• Title/Summary/Keyword: 2차의 정확도

Search Result 1,618, Processing Time 0.031 seconds

An Improved Validation Technique for the Temporal Discrepancy when Estimated Solar Surface Insolation Compare with Ground-based Pyranometer: MTSAT-1R Data use (표면도달일사량 검증 시 발생하는 시간 불일치 조정을 통한 정확한 일사량 검증: MTSAT-1R 자료 이용)

  • Yeom, Jong-Min;Han, Kyung-Soo;Lee, Chang-Suk;Kim, Do-Yong
    • Korean Journal of Remote Sensing
    • /
    • v.24 no.6
    • /
    • pp.605-612
    • /
    • 2008
  • In this study, we estimate solar surface insolation (SSI) by using physical methods with MTSAT-1R data. SSI is regarded as crucial parameter when interpreting solar-earth energy system, climate change, and agricultural production predict application. Most of SSI estimation model mainly uses ground based-measurement such as pyranometer to tune the constructed model and to validate retrieved SSI data from optical channels. When compared estimated SSI with pyranometer measurements, there are some systemic differences between those instruments. The pyranometer data observed upward-looking hemispherical solid angle and distributed hourly measurements data which are averaged every 2 minute instantaneous observation. Whereas MTSAT-1R channels data are taken instantaneously images at fixed measurement time over scan area, and are pixel-based observation with a much smaller solid angle view. Those temporal discrepancies result from systemic differences can induce validation error. In this study, we adjust hour when estimate SSI to improve the retrieved accurate SSI.

Problems of Benefit Sharing Support Policy and its Policy Effectiveness affecting the Firm Performance (성과공유제 지원정책의 문제점 분석 및 기업성과에 미친 효과성 연구)

  • Lee, Hongyeol;Lee, Eun-Ku
    • Journal of Convergence for Information Technology
    • /
    • v.8 no.4
    • /
    • pp.237-245
    • /
    • 2018
  • The purpose of this study is to suggest the improvement plan for an effective benefit sharing support policy through empirical analysis on the benefit sharing operation of government as well as the benefit sharing support policy of government affecting firm performance. Therefore, this study analyzed current problems on benefit sharing operation of government as well as performed a survey for 225 participating and cooperation firms regarding firm performance. This study found some improvements such as insufficient diverse incentive measures leading to the difficulty of participating firm's increase and spread, insufficient substantial benefit sharing such a cash allocation between consignment firms, the increase of biz management system model failing to induce innovation of new technology or product, and difficult spread into 2nd, 3rd cooperative firms besides 1st ones, meanwhile, verifying the positive influence of government benefit sharing support policy on both participating and cooperation firms, especially on the performance of cooperation firms. As a further study, it is necessary to increase the objectiveness and accuracy of a research through verification of the interrelationships between firm statue and performance on the basis of more objective and quantitative data such a sales increase or R&D capability of cooperation firms.

Comparison of KSL Curriculum and ESL Curriculum for Adaptation of International Students in the Internet of Things era to Domestic Universities (사물인터넷시대의 유학생의 국내대학 적응을 위한 KSL 교과과정과 ESL 교과과정 비교)

  • Kang, Hyun-Joo;Jeong, Se Ri;Choi, Jang Won
    • Journal of Internet of Things and Convergence
    • /
    • v.7 no.2
    • /
    • pp.21-29
    • /
    • 2021
  • In this study, it is necessary to supplement the Korean language curriculum in order for international students to adapt and settle in Korea in an era where education is being transformed into future education due to the 4th industry. In the KFL (Korean as a Foreign Language) situation encountered by international students, they suffer from difficulties in university mathematics due to communication problems due to lack of language ability, which is one of the stress factors for cultural adaptation in the Korean language education program. To solve this problem, we analyzed ESL programs in English-speaking countries and KSL programs in Korea to set educational goals, curriculum, and educational methods to achieve goals for international students, and to establish curriculum and learning processes. Therefore, the Korean language education program (KSL program) for foreign students in the Korean language curriculum should also be supplemented by accepting the advantages of setting accurate goals for the ESL program and linking it with university graduation in the curriculum of English-speaking countries. In addition, for international students to learn Korean, an integrated Korean language education course and management system using IT suitable for the 4th industrial age is needed.

Crack Propagation Analysis for IMO Type-B Independent Tank with Liquefied Natural Gas Carrier (LNG 운반선에 적용된 독립형 탱크의 균열 진전 해석에 관한 연구)

  • Kim, Beom-il;Shafiqul, Islam MD
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.4
    • /
    • pp.529-537
    • /
    • 2021
  • Membrane-type hull and cargo holds have been designed and built for large ship. However, there is a growing interest in applying the same technology to small and medium-sized Liquefied natural gas(LNG) carriers to meet the recent increase in demand for LNG as an ecofriendly fuel and for expanding LNG bunkering infrastructure. The purpose of this study is to apply the IMO Type-B tank to small and medium-sized LNG carriers and verify the safety and suitability of the design. Fatigue crack propagation analysis was performed to install a partial second drip tray installed at the lower part of the LNG cargo tank by calculating the amount of leaked gas in the support structure supporting the cargo tank. First, a program for fatigue crack propagation analysis was developed, in which Paris' law and British Standard 7910 (BS 79110) were applied based on the International Code for the Construction of Equipment and Ships Carrying Liquefied Gases in Bulk, an international standard for LNG carriers. In addition, a surface crack propagation analysis was performed. Next, a methodology for assuming the initial through-crack size was developed to determine the size of the partial second barrier. The analysis was performed for 15 days, which is a possible return time after cracks are detected. Finally, the safety and suitability of the IMO Type-B for LNG cargo tanks required by international regulations were verified. For the accurate analysis of fatigue crack propagation, it is necessary to develop and verify the analysis procedure based on direct analysis and international regulations.

Survey of Point-of-Care Testing Devices for Pre-hospital EMS Equipment of Glucometer on Local Area (지역 EMS의 현장검사 혈당측정기 사용에 대한 실태조사)

  • Byeong-Hyun, Kim;Dai-Hai, Choi;Gyoung-Yim, Ha
    • Journal of agricultural medicine and community health
    • /
    • v.47 no.4
    • /
    • pp.220-228
    • /
    • 2022
  • Objective: glucometer is one of POCT(point-of-care testing) devices used by EMS. Accurate measurement value is important for patient decision making. Quality control is necessary for this, but most EMS are still using glucometer without quality control it. Therefore, management status and quality control status of glucometers used by 119 paramedics waswere investigated. Methods: 6 and 8 of glucometers and blood glucose test strips were submitted from 4 safety centers in 2010 and 8 safety centers in 2012, respectively. Glucometers submitted by local safety centers were analyzed in 2010 and 2012. The control glucometer, which was well managed at A University Hospital, was assumed to be accurate for at blood glucose measurement. Glucose values of various quality control materials control solutions were measured and analyzed using linear regression and Pearson's correlation test. Error rates were obtained via error tolerance range required by the 2011 ISO(International Organization for Standardization) guideline. For statistics, Excel and MedCalC programs were used. Results: mong 14 safety centers in the region, 4 centers(28.5%) in 2010 and 8 centers(57.1%) in 2012 submitted 6 and 8 glucometers. In the first evaluation in 2010, 2 out of 6(33.3%) glucometers were untestable due to error, and 45 out of 6(66.683.3%) blood glucose test strips' validity were expired. In the second evaluation in 2012, 1 out of 8(13.5%) glucometers were untestable due to lack of battery, and 2 out of 8(25%) blood glucose test strips' validity were expired. All correlation coefficients were above 0.989 in 2010 and above 0.997 in 2012. Error rates were generally high when using expired blood glucose test strips. Conclusion: Among 119 paramedics' guideline, quantity and operation status of POCT devices are well managed, but quality control is not. Therefore, it is necessary to add management status and quality control status of POCT devices to the EMS' field work guideline.

Lung Adenocarcinoma Gene Mutation in Koreans: Detection Using Next Generation Sequence Analysis Technique and Analysis of Concordance with Existing Genetic Test Methods (한국인의 폐선암 유전자 돌연변이: 차세대 염기서열 분석법을 이용한 검출 및 기존 유전자 검사법과의 일치도 분석)

  • Jae Ha BAEK;Kyu Bong CHO
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.55 no.1
    • /
    • pp.16-28
    • /
    • 2023
  • Lung adenocarcinoma accounts for about 40% of all lung cancers. With the recent development of gene profiling technology, studies on mutations in oncogenes and tumor suppressor genes, which are important for the development and growth of tumors, have been actively conducted. Companion diagnosis using next-generation sequencing helps improve survival with targeted therapy. In this study, formalin-fixed paraffin-embedded tissues of non-small cell lung cancer patients were subjected to hematoxylin and eosin staining for detecting genetic mutations that induce lung adenocarcinoma in Koreans. Immunohistochemical staining was also performed to accurately classify lung adenocarcinoma tissues. Based on the results, next-generation sequencing was applied to analyze the types and patterns of genetic mutations, and the association with smoking was established as the most representative cause of lung cancer. Results of next-generation sequencing analysis confirmed the single nucleotide variations, copy number variations, and gene rearrangements. In order to validate the reliability of next-generation sequencing, we additionally performed the existing genetic testing methods (polymerase chain reaction-epidermal growth factor receptor, immunohistochemistry-anaplastic lymphoma kinase (D5F3), and fluorescence in situ hybridiation-receptor tyrosine kinase 1 tests) to confirm the concordance rates with the next-generation sequencing test results. This study demonstrates that next-generation sequencing of lung adenocarcinoma patients simultaneously identifies mutation.

The Study on relationship between CSV and Investment Efficiency (CSV와 투자효율성에 관한 연구)

  • Ho-Yeong Kim
    • Journal of Digital Convergence
    • /
    • v.21 no.2
    • /
    • pp.33-40
    • /
    • 2023
  • In this study, we aim to examine the impact of corporate social responsibility implementation, which is a major concern in previous research, on investment efficiency. The research method will be a qualitative study with reference to existing previous research. The three main claims to be addressed in this study will be summarized, and the research variables and research models will be described. As a result of the study, based on existing previous research, this study presented three issues to examine how a high level of corporate social responsibility performance increases investment efficiency. First, we argue that a company's high level of social responsibility will be positively related to investment efficiency. Second, it is argued that investment efficiency will be positively related to individual CSR components that represent the interests of primary stakeholders. Third, it is argued that companies with too high a CSR index and companies with a too low CSR index will have less correlation with investment efficiency. The contribution of this study will be to more accurately understand the impact of CSR on corporate investment efficiency. In the future, it is hoped that additional discoveries will be made through research that adopts the three claims presented in this study as hypotheses and empirically analyzes them. The Journal of Digital Policy & Management. This space is for the abstract of your study in English.

Status and plan of 'Operation rule improvement and ecological restoration plan of Nakdong estuary' ('낙동강하굿둑 운영개선 및 생태복원 방안 연구 용역' 추진현황 및 계획)

  • Noh, Hee Kyung;Ryu, Hyung Kwan;Ryu, Jong Hyun;Kim, Hwa Young;Chun, Ja Hoon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.21-22
    • /
    • 2020
  • 낙동강 하굿둑(이하 하굿둑)은 1987년 부산 사하구와 강서구 사이에 건설되어 하류 지역의 바닷물 유입을 막아 부산, 울산, 경남 등에 안정적으로 생활·농업·공업 등의 분야에 용수를 공급하는 역할을 해왔다. 현재, 하굿둑의 수문은 낙동강 상류로부터 하류로 흘러내려오는 민물(담수)을 방류하기 위해서만 하굿둑 수문을 개방하고 있다. 하구는 하천의 담수와 바다의 염수가 서로 만나는 구역으로 바닷물과 염수의 밀도차에 의한 혼합으로 자연상태의 하구에서는 담수와 염수가 섞이는 기수역이 형성되며, 이러한 특성으로 하구 인근의 지역에서는 일반적인 하천 및 해양, 연안과는 분명히 구별되는 생태계가 조성된다. 하굿둑 건설이후 바닷물(해수)과 민물(담수)이 만나는 낙동강 어귀에 기수생태계가 사라지면서 바닷물이 유입될 수 있도록 하여 생태계를 복원해야 한다는 필요성이 제기되어 왔으며, 하굿둑이 지역에 기여해온 사실은 분명하나 하굿둑으로 인해 생태계 단절이 발생하고 기수생태계가 파괴되었기 때문에 이를 해결하기 위해서는 하굿둑을 개방하여 과거 기수생태계를 복원해야 한다는 목소리가 높아지고 있다. 이에 따라 정부에서는 하굿둑의 기수생태계 복원을 위해서 관계기관 합동으로 의사결정을 하고 효율적인 개방 방안을 모색하는 실무협의회를 구성하여 운영 중이고, 실무협의회 논의를 통해 5개 주요 관계기관(환경부, 국토부, 해양수산부, 부산광역시, K-water) 공동으로 "낙동강하굿둑 운영개선 및 생태복원 방안 연구용역"을 추진 중이다. 2018년 1단계 용역이 완료되었으며, 2019년부터 2단계 연구용역을 추진 중이고 하굿둑 개방의 수준별로 각종 영향을 검토한 후 대책을 마련하여 기수생태계 복원 방안을 수립하는데 그 목적이 있다. 2단계 연구용역에서는 과학적이고 합리적인 기수생태계 복원방안 마련을 위해서 실제로 해수를 유입시키는 3차례의 실증실험 및 수리모형실험 등을 추진한다. 기존 연구들에서도 수문개방에 따른 해수유입 영향에 대해 모델링을 통해서 분석했지만 이는 검증이 이루어지지 않은 결과로 이번 용역에서는 실제 해수를 유입시키고 염분의 침투 및 각종 수생태 영향을 모니터링 한 후 그 결과를 반영하여 모델링을 고도화하고 있다. 최종적으로 고도화된 모델링 결과를 기반으로 기수생태계 조성 방안별로 염분, 수질, 수생태, 침퇴적 등 각종 분야에 대한 정확한 영향을 분석하고 이에 대한 대책을 포함하여 최종적으로 바람직한 기수생태계 복원 방안을 제시할 계획이다. 기수생태계 복원 방안이 계획에만 그치지 않고 실행으로 연결시키기 위해서 필요성에 대한 이해를 바탕으로 공감대를 형성해 나아가고 있으며 지역주민, 전문가, 관계기관 등 민(民)·관(官)·학(學) 다양한 의견을 수렴하여 하구지역내 수량-수질-수생태를 종합적으로 고려하여 복원 방안을 마련 후 사회적인 합의를 추진하여 확정할 예정이며, 하구의 안정적인 관리를 위해 AI 등 4차 산업혁명기술을 적극 적용하는 스마트한 하구물관리(Smart Estuary Watershed Management)"를 활용한 "하구통합물관리" (Estuary Integrated Watershed Management) 등 과학적인 관리를 추진할 계획이다.

  • PDF

Research on Usability of Mobile Food Delivery Application: Focusing on Korean Application and Chinese Application (모바일 배달 애플리케이션 사용성 평가 연구: 한국(배달의민족)과 중국(어러머)을 중심으로)

  • Yang Tian;Eunkyung Kweon;Sangmi Chai
    • Information Systems Review
    • /
    • v.20 no.1
    • /
    • pp.1-16
    • /
    • 2018
  • The development and generalization of the Internet increased the popularity of food delivery service applications in Korea. The food delivery market based on online-to-offline service is growing rapidly. This study compares the usability of Korean food delivery service application between that of Chinese food delivery service application. This study suggests improvement points for Korean food delivery service applications. To conduct this study, we explore the status of various food delivery service applications and conduct interviews and surveys based on the honeycomb model developed by Peter Morville. This study obtained the following results. First, all restaurants participating in the Korean food delivery service must be able to accept order through the application. Second, the shopping cart function must be able to accept order of all restaurants simultaneously. Third, when users look for menu recommendation, their purchase history and shopping cart functions should appear at the first page of the website. Users should be able to perceive the improved usability of the website using those functions. Fourth, when the search window is fixed on the top of each page, users should be able to find the information they need. Fifth, the application must allow users to find the exact location of the delivery person and the estimated delivery time. Finally, the restaurants'address should be disclosed and fast delivery time should be confirmed to enhance users'trust on the application. This study contributes to academia and industry by suggesting useful insight into food delivery service applications and improving the point of food delivery service application in Korea.

Effect of Different CT Scanner Types and Beam Collimations on Measurements of Three-Dimensional Volume and Hounsfield Units of Artificial Calculus Phantom (인공결석모형물의 부피와 하운스필드값 측정에 대한 전산화단층촬영기기의 타입과 빔 콜리메이션의 영향)

  • Wang, Jihwan;Lee, Heechun
    • Journal of Veterinary Clinics
    • /
    • v.31 no.6
    • /
    • pp.495-501
    • /
    • 2014
  • The objective of this study was to evaluate the differences and reproducibility of Hounsfield unit (HU) value and volume measurements on different computed tomography (CT) scanner types and different collimations by using a gelatin phantom. The phantom consisting of five synthetic simulated calculus spanning diameters from 3.0 mm to 12.0 mm with 100 HU was scanned using a two-channel multi-detector row CT (MDCT) scanner, a four-channel MDCT scanner, and two 64-channel MDCT scanners. For all different scanner types, the thinnest possible collimation and the second thinnest collimation was used. The HU values and volumes of the synthetic simulated calculus were independently measured three times with minimum intervals of 2 weeks and by three experienced veterinary radiologists. ANOVA and Scheff$\acute{e}$ test for the multiple comparison were performed for statistical comparison of the HU values and volumes of the synthetic simulated calculus according to different CT scanner types and different collimations. The reproducibility of the HU value and volume measurements was determined by calculating Cohen's k. The reproducibility of HU value and volume measurements was very good. HU value varied between different CT scanner types, among different beam collimations. However, there was not statistically significant difference. The percent error (PE) decreased as the collimation thickness decreased, but the decrease was statistically insignificant. In addition, no statistically significant difference in the PEs of the different CT scanner types was found. It can be concluded that the CT scanner type insignificantly affects HU value and the volumetric measurement, but that a thinner collimation tends to be more useful for accurate volumetric measurement.