• Title/Summary/Keyword: 18-crown-6

Search Result 257, Processing Time 0.032 seconds

Effect of Alkali Metal Ions on Alkaline Ethanolysis of 2-Pyridyl and 4-Pyridyl Benzoates in Anhydrous Ethanol

  • Lee, Jae-In;Kang, Ji-Sun;Kim, Song-I;Um, Ik-Hwan
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.10
    • /
    • pp.2929-2933
    • /
    • 2010
  • Pseudo-first-order rate constants ($k_{obsd}$) have been measured for nucleophilic substitution reactions of 2-pyridyl benzoate 5 with alkali metal ethoxides (EtOM, M = Li, Na, K) in anhydrous ethanol. The plots of $k_{obsd}$ vs. $[EtOM]_o$ are curved upwardly but linear in the excess presence of 18-crown-6-ether (18C6) with significant decreased $k_{obsd}$ values in the reaction with EtOK. The $k_{obsd}$ value for the reaction of 5 with a given EtONa concentration decreases steeply upon addition of 15-crown-5-ether (15C5) to the reaction medium up to ca. [15C5]/$[EtONa]_o$ = 1, and remains nearly constant thereafter, indicating that $M^+$ ions catalyze the reaction in the absence of the complexing agents. Dissection $k_{obsd}$ into $k_{EtO^-}$- and $k_{EtOM}$, i.e., the second-order rate constants for the reaction with the dissociated $EtO^-$ and the ion-paired EtOM, respectively has revealed that ion-paired EtOM is 3.2 - 4.6 times more reactive than dissociated $EtO^-$. It has been concluded that $M^+$ ions increase the electrophilicity of the reaction center through a 6-membered cyclic transition state. This idea has been examined from the corresponding reactions of 4-pyridyl benzoate 6, which cannot form such a 6-membered cyclic transition state.

Accuracy of provisional crowns made using stereolithography apparatus and subtractive technique

  • Kang, Seen-Young;Park, Jung-Hyun;Kim, Ji-Hwan;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.5
    • /
    • pp.354-360
    • /
    • 2018
  • PURPOSE. To compare and analyze trueness and precision of provisional crowns made using stereolithography apparatus and subtractive technology. MATERIALS AND METHODS. Digital impressions were made using a master model and an intraoral scanner and the crowns were designed with CAD software; in total, 22 crowns were produced. After superimposing CAD design data and scan data using a 3D program, quantitative and qualitative data were obtained for analysis of trueness and precision. Statistical analysis was performed using normality test combined with Levene test for equal variance analysis and independent sample t-test. Type 1 error was set at 0.05. RESULTS. Trueness for the outer and inner surfaces of the SLA crown (SLAC) were $49.6{\pm}9.3{\mu}m$ and $22.5{\pm}5.1{\mu}m$, respectively, and those of the subtractive crown (SUBC) were $31.8{\pm}7.5{\mu}m$ and $14.6{\pm}1.2{\mu}m$, respectively. Precision values for the outer and inner surfaces of the SLAC were $18.7{\pm}6.2{\mu}m$ and $26.9{\pm}8.5{\mu}m$, and those of the SUBC were $25.4{\pm}3.1{\mu}m$ and $13.8{\pm}0.6{\mu}m$, respectively. Trueness values for the outer and inner surfaces of the SLAC and SUBC showed statistically significant differences (P<.001). Precision for the inner surface showed significance (P<.03), whereas that for the outer surface showed no significance (P<.58). CONCLUSION. The study demonstrates that provisional crowns produced by subtractive technology are superior to crowns fabricated by stereolithography in terms of accuracy.

A CLINICAL STUDY OF TRAUMATlC INJURIES OF ANTERIOR TEETH (전치부 외상에 대한 임상적 고찰)

  • Park, Sang-Duk
    • Restorative Dentistry and Endodontics
    • /
    • v.7 no.1
    • /
    • pp.33-40
    • /
    • 1981
  • The more civilized, the more incidence had happened in our daily life, particularly in industrial factories, by traffic accident, and in sports, etc. in the dental field. The accidental trauma is usually involved the teeth and surronuding tissues. And the author intended to study of the traumatic injuries of anterior teeth by individual tooth, age, sex, cause of trauma, and how they were treated. The following results were obtained: 1. The patients with traumatic injuries of the anterior teeth were 1.8% among the total dental out-patients. 2. By the age group, the twenties was most frequent in both sexes, and the teenagers next. 3. The predominant causes of traumatic injuries in the dental field were traffic accident (23.4%), fighting (19.2%), falling (18.5%), and sports (7.3%). 4. In the classification of injuries of the teeth, uncomplicated crown fractures (31.2%), subluxations (14.7%), and the complicated crown fractures (13.2%) were presented. 5. By the individual tooth in the traumatic cases, the upper cental incisors were most frequently injuried (49.8%). 6. In the treatments fillings and endodontic treatments (33.2%), splints (13.5%), extractions (11.7%) were main after care method.

  • PDF

The compressive fracture strength of ceromer crown by the difference of occlusal thickness (Ceromer crown의 교합면 두께에 따른 압축 파절 강도의 비교)

  • Kim, Jee-Yeon;Park, Ha-Ok;Yang, Hong-So
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.18 no.3
    • /
    • pp.205-215
    • /
    • 2002
  • This study investigated the compressive fracture strength of Targis ceromer crown by the difference of occlusal thickness on a maxillary first premolar. Control group was a castable IPS-Empress all-ceramic crown with occlusal thickness of 1.5 mm constructed by layered technique. Experimental groups were Targis crowns having different occlusal thicknesses of 1.0 mm, 1.5 mm, 2.0 mm, 2.5 mm, respectively. The classification of Targis group is T10, T15, T20, T25 and T15N (for no-thermocycling and occlusal thickness of 1.5mm). Ten samples were tested per each group. Except occlusal thickness, all dimension of metal die is same with axial inclination of $10^{\circ}$and marginal width 0.8mm chamfer. All crowns were cemented with Panavia F and thermocycled 1,000 times between $5^{\circ}$ and $55^{\circ}$ water bath with 10 sec dwelling time and 10 sec resting time. The compressive fracture strength was measured by universal testing machine. The results were as follows : 1. Fracture strength was increased as the occlusal thickness increased : compressive fracture strength of Group T10, T15, T20, T25 was $66.65{\pm}4.88kgf$, $75.04{\pm}3.01kgf$, $87.07{\pm}7.06kgf$ and $105.03{\pm}10.56kgf$, respectively. 2. When comparing material, Targis crown had higher fracture strength than IPS-Empress crown : the mean compressive strength of group T15 was $75.04{\pm}3.01kgf$ and the value of group Control was $37.66{\pm}4.28kgf$. 3. Fracture strength was decreased by thermocycling : the compressive fracture strength of T15 was $75.04{\pm}3.01kgf$, which is lower than $90.69{\pm}6.88kgf$ of group T15N. 4. The fracture line of crowns began at the loading point and extended along long axis of tooth. IPS-Empress showed adhesive failure pattern whereas Targis had adhesive and cohesive failure. In the SEM view, stress was distributed radially from loading point and the crack line was more prominent on Targis crown.

A Study on Satisfaction of Practicing Dentists about Prosthesis in Pusan Part I : About Fixed Prosthetic appliances (부산지역(釜山地域) 개업치과(開業齒科)의 치과보철물(齒科補綴物)에 관(關)한 만족도(滿足度) 조사(調査)(I) - 일부정식 치과 보철물에 관하여 -)

  • Lee, Myung-Kon
    • Journal of Technologic Dentistry
    • /
    • v.10 no.1
    • /
    • pp.159-169
    • /
    • 1988
  • Fixed prosthetic appliance is the restorations of damaged teeth with cast metal or porcelain, and of replacing missing teeth with fixed, or cemented prosthesis. Successfully treating a patient by means of fixed prosthodontics requires the thoughtful combination of dentist and dental laboratory technician. In order to know the satisfaction of dentisits about fixed prosthetic appliances-porcelain, precious and non precious metal-, this study was conducted for 69 practicing dentisis in Pusan during Fed. to Mar. 1988 using a questionnaire method and was analyzed by the use of percentage, $X^2$-test The results are obtained as follow: 1. General characteristics of the respondents, The rate of age distribution of practcing dentists responded was as follow : 31$\sim$35 age group is 29.0%, 51$\sim$55age group 18.8%, 41$\sim$45 age group and 46$\sim$50 group each 11.6%, 36$\sim$40 age group and 56$\sim$60 age group 8.7%, over 60 age group 7.3%, below 30 age group 4.3% respectively. The tate of term of practice experience distribution of dentists responded was as follow : 6$\sim$10 year group 26.1%, 25$\sim$25year group 18.8%, 11$\sim$15 years group and 16~20 years group each 13.0%, below 5 years group and over 30 years group each 10.2%, 26$\sim$30 years group 8.7% in order. The rate of respondents’ degree was follow : bachelor group 81.2%, doctor group 13.0%, master group 5.8% in order. The rate of respondents’completed medical specialist course was as follow : non-complete group 75.4%, complete group 24.6%. The rate of having own laboratory in respondents’clinic was as follow : no having own laboratory group 58.0%, having own labiratory group 42.0% The rate of being lab. technician in respondent;s clinic was as follow: non-being lab. technician group 91.3%, being lab. technician group 8.7%. The rate of transactional commercial dental lab. numbers was as follow : I dental lab. group 40.6%, 2 dental lab. group 30.4%, 3 dental lab. group 20.3%, production at own lab. group 8.7% 2. Cognitions about the respondent's job, About cognition of patient numvers, there were neither many nor few group 62.3%, few group 17.4%, many group 15.9%, too many group 4.4% in order.(P<.01) As compared with the ratio of dentists to patient prothetic treatment, there were moderate level group 46.4%, high level group 33.6%, low level group 18.8% in order.(P<.01) By job satisfaction of respondents, the highest percentage group was satisfied group 44.9%, neither astisfied nor disstified group 33.3%, dissatisfied group 14.5%, much satisfied group 7.3%(P<.01). As compared with the level of prosthetics price, the were moderate level group 71.0%, low level group 23.2%, high level group 5.8%(P<.01) 3. Satisfaction and assessment of dissatisfied factor of the fixed prosthetic appliance, As compared with the satisfaction of al prosthetic appliance, there were neither satisfied nor dissatisfied group 59.4%, satisfied group 20.3% dissatisfied group 18.8%, much satisfied group 1.5% in order.(P<.01). About precious and non precious metal crown and bridge, there were neither satisfied nor dissatisfied group 60.9%, satisfied group 24.6%, dissatisfied group 11.6%, much satisfied group 2.9% in order.(P<.01) The reat of respondent;s satisfaction about porcelain crown and bridge was as follow : neither satisfied nor dissatisfied group 43.5%, dissatisfied group 33.3%, satisfied group 21.7%, much satisfied group 1.5%(P<.01). The rate of respondent's dissatisfied factor item of precious and non precious metal crown and bridge was as follow : inadequate margin fit item 39.1% respondent, inadequate occlusion item 24.6%, inadequate adaptation item 23.2%, poor anat omic form item 15.9%, inadequate contact item 31.9%, improper polishing item 4.4%, the rest item 11.6% respectively. The rate of respondent's dissatisfied factor item of porcelain crown and bridge was as follow : inadequate margin fit item 52.2%, inadequate occlusion item 2.9%, inadequate adaptation item 10.1%, poor anatomic form item 11.6%, improper polishing item 1.5%, shade mismatching item 71%, the rest item 7.2% respectively. The rate of cognition of respondents’ about cause of dissatisfied factor on fixed prosthetic appliance by item was as follow : deficiency of sincerity item 55.1%, deficiency of knowledge about work item 47.8%, deficiency of experience item 15.9%, poor quality of using material item 5.8%, the rest item 2.9% respectively.

  • PDF

Beta-carotene and Lutein Contents in Green Leafy Vegetables (녹색잎 채소류의 ${\beta}$-Carotene과 Lutein 함량)

  • Lee, Hwa-Suk;Kim, Young-Nam
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.7 no.2
    • /
    • pp.175-180
    • /
    • 1997
  • Beta-carotene and lutein contents in 7 different green leafy vegetables(perilla leaf, mugwort, chwi, lettuce, spinach, leek, and crown daisy) were analyzed by HPLC. The isocratic separation was performed on a ${\mu}-Bondapak$ $C_{18}$ column with a solvent system of acetonitrile : dichloromethane : methanol = 70:20:10. To check the reliability of the method applied, precision and recovery tests were performed. Perilla leaf showed the highest ${\beta}-carotene$ content(12,570 ${\mu}g$ / 100 g), followed by mugwort and chwi, all of those have ${\le}10,000\{\mu}g\{\beta}-carotene$ per 100 g vegetables. Green lettuce, spinach, leek, crown daisy and reddish brown lettuce contained 9,869, 6,689, 5,664, 3,601 and 3,299 ${\mu}g\{\beta}-carotene/100 g$, respectively, Lutein content was the highest in perilla leaf($13,718{\mu}g/100 g$) followed by chwi($11,989{\mu}g/100 g$), mugwort($11,522{\mu}g/100 g$), green lettuce($10,307{\mu}g/100 g$) and spinach($10,115{\mu}g/100 g$). ${\beta}-carotene$ contents in perilla leaf, mugwort, chwi and green lettuce were 47.8~49.6% of total carotenoids, and ${\beta}-carotene$ contents in the other green leafy vegetables analyzed were 37.7~41.4% Vitamin A contents of green leafy vegetables analyzed by HPLC were 2~6 times higher than the vitamin A values shown in food composition tables except crown daisy.

  • PDF

Solvent-free Microwave-Assisted Ortho-Alkylation of Aromatic Ketimine with Acrylic Acid Derivatives by Rh(I) Catalyst

  • Jo, Eun-Ae;Ahn, Jeong-Ae;Jun, Chul-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.11
    • /
    • pp.2020-2024
    • /
    • 2007
  • The article reports the synthesis of a novel bispyridino-18-crown-6 ether, 7-{[(5S,15S)-5,15-diphenyl- 3,6,14,17-tetraoxa-23,24-diazatricyclo[17.3.1.18,12]tetracosa-1(23),8(24),9,11,19,21-hexaen-10-yl]oxy}heptylferrocenamide 6, bearing the C2-symmetric diphenyl substituents as chiral barriers and the ferrocenyl groups serving as an electrochemical sensor, and its electrochemical study with D- and L-AlaOMe·HCl as the guest by cyclovoltametry.

Structure direct agent-assisted hydrothermal synthesis and small gases adsorption behavior of pure RHO zeolite (구조유도물질 18-crown-6 ether를 이용한 순수한 RHO 제올라이트 수열합성과 작은 가스 흡착 거동)

  • Kim, Beom-Ju;Sharma, Pankaj;Han, Moon-Hee;Cho, Churl-Hee
    • Journal of Energy Engineering
    • /
    • v.23 no.4
    • /
    • pp.141-149
    • /
    • 2014
  • In the present study, pure RHO zeolite was hydrothermally synthesized by using 18-crown-6 ether as a structure directing agent(SDA), and the small gases adsorption was investigated. Synthesized RHO zeolite was a cube shape particle of which average edge length was around $1.2{\mu}m$ and composed of primary crystallites having a diameter of around 100 to 200 nm. RHO zeolite structure was stable under 3h calcination at $600^{\circ}C$. Water adsorption data announced that RHO zeolite has a specific surface area of 483.32 m2/g and its micropore diameter was about 4 A. Gas adsorption was studied in the pressure range of 50 to 500 kPa for $CO_2$, $N_2$, $O_2$ and $H_2$. It was evident that RHO zeolite showed a strong $CO_2$ adsorption behavior. Especially, RHO zeolite showed a transient $CO_2$ adsorption behavior. The 3h $CO_2$ up-take at 50 kPa and 500 kPa was 1.283 and 3.357 mmol/g, respectively. The $CO_2/H_2$ selectivity was around 16 at 500 kPa. Compared with gas adsorption data for some representative microporous adsorbents, it was certain that RHO zeolite is a beneficial adsorbent for $CO_2/H_2$ separation.

Competitive Solvent Extraction of Alkali Metal Ions with Azacrown Ether Phosphinic Acids (아자크라운에테르포스피닉산에 의한 알카리금속이온의 경쟁용매추출)

  • Nam, Chong-Woo;Chung, Yeong-Jin;Yang, Il-Woo
    • Applied Chemistry for Engineering
    • /
    • v.3 no.2
    • /
    • pp.266-272
    • /
    • 1992
  • Azacrownoalkyl phenylphosphinic acids were synthesized and their competitive solvent extraction characteristics from water to chloroform layer were investigated. Phosphinic acids were synthesized in good yields by one step reaction of phenylphosphinate, aldehyde, and monoazacrown ether and then basic hydrolysis of the resulting phosphinate dsters. These complexing agents revealed a wide effective pH range in extraction of alkali metal ions from water to the organic phase and total metal ion loading at pH 11 was about 75%. The selectivity of the cation extraction was determined mainly by the cavity size of the azacrown ethers, showing $Na^+$ >> $K^+$ > $Rb^+$ > $Li^+$ > $Cs^+$ for the alkyl phenylphosphinic acid ${\underline{2}}$, containing monoaza-15-crown-5 and $K^+$ >> $Rb^+$ > $Na^+$ > $Cs^+$ > $Li^+$ for the alkyl phenylphosphinic acid, ${\underline{3}}$, containing monoaza-18-crown-6 moiety. Applicable pH range of these azacrown ether phosphinic acids in solvent extraction of alkali metal cations was wider than a crownether carboxylic acid with similar selectivity, showing considerable amount of metal ion loading in slightly acidic or neutral media.

  • PDF

The Formative Characteristics of Hats Shown in Prêt-à-porter Collection (프레타포르테 컬렉션에 나타난 모자의 조형적 특성)

  • Yoo, Hyun Jeong;Kim, Jeong Mee
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.18 no.4
    • /
    • pp.141-158
    • /
    • 2016
  • The objective of this study is to examine the type and characteristics of hat, and also to analyze the formative characteristics of hats shown in $Pr{\hat{e}}t-{\grave{a}}$-porter Collection. The literature review focused on the relevant technical books and preceding researches while the case study targeted 1,561 photos of hats shown in the 'Donga TV Collection'. The research range was from the S/S season of 2012 to the F/W season of 2015/16. The results of this study are as follows. 1. A hat is composed of crown and brim. In the results of classifying hats based on it, there were 572 crown-type hats, 533 hat-type, 219 cap-type, 156 irregular-type, and 81 brim-type in the order. 2. For the crown-type hats, they were mainly like cylindrical-type, bell-type, dome-type, and circle-type, using colors like black, beige, brown, red, mustard, and grey, and materials like wool, fur, velvet, straw, and metal while they were decorated with bead or lace. 3. For the hat-type hats, they were mainly like bell-type, ladder-type, and hemisphere-type, using colors like peach, white, gold, brown, and khaki, and materials like silk, cotton, straw, and wool while they were decorated with feather and ribbon. 4. For the cap-type hats, they were mainly like hemisphere-type, using colors like white, black, khaki, mustard, and purple, and materials like fur, leather, and wool while they were decorated with wappen and chain. 5. For the irregular-type hats, they were mainly like sandglass-type, box-type, animal-type, trumpet-type, and bell-type, using colors like purple, orange, pink, yellow, and sky-blue, and materials like metal, feather, mesh, plastic, straw, and linen while they were decorated with ribbon, net, bell, and flower. 6. For the brim-type visor, they were mainly like square-type, using colors like transparent, yellow, and black, and materials like plastic, cotton, leather, and metal.

  • PDF