• Title/Summary/Keyword: 1064 nm

Search Result 140, Processing Time 0.021 seconds

The First Hyperpolarizability $\beta$ measurement of octupoles at 1560 nm and 1064nm (1560nm와 1064nm를 이용한 옥타폴 분자의 1차 초분극율 $\beta$ 측정)

  • 정미윤;이상해;조봉래;전승준
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.02a
    • /
    • pp.24-25
    • /
    • 2003
  • 새로이 합성된 비선형 광학 물질인 옥타폴 분자들의 1차 초분극율ß을 Hyper-Rayleigh scattering(HRS) 방법을 이용하여 측정하였다. 시료의 흡수와 형광효과를 피하기 위해, 광원으로 1560nm를 사용하였다. YAG(1064nm) 레이저로 펌핑한 Raman-Cell(D$_2$ gas) 장치를 제작하여, 높고 안정한 파워의 1560nm를 발생하여 실험에 사용하였다. 또한 1064nm를 이용하여 측정한 결과와 비교하였다. (중략)

  • PDF

Lidar Measurement of Asian Dust and Analysis of Optical Parameter using 1064 nm, 532 nm Wavelength (1064 nm, 532 nm 파장을 이용한 황사의 라이다 관측과 광학적 파라메타의 해석)

  • 김진환;박찬봉;이주희
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.02a
    • /
    • pp.214-215
    • /
    • 2003
  • 2002년 수원상공의 황사를 라이다를 이용하여 관측하고, 이의 광학적 특성을 보고한다. 기상청의 1월부터 5월까지의 황사보고는 16일로 예년에 비해 많이 발생하였고, 특히 11년만에 11월에 황사가 발생하여 사회적으로 많은 관심이 되었다. 본 라이다센터에서는 2002년 3월부터 대류권을 관측하는 자동운전 에어로졸 라이다(ACA Lidar, 532 nm)를 운전하여 집중적으로 황사를 관측하였고 2002년 10월부터는 1064 nm 파장을 추가하여 많은 관련 데이터를 생산하였다. (중략)

  • PDF

Combined Effects of Different Wavelength Laser Stimulations and Electroacupuncture on Neuropathic Pain (파장별 레이저 자극과 전침 결합 시술이 신경병리성 동통에 미치는 영향)

  • Cho, Myoung-rae;Kim, Myeong-hun;Moon, Youngmin;Jeong, Sungho;Na, Chang-su
    • Korean Journal of Acupuncture
    • /
    • v.38 no.3
    • /
    • pp.151-161
    • /
    • 2021
  • Objectives : The effects of a combined stimulation of 658 nm, 830 nm, 904 nm, and 1064 nm laser acupuncture treatment (LAT) and electroacupuncture treatment (EAT) on GB39 and GB34 on neuropathic pain in rats induced by tibial and sural nerve transection were studied in this paper. Methods : To express a neuropathic pain model, surgery was performed to transection rats' tibial and sural nerves. The rats were divided into normal group, control group, and experimental groups. In addition, the experimental groups were divided into 658 nm laser and electroacupuncture (LAT658+EAT), 830 nm laser and electroacupuncture (LAT830+EAT), 904 nm laser and electroacupuncture (LAT904+EAT), and 1064 nm laser and electroacupuncture (LAT830+EAT). For the treatment of the experimental groups, electroacupuncture and different laser wavelengths were alternately applied to GB34 and GB39 twice a week for 3 weeks for 1 minute 30 seconds. The withdrawal response of neuropathic rats' legs by acetone stimulation was observed, as well as the c-Fos in the central gray region in the midbrain of neuropathic rats together with Bax, Bcl2, and mGluR5 expressions associated with apoptosis. Results : Compared with the control group, a significant decrease in the frequency of paw withdrawal in response to acetone allodynia was observed in LAT658+EAT and LAT830+EAT groups in 6th times, LAT904+EAT group in 2nd, 3rd, and 6th times, and LAT1064+EAT group in 2nd and 6th times, respectively. For c-fos positive cells in the central gray region, a significant decrease was observed in LAT830+EAT, LAT904+EAT, and LAT1064+EAT groups in comparison with the control group. In Bax expression, LAT1064+EAT group showed a significant decrease compared to the control group. In Bcl-2 expression, the LAT658+EAT,the LAT904+EAT, and the LAT1064+EAT groups increased significantly compared to the control group. LAT830+EAT, LAT904+EAT, and LAT1064+EAT groups showed significantly increased mGlu5 expression compared to the control group. Conclusions : The combination of laser for each wavelength and electroacupuncture alternately performed in this study is thought to be effective in improving neuropathic pain and apoptosis.

Micromachining & Optical Properties of Li$_2$O-A1$_2$O$_3$-SiO$_2$ Glass System by Laser Treatment (레이저에 의한 Li$_2$O-A1$_2$O$_3$-SiO$_2$계 유리의 미세가공 및 광학적 특성)

  • 강원호
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.8 no.4
    • /
    • pp.43-45
    • /
    • 2001
  • For photosensitive and micro-structuring in $Li_2O-A1_2O_3-SiO_2$glasses by laser treatment, Nd:YAG laser in 355 nm and 1064 nm wavelength was irradiated to the glass to investigate fracture characterization and optical changes. The fractured glass surfaces irradiated by 1064 nm laser was observed by Scanning Electron Microscope(SEM) and optical microscope, and optical changes caused by 355 nm later was identified from absorption spectra. In this study, it could be expected that the laser treatment technology will be utilized for 3-dimensional micro-structure, internal waveguide, optical memory by optical absorption changes in glass matrix.

  • PDF

Effects of Laser Acupuncture Therapy According to the Wavelength at GB34·GB39 on Neuropathic Pain Rat Induced by Tibial and Sural Nerve Transection (양릉천(GB34)·현종(GB39)에 대한 파장대별 레이저침 시술이 동통에 미치는 영향)

  • Youn, Daehwan;Yoo, Pyungsik;Kim, Wangin;Kim, Mirea;Choi, Donghee;Na, Changsu
    • Korean Journal of Acupuncture
    • /
    • v.31 no.4
    • /
    • pp.195-207
    • /
    • 2014
  • Objectives : The purpose of this study is to examine the effects of laser acupuncture according to the wavelength(532 nm, 650 nm, 830 nm, 904 nm, and 1064 nm) at the acupoint of GB34 GB39 on neuropathic pain rat induced by tibial and sural nerve transection(TST). Methods : Neuropathic pain in rats was induced by tibial nerve and sural nerve transection. The rats were divided into the intact group, the TST control group, and the laser acupuncture therapy group. The laser acupuncture therapy groups were then divided into subgroups with 532 nm(L532), 650 nm(L650), 830 nm(L830), 904 nm(L904), and 1064 nm(L1064) laser acupuncture therapy. The acupoint of GB34 GB39 was selected, and laser acupuncture therapy was provided on both sides alternatively twice a week in a total of 6 sessions. Results : All the laser acupuncture groups showed a significant decrease in reaction time and force intensity. L532, L904, and L1064 groups showed a significant decrease in Bax, the L532 group showed a significant increase in Bcl-2, L532 and L1064 groups showed a significant decrease in the Bax/Bcl-2 ratio, and L532 and L650 groups showed a significant increase in mGluR5, as compared with the TST control group, among nerve tissue reaction. Conclusions : These results showed that laser acupuncture therapy at each of the wavelengths had some significance on neuropathic pain.

Development of the 2~8X Zoom Beam Expander for the 1064 nm Laser Source (1064 nm 레이저 관원용 2~8X 줌 빔 확대기 개발)

  • Yi, Meyung-Ha;Lee. Dong-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.2
    • /
    • pp.23-28
    • /
    • 2008
  • Purpose: To develop the 2~8X zoom beam expander for the 1064 nm laser source. Methods: After developing the program by which the initial design values of 3-component zoom tracks can be quickly obtaind, we design and develop the zoom beam expander by applying this program and the commercial program of Sigma 2000. Results: In this study, we could develop the program by which the initial design values of zoom tracks can be quickly obtaind, and by applying this program and the commercial program of Sigma 2000 we could design and develop the zoom beam expander for 1064 nm which is able to zoom from 2${\times}$ to 8${\times}$. The developed zoom beam expander has an efficient diameter of the incidence side of 8 mm, an efficient diameter of the exit side of 32 mm, and a capacity with the finite ray aberration within 0.0001rad. Because the overall length (OAL) is restricted between 125 mm and 135 mm, the change of the whole barrel length which is caused by variations of the zoom driving becomes to be within 10 mm. Conclusions: we could develop the program by which the initial design values of zoom tracks can be quickly obtaind, and by applying this program we could design and develop the zoom beam expander for 1064 nm which is able to zoom from 2${\times}$ to 8${\times}$.

  • PDF

Measurements of the Second Harmonic Coefficients of the Ferroelectric Polymer P(VDP-TrFE)(72/28 mole%) at 1064 and 532 nm Wavelength (강유전성 고분자 P(VDF-TrFE)(72/28 mole%)의 파장 1064 및 532 nm에 대한 2차 비선형 광학 계수 측정)

  • 정창수;임종선;박광서;김도석;이범구
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2001.02a
    • /
    • pp.232-233
    • /
    • 2001
  • 2차 비선형광학 물질이 높은 응용성을 갖기 위해서는 큰 2차 비선형광학 계수뿐만 아니라 넓은 파장 영역에 걸친 투명성을 가지고 있어야 한다. vinylidene fluoride(VDF)와 trifluoroethylene(TrFE)가 공중합된 f(VDf-TrFE) 공중합체는 이러한 조건을 갖추고 있는 강유전성 물질이다. 우리는 몰비율이 72:28인 P(VDF-TrFE)을 ITO기판위에 casting하고 corona 극화한 뒤, 두 개의 입력 파장(1064nm, 532nm)에 대한 2차 조화파 발생 실험을 실시하고 Herman과 Hayden의 마커무의 식을 이용하여 2차 비선형 광학 계수를 측정하였다. (중략)

  • PDF

Visualization of Temperature Distribution Deep Inside the Agar Gel Tissue Phantom Heated Using Moxibustion and 1064 nm Infrared Laser (쑥뜸과 1064 nm 파장의 근적외선 레이저로 가열된 아가젤 조직 팬텀 심부의 온도분포 가시화)

  • Cho, Ji-Yong;Kim, Jung-Kyung
    • Journal of the Korean Society of Visualization
    • /
    • v.8 no.4
    • /
    • pp.54-59
    • /
    • 2010
  • A laser moxibustion therapy device having effect similar to that of traditional moxibustion is being developed using 1064 nm infrared laser. The therapy device allows direct interaction of laser light with the tissue rendering temperature distribution both on the skin surface and deep under the skin. We made a device that could measure temperature of deep under the surface of agar gel tissue phantom using thermocouples. A thermal imaging camera was used to verify results from the temperature measurement device. We compared the characteristics of heat transfer inside the tissue phantom during moxibustion and laser irradiation. The temperature distribution measured by thermocouples was found to be similar to that of distribution given by thermal imaging camera.

Development of 1064 nm squeezer for quantum non-demolition measurement in gravitational wave detector

  • Park, June Gyu;Kim, Chang-Hee;Lee, Sungho;Kim, Yunjong;Seong, Hyeon Cheol;Jeong, Ueejeong;Je, Soonkyu
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.46 no.2
    • /
    • pp.60.3-60.3
    • /
    • 2021
  • Squeezed vacuum injection을 이용한 중력파 검출기의 관측감도 향상 기술은 중력파 검출기 광신호의 양자 잡음을 제어하여 관측감도를 높이는 기술로 이론적으로는 10dB에 가까운 신호 대 잡음비 향상을 달성할 수 있다. 실험실 환경에서는 이미 10dB 이상의 신호 대 잡음비 향상을 달성했으며 실제 중력파 검출기에서는 GEO600의 6dB의 신호 대 잡음비 향상이 현재까지 가장 높은 수준이다. 한국천문연구원에서는 2019년부터 차세대 중력파 검출기 기술개발로 1064 nm 파장의 squeezer 개발을 추진했으며 현재 parametric down conversion을 이용해 squeezed vacuum을 생성하는 공진기를 제작하여 시험하는 단계에 있다. 이 발표에서는 한국천문연구원의 1064 nm squeezer 개발 연구와 개발 현황에 대해 소개하고자 한다.

  • PDF