• Title/Summary/Keyword: 1m distance

Search Result 2,638, Processing Time 0.03 seconds

Effect of different plant densities on growth and yield of sorghum(Sorghum bicolor L. Moench.)

  • Cho, Young Dae;Jung, Ki Yuol;Chun, Hyun Chung;Lee, Sang Hun;Kang, Hang Won
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2017.06a
    • /
    • pp.206-206
    • /
    • 2017
  • Sorghum is a crop with a various plant height depending on the planting density. If the height exceeds 1.8m, which is the harvestable height of the combine, loss is caused by clogging of the installation, entrance of the threshing section and the threshing section. The purpose of this study is to set the planting distance and number of plants per hill suitable for combine harvesting as the plant length does not exceed 1.8m. The experimental variety was Nampungchal. The experiment design was a split-plot design with three replications. The treatments were as follow: Main-plot were 1 and 2 plants as number of plants per hill and sub-plots were $60{\times}20cm$ (practice), $70{\times}15$, 20, 25, 30 cm as planting distance. The amount of nitrogen, phosphate and potassium fertilization were 100, 70, $80kg\;ha^{-1}$. Data were collected: (1) grain yield: weight of grain in $kg\;ha^{-1}$, (2) 1000 grain weight: average weight of 1000 grain, (3) plant height: distance from soil to top of panicle, (4) ear length: distance from top of stem to top of ear in cm, (5) stem diameter: diameter of second internode, (6) tiller number per hill. Analyses of variance were performed using R version 3.3.1(https://www. r- project. org). The Duncan's multiple range test(DMR) was used to separate treatment means at P < 0.05. As number of plants per hill increased, plant height and yield increased and tiller number decreased. As planting distance increased, plant height and yield decreased and tiller number increased. At 1 plant per hill, the plant height did not exceed 1.8m at all planting distance. At 2 plants per hill, the plant height did not exceed 1.8m from the planting distance of $70{\times}25cm$. At 1 plant per hill, the tiller number increased to 0.23, 0.27, 0.60 and 0.70 as the planting distance increased to $70{\times}15$, 20, 25 and 30 cm, respectively. At 2 plants per hill, the tiller number increased to 0.03, 0.03, 0.14 and 0.40 as the planting distance increased to $70{\times}15$, 20, 25 and 30 cm, respectively. At 1 plant per hill, the yield decreased to 6030, 4280, 3400 and $3230kg\;ha^{-1}$ as the planting distance increased. At 2 plant per hill, the yield decreased to 7850, 5770, 5720 and $4960kg\;ha^{-1}$ as the planting distance increased. We recommend that the optimum number of plants per hill and planting distance is 2 and $70{\times}25cm$ suitable for combine harvesting.

  • PDF

Effects of Skill and Distance Factors on Center of Mass and Center of Pressure during Golf Putting (골프 퍼팅 시 숙련도와 거리 요인이 신체 무게 중심과 압력 중심에 미치는 영향)

  • Park, JunSung;Lim, Young-Tae;Lee, JaeWoo;Kwon, Moon-Seok
    • Korean Journal of Applied Biomechanics
    • /
    • v.29 no.4
    • /
    • pp.205-211
    • /
    • 2019
  • Objective: The purpose of this study was to analyze the effects of skill and distance factors on CoP (Center of pressure) and CoM (Center of mass) during golf putting. Method: 38 golfers were participated in this study. 8 motion capture cameras (250 Hz) and 2 force plates (1,000 Hz) were used to collect CoP and CoM during 2 m and 3 m of distance golf putting. To identify main effect and interaction effect, it was performed Two-Way ANOVA at a significant level of a .05. Results: In the novice group, CoP distance was significantly difference in the A/P direction and main effect between skill level and distance. Both groups indicated that CoP distance was significantly different and main effect between skill level and distance in the M/L direction. Finally, both groups showed that CoM was significantly different and main effect between skill level and distance in the M/L direction. Conclusion: Therefore, novice golfers are expected to be able to perform more accurate and proper putting exercise through the practice of minimizing the center of mass(CoM) and center of pressure (CoP) in the M/L direction, which is the pendulum movement of the putter head.

Fabrication of Electrochemical Sensor with Tunable Electrode Distance

  • Yi, Yu-Heon;Park, Je-Kyun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.5 no.1
    • /
    • pp.30-37
    • /
    • 2005
  • We present an air bridge type electrode system with tunable electrode distance for detecting electroactive biomolecules. It is known that the narrower gap between electrode fingers, the higher sensitivity in IDA (interdigitated array) electrode. In previous researches on IDA electrode, narrower patterning required much precise and expensive equipment as the gap goes down to nanometer scale. In this paper, an improved method is suggested to replace nano gap pattering with downsizing electrode distance and showed that the patterning can be replaced by thickness control using metal deposition methods, such as electroplating or metal sputtering. The air bridge type electrode was completed by the following procedures: gold patterning for lower electrode, copper electroplating, gold deposition for upper electrode, photoresist patterning for gold film support, and copper etching for space formation. The thickness of copper electroplating is the distance between upper and lower electrodes. Because the growth rate of electroplating is $0.5{\mu}m\;min^{-1}$, the distance is tunable up to hundreds of nanometers. Completed electrodes on the same wafer had $5{\mu}m$ electrode distance. The gaps between fingers are 10, 20, 30, and $40{\mu}m$ and the widths of fingers are 10, 20, 30, 40, and $50{\mu}m$. The air bridge type electrode system showed better sensitivity than planar electrode.

ALL GENERALIZED PETERSEN GRAPHS ARE UNIT-DISTANCE GRAPHS

  • Zitnik, Arjana;Horvat, Boris;Pisanski, Tomaz
    • Journal of the Korean Mathematical Society
    • /
    • v.49 no.3
    • /
    • pp.475-491
    • /
    • 2012
  • In 1950 a class of generalized Petersen graphs was introduced by Coxeter and around 1970 popularized by Frucht, Graver and Watkins. The family of $I$-graphs mentioned in 1988 by Bouwer et al. represents a slight further albeit important generalization of the renowned Petersen graph. We show that each $I$-graph $I(n,j,k)$ admits a unit-distance representation in the Euclidean plane. This implies that each generalized Petersen graph admits a unit-distance representation in the Euclidean plane. In particular, we show that every $I$-graph $I(n,j,k)$ has an isomorphic $I$-graph that admits a unit-distance representation in the Euclidean plane with a $n$-fold rotational symmetry, with the exception of the families $I(n,j,j)$ and $I(12m,m,5m)$, $m{\geq}1$. We also provide unit-distance representations for these graphs.

An Investigation of Hazard Distance in a Series of Hydrogen Jet Fire with the Hyram Tools (수소 누출 시 제트화재 피해 범위에 대한 분석)

  • KANG, BYOUNG WOO;LEE, TAECK HONG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.28 no.2
    • /
    • pp.166-173
    • /
    • 2017
  • For commercialization of hydrogen refuelling station (HRS), we need to reduce the clearance distance for jet fire in the real entities in the HRS. Thus, we revisited the current regulations of clearance distance for jet fire in the law. The law in korea has been set up by replica of japan, not by our own scientific basis. Recently, sandia lab developed Hydrogen Risk Assessment Model (HyRAM) tools and we simulated a series of circumstances such as 10 to 850 bar with several leak hole sizes. In 850 bar with 10 mm diameter hole leak cases, it shows $4,981kW/m^2$ at 12 m separation from leak source and $1,774kW/m^2$ at 17 m separation from leak source. In 850 bar with 1 mm diameter leak hole, it shows $0.102kW/m^2$ at 12 m separation and $0.044kW/m^2$ at 17 m separation. Current law may be acceptable with 1 mm hole size with 850 bar.

A Study on the Scattered Dose in Portable Chest Radiography (portable 흉부촬영시 공간산란선량에 관한 연구)

  • Ahn, Bong-Seon;Lee, Hwan-Hyung
    • Journal of radiological science and technology
    • /
    • v.23 no.2
    • /
    • pp.63-67
    • /
    • 2000
  • The purpose of this study is to survey the present status of portable radiography and the result of free space scattered dose rate when taking a radiography at the general hospital or the university hospital in Taejon city. The results were as follows; 1. The number of cases using portable radiography for three years increased to averages 16.2%, 7.7% per year from January 1st in 1996 to December 31st in 1998. 2. The average of distance of adjacent patients was 219.1 cm at the ward. 3. For portable chest radiography, the free space scattered dose rate was 10.5 mSv/hr at 50 cm distance, 1.8 mSv/hr at 100 cm distance, and 0.2 mSv/hr at 200 cm distance. Therefore, in case of portable chest radiography at the ward, the average of distance of adjacent patients is 219.1 cm, so it does not have influence on the adjacent patients. But during the portable radiography, a guardian who is close to the patient, doctor, nurse and radiologic technologists has to set up the shield to prevent from the unnecessary radiation or the distance should be as great as possible from the mobile X-ray equipment.

  • PDF

Ship′s Distance Measuring System by the GPS Receiver in Anchoring Watch (GPS 선간거리계측 시스템에 의한 묘박상황의 감시)

  • 김광홍;신형일
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.37 no.4
    • /
    • pp.257-266
    • /
    • 2001
  • It was set up MCS and MS of ship's distance measuring system in land and ship respectively and ship's track including dropped and hove up anchor was tracked by mean of measurement for ship's position, relative bearing and distance from MCS to MS. Results analyzed for possibility of real time anchoring watch and effectiveness of measuring position are as follow; (1) The elapsed time from dropped anchor to hove up anchor is 4 minutes and the elapsed time to start recording ship's track after set up anchoring state is 10 minutes approximately. (2) Shape of hull's swing during anchoring is mostly 8 figue-like or rarely peanut-like shape. (3) Mean anchoring position during whole measuring time was shifted 49m north and 89m eastly. (4) Ship's track were moved counter-clockwise for $8.1^\circ$ range from relative bearing $186.1^\circ$ to $194.2^\circ$ ellipse-like tracks with the major axis 63m and the minor axis 53m. (5) High frequency of ship's position distribution was shown at relative bearing $187^\circ$ and distance 558m while low frequency was shown at relative bearing $194^\circ$ and distance 556m. (6) The designed ship's distance measuring system by PRTK-GPS was fit very well for anchoring watch as secured necessary area demanded for dragging anchor as well as anchoring by means of real time measurement both in distance and bearing.

  • PDF

A Study on the Inducement Distance of Senior-Friendly Park and Evaluation of Green Service Area - Focused on the Pedestrian Aspect - (보행적 측면에서 노인친화형 공원의 유치거리 도출 및 녹지서비스 지역 평가 - 보행자 측면 중심으로 -)

  • Cho, Hyunju;Lee, Soonju
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.47 no.1
    • /
    • pp.1-9
    • /
    • 2019
  • The objective of this study was to derive the served distance of the senior-friendly park considering physical changes, which were estimated through a comparison experiment at an actual target site. The time to walk 500m was examined because 500m is considered the served distance of a neighborhood park and as a standard set by the city. The mean walking time of the control group (younger than 65 years) was 536 seconds, while that of the treatment group (older than 65 years) was 889 seconds, which was approximately 1.7 times longer than the control group. The results of this study also showed that the walking time of females was longer than that of males when they were older than 65 years old. The walking velocities of the control group and the treatment groups were also calculated using the mean walking time. The weight estimated by a proportional formula was 0.6. When it was applied to 500m, which is the served distance of a neighborhood park, the served distance of the senior-friendly park was estimated as 300m. Lastly, the green service excluded area was quantified by applying the 300m, the served distance of a senior-friendly park, to the Jung-gu, Daegu, which had the highest elderly population in the Daegu Metropolitan City. The results of this calculation showed that the area served by a city park was $2,425,747m^2$ and the area excluded from the city park service was $4,627,700m^2$ for senior citizens. The results also showed that, in terms of the distributive equity, the administrative districts received unequal am ounts of urban green area services.

Prediction and development on technics of landslide prospecting by seismic refraction(PS-1) (소형 탄성파탐사기(PS-1)을 이용한 산사태예지기술개발)

  • 김재헌
    • Journal of the Korean Professional Engineers Association
    • /
    • v.25 no.4
    • /
    • pp.102-108
    • /
    • 1992
  • This study was carried to find out the soil characteristics of landslide site and to develope landslide prediction method by seismic refraction prospecting. For these aims, landslide condition and travel time were investigated at 68 Landslide sites over the country during 1990 to 1991. The results were as follows. 1. The surface of rupture was included mainly in C layer. Its Hardness was less than 3kg / $\textrm{cm}^2$ at the upper pare of landslide. 2. When the profile line length was 20m, the range of travel time was 40 to 90 msec. The travel time did not differ between bedrocks. 3. Refraction distance ranged from 1 to 7m and mean of that was 2.5m. Travel time was increased according to receiving distance without large variance in the refraction distance but that was appeared large variance out of the refraction distance on slope that has shallow soil depth and discontinuous ground surface. Therefore, the spread distance must be shorten to 10-l5m. 4. The seismic velocity at the first layer(layer of rupture) was less than 500m1sec by degree of weathering and the velocity at the second layer decreased in order of Granite> Granitic gneiss >Sedimentary rock. 5. The first layer observed by seismic refraction was contained C layer that has parent material and weathered rocks of hardness 10-20kg/$\textrm{cm}^2$. 6. Among the range of seismic velocity was less than 200m/sec in 63% of the total plots, 200-300m/sec in 34% and 300-500m /sec in 3%. 7. There was a proportional relationship between seismic prospecting soil depth and executive soil depth, and seismic propection soil depth was about 10 to 20cm deeper than the order.

  • PDF

Using Image J program, compared of focusing distance and grid rate (Image J 프로그램을 이용한 격자집속거리와 격자비에 따른 영상비교평가)

  • Seo, Won-Joo;Seo, Jeong-Beom;Lee, Jong-Woong
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.1
    • /
    • pp.37-42
    • /
    • 2012
  • Pediatric head and neck phantom, using the rate by focusing distance and grid images, Image J using the Quality Assessment and Dose Area Product compared. X-ray laboratory equipment due to the Philips Digital DIAGNOST a 110 cm FFD set and using ACE Non-grid, focusing distance 110 cm (12 : 1), 140 cm (12 : 1), 180 cm (8 : 1) Focused grid, Acryl Phantom (Fluke Model 76-2 Series Phantom) 15.24 cm, by resolution chart image acquisition, image evaluation program (Image J Ver. 1.4.3.67, USA) imaging experiments were analyzed using. Dose Area Product in the Non Grid 0.028 $mGy{\cdot}cm^2$, focusing distance 110 cm (12 : 1), the 0.129 $mGy{\cdot}cm^2$, 140 cm (12 : 1), the 0.135 $mGy{\cdot}cm^2$, 180 cm (8 : 1) was measured with a 0.110 $mGy{\cdot}cm^2$ Non Grid, focusing distance 110 cm (12 : 1), 140 cm (12 : 1), 180 cm (8 : 1) Image obtained when grid using the image J program focusing distance 110 cm with grid based on the measured SNR and PSNR Non Grid if the SNR the 17.307 dB, PSNR of the 20.002 dB, if the SNR 28.755 dB, PSNR was measured by the 31.451 dB. Image J image analysis through the streets, rather than focusing on grid by the rate that could see an increase in dose. Select the grid by a small dose rate reduction is possible.

  • PDF