• Title/Summary/Keyword: 100미터

Search Result 333, Processing Time 0.022 seconds

Properties on the Strength of Polymer Concrete Using Nano MMT-UP Composite (나노 MMT-폴리머 복합체를 이용한 폴리머 콘크리트의 강도 특성)

  • Jo, Byung-Wan;Moon, Rin-Gon;Park, Seung-Kook
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.4A
    • /
    • pp.761-766
    • /
    • 2006
  • Polymer composite are increasingly considered as structural components for use in civil engineering, on account of their enhanced strength-to-weight ratios. Unsaturated polyester (UP) resin have been widely used for the matrix of composites such as FRP and polymer composite, due to its excellent adhesive. Polymer nanocomposites are new class of composites derived from the nano scale inorganic particles with dimensions typically in the range of 1 to 1000 nm that are dispersed in the polymer matrix homogeneously. Owing to the high aspect ratio of the fillers, mechanical, thermal, flame, retardant and barrier properties are enhanced without significant loss of clarity, toughness or impact strength. To prepare the MMT (Montmorillonite)-UP exfoliated nanocomposites, UP was mixed with MMT at $60^{\circ}C$ for 3 hours by using pan mixer. XRD (X-ray diffraction) pattern of the composites and TEM (Transmission Electron Micrographs) showed that the interlayer spacing of the modified MMT were exfoliated in polymer matrix. The mechanical properties also supported these findings, since in general, tensile strength, modulus with modified MMT were higher than those of the composites with unmodified MMT. The thermal stability of MMT-UP nanocomposite is better than that of pure UP, and its glass transition temperature is higher than that of pure UP. The polymer concrete made with MMT-UP nanocomposite has better mechanical properties than of pure UP. Therefore, it is suggested that strength and elastic modulus of polymer concrete was found to be positively tensile strength and tensile modulus of the MMT-UP nanocomposites.

Studies for B-type Natriuretic Peptide Values and Its Association with Diastolic Echocardiographic Parameters (B-type Natriuretic Peptide 수치와 이완기 심초음파 파라미터와의 연관성 연구)

  • Bae, Seong-Jo;Kwon, Kisang;Lee, Eun Ryeong
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.48 no.4
    • /
    • pp.394-400
    • /
    • 2016
  • The b-type natriuretic peptide (BNP) values and increase on functional disorder in the ventricle, and are used as an index to diagnose heart failure and predict the prognosis. BNP values is known to be relevant to dyssystole in congestive heart failure. This study aimed to identify correlation between the BNP values and the items that indicate the diastolic function in echocardiography. The research divided 188 patients who went through the BNP test and echocardiography in the hospital into the groups with the BNP values; <100, 100-300, 301-600, 601-900, and >901 pg/mL. As the BNP values increase, there was relevance with the echocardiography items of ejection fraction, size of left atrium, E velocity, A velocity, Deceleration time, E/A ratio, E', A', S' and E/E'. In comparison on the groups divided based on the BNP values, E/E' had the highest relevance. The research also categorized 67 patients who diagnosed with heart failure. In comparison on the groups of the heart failure patients, the BNP values of the three groups of Grade I: $623.0{\pm}459.7pg/mL$, Grade II: $1013.2{\pm}1155.1pg/mL$ and Grade III: $1693.4{\pm}1544.0pg/mL$, respectively (p<0.01). As the grade was higher, there was a higher relevance with the echocardiography items of ejection fraction, size of left atrium, E velocity, A velocity, Deceleration time, E/A ratio, E', A', S' and E/E' (p<0.001). Higher BNP values had a higher relevance with the items that indicate the diastolic function in echocardiography and the BNP values of the Restrictive physiology group were the highest in echocardiography. So the BNP values was thought to be valuable to predict diastolic function of heart.

Speech Recognition Using Linear Discriminant Analysis and Common Vector Extraction (선형 판별분석과 공통벡터 추출방법을 이용한 음성인식)

  • 남명우;노승용
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.4
    • /
    • pp.35-41
    • /
    • 2001
  • This paper describes Linear Discriminant Analysis and common vector extraction for speech recognition. Voice signal contains psychological and physiological properties of the speaker as well as dialect differences, acoustical environment effects, and phase differences. For these reasons, the same word spelled out by different speakers can be very different heard. This property of speech signal make it very difficult to extract common properties in the same speech class (word or phoneme). Linear algebra method like BT (Karhunen-Loeve Transformation) is generally used for common properties extraction In the speech signals, but common vector extraction which is suggested by M. Bilginer et at. is used in this paper. The method of M. Bilginer et al. extracts the optimized common vector from the speech signals used for training. And it has 100% recognition accuracy in the trained data which is used for common vector extraction. In spite of these characteristics, the method has some drawback-we cannot use numbers of speech signal for training and the discriminant information among common vectors is not defined. This paper suggests advanced method which can reduce error rate by maximizing the discriminant information among common vectors. And novel method to normalize the size of common vector also added. The result shows improved performance of algorithm and better recognition accuracy of 2% than conventional method.

  • PDF

Switching and Leakage-Power Suppressed SRAM for Leakage-Dominant Deep-Submicron CMOS Technologies (초미세 CMOS 공정에서의 스위칭 및 누설전력 억제 SRAM 설계)

  • Choi Hoon-Dae;Min Kyeong-Sik
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.3 s.345
    • /
    • pp.21-32
    • /
    • 2006
  • A new SRAM circuit with row-by-row activation and low-swing write schemes is proposed to reduce switching power of active cells as well as leakage one of sleep cells in this paper. By driving source line of sleep cells by $V_{SSH}$ which is higher than $V_{SS}$, the leakage current can be reduced to 1/100 due to the cooperation of the reverse body-bias. Drain Induced Barrier Lowering (DIBL), and negative $V_{GS}$ effects. Moreover, the bit line leakage which may introduce a fault during the read operation can be eliminated in this new SRAM. Swing voltage on highly capacitive bit lines is reduced to $V_{DD}-to-V_{SSH}$ from the conventional $V_{DD}-to-V_{SS}$ during the write operation, greatly saving the bit line switching power. Combining the row-by-row activation scheme with the low-swing write does not require the additional area penalty. By the SPICE simulation with the Berkeley Predictive Technology Modes, 93% of leakage power and 43% of switching one are estimated to be saved in future leakage-dominant 70-un process. A test chip has been fabricated using $0.35-{\mu}m$ CMOS process to verify the effectiveness and feasibility of the new SRAM, where the switching power is measured to be 30% less than the conventional SRAM when the I/O bit width is only 8. The stored data is confirmed to be retained without loss until the retention voltage is reduced to 1.1V which is mainly due to the metal shield. The switching power will be expected to be more significant with increasing the I/O bit width.

The Direction and Level of Dominant Eye According to the Tests (검사방법에 따른 우세안의 방향 및 강도의 비교)

  • Shim, Jun-Beom;Joo, Seok-Hee;Shim, Hyun-Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.3
    • /
    • pp.363-368
    • /
    • 2015
  • Purpose: In this study, dominant eye is monitoring and level of dominant was measured in subjective and objective test. Methods: The average age of 21.08 years old of 129 adult (69 male, 60 female) who was no underlying ocular disease were participated in this study. dominant eye was determined by monocular instrument in subjecttive test and using a thin ring ($3.8cm{\times}3.8cm$) in objective test and level of dominant was measured direction of movement of the thin rim. Results: In the subjective test, there are 100 (77.52%) subjects whose dominant eye was right eye, and 29 (22.48%) subjects whose dominant eye was left eye. In the objective test, 90 (69.77%) subjects had right eye d and 33 (25.58%) subjects had left eye, as dominant eye, and 6 (4.65%) subjects had no dominant eye. Comparison of subjective test and objective test by dominant eye were equal in the 104 (80.62%) subjects, unequal in the 19 (14.73%) and center 6 (4.65%) subjects. The level of dominant eye in objective dominant eye test, there were middle 52 (57.78%) subjects, high 38 (42.22%) subjects in the right eye, and middle 25 (75.76%) subjects, high 8 (24.24%) subjects in the left eye. Conclusions: In this study O - Ring Test hasadvantage of direction and level of dominant eye, and middle or center dominant eye was shown in unequal. From this results, testing of dominant eye should be relationship equal and unequal, also required to be study in dominant eye level in binocular vision.

In Vitro Stability of Liposomes Containing Newly Synthesized Glycolipid (신규 합성 당지질 함유 리포솜의 In Vitro 안정성)

  • Song, Chung-Kil;Jung, Soon-Hwa;Seong, Ha-Soo;Cho, Sun-Hang;Shin, Byung-Cheol
    • Journal of the Korean Chemical Society
    • /
    • v.51 no.1
    • /
    • pp.43-50
    • /
    • 2007
  • Liposomes having particle size from several tens to hundreds nanometers are efficient carriers for injectable drug delivery. Enhancement of liposome stability in bloodstream has been studied because of its relatively short circulation time and fast clearance from human body by reticuloendothelial system (RES) in blood vessel. In this study, new disaccharide-1,2-distearoyl-sn-glycero-3-phosphoethanolamine (DSPE) derivatives in which lactose or sucrose as the disaccharide molecule was conjugated covalently to DSPE were synthesized. Liposomes of which surface had disaccharide molecules were prepared by incorporating the disaccharide-DSPE into liposomes as one of their lipid components. Particle size of the prepared liposomes was approximately 100 nm. The liposomes of which surface were modified with the disaccharide-DSPE showed -25 mV of zeta potential value due to the presence of hydroxyl groups on their surface, while the unmodified control liposomes showed -10 mV of zeta potential value. Loading efficiency of model drug, doxorubicin, into liposomes was about 90%. Stability of the disaccharide-modified liposomes in vitro was evaluated by monitoring the amount of protein adsorption and particle size of the liposomes in serum. Disaccharide-modified liposomes were more stable in serum than unmodified control liposomes or polyethyleneglycol (PEG)-modified liposomes due to less adsorption of serum protein and hence less increase of their particle size. The liposomes of which surface was modified with disaccharide-DSPE conjugate can be used as long-circulating carriers for drugs having high toxicity or short half-life time due to their enhanced stability in blood circulatory system.

Low-Power CMOS On-Chip Voltage Reference Circuits (저전력 CMOS On-Chip 기준전압 발생회로)

  • Kwon, Duck-Ki;Park, Jong-Tae;Yu, Chong-Gun
    • Journal of IKEEE
    • /
    • v.4 no.2 s.7
    • /
    • pp.181-191
    • /
    • 2000
  • In this paper, two schemes of generating reference voltages using enhancement-mode MOS transistors and resistors are proposed. The first one is a voltage-mode scheme where the temperature compensation is made by summing a voltage component proportional to a threshold voltage and a voltage component proportional to a thermal voltage. In the second one, that is a current-mode scheme, the temperature compensation is made by summing a current component proportional to a threshold voltage and a current component proportional to a thermal voltage. The designed circuits have been simulated using a $0.65{\mu}m$ n-well CMOS process parameters. The voltage-mode circuit has a temperature coefficient less than $48.0ppm/^{\circ}C$ and a power-supply(VDD) coefficient less than 0.21%/V for a temperature range of $-30^{\circ}C{\sim}130^{\circ}C$ and a VDD range of $3V{\sim}12V$. The current-mode circuit has a temperature coefficient less than $38.2ppm/^{\circ}C$ and a VDD coefficient less than 0.8%/V for $-30^{\circ}C{\sim}130^{\circ}C\;and\; 4V{\sim}12V$. The power consumption of the voltage-mode and current-mode circuits are $27{\mu}W\;and\;65{\mu}W$ respectively for 5V and $30^{\circ}C$. Measurement results show that the voltage-mode reference circuit has a VDD coefficient less than 0.63%/V for $30^{\circ}C{\sim}100^{\circ}C$ and has a temperature coefficient less than $490ppm/^{\circ}C\;for\;3V{\sim}6V$. The proposed reference circuits are simple and thus easy to design. The proposed current-mode reference circuit can be designed to generate a wide range of reference voltages.

  • PDF

Comparison of Retinal Ganglion Cell Responses to Different Voltage Stimulation Parameters in Normal and rd1 Mouse Retina (정상망막과 변성망막에서 전압자극 파라미터 변화에 따른 망막신경절세포의 반응 비교)

  • Ye, Jang-Hee;Ryu, Sang-Baek;Kim, Kyung-Hwan;Goo, Yong-Sook
    • Progress in Medical Physics
    • /
    • v.21 no.2
    • /
    • pp.209-217
    • /
    • 2010
  • Retinal prostheses are being developed to restore vision for the blind with retinal diseases such as retinitis pigmentosa (RP) or age-related macular degeneration (AMD). Since retinal prostheses depend upon electrical stimulation to control neural activity, optimal stimulation parameters for successful encoding of visual information are one of the most important requirements to enable visual perception. Therefore, in this paper, we focused on retinal ganglion cell (RGC) responses to different voltage stimulation parameters and compared threshold charge densities in normal and rd1 mice. For this purpose, we used in vitro preparation for the retina of normal and rd1 mice on micro-electrode arrays. When the neural network of rd1 mouse retinas is stimulated with voltage-controlled pulses, RGCs in degenerated retina also respond to voltage amplitude or voltage duration modulation as well in wild-type RGCs. But the temporal pattern of RGCs response is very different; in wild-type RGCs, single peak within 100 ms appears while in RGCs in degenerated retina multiple peaks (~4 peaks) with ~10 Hz rhythm within 400 ms appear. The thresholds for electrical activation of RGCs are overall more elevated in rd1 mouse retinas compared to wild-type mouse retinas: The thresholds for activation of RGCs in rd1 mouse retinas were on average two times higher ($70.50{\sim}99.87\;{\mu}C/cm^2$ vs. $37.23{\sim}61.65\;{\mu}C/cm^2$) in the experiment of voltage amplitude modulation and five times higher ($120.5{\sim}170.6\;{\mu}C/cm^2$ vs. $22.69{\sim}37.57\;{\mu}C/cm^2$) in the experiment of voltage duration modulation than those in wild-type mouse retinas. This is compatible with the findings from human studies that the currents required for evoking visual percepts in RP patients is much higher than those needed in healthy individuals. These results will be used as a guideline for optimal stimulation parameters for upcoming Korean-type retinal prosthesis.

A new diagnostic method for diabetic neuropathy using $TcpO_2$ ($TcpO_2$ 이용한 당뇨병성 신경병증 환자의 조기진단)

  • Hong, Hyun-Ki;Kim, Sung-Woo;Nam, Ki-Chang;Cha, Eun-Jong;Kim, Deok-Won
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.3
    • /
    • pp.1-8
    • /
    • 2007
  • PDiabetic neuropathy is one of the most common diabetes related complications including diabetic nephropathy and retinopahty. In clinical practices, nerve conduction velocity (NCV) has been used as a standard method for diagnosing diabetic neuropathy. However, it applies maximum current of 100mA to nerves causing stress and pain to patients. In this study, as a non-invasive method, $TcpO_2$ was utilized to investigate the difference and relationship between $TcpO_2$ and $SpO_2$ of normal and diabetic neuropathy subjects. In addition, a new method of diagnosing diabetic neuropathy using $TcpO_2$ is suggested. 50 normal subjects and 50 diabetic patients with neuropathy diagnosed by NCV participated in this study. Parameters used in this study were $TcpO_2$, $TcpCO_2$, and $SpO_2$. As a result of the $TcpO_2$ measurements, statistical significances were found from $TcpO_2$ of hands and feet from normal and patients group(p<0.01). $SpO_2$ measured from index finger of normal and patient groups showed no statistical significance(p>0.05). On the other hand, $SpO_2$ measured from great toes of normal and patient groups showed statistical significance(p<0.01). Correlation coefficient between $SpO_2$ of finger and $TcpO_2$ of hand was 0.400 (p<0.01) and $SpO_2$ of toe and $TcpO_2$ of foot was 0.471(p<0.01). Both correlation values were statistically significant. Sensitivities and specificities of the $TcpO_2$ method were found to be 66 % and 92 %, respectively. If the suggested $TcpO_2$ method is used periodically, prevention and early diagnosis of diabetic neuropathy would be possible.

Effect of the Configuration of Contact Type Textile Electrode on the Performance of Heart Activity Signal Acquisition for Smart Healthcare (스마트 헬스케어를 위한 심장활동 신호 검출용 접촉식 직물전극의 구조가 센싱 성능에 미치는 영향)

  • Cho, Hyun-Seung;Koo, Hye-Ran;Yang, Jin-Hee;Lee, Kang-Hwi;Kim, Sang-Min;Lee, Jeong-Hwan;Kwak, Hwy-Kuen;Ko, Yun-Su;Oh, Yun-Jung;Park, Su-Youn;Kim, Sin-Hye;Lee, Joo-Hyeon
    • Science of Emotion and Sensibility
    • /
    • v.21 no.4
    • /
    • pp.63-76
    • /
    • 2018
  • The purpose of this study was to investigate the effect of contact type textile electrode structure on heart activity signal acquisition for smart healthcare. In this study, we devised six contact type textile electrodes whose electrode size and configuration were manipulated for measuring heart activity signals using computerized embroidery. We detected heart activity signals using a modified lead II and by attaching each textile electrode to the chest band in four healthy male subjects in a standing static posture. We measured the signals four times repeatedly for all types of electrodes. The heart activity signals were sampled at 1 kHz using a BIOPAC ECG100, and the detected original signals were filtered through a band-pass filter. To compare the performance of heart activity signal acquisition among the different structures of the textile electrodes, we conducted a qualitative analysis using signal waveform and size as parameters. In addition, we performed a quantitative analysis by calculating signal power ratio (SPR) of the heart activity signals obtained through each electrode. We analyzed differences in the performance of heart activity signal acquisition of the six electrodes by performing difference and post-hoc tests using nonparametric statistic methods on the calculated SPR. The results showed a significant difference both in terms of qualitative and quantitative aspects of heart activity signals among the tested contact type textile electrodes. Regarding the configurations of the contact type textile electrodes, the three-dimensionally inflated electrode (3DIE) was found to obtain better quality signals than the flat electrode. However, regarding the electrode size, no significant difference was found in performance of heart signal acquisition for the three electrode sizes. These results suggest that the configuration method (flat/3DIE), which is one of the two requirements of a contact type textile electrode structure for heart activity signal acquisition, has a critical effect on the performance of heart activity signal acquisition for wearable healthcare. Based on the results of this study, we plan to develop a smart clothing technology that can monitor high-quality heart activity without time and space constraints by implementing a clothing platform integrated with the textile electrode and developing a performance improvement plan.