Browse > Article
http://dx.doi.org/10.7316/KHNES.2017.28.2.166

An Investigation of Hazard Distance in a Series of Hydrogen Jet Fire with the Hyram Tools  

KANG, BYOUNG WOO (Department of green energy Engineering the Grad. School, Department of Chemical Engineering, Hoseo Univ)
LEE, TAECK HONG (Department of green energy Engineering the Grad. School, Department of Chemical Engineering, Hoseo Univ)
Publication Information
Transactions of the Korean hydrogen and new energy society / v.28, no.2, 2017 , pp. 166-173 More about this Journal
Abstract
For commercialization of hydrogen refuelling station (HRS), we need to reduce the clearance distance for jet fire in the real entities in the HRS. Thus, we revisited the current regulations of clearance distance for jet fire in the law. The law in korea has been set up by replica of japan, not by our own scientific basis. Recently, sandia lab developed Hydrogen Risk Assessment Model (HyRAM) tools and we simulated a series of circumstances such as 10 to 850 bar with several leak hole sizes. In 850 bar with 10 mm diameter hole leak cases, it shows $4,981kW/m^2$ at 12 m separation from leak source and $1,774kW/m^2$ at 17 m separation from leak source. In 850 bar with 1 mm diameter leak hole, it shows $0.102kW/m^2$ at 12 m separation and $0.044kW/m^2$ at 17 m separation. Current law may be acceptable with 1 mm hole size with 850 bar.
Keywords
Jet fire; Hydrogen risk assessment model; Hydrogen refuelling station; Hydrogen; Hazard distance;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 S. H. Joo, "Quantitative Hazards Assessment Based on PHAST on Explosion Effects of Hydrogen Station", M.S. Dissertation, the Grad. School of Hoseo Univ., 2016, p. 11.
2 J. S. Ko, "Study on Probabilistic Analysis for Fire . Explosion Accidents of LPG Vaporizer with Jet Fire", J. Kor. Inst. Fire Sci. Eng., Vol. 26, No. 4, 2012, pp. 31-41.
3 W. Houf and R. Schefer, "Predicting radiative heat fluxes and flammability envelopes from unintended releases of hydrogen," International Journal of Hydrogen Energy, Vol. 32, No. 1, 2007, pp. 136-151.   DOI
4 K. H. Moo, D. S. Kim, J. H. Choi, and J. K. Kim, "FMEA and FTA for Reliability Analysis of Hybrid Rocket Motor", Journal of the Korean Society for Aviation and Aeronautics, Vol. 21, No. 4, 2013, p. 28.
5 J. R. Kwon and others, "A Study on the Optimization Model Development of On-Site Hydrogen Refuelling Station", Korea Gas Safety Corporation, 2010, KGS 2011, p. 40.
6 Y. D. Jo and B. J. Ahn, "Analysis of Hazard Area Associated with Hydrogen Gas Transmission Pipelines", International Journal of Hydrogen Energy, Vol. 31, No. 14, 2006, pp. 2122-2130.   DOI
7 J. LaChance, "Risk-informed separation distances for hydrogen refuelling stations", International Journal of Hydrogen Energy, Vol. 34, 2009, pp. 5838-5845.   DOI
8 Y. D. Jo, "Hazard Distance from Hydrogen Accidents". Journal of the Korean Institute of Gas, Vol. 16, No. 1, 2012, pp. 15-21.   DOI