• 제목/요약/키워드: 154

검색결과 7,010건 처리시간 0.03초

Platelets Induce Proliferation of Human Umbilical Vein Endothelial Cells via CD154-CD40 Pathway Independently of VEGF

  • Cho, Wha-Jung;Ko, Eun-Mi;Cheon, In-Su;Jeoung, Doo-Il;Kim, Young-Myeong;Choe, Jong-Seon
    • IMMUNE NETWORK
    • /
    • 제8권3호
    • /
    • pp.75-81
    • /
    • 2008
  • Background: Platelets take part in repairing the lesions of endothelial damage. To understand the molecular mechanism of this process, we tested the hypothesis that CD154 expressed on activated platelets stimulates proliferation of human endothelial cells. Methods: The expression levels of CD154 and CD40 on platelets and endothelial cells, respectively, were measured by flow cytometry and confocal microscopy. Function-blocking monoclonal antibody against CD154 was developed after immunization with CD154-transfected L cells. Results: An anti-CD40 agonist antibody and soluble CD154 both induced significant proliferation of endothelial cells. In addition, a function-blocking anti-CD154 antibody inhibited the platelet-induced proliferation of endothelial cells, indicating that the CD154-CD40 pathway is involved in these cellular interactions. An anti-VEGF antibody failed to inhibit the proliferation. This, in addition to the fact that very small amounts of VEGF are released from platelets or endothelial cells, suggests that VEGF does not play an important role in the platelet-stimulated proliferation of endothelial cells. Conclusion: Our results indicate that platelets induce proliferation of endothelial cells by CD154-CD40 interactions independently of VEGF.

국내 345kV 변전소 하위 154kV 계통 연계지점 SFCL 적용방안에 관한 연구 (A study on SFCL application for 154kV power system interconnection of 345kV S/S in Korean power system)

  • 이승렬;김종율;윤재영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.340-343
    • /
    • 2005
  • This paper is for studying the feasibility of SFCL application for the interconnection operation of 154kV power systems under 345kV S/S in Korean power system. All Korean 154kV power systems are constructed as loop systems in downtown. However, the present 154kV systems are operated with separated systems around 345kV S/S because of fault current and overload problems. In this study, we investigate the structure and operation of 154kV power system in Seoul and study the feasibility of interconnection operation of 154kV systems under 345kV systmes by applying SFCLs to 154kV bus-tie.

  • PDF

A study on SFCL application for the interconnection operation of 154kV power systems under 345kV S/S in Korean power system

  • Lee Seung Ryul;Kim Jong Yul;Yoon Jae Young
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제7권2호
    • /
    • pp.47-51
    • /
    • 2005
  • This paper is for studying the feasibility of SFCL application for the interconnection operation of 154kV power systems under 345kV S/S in Korean power system. All Korean 154kV power systems are constructed as loop systems in downtown. However, the present 154kV systems are operated with separated systems around 345kV S/S because of fault current and overload problems. In this study, we investigate the structure and operation of 154kV power system in Seoul and study the feasibility of interconnection operation of 154kV systems under 345kV systmes by applying SFCLs to 154kV bus-tie.

154kV 송전선로 Arcing Horn 적용에 따른 애자련 사고분석 (Analysis of Insulator Failures Altar Installation of Arcing Horns in 154kV Transmission Lines)

  • 조성배;이형권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1743-1745
    • /
    • 1998
  • Insulators of 154kV T/L have been frequently damaged by fault currents. Arcing horn is a very effective and economic method for protection of insulators from the flashover. We developed arcing horns for 154kV T/L in order to protect insulators from the arc[1]. This paper analyzes the status of insulator failures in 154kV T/L after installation of the arcing horns.

  • PDF

154KV계 직접접지시의 절연협조 (Study on insulation coordination of 154KV solidly grounded system)

  • 신대승
    • 전기의세계
    • /
    • 제17권3호
    • /
    • pp.57-61
    • /
    • 1968
  • Limitation to Peterson coil grounded operation of 154KV system began to develop with the growth of system as to voltage and system cost. Therefore, 154KV system is going to be grounded solidly from November this year. This study shows the insulation coordination of solidly ground system, such as the selection of a suitable lightening arrester, determination of transmission line insulation and Basic Insulation Level of station equipment.

  • PDF

Toluene내성세균 Pseudomonas sp. BCNU 154을 이용한 방향족화합물의 분해 (Biodegradation of Aromatic Hydrocarbons by Toluene-tolerant Pseudomonas sp. BCNU 154)

  • 성은미;정영기;이호원;주우홍
    • 생명과학회지
    • /
    • 제9권6호
    • /
    • pp.715-721
    • /
    • 1999
  • 분리된 toluene내성세균 Pseudomonas sp. BCNU 154을 생물분해반응에 적용하고저 그 가능성을 조사하였다. 방향 족화합물 16개을 대상으로 저화능을 조사한 결과 cumene, cyclohexane, ethylbenzene, p-xylen, m-xylen, toluene 그리고 diphenylether가 공시균쥬에 의해 자화됨이 확인 되었다. Pseudomonas sp. BCNU 154는 toluene, ethylbenzene 그리고 p-xylen 그리고 cumene을 호기적으로 분해하였다. Touene은 12시간후에 완전히 분해되었고, p-xylene과 cumene은 12시간배양시 90% 분해되었으며, ethylbenzene은 12시간 배양시 75%가 분해되었다.

  • PDF

22/154kV급 XLPE의 유전특성과 절연열화 (Degradation and Dielectric Properties of 22/154kV XLPE sheets)

  • 이관우;이종복;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 연구회
    • /
    • pp.84-87
    • /
    • 2001
  • In this paper, degradation and dielectric properties of XLPE sheets moved from 22/154kV power cables were investigated. At the results of dielectric property of 22kV/154kV XLPE sheet, We earned that $tan{\delta}$ is $7.4{\times}10^{-4}$, $2.15{\times}10^{-4}$ and dielectric constant is 2.3, 2.24. Temperature dependance of $tan{\delta}$ inclined to increasing with temperature and increase of $tan{\delta}$ of 22kV XLPE sheet is higher than it of 154kV XLPE sheet. And increasement of XLPE sheet with water is higher than it without water.

  • PDF

수요분석을 통한 154kV 계통전압 유지기준 설정 (An examination on proper voltage operation standard for 154kV power system through demand analysis)

  • 이익종;이상중
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 춘계학술대회 논문집
    • /
    • pp.428-431
    • /
    • 2009
  • 안정적인 전력계통 운영을 위한 공급전압별 유지기준의 설정은 대단히 중요하다. 유지기준은 현재 정부고시로 제정 운영되고 있다. 우리나라의 공급전압은 345kV-154kV-22.9kV 및 380V-220V-110V로 구성되어 있다. 본 논문에서는 전기품질 유지관리에 영향을 주는 계통전압 중, 154kV를 중심으로 수요분석을 통해 유지기준이 적정한지를 살펴보고 이를 토대로 현재의 전력계통 수요에 적합한 유지기준을 고찰해 보고자 한다.

  • PDF

Bacillus thringiensis var. kurstaki 감온성 돌연변이주의 일부특성 (Partial Characterization of Bacillus thuringiensis var. kurstaki Temperature-sensitive Mutants)

  • 김영권;유관희;이형환;이호원
    • 미생물학회지
    • /
    • 제23권3호
    • /
    • pp.203-208
    • /
    • 1985
  • Bacillu! thuringiensis var. krustaki 3ab k-3의 감온성치사돌연변이체에 대한 생물학적 성상의 변이성의 차이를 조사하고 유전적 특성을 규명하기 위하여 생화학적 성상검사, 항생제에 대한 감수성 조사, 용혈성 검사, 돌연변이체균주의 특수배지에서의 성장비교, Mouse에 대한 치사효과를 $28^{\circ}C$의 허용온도에서 조사하였다. Urease를 생산하지 못하는 돌연변이체는 ts-U154, ts-U601, ts-U602, ts-U603, ts-U604, t-U788 이었다. ts-U603만이 운동성이 상실되었고, ts-U154는 Salicin과 cellobiose을 분해하지 못했고, ribose를 분해하지 않는 균주는 ts-U603였다. 항생제에 대한 반응은 ampicillin, cephalothin, penicillin에는 모두 저항성을 나타냈으나, ts-U154 균주만이 감수성을 나타냈다. Fructus gardenia배지에서 색소를 생산하지 않은 것은 ts-U21, ts-U74, ts-U131과 ts-U154였다 가장 적은 용혈성을 나타내는 균주는 정상형고 ts-U602였고 가장 많은 용혈성을 나타내는 것은 ts-U603 (1:512 x) 이었다. Mouse 에 대한 치사효과는 전혀 없었다.

  • PDF

Pseudomonas sp. BCNU 154 유래의 유기용매 내성 리파아제 (Organic Solvent-tolerant Lipase from Pseudomonas sp. BCNU 154)

  • 최혜정;황민정;서정윤;주우홍
    • 생명과학회지
    • /
    • 제23권10호
    • /
    • pp.1246-1251
    • /
    • 2013
  • 산업공단지역의 폐수에서 분리한 유기용매 내성 Pseudomonas sp. BCNU 154 리파아제의 최적조건은 $37^{\circ}C$, pH8로 조사되었다. BCNU 154의 crude 리파아제는 toluene에서 2시간 반응시 효소활성 약 6.01 U/ml (117.53%)로 가장 안정한 것으로 나타났다. 한편 $Ca^{2+}$, $Mg^{2+}$, $NH_4{^+}$, $Na^+$ 이온 및 triton X-100은 효소를 활성화시킨 반면에 $Ba^{2+}$, $Hg^{2+}$$Zn^{2+}$ 이온은 효소활성을 억제하였다. Pseudomonas sp. BCNU 154 리파아제는 상용 고정화 효소인 Novozym 435와 비교해서도 안정한 활성을 보였다. 그러므로 유기용매 내성 리파아제는 별도의 고정화 처리없이도 화학산업공정에서 가능성 있는 whole cell 생물촉매로서 유용할 것으로 판단된다.