• Title/Summary/Keyword: 2차 방사선

Search Result 892, Processing Time 0.031 seconds

Study of the Difference in Residual Amounts according to the Method of Securing Intravenous Injections and the Dose of Physiological Saline during 18F-FDG Administration (18F-FDG 투여 시 정맥주사 확보 방법 및 생리식염수 용량에 따른 잔류량의 차이에 관한 연구)

  • Ryu, Chan-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.2
    • /
    • pp.95-102
    • /
    • 2022
  • This study compares the difference between the remaining amount in syringes according to injection method and the dose of physiological saline when the radiopharmaceutical 18F-FDG isotope is injected into patients who visited the hospital for PET examination. After performing a CT or MRI using a contrast medium when 18F-FDG was injected into 40 patients who came to the hospital for PET examination without removing the 3-way, the radioactivity remaining in the syringe and the 3-way was measured and the dose of radioactivity confirmed. At this time, 20 patients were divided into different dose groups of physiological saline. Another injection method was used to compare the remaining amount of the syringe and the difference in the remaining amount according to the amount of physiological saline when the injection was performed with an extension. After an injection of 18F-FDG, the actual administered dose was confirmed by measuring the radioactivity remaining in the syringe and the 3-way or extension with a calibrator. As a result of measuring the radioactivity of the syringe before administering the radiopharmaceutical and the radioactivity of the syringe and the 3-way or extension after administration, the 3-way injection method in 10 cc's of physiological saline had the lowest residual amount. The remaining amount increased in the order of the extension to 10 cc's of saline and the 3-way to 5 cc's of saline. Likewise, the 5 cc's saline solution and the extension injection method demonstrated the highest residual amounts. The residual difference with the lowest level of remaining injection method was found to be 0.053 mCi. It was found that in a PET examination, by considering the radioactivity remaining in the 3-way and extension and by adjusting the dose of physiological saline, if the intended dose to be administered to the actual patient is determined, it is possible to administer the radiopharmaceutical to the patient more accurately.

Normal Corpus Callosum Dimensions Measured by MRI (MR Midsagittal 영상을 이용한 정상 뇌량의 크기 측정)

  • Kim, Ham-Gyum
    • Journal of radiological science and technology
    • /
    • v.31 no.3
    • /
    • pp.277-285
    • /
    • 2008
  • As a result of measuring the size of corpus callosum in normal Korean people by using MRI, the following conclusions were obtained. 1. Maximum, minimum, and mean values by the region in whole subjects 1) Anteroposterior length amounted to the mean with 69.30mm, the minimum with 50.70mm, and the maximum with 80.40mm. 2) Diameter of genu amounted to the mean with 11.93mm, the minimum with 6.00mm, and the maximum with 18.50mm. 3) Diameter of mid body amounted to the mean with 7.00mm, the minimum with 3.40mm, and the maximum with 10.40mm. 4) Diameter of narrowing portion amounted to the mean with 4.51mm, the minimum with 0.80mm, and the maximum with 9.50mm. 5) Diameter of splenium amounted to the mean with 12.17mm, the minimum with 6.90mm, and the maximum with 17.20mm. 2. Comparison by region according to the gender in the whole subjects 1) Anteroposterior length was bigger in men than in women, and showed the significant difference depending on gender. 2) Diameter of genu, diameter of mid body, and diameter of narrowing portion were bigger in men than in women, but there was no significant difference. 3) Diameter of splenium was bigger in men than in women, and showed the statistically significant difference. 3. Comparison by region according to the age in the whole subjects 1) Anteroposterior length was the biggest in the 50s at the age, and was smaller in heir 10s than other age levels. In addition, the significant difference was indicated depending on age. 2) Diameter of genu and diameter of mid body were the biggest in their 30s, and were smaller in the 60s than other age levels. And, the statistically significant difference was indicated. 3) Diameter of narrowing portion was the thickest in their 20s, and was thinner in their 60s than other age levels. And, the significant difference was indicated depending on age. 4) Diameter of splenium was the thickest in their 30s, and was thinner in their 10s than other age levels. And, the statistically significant difference was indicated. 4. Correlation by region in whole subjects 1) Diameter of genu showed the statistically significant positive correlation with anteroposterior length. 2) Diameter of mid body showed the statistically significant positive correlation with anteroposterior length and diameter of genu. 3) Diameter of narrowing portion didn't show the statistically significant correlation with anteroposterior length, but showed the statistically significant positive correlation with diameter of genu and diameter of mid body. 4) Diameter of splenium showed the statistically significant positive correlation with anteroposterior length, diameter of genu, diameter of mid body, and diameter of narrowing portion.

  • PDF

The Effects of Rat's Sperm Bioassay for Low Dose X-Ray (저선량 X-선 조사가 쥐의 정자에 미치는 생물학적효과)

  • Jin, Gye-Hwan;Min, Soo-Young;Lee, Sang-Bock;Lee, Sam-Yul;Park, Jong-Bae;Lee, Jun-Haeng
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.4
    • /
    • pp.184-189
    • /
    • 2007
  • In order to investigate the enhancement effects of low dose radiation on biological activation, this study applied low dose X-ray to the whole body of male rats to find out whether hormesis is induced in male germ cells. Total 36 Sprague-Dawley(SD) rats as experimental animal were subdivided into 6 groups(in 6 rats per group) such as control, 10 mGy, 20 mGy, 50 mGy, 100 mGy and 200 mGy radiation group All the groups showed slightly increasing number of sperms per 0.1g semen ($14.216{\times}10^6,\;13.901{\times}10^6,\;14.153{\times}10^6,\;13.831{\times}10^6,\;14.137{\times}10^6,\;14.677{\times}10^6$ respectively), and the motility of sperms amounted to 50.9%, 49.5%, 55.1%, 54.3%, 48.0% and 52.2% respectively. Particularly, compared to the control, the other 5 groups showed higher male hormone level, and the microscopic observations of testicle tissues showed no vacuolization in seminiferous tubules and testis cells. In the results of this experiment, no harmful effect was observed on Sprague-Dawley (SD) rats for which the dose of radiation was controlled as regulated legally by the Ministry of Science and Technology and the Ministry of Health and Welfare. However, as these results were obtained from a limited number of animals, we cannot maintain that the same effect will be observed in the human body. Therefore, there should be further research on the effect on other animals and ultimately on the human body.

A COMPARATIVE ANALYSIS OF CLASS II DIVISION 1 TREATMENTS : ADOLESCENTS CONTRASTED WITH ADULTS (성장기 아동과 성인에서의 II급 1류 부정교합치료양상에 관한 두부방사선 계측학적 비교연구)

  • Kang, Bo-Seon;Yang, Won-Sik
    • The korean journal of orthodontics
    • /
    • v.25 no.3 s.50
    • /
    • pp.247-261
    • /
    • 1995
  • The purpose of this study was to quantitate differences in the nature of the correction of Angle's Class II div 1 malocclusion dependent on the patient's age at the time of treatment. The sample consisted of 27 female patients in the adolescent group with a mean initial records age of 11.8 years and 25 female patients in the adult group with a mean starting age of 21.1 yrs. Lateral cephalometric head films were taken before and after orthodontic treatment with four bicuspid extraction. The results were obtained as follows. 1. None of maxillary skeletal parameters exhibited a significantly different in treatment change between adolescents and adults. But, in mandibular skeletal measurements, there were significant differences between two groups. (P<0.05) 2. Measures of vertical dimension in the adults remained unchanged during treatment, reflecting the effective absence of growth. 3. The steepness of occlusal plane in the adults changed significantly.(P<0.05) In contrast, the adolescents displayed stability of the occlusal plane. 4. According to the Johnston analysis, there was a significant difference in the total molar correction between two groups.(P<0.05) 5. According to the Johnston analysis, differential mandibular growth in the adolescents contrubuted $63\%$ of the total molar correction, with orthodontic tooth movement accounting for the remaining $37\%$. In the adults, dental movement comprised $99\%$ of the correction.

  • PDF

Retrospective study on marginal bone resorption around immediately loaded implants (즉시 하중 임플란트에서 변연골 흡수량에 관한 후향적 연구)

  • Lee, Sung-Hoon;Jung, Ji-Hye;Lee, Jin-Han;Cho, Hye-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.2
    • /
    • pp.114-119
    • /
    • 2018
  • Purpose: Patients who treated implant immediate loading within a week after implant placement at Wonkwang University Dental Hospital Implant Center were evaluated marginal bone resorption. These retrospective analyses are intended to reinforce the clinical evidence for the implant immediate loading. Materials and methods: Medical history and radiographic data were investigated, which were the patients' who treated implant immediate loading and restoration with provisional prostheses between January 2005 and June 2016, at Wonkwang University Dental Hospital Implant Center. Total number of implants was 70, marginal bone resorption was measured according to implant length, diameter and connection type. To measure marginal bone resorption, periapical radiographs were taken when the implants were placed and after 6 month. Statistical analysis was done in Mann-whitney U test and Kruskal-wallis test with SPSS 22.0 software (P<.05). Results: Mean marginal bone resorption around immediately loaded implants according to implant connection type was shown $1.24{\pm}0.72mm$ in internal hexagon connection type and $1.73{\pm}1.27mm$ in external hexagon connection type. There was no statically significant difference in marginal bone resorption with implant length and diameter. Conclusion: Implants with immediated loading in internal hexagon connection type showed less marginal bone resorption significantly than in external hexagon connection type.

Measurement of ROI Temperature in Herniation of Intervertebral Disc Patients Using DITI (디지털 적외선 체열진단기를 이용한 추간판탈출증 환자의 ROI 온도측정)

  • Park, Jeong Kyu;Park, Jong Sam;Kwon, Soon Mu
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.4
    • /
    • pp.273-278
    • /
    • 2017
  • Among 45 patients of herniation of intervertebral disc with $L_4$ to $L_5$ herniation, who underwent infrared thermography, the number of female was larger than male and the age of 50s was highest. From the results measured from the distribution table, we have confirmed that there was no significant difference depending on sex and age (p> 0.05). The region of the highest ROI temperature for patients with $L_4-L_5$ intervertebral disc prolapse was the back of the posterior right tibia, and followed by the back of the left shin bone-below the front right knee-below the front left knee. There was a significant difference depending on the measured site. The average ROI temperature for patients was $30.30{\pm}0.50$ whereas that for normal persons was $31.20{\pm}0.58$, yielding the temperature difference of $0.66{\pm}0.59$ between the two groups. The ROI of patients was lower than $31.20{\pm}0.58$ (p <0.05) because the significance of the sample, which has been obtained from the results of a sample t-test, was less than 0.05 (p <0.05). From further researches, it may necessary to develope the methodology for correcting data regarding thermal environment and, in addition, to develope a new thermal index based on it. Therefore, we can confirm that pre-treatment for infrared thermography is very important in order to minimize the procedure for correcting data. It is required that radiologists who inspect disc herniations should carefully observe and consider the patients during their measurements.

Batch Scale Storage of Sprouting Foods by Irradiation Combined with Natural Low Temperature -V. Cooking Qualities of Irradiated Chestnut after Long-term Storage- (방사선조사(放射線照射)와 자연저온(自然低溫)에 의한 발아식품(發芽食品)의 Batch Scale저장(貯藏)에 관(關)한 연구(硏究) -제5보(第五報) : 장기저장(長期貯藏)된 조사(照射)밤의 조리적성(調理適性)에 대하여-)

  • Yang, Ho-Sook;Kim, Jong-Gun;Cho, Han-Ok;Byun, Myung-Woo;Kwon, Joong-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.15 no.3
    • /
    • pp.238-244
    • /
    • 1983
  • The cooking quality of irradiated chestnut after longterm storage were evaluated. 1. Color degree and tannin content of irradiated chestnut were slightly increased with the storage, but there was a little difference according to the radiation dose after nine months storage. 2. The main component of free sugars in the irradiated chestnut were identified as sucrose, glucose, fructose and the amino acids of chestnut were identified in the decreasing order of glutamic acid, aspartic acid, leucine, arginine, glycine, alanine, serine, pheylalanine, threonine, valine, isoleucine, tyrosine, methionine and cystein. Free sugars and amino acids of 25 Krad irradiated group showed a little difference compared with those of control group after nine months storage. 3. The calorie of candied chestnut prepared from nine months stored was marked 199 Kcal/100g of edible parts compared with 159 Kcal of raw chestnut. 4. Texture and sensory evaluation of candied chestnut prepared from nine months stored were better in 20-25 Krad irradiated group than in control group.

  • PDF

Non-surgical Treatment for Secondary Spontaneous Pneumothorax Associated with Bacterial Pneumonia in a Beagle Dog (비글견에서 세균성 폐렴으로 인한 속발성 자발 기흉의 비외과적 치료)

  • Han, Hyun-Jung;Yoon, Hun-Young;Kim, Jun-Young;Jang, Ha-Young;Choi, Seok-Hwa;Jeong, Soon-Wuk
    • Journal of Veterinary Clinics
    • /
    • v.25 no.1
    • /
    • pp.31-36
    • /
    • 2008
  • One year old, male beagle dog was presented with acute onset of severe dyspnea, cyanosis, and anorexia. He had no trauma history. Five days earlier, the dog had been diagnosed as bacterial pneumonia caused by Pseudomonas aeruginora and E. coli. He exhibited a restrictive respiratory pattern and at admission, immediately oxygen supplementation given. On a ventrodorsal(VD) radiographic view, right lung was collapsed and contrasted with the air-filled pleural space. The mediastinum, heart, and great vessels were shifted to the left. On a right-lateral radioraphic view, the heart appeared to be elevated from the sternum. The dog was diagnosed as secondary spontaneous pneumothorax resulting from bacterial pneumonia. The chest tubes were placed on the right and left pleural cavity under general anesthesia. At 3 days after treatment, on a VD radiograph, air of right pleural cavity disappeared while left pleural cavity showed radiolucent area filled with air, and the heart was shift to the right. Therefore, the left tube thoracostomy was performed too. The right chest tube was maintained for 5 days and the left chest tube was maintained for 45 days. During the period, antibiotics and vitamin I were used for managing of bacterial pneumothorax and preventing of retroinfection through the tubes. As the result, bacterial pneumonia was well managed by medicines and secondary SP was completely treated that air in bilateral pleural cavity disappeared on radiographs. During the follow-up for 2 years, patient showed normal condition without recurrence.

Analysis of change of internal organ in the Inter-and Intrafraction using MVCT (MVCT를 이용한 치료 간(Interfraction) 그리고 치료 중(Intrafraction) 내부 장기 변화 분석)

  • Jung, Won Seok;Kim, Ju Ho;Kim, Young Jae;Shin, Ryung Mi;Oh, Jeong Hun;Jeong, Geon A;Jo, Jun Young;Kim, Gi Chul;Choi, Tae Kyu
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.115-126
    • /
    • 2014
  • Purpose : Depending on a variety of therapeutic areas using MVCT(Megavoltage computed tomography) intra-and interfraction is to evaluate changes in patient position. Materials and Methods : In this study, head and neck, thorax, liver, and prostate tumor patients, 48 people with a full course of treatment for patients with various MVCT scan was performed. Average 60 per patient MVCT images were acquired and analyzed. Results : Interfraction error thorax and abdomen, and pelvis in the longitudinal difference was more than 3 mm. Intrafraction to see a change after the end of treatment MVCT taken, and the results confirmed Intrafraction 2 mm in motion around the longitudinal difference. In addition, due to changes in the movement before and after treatment, Inter-and Intrafraction difference was found. Conclusion : In the present study, the Head and Neck, Thorax, liver, prostate cancer in patients with inter-and intrafraction changes and target the appropriate fixtures to complete the outline of the margin would be helpful is considered.

A Study on the Resolution Analysis of Digital X-ray Images with increasing Thickness of PMMA (조직 등가물질 두께 증가에 따른 디지털 엑스선 영상의 해상도 분석에 관한 연구)

  • Kim, Junwoo
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.173-179
    • /
    • 2021
  • Scattered x-ray generated by digital radiography systems also have the advantage of increasing signals, but ultimately detectability is reduced by decreasing resolution and increasing noise of x-ray images transmitted objects. An indirect method of measuring scattered x-ray in a modulation-transfer function (MTF) for evaluating resolution in a spatial-frequency domain can be considered as a drop in the MTF value corresponding to zero-frequency. In this study, polymethyl methacrylate (PMMA) was used as a patient tissue equivalent, and MTFs were obtained for various thicknesses to quantify the effect of scattered x-ray on resolution. X-ray image signals were observed to decrease by 35 ~ 83% with PMMA thickness increasing, which is determined by the absorption or scattering of x-rays in PMMA, resulting in reduced MTF and increased scatter fraction. The method to compensate for MTF degradation by PMMA resulted in the MTF inflation without considering the optical spreading generated by the indirect-conversion type detector. Data fitting or zero-padding are needed to compensate for MTF more reasonably on edge-spread function or line-spread function.