• Title/Summary/Keyword: 12-step method

Search Result 683, Processing Time 0.026 seconds

Study on Performance Evaluation of Dental X-ray Equipment (치과 방사선 발생기의 성능평가에 관한 연구)

  • Jung, Jae-Eun;Jung, Jae-Ho;Kang, Hee-Doo;Lee, Jong-Woong;Ra, Keuk-Hwan
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.11 no.2
    • /
    • pp.115-119
    • /
    • 2009
  • I think this will be valuable reference for assuring consistency and homogeneity of clarity and managing dental radiation equipment by experimentation of dental radiation equipment permanent which based on KS C IEC 61223-3-4 standard and KS C IEC 61223-2-7. Put a dental radiation generator and experiment equipment as source and film(sensor) length within 30 em, place the step-wedge above the film(sensor). Tie up tube voltage 60 kVp, tube current 7 mA and then get an each image through CCD sensor and film by changing the exposure time as 0.12sec, 0.25sec, 0.4sec. Repeat the test 5times as a same method. Measure the concentration of each stage of film image, which gained by experiment, using photometer. And the image that gained by CCD sensor, analyze the pixel value's change by using image J, which is analyzing image program provided by NIH(National Institutes of Health). In case of film, while 0.12sec and 0.25sec show regular rising pattern of density gap as exposure time's increase, 0.4sec shows low rather than 0.12sec and 0.25sec. In case of CCD sensor density test, the result shows opposite pattern of film. This makes me think that pixels of CCD's sensor can have 0~255 value but it becomes saturation if the value is over 255. The way that getting clear reception during decreasing human's exposed radiation is one of maintaining an equipment as a best condition. So we should keeping a dental radiation equipment's condition steadily through cyclic permanent test after factor examination. Even digital equipment doesn't maintain a permanent, it can maintain a clarity by post processing of image so that hard to set it as standard of permanent test. Therefore it would be more increase the accuracy that compare a film as standard image. Thus I consider it will be an important measurement to care for dental radiation equipment and warrant homogeneity, consistency of dental image's clarity through comparing pattern which is the result from factor test against cyclic permanent test.

  • PDF

Synthesis of Hectorite by Hydrothemal Method (저온 수열법에 의한 헥토라이트 합성)

  • Jang, Young-Nam;Chae, Soo-Chun;Ryu, Gyoung-Won;Kim, You-Dong;Jang, Hee-Dong;Bae, In-Kook
    • Journal of the Mineralogical Society of Korea
    • /
    • v.20 no.1 s.51
    • /
    • pp.1-6
    • /
    • 2007
  • Hectorite was synthesized by a two-step hydrothermal process from $Mg(OH)_{2}$, water glass (${\sim}30\;wt%\;SiO_{2}$) and Li-compound at $90{\pm}5^{\circ}C$. The product shows excellent dispersion and swelling properties. The mixture of the starting materials was heated in a glass vessel for the first reaction with continuous stirring and the pH of the solution was adjusted to $6{\sim}8$, resulting in the formation of a precursor of hectorite. The excess salt components were washed out from the resulting slurry and then was matured in the glass vessel for the 2nd reaction. Li compound was added during the reaction. After a 10 h retention, the gel of hectorite was formed. The XRD pattern of the synthesized one was coincided with that of natural hectorite and SEM study revealed uniform grains 50 m in diameter. The d001 basal spacing of the product moved from 12 to $17.4\;{\AA}$ after glycolation treatment. The measured value of CEC and the swelling capacity was 90 cmol/kg and $60{\sim}70\;mL/2\;g$, respectively.

A Mobile Payment System Based-on an Automatic Random-Number Generation in the Virtual Machine (VM의 자동 변수 생성 방식 기반 모바일 지급결제 시스템)

  • Kang, Kyoung-Suk;Min, Sang-Won;Shim, Sang-Beom
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.12 no.6
    • /
    • pp.367-378
    • /
    • 2006
  • A mobile phone has became as a payment tool in e-commerce and on-line banking areas. This trend of a payment system using various types of mobile devices is rapidly growing, especially in the Internet transaction and small-money payment. Hence, there will be a need to define its standard for secure and safe payment technology. In this thesis, we consider the service types of the current mobile payments and the authentication method, investigate the disadvantages, problems and their solutions for smart and secure payment. Also, we propose a novel authentication method which is easily adopted without modification and addition of the existed mobile hardware platform. Also, we present a simple implementation as a demonstration version. Based on virtual machine (VM) approach, the proposed model is to use a pseudo-random number which is confirmed by the VM in a user's mobile phone and then is sent to the authentication site. This is more secure and safe rather than use of a random number received by the previous SMS. For this payment operation, a user should register the serial number at the first step after downloading the VM software, by which can prevent the illegal payment use by a mobile copy-phone. Compared with the previous SMS approach, the proposed method can reduce the amount of packet size to 30% as well as the time. Therefore, the VM-based method is superior to the previous approaches in the viewpoint of security, packet size and transaction time.

Planarization of SUS310 Metal Substrate Used for Coated Conductor Substrate by Chemical Solution Coating Method (화학적인 용액 코팅방법에 의한 박막형 고온초전도체에 사용되는 SUS310 금속모재의 평탄화 연구)

  • Lee, J.B.;Lee, H.J.;Kim, B.J.;Kwon, B.K.;Kim, S.J.;Lee, J.S.;Lee, C.Y.;Moon, S.H.;Lee, H.G.;Hong, G.W.
    • Progress in Superconductivity
    • /
    • v.12 no.2
    • /
    • pp.118-123
    • /
    • 2011
  • The properties of $2^{nd}$ generation high temperature superconducting wire, coated conductor strongly depend on the quality of superconducting oxide layer and property of metal substrate is one of the most important factors affecting the quality of coated conductor. Good mechanical and chemical stability at high temperature are required to maintain the initial integrity during the various process steps required to deposit several layers consisting coated conductor. And substrate need to be nonmagnetic to reduce magnetization loss for ac application. Hastelloy and stainless steel are the most suitable alloys for metal substrate. One of the obstacles in using stainless steel as substrate for coated conductor is its difficulties in making smooth surface inevitable for depositing good IBAD layer. Conventional method involves several steps such as electro polishing, deposition of $Al_2O_3$ and $Y_2O_3$ before IBAD process. Chemical solution deposition method can simplify those steps into one step process having uniformity in large area. In this research, we tried to improve the surface roughness of stainless steel(SUS310). The precursor coating solution was synthesized by using yttrium complex. The viscosity of coating solution and heat treatment condition were optimized for smooth surface. A smooth amorphous $Y_2O_3$ thin film suitable for IBAD process was coated on SUS310 tape. The surface roughness was improved from 40nm to 1.8 nm by 4 coatings. The IBAD-MgO layer deposited on prepared substrate showed good in plane alignment(${\Delta}{\phi}$) of $6.2^{\circ}$.

Evaluation of the Effect of the Arrhythmia Correction for the Image Quality in the Multidetector-Row Computed Tomography (MDCT) Coronary Angiography (Multidetector-Row Computed Tomography (MDCT) Coronary Agniography에서 Arrhythmia Correction이 영상의 질에 미치는 영향에 관한 연구)

  • Kim, Hyun-Soo;Kim, Keung-Sik;Kim, Tae-Hoon;Yoo, Beong-Gyu
    • Journal of radiological science and technology
    • /
    • v.27 no.2
    • /
    • pp.7-12
    • /
    • 2004
  • MDCT is a useful, non-invasive, diagnostic tool in the evaluation of coronary artery disease. However, the image quality is affected by an irregular heart rhythm of the patients. Especially, premature ventricular contraction induced stair-step artifacts in the reconstruction of 2-D or 3-D images of the heart including coronary arteries. In recent, we experienced some improving of the image quality after correcting the PVC. Accordingly, the purpose of our study was to evaluate the effectiveness of the arrhythmia correction method, which was commercially available software, in improving the quality of the reconstruction images of the heart. Image analysis was performed, in consensus, by two radiologists. The scores for image quality were ranked as follows; excellent is 4 (image quality is markedly improved and is helpful in the image evaluation), good is 3 (image quality is mildly improved, but is somewhat helpful in the image evaluation), fair is 2 (image quality is improved and is not helpful in the image evaluation), and poor is 1 (image quality is not improved). We used ANOVA method to evaluate the statistical significant differences in the image qualities among the correction methods of the arrhythmia with below 0.05 of p-value. The method of moving the R-R interval showed statistically significant differences in improving of the image quality in patients with arrhythmia. We concluded that the regulation of R-R interval in patients with arrhythmia was an effective method to improve the image quality in the reconstructions of the MDCT coronary angiograms.

  • PDF

Effect of moisture on sealing ability of root canal filling with different types of sealer through the glucose penetration model (수종의 실러를 이용한 근관 충전 시 근관 내 수분이 치근단 폐쇄효과에 미치는 영향)

  • Jang, Jin-Ah;Kim, Hee-Lyang;Her, Mi-Ja;Lee, Kwang-Won;Yu, Mi-Kyung
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.5
    • /
    • pp.335-343
    • /
    • 2010
  • Objectives: To compared the effect of different levels of moisture of root canal on the sealing ability after filling with four different types of sealer. Materials and Methods: Single-rooted teeth (n = 90) instrumented to and apical size of 0.06 / 45 were randomly assigned to 12 experimental groups (n = 7 per group), positive/negative control groups (n = 3 per group). The teeth of the experimental groups (a. DRY; b. PAPER POINT DRY; c. WET) were obturated with sealer (Group 1-3: Sealapex; Group 4-6: AH plus; Group 7-9: Tubuli-seal; Group 10-12: EndoRez) and warm vertical compaction method. After 7 days in $37^{\circ}C$, 100% humidity, the coronal-to-apical microleakage was evaluated quantitatively using a glucose leakage model. The leaked glucose concentration was measured with spectrophotometer at 1, 3, 7, 14, 21, and 30 days. Data were recorded ad mmol/L and statistically analysed with the two-way ANOVA and Duncan test (p = 0.05). Results: Throughout the experimental period Tubuli-seal/WET (Group 9) showed the highest mean cumulative glucose penetration (178.75 mmol/L), whereas AH plus/DRY (Group 4) had the least (20.78 mmol/L). Conclusions: The results of this study demonstrated that the moisture condition of root canals at the time of obturation and the type of sealer that was used had a significant effect on leakage and sealing ability. Thus drying procedure according to sealer types is a critical step and should not be missed in endodontic treatment.

A Method for Storativity Compensation in Single Well Test Analysis (단공시험 해석에서 저류계수의 보정방법)

  • Choi, Byong-Soo
    • Journal of Soil and Groundwater Environment
    • /
    • v.12 no.3
    • /
    • pp.36-43
    • /
    • 2007
  • In the case of single well pumping tests the storativities are generally overestimated. To compensate these errors, the effective wellbore radius should be introduced as a distance to an imaginary observation well in the time-drawdown analysis. Effective wellbore radius can be calculated through step drawdown tests or using skin factor equation. But both are of trial-and-error methods guessing real storativity values and, therefor, are difficult to apply to the field conditions. An equation was developed to estimate effective wellbore radius from storativity values obtained from pumping well data. For this study, a total of 136 time-drawdown data set were used to derive the equation. The effective wellbore radius were estimated first by changing them till the storativity values obtained from the pumping-well data match the ones based on the observation-well data. Then the equation was regressed from the relation between effective wellbore radius and the storativity values obtained from the pumping-well data. It is believed that the equation would be useful in estimating effective wellbore radius from the single well tests.

Cloning, Sequencing and Expression of apxIA, IIA, IIIA of Actinobacillus pleuropneumoniae Isolated in Korea (국내 분리 흉막폐렴균의 apxIA, IIA, IIIA 유전자 Cloning, 염기서열 분석 및 단백질 발현)

  • Shin, Sung-jae;Cho, Young-wook;Yoo, Han-sang
    • Korean Journal of Veterinary Research
    • /
    • v.43 no.2
    • /
    • pp.247-253
    • /
    • 2003
  • Actinobacillus pleuropneumoniae causes a highly contagious pleuropneumoniae in swine. The bacterium produces several virulence factors such as exotoxin, LPS, capsular polysaccharide, etc. Among them, the exotoxin, called Apx, has been focused as the major virulence factor, and the toxin consists of 4 gene cluster. apx CABD. apxA is the structural gene of toxin and has four different types, I, II, III, and IV. As the first step of development of a new subunit vaccine, the three different types of apxA gene were amplified from A. pleuropneumoniae isolated from Korea by PCR with primer designed based on the N- and C-terminal of the toxin. The sizes of apxIA, IIA and IIIA were 3,073, 2,971 and 3,159bps, respectively. The comparison of whole DNA sequences of apxIA, IIA and IIIA genes with those of the reference strain demonstrated 98%, 99% and 98% homology, respectively. In addition, the phylogenetic analysis was performed based on the amino acid sequences compared with 12 different RTX toxin family using the neighbor-joining method. ApxA proteins of Korean isolates were identical with reference strains in this study. All ApxA proteins were expressed in E. coli with pQE expression vector and identified using Western blot with polyclonal antibodies against culture supernatants of A. pleuropneumoniae serotype 2 or 5. The sizes of each expressed ApxA protein were about 120, 110, 125 kDa (M.W.), respectively. The results obtained in this study could be used for the future study to develop a new vaccine to porcine pleuropneumoniae.

A Comparative Study of a Dielectric-Defined Process on AlGaAs/InGaAs/GaAs PHEMTs

  • Lim, Jong-Won;Ahn, Ho-Kyun;Ji, Hong-Gu;Chang, Woo-Jin;Mun, Jae-Kyoung;Kim, Hae-Cheon;Cho, Kyoung-Ik
    • ETRI Journal
    • /
    • v.27 no.3
    • /
    • pp.304-311
    • /
    • 2005
  • We report on the fabrication of an AlGaAs/InGaAs/GaAs pseudomorphic high electron mobility transistor (PHEMT) using a dielectric-defined process. This process was utilized to fabricate $0.12\;{\mu}m\;{\times}\;100 {\mu}m$ T-gate PHEMTs. A two-step etch process was performed to define the gate footprint in the $SiN_x$. The $SiN_x$ was etched either by dry etching alone or using a combination of wet and dry etching. The gate recessing was done in three steps: a wet etching for removal of the damaged surface layer, a dry etching for the narrow recess, and wet etching. A structure for the top of the T-gate consisting of a wide head part and a narrow lower layer part has been employed, taking advantage of the large cross-sectional area of the gate and its mechanically stable structure. From s-parameter data of up to 50 GHz, an extrapolated cut-off frequency of as high as 104 GHz was obtained. When comparing sample C (combination of wet and dry etching for the $SiN_x$) with sample A (dry etching for the $SiN_x$), we observed an 62.5% increase of the cut-off frequency. This is believed to be due to considerable decreases of the gate-source and gate-drain capacitances. This improvement in RF performance can be understood in terms of the decrease in parasitic capacitances, which is due to the use of the dielectric and the gate recess etching method.

  • PDF

Application of Polyurethane Foam Loaded with a Schiff Base Ligand for Determination of Trace Amounts of Copper in Water Samples by Flame Atomic Absorption Spectroscopy

  • Moftakhar, Mahdieh Koorehpazan;Yaftian, Mohammad Reza;Nahaei, Samaneh;Zamani, Abbas Ali
    • Journal of the Korean Chemical Society
    • /
    • v.58 no.3
    • /
    • pp.283-288
    • /
    • 2014
  • A column solid phase extraction procedure based on modified polyurethane foam (PUF) by a newly synthesized Schiff base ionophore, named 2,2'-{iminobis[propane-3,1-diylnitrilo(1E)prop-1-yl-1-ylidene]}diphenol, was developed for preconcentration step of trace amounts determination of copper ions in water samples by atomic absorption flame spectroscopy. The influence of parameters on the adsorption process such as sample pH, amount of modified PUF packed in the column, type and volume of stripping reagent and its flow rate were investigated and optimized. Under optimum experimental conditions, the calibration graph was linear in a relatively wide range ($0.005-210{\mu}g/ml$) with a limit of detection $0.002{\mu}g/ml$ of copper. The proposed method allows achieving to a concentration factor of >133. The capacity of a column (1.6 cm i.d.) packed by 6 g of PUF modified by 12 mg of the Schiff base was found to be $247.7({\pm}2.1){\mu}g$ of copper. It was found that the adsorption process was highly selective towards copper ions with respect to some associated metal ions. The presented procedure was successfully applied for determination of copper in some water samples.