreditation index according their past participation in the accreditation process. The objects were 193 childcare teachers working at child care centers that were accredited using the initial accreditation index. The collected data was analyzed using frequency, percentile, $X^2$, and t-test. The major findings are as follows: First, childcare teachers without accreditation experience perceived 'continuing education of child care center directors and teachers' to be the most important for quality maintenance after successful accreditation. In contrast, childcare teachers with accreditation experience placed the most importance on 'childcare teachers' motivation and continuing enrollment'. Second, childcare teachers with accreditation experience perceived higher feasibility in the subcategories of 'art activity materials' in the category of child care environment, 'providing operation policies and information of child care teachers', 'care for children', and 'employment contract' in the operation & management category, 'sanitary management of food, cooking and feeding', 'care of sick or injured child', 'health management of children and childcare teachers', 'snacks for children' in the category of health and nutrition and 'safe procedures for handing over children' in the category of safety. In general, childcare teachers with accreditation experience perceived higher feasibility of the second accreditation index in all categories.

Performance Evaluation Method of Tunnel Scanner for Lining Crack Detection (터널 균열 검출에 활용되는 터널스캐너의 성능검증 방법론)

  • Bae, Sung-Jae;Jung, Wook;Chamrith, Sereivatana;Kim, Chan-Jin;Kim, Young-Min;Hong, Sung-Ho;Kim, Jung-Gon;Kim, Jung-Yeol
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.1
    • /
    • pp.39-52
    • /
    • 2021
  • Purpose: Recently, due to increasing usage of high-tech equipment for facility inspection, the need of verifying high-tech equipment is being emphasized. Therefore, the purpose of this paper is to develop performance evaluation methodology of tunnel scanners that inspect tunnel facilities. Method: This paper describes literature reviews regarding the performance evaluation methodology of high-tech based equipment for facility inspection. Based on these investigations and expert advisory meetings, this paper suggests a performance evaluation methodology of tunnel scanner. Result: First evaluation indicator states minimum performance standards of tunnel scanners. Second evaluation indicator is related to tunnel scanner quality. Conclusion: The performance evaluation methodology can provide reliable equipment performance catalogues, helping users to make a proper selection of equipment. Also, developers of equipment can get authorized verification of performances, preventing poor maintenance of facilities.

Developing an Evaluation System for Certifying the Robot-Friendliness of Buildings through Focus Group Interviews and the Analytic Hierarchy Process (로봇 친화형 건축물 인증 지표 개발 : 초점집단면접(FGI)과 분석적 계층화 과정(AHP)의 활용)

  • Lee, Kwanyong;Gu, Hanmin;Lee, Yoonseo;Jung, Minseung;Yoon, Dongkeun;Kim, Kabsung
    • Journal of Cadastre & Land InformatiX
    • /
    • v.52 no.2
    • /
    • pp.17-34
    • /
    • 2022
  • With rapid advancements taking place in the Fourth Industrial Revolution, human-robot interactions have been garnering increasing attention. Robots are being actively adopted in building systems and facilities. In this study, we developed robot-friendly building certification indicators. Because these indicators were being developed for the first time, we focused only on commercial buildings. We conducted exploratory research using methodologies such as focus group interviews and the analytic hierarchy process. First, the concept of the robot-friendly building was defined through focus group interviews, and the requirements were categorized by the appropriateness of operating facilities and systems and the appropriateness of architectural and robot operating systems and networks. Next, the relative importance of the evaluation items (23 items in total) was calculated using the analytic hierarchy process. Their average score of the marks was 4.4, and the minimum and maximum were 2.0 and 11.3, respectively. This study is significant because we collected the basic data necessary to develop a one-of-its-kind evaluation system for certifying the robot-friendliness of buildings using scientific methods.

The Evaluation of Proficiency Test between Radioimmunoassay and Chemiluminescence Immunoassay (방사면역측정법과 화학발광면역측정법간의 숙련도 비교평가)

  • Noh, Gyeong-Woon;Kim, Tae-Hoon;Kim, Ji-Young;Kim, Hyun-Joo;Lee, Ho-Young;Choi, Joon-Young;Lee, Byoeng-Il;Choe, Jae-Gol;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.116-124
    • /
    • 2011
  • Purpose: To establish accurate external quality assurance (EQA) test, cross institutional and modality tests were performed using WHO certificated reference material (CRM) and same pooled patients serum. Materials and Methods: Accuracy and precision were evaluated using CRM and pooled patients' serum for AFP, CEA, PSA, CA 125, CA 19-9, T3, T4, Tg, TSH. To evaluate the accuracy and precision, recover test and coefficient variation were measured. RIA test were performed in major 5 RIA laboratory and EIA (CLIA) test were done in 5 major EIA laboratory. same sample of CRM and pooled serum were delivered to each laboratory. Results: In 2009, mean precision of total tumor marker of RIA was $14.8{\pm}4.2%$ and that of EIA(CLIA) was $19.2{\pm}6.9%$. In 2010, mean precision of 5 tumor marker and T3, T4, Tg, TSH was $13.8{\pm}6.1%$ in RIA and $15.5{\pm}7.7%$ in EIA (CLIA). There was no significant difference between RIA and EIA. In RIA, the coefficient variations (CV) of AFP, CEA, PSA, CA 125, T3, T4, TSH were within 20%. The CV of CA 19-9 was over 20% but there was no significant difference with EIA (CLIA) (p=0.345). In recovery test using CRM, AFP, PSA, T4, TSH showed 92~103% of recovery in RIA. In recovery test using commercial material, CEA, CA 125, CA 19-9 showed relatively lower recovery than CRM but there was no significant difference between RIA and EIA (CLIA). Conclusion: By evaluating the precision and accuracy of each test, EQA test could more accurately measured the quality of each test and performance of laboratory.

  • PDF

Distribution Characteristics of Platinum Group Elements in Roadside Dust from Daejeon, Korea (대전 도로변 먼지내 Platinum Group Elements의 분포 특성)

  • Lim, Jong-Myoung;Jeong, Jin-Hee;Lee, Jin-Hong
    • Journal of Environmental Impact Assessment
    • /
    • v.27 no.5
    • /
    • pp.405-416
    • /
    • 2018
  • In this research, the distribution of Platinum Group Elements (PGEs) at roadside dust in Daejeon, Korea was examined using an ICP-MS (Inductively Coupled Plasma-Mass Spectrometry) technique. For the quality assurance of the determination, method validation based on its accuracy and precision was conducted using SRM (Standard Reference Material). It was found that the relative errors of Pt, Pd, and Rh against each SRM value were -0.7%, -10.0%, and -20.4%, respectively, while relative standard deviations for three elements were less than 10%. The concentrations of Pt, Pd and Rh in roadside dust averaged as $17.4{\pm}9.2{\mu}g/kg$, $283.6{\pm}20.5{\mu}g/kg$, and $7.3{\pm}2.8{\mu}g/kg$, respectively. The concentrations of Pt and Rh have significantly higher distribution patterns in the dust at roadside and underground parking lot than those in soil of the background or other urban area. The correlation analysis between concentrations of PGEs in roadside dust indicates that the distribution of Pt and Rh concentration were strongly affected by automobile sources.