• 제목/요약/키워드: 1D Signal

검색결과 2,493건 처리시간 0.027초

E-band low-noise amplifier MMIC with impedance-controllable filter using SiGe 130-nm BiCMOS technology

  • Chang, Woojin;Lee, Jong-Min;Kim, Seong-Il;Lee, Sang-Heung;Kang, Dong Min
    • ETRI Journal
    • /
    • 제42권5호
    • /
    • pp.781-789
    • /
    • 2020
  • In this study, an E-band low-noise amplifier (LNA) monolithic microwave integrated circuit (MMIC) has been designed using silicon-germanium 130-nm bipolar complementary metal-oxide-semiconductor technology to suppress unwanted signal gain outside operating frequencies and improve the signal gain and noise figures at operating frequencies. The proposed impedance-controllable filter has series (Rs) and parallel (Rp) resistors instead of a conventional inductor-capacitor (L-C) filter without any resistor in an interstage matching circuit. Using the impedance-controllable filter instead of the conventional L-C filter, the unwanted high signal gains of the designed E-band LNA at frequencies of 54 GHz to 57 GHz are suppressed by 8 dB to 12 dB from 24 dB to 26 dB to 12 dB to 18 dB. The small-signal gain S21 at the operating frequencies of 70 GHz to 95 GHz are only decreased by 1.4 dB to 2.4 dB from 21.6 dB to 25.4 dB to 19.2 dB to 24.0 dB. The fabricated E-band LNA MMIC with the proposed filter has a measured S21 of 16 dB to 21 dB, input matching (S11) of -14 dB to -5 dB, and output matching (S22) of -19 dB to -4 dB at E-band operating frequencies of 70 GHz to 95 GHz.

고출력 위협신호 모의장치 개발 및 추적레이다 연동 (Development of High power Threat Signal Simulator and Interfacing Tracking Radar)

  • 곽용길
    • 한국항행학회논문지
    • /
    • 제26권2호
    • /
    • pp.85-90
    • /
    • 2022
  • 본 연구에서는 항공기 체계의 성능을 시험하기 위해 시험 대상 항공기에 실제 위협과 유사한 신호를 고출력으로 송신할 수 있는 위협신호 모의 장치를 설계하였다. 고출력 위협신호 모의장치는 광대역(UHF대역, L대역, S대역, X 대역)의 통신신호, 레이다 신호를 송신하는 것이 가능해야 하며, 추적 레이다와 연동을 통해 항공기에 정확하게 지향하여 신호를 송신하는 제어시스템이 필요하다. 개발된 장비의 신호의 세기는 신호의 종류에 따라서 63 dBm, 93 dBm이상이며, 추적 정밀도는 0.1°이하로 요구되는 전기적/기계적 성능을 모두 만족함을 확인하였고, 추적 레이다 연동을 통해 고출력 위협신호 모의장치의 안테나가 항공기 위치로 신호를 정확하게 지향할 수 있음을 확인하였다.

삼각 섬유성 연골(TFCC) 손상 환자의 자기공명영상 검사 시 Fat Suppressed 3D FSPGR T1 강조 기법에 대한 Fat Suppressed Isotropic 3D FSE T1 강조 기법의 비교 분석 및 유용성에 관한 평가 (The Comparative Analysis Study and Usability Assessment of Fat Suppressed 3D FSPGR T1 Technique and Fat Suppressed Isotropic 3D FSE T1 Technique when Examining MRI of Patient with Triangular Fibrocartilage Complex (TFCC) Tear)

  • 강성진;조용근;이성수
    • 한국자기학회지
    • /
    • 제26권3호
    • /
    • pp.105-114
    • /
    • 2016
  • 삼각 섬유성 연골(TFCC) 손상 환자의 평가를 위하여 fat suppressed 3D fast spoiled gradient recalled T1 기법과 fat suppressed Isotropic 3D fast spin echo T1 기법을 이용하여 영상을 획득하였다. 정량적 평가를 위해 각각의 영상에서 signal to noise ratio 및 contrast to noise ratio 값을 측정하고, Mann-Whitney U 검정으로 두 기법 간의 통계적 유의성을 검증하였다. 또한 정성적 평가를 위해 영상의학의 2명이 각각의 영상을 관찰하여, TFCC의 형태, 영상 내 인공음영, 병변의 묘사 정도의 3가지 항목을 선정한 후 이를 4점 척도(0: 진단 불가, 1: 부족함, 2: 충분함, 3: 좋음)로 평가하였고, Kappa-value 검정을 이용하여 두 관찰자 간의 일치도 검증을 하였다. 영상획득에는 3.0 Tesla MR 장비와 8-channel RF coil을 사용하였다. 정량적 평가 결과, 모든 영상 단면에서 signal to noise ratio 및 contrast to noise ratio 값이 Isotropic 3D fast spin echo T1 기법이 높게 나타났으며, Mann-Whitney U 검정을 이용한 두 영상기법 간의 검증도 통계적으로도 유의하였다(p < 0.05). 정성적 평가 결과, 관찰자 1, 2 모두에서 Isotropic 3D fast spin echo T1 기법의 평가 결과가 더 높게 나타났으며, Kappa-value 검증을 이용한 두 관찰자 간 평가 결과의 일치도 검증도 통계적으로 유의하였다(p < 0.05). 결론적으로 TFCC 손상 환자의 자기공명영상 검사 시 fat suppressed Isotropic 3D fast spin echo T1 기법의 적용은 TFCC 병변의 감별에 보다 유용한 진단적 정보를 제공 할 수 있을 것이라 생각된다.

강제 동기식 4생체 4채널 광펠레미트리시스템 구현 (Implementation of four-subject four-channel optical telemetry system with enforced synchronization)

  • 박종대;손진우;서희돈
    • 전자공학회논문지D
    • /
    • 제35D권7호
    • /
    • pp.40-47
    • /
    • 1998
  • This paper presents the physiological signal processing CMOS one chip for transmitting human bodys small electrical signals such as electrocardiogram(EKG) or electromyogram(EMG) and the external system for receiving signals was implemented by the commercial ICs. For simultaneous four-subject four-channel telemetry, a new enfored synchronization techniqeu using infrared bi-directional communication has been proposed. The telemeter IC with the size of 5.1*5.1mm$^{2}$ has the following functions: receiving of command signal, initialization of internal state of all functional blocks, decoding of subject-selection signal, time multiplexing of 4-channel modulated physiological signals, transmitting of telemetry signal to external system and auto power down control. The newly designed synchronized oscillator with low supply voltage dependence in the telemeter IC operates at a supply voltage from 4.6~6.0V and the nonlinearity error of PIM modulator was less than 1.2%F.S(full scale). The power saving block operates at the period of 2.5ms even if the telemetry IC does not receive command signal from external system for a constant time.

  • PDF

DTV 신호 측정용 표준 안테나 개발 (Development of Standard Antenna for DTV Signal Measurement)

  • 권원현;김준식;박영신;김영택
    • 대한전자공학회논문지TC
    • /
    • 제44권1호
    • /
    • pp.18-23
    • /
    • 2007
  • 본 연구에서는 DTV 전파환경 및 수신환경 측정용 기준 안테나를 LPDA 안테나를 이용하여 개발하였다. 안테나의 재질은 측정 장치 구성 및 해체 시의 기구적 견고성을 확보하고 가벼운 시스템 구성이 가능하도록 Element 및 본체를 두랄루민으로 제작하였으며, 동작 주파수 $450\;{\sim}\;850$ MHz에서 안테나 이득은 FCC 규정치인 10 dBd 이상이 되도록 설계하였다. 개발된 안테나는 전 대역에서 10 dBd 이상 (평균 11.7dBd)의 이득 특성과 ${\pm}1.5$ dB의 우수한 통과특성을 지녀 수신환경 측정용 표준안테나로 적합하다.

10-Bit 200-MS/s Current-Steering DAC Using Data-Dependant Current-Cell Clock-Gating

  • Yang, Byung-Do;Seo, Bo-Seok
    • ETRI Journal
    • /
    • 제35권1호
    • /
    • pp.158-161
    • /
    • 2013
  • This letter proposes a low-power current-steering digital-to-analog converter (DAC). The proposed DAC reduces the clock power by cutting the clock signal to the current-source cells in which the data will not be changed. The 10-bit DAC is implemented using a $0.13-{\mu}m$ CMOS process with $V_{DD}$=1.2 V. Its area is $0.21\;mm^2$. It consumes 4.46 mW at a 1-MHz signal frequency and 200-MHz sampling rate. The clock power is reduced to 30.9% and 36.2% of a conventional DAC at 1.25-MHz and 10-MHz signal frequencies, respectively. The measured spurious free dynamic ranges are 72.8 dB and 56.1 dB at 1-MHz and 50-MHz signal frequencies, respectively.

자유 공간 광통신 시스템에서 신호 변동 억제를 위한 전광 자동 이득 조절 어븀 첨가 광섬유 증폭기의 성능 평가 (Performance Evaluation of an All-optical Automatic Gain-controlled Erbium-doped Fiber Amplifier for Suppression of Signal Fluctuation in Terrestrial Free-space Optical Communication Systems)

  • 정유석;김철한
    • 한국광학회지
    • /
    • 제33권3호
    • /
    • pp.99-105
    • /
    • 2022
  • 자유 공간 광통신 시스템에서 발생하는 대기 외란에 의한 광신호 변동을 억제하기 위하여 전광(all-optical) 자동 이득 조절(automatic gain controlled, AGC) 어븀 첨가 광섬유 증폭기(erbium-doped fiber amplifier, EDFA)를 활용할 때의 성능을 실험적으로 평가하였다. EDFA에 입력되는 광신호 입력을 -30 dBm과 -10 dBm으로 각각 설정하여 증폭기가 소 신호 영역과 포화 영역에서 동작할 때의 성능을 실험적으로 비교하였다. 이 때 광신호의 요동은 음향 광학 변조기(acousto-optic modulator, AOM)를 활용하여 구현하였다. 실험 결과로부터 EDFA가 소 신호 영역에서 동작하며, 피드백되는 증폭된 자발 방출(amplified spontaneous emission, ASE) 광 전력이 0 dBm으로 증폭기를 포화시킬 수 있는 경우에 가장 작은 광신호 요동 특성을 얻을 수 있음을 확인하였다.

A Compact Ka-Band Doppler Radar Sensor for Remote Human Vital Signal Detection

  • Han, Janghoon;Kim, Jeong-Geun;Hong, Songcheol
    • Journal of electromagnetic engineering and science
    • /
    • 제12권4호
    • /
    • pp.234-239
    • /
    • 2012
  • This paper presents a compact K-band Doppler radar sensor for human vital signal detection that uses a radar configuration with only single coupler. The proposed radar front-end configuration can reduce the chip size and the additional RF power loss. The radar front-end IC is composed of a Lange coupler, VCO, and single balanced mixer. The oscillation frequency of the VCO is from 27.3 to 27.8 GHz. The phase noise of the VCO is -91.2 dBc/Hz at a 1 MHz offset frequency, and the output power is -4.8 dBm. The conversion gain of the mixer is about 11 dB. The chip size is $0.89{\times}1.47mm^2$. The compact Ka-band Doppler radar system was developed in order to demonstrate remote human vital signal detection. The radar system consists of a Ka-band Doppler radar module with a $2{\times}2$ patch array antenna, baseband signal conditioning block, DAQ system, and signal processing program. The front-end module size is $2.5{\times}2.5cm^2$. The proposed radar sensor can properly capture a human heartbeat and respiration rate at the distance of 50 cm.

전력소자 응용을 위한 4H-SiC MESFET 대신호 모텔링 (4H-SiC MESFET Large Signal modeling for Power device application)

  • 이수웅;송남진;범진욱;안철
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 하계종합학술대회 논문집(2)
    • /
    • pp.229-232
    • /
    • 2001
  • Modified Materka-Kacprzak 대신호 MESFET(Metal Semiconductor Field Effect Transistor) model을 사용하여 4H-SiC MESFET의 대신호 모델링을 수행하였다. Silvaco사의 소자 시뮬레이터인 ATLAS를 사용하여 4H-SiC MESFET 소자 시뮬레이션을 수행하고, 이 절과를 modified Materka 대신호 모델을 사용하여 모델링 하였다. 시뮬레이션 및 모델링 결과는 -8V의 pinch off 전압과 V/sub GS=0V, V/sub DS=25V에서 I/sub DSS=270㎃/㎜, G/sub m=45㎳/㎜를 얻을 수 있었고, 진력 특성 시뮬레이션을 통해 2㎓, V/sub GS=-4V, V/sub DS=25V에서 1()dB의 Gain과 34dBm(1dB compression point)의 출력전력, 7.6W/㎜의 전력밀도, 37%의 PAE(power added efficiency)를 얻을 수 있었다.

  • PDF

심전도 신호의 전력선 잡음 제거를 위한 Deep De-noising Network 설계 (Design of Deep De-nosing Network for Power Line Artifact in Electrocardiogram)

  • 권오윤;이지은;권준환;임성준;유선국
    • 한국멀티미디어학회논문지
    • /
    • 제23권3호
    • /
    • pp.402-411
    • /
    • 2020
  • Power line noise in electrocardiogram signals makes it difficult to diagnose cardiovascular disease. ECG signals without power line noise are needed to increase the accuracy of diagnosis. In this paper, it is proposed DNN(Deep Neural Network) model to remove the power line noise in ECG. The proposed model is learned with noisy ECG, and clean ECG. Performance of the proposed model were performed in various environments(varying amplitude, frequency change, real-time amplitude change). The evaluation used signal-to-noise ratio and root mean square error (RMSE). The difference in evaluation metrics between the noisy ECG signals and the de-noising ECG signals can demonstrate effectiveness as the de-noising model. The proposed DNN model learning result was a decrease in RMSE 0.0224dB and a increase in signal-to-noise ratio 1.048dB. The results performed in various environments showed a decrease in RMSE 1.7672dB and a increase in signal-to-noise ratio 15.1879dB in amplitude changes, a decrease in RMSE 0.0823dB and a increase in signal-to-noise ratio 4.9287dB in frequency changes. Finally, in real-time amplitude changes, RMSE was decreased 0.3886dB and signal-to-noise ratio was increased 11.4536dB. Thus, it was shown that the proposed DNN model can de-noise power line noise in ECG.