Analysis of Power Supply System for 8.5 MVA Magnetic Power Supply Using EI (EMTDC를 이용한 8.5 MVA급 Magnetic Power Supply의 전력공급 시스템 분석)

  • Jeong, Yong-Hoo;Nho, Eui-Cheol;Kim, In-Dong;Choi, Jung-Wan
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1114-1116
    • /
    • 2002
  • The characteristics of voltage drop and THD for parallel operating 11 PCRs (Phase Controlled Rectifiers) are analysed. The PCRs are used to drive high current (1.6 kA ${\sim}$ 3.7 kADC) electromagnetic coils for electromagnets. All the PCRs operate simultaneously in pulsed mode, and the pulse shot occurs every 150 seconds. During the pulse operation the PCR output current ramps up for 4 seconds, and then keeps flat top state for 2 seconds, and finally ramps down for 4 seconds. For the flat top mode a severe voltage drop and distortion appear in the power system because transformers for the PCRs are designed considering pulsed mode operation. It is expected that the analysis method can be applied to improve the system performance including power factor and design of high power pulsed mode operating power supply systems.

  • PDF

Super-PVA (S-PVA) Technology for HDTV Application

  • Kim, Kyeong-Hyeon;Berkeley, Brian;Kim, Sang-Soo;Souk, Jun-Hyung
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.26-29
    • /
    • 2004
  • S-PVA is a new technology which enables screen quality advantages over S-IPS and MVA, including high transmittance, >1000:1 contrast ratio, sub-10ms response time, and wide angle of view with no off-axis image inversion and undetectable gamma distortion. This new technology will be described in detail. This paper also addresses the other remaining performance issues facing LCD-TV, including Samsung's plans for addressing these challenges. For example, until recently, inter-gray response time and associated motion blur were significant issues for achieving LCD-TV images quality. Samsung has invented DCC-II technology to achieve sub-10ms response time, and this achievement is described herein. Other technology advancements, including next-generation color performance and ultra-low black performance and improvement of off axis image quality are also discussed in this paper.

  • PDF

Assessment of Insulation Condition in 13.8 kV Generator Stator Windings (13.8 kV급 발전기 고정자 권선의 절연상태 평가)

  • Kim, Hee-Dong;Kong, Tae-Sik;Ju, Young-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1624-1625
    • /
    • 2011
  • 35년 이상 동안 운전된 2대의 가스터빈 발전기(70 MVA, 13.8 kV) 고정자 권선의 절연상태를 평가하기 위해 정지중 절연진단 시험을 수행하였다. 성극지수, 교류전류, 유전정접 및 부분방전 크기 등을 측정한 결과 모두 양호하여 절연상태가 매우 건전하게 평가되었다. 유전정접이 서서히 증가하는 전압이 부분방전 개시전압과 거의 일치하며, 이 전압은 다시 제1차 전류 급증점 보다는 3 kV정도 낮게 분석되었다. 그리고 발전기 고정자 권선의 부분방전 패턴은 내부방전으로 분석되었다.

  • PDF

A Study on Transient Numerical Simulation on Heat Transfer Characteristics in the Resistive SFCL

  • Kim Chul-Ho;Lee Kee-Man;Ryu Kyung-Woo
    • Progress in Superconductivity and Cryogenics
    • /
    • v.7 no.4
    • /
    • pp.14-19
    • /
    • 2005
  • A transient numerical simulation was conducted to have variation of temperature on an element of resistive Superconducting Fault Current Limiter (SFCL) under quench condition. It is very important engineering information for an optimum design of cryogenic system for cooling of a resistive SFCL element. A bifilar coil for resistive SFCL for 10 MVA system was incorporated as a model in this numerical study. From the numerical simulation result, it was found that the averaged temperature on the shunt and Bi-2212 element at 500 kW, 100 ms was 711.1 K and 198.4 K respectively. The temperature variation with the change of the hot-spot size and time is also obtained. The maximum temperature was continuously increased in all cases until the hot-spot stops at 100ms and it was going down after then. Such as, the details of temperature distribution on the SFCL element obtained from this numerical study and it should be very valuable information on the decision of the cooling capacity of cryogenic system.

A Study on the High Performance PWM Technique for a Propulsion System of Railway

  • Lee, K.J.;Jeong, M.K.;Bang, L.S.;Seo, K.D.;Kim, N.H.
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.425-430
    • /
    • 1998
  • This paper presents a high performance low switching PWM technique for the propulsion system of railway such as subway and high speed train. In order to achieve the continuous voltage control to six-step and a low harmonics with low switching frequency under 500Hz, the synchronous PWM technique is combined with a space vector overmodulation and implemented by using DSP. Improved performance and a validation of proposed method are showed by the digital simulation and the experimental results using a 1.65MVA IGBT VVVF inverter and inertia load equivalent to 160 tons railway vehicles.

  • PDF

Heat Transfer Analysis above L$N_2$ Surface in HTS Transformer (HTS변압기에서 액체질소 표면 상부의 열전달 해석)

  • ;;Steven W. Van Sciver
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.02a
    • /
    • pp.174-177
    • /
    • 2003
  • Cooling load from the top plate to L$N_2$ surface, including wall conduction, gas conduction, radiation, and current leads, is investigated in a closed cooling system for HTS transformer. In general methods of load calculation, individual load is estimated separately, but they are actually coupled each other because of natural convection of nitrogen vapor. Using heat transfer analysis, we calculate cooling load with taking into account the effect of natural convection. Cooling load is under- estimated approximately 2 % when the natural convection is ignored. If the operating current is high, there will be a wide difference between actual cooling load and cooling load by individual calculation. Cooling load decreases with increasing number of radiation shield. With production, construction, and cooling load, three radiation shields are proper to 1 MVA HTS transformer.

  • PDF

Devided operation by each Tank of 765kV Transformer (765kV 변압기 탱크 분리운전)

  • Kim, Moon-Duk;Jung, Si-Hwan;Park, Jong-Myung
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2317-2319
    • /
    • 1999
  • 765kV Transformer, bank capacity is 2,000MVA, is developed of two seperated tanks per phase because transportation weight of the transformer needs to be reduced. So we will operate one tank per phase in some case, low load or black down of 1 tank, using the one phase-two tank type of 765kV transformer to cut down the cost and improve the reliability of substation.

  • PDF

Conceptual Design of an HTS large power transformer with continuously transposed coated conductors

  • Lee, Se-Yeon;Park, Sang-Ho;Kim, Woo-Seok;Lee, Ji-Kwang;Park, Il-Han;Chol, Kyeong-Dal;Hahn, Song-Yop
    • Progress in Superconductivity and Cryogenics
    • /
    • v.13 no.2
    • /
    • pp.5-8
    • /
    • 2011
  • This paper shows results of a design work of a program that is to develop a large power single phase high temperature superconducting (HTS) transformer. The program forms a part of a national project in Korea. A target of the design work is an HTS power transformer with rated voltages of 154 kV/22.9 kV and material for windings is supposed to be coated conductor. The design results presents in this paper will include: 1)HTS winding structures for high voltage in liquid nitrogen, 2)design result of continuously transposed coated conductor (CTCC), 3)conceptual design of high voltage bushings, 4)cooling system. A feasibility study will succeed to this design work for construction of a prototype HTS power transformer with capacity/voltage of 33 MVA/154 kV.

Zero-voltage-switching three level auxiliary resonant commutated pole inverter (영전압 스위칭 3-레벨 보조 공진 폴 인버터)

  • 유동욱;원충연;조정구;백주원
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.4
    • /
    • pp.535-542
    • /
    • 1996
  • A zero voltage switching (ZVS) three level auxiliary resonant commutated pole inverter (ARCPI) is presented for high power GTO inverters. The concept of ARCP for two level inverter is extended to the three inverter. The proposed auxiliary commutation circuit consists of one resonant inductor and two bi-directional switches, which provides ZVS condition to the main devices without increasing device voltage or current stresses. The auxiliary device operates with zero current switching (ZCS) which enables use of the low cost thyristors. The proposed ARCPI can handle higher voltage and higher power (1-10MVA) comparing to the two level one. Operation and analysis of the ARCPI are illustrated and the features are compared o those of the snubber circuit incorporated three level inverter. Experimental results with 10kW, 4kHz prototype are presented to verify the principle of operation. (author). refs., figs., tab.

  • PDF

A Vibration Mode Analysis of the Cable-Type Winding of 22.9kV Power Transfomer by Using A Numerical Method (수치해석을 이용한 22.9kV급 Cable 권선형 변압기의 진동모드 분석)

  • Ha, Jung-Woo;Woo, Sung-Hyun;Shin, Pan-Seok;Lee, Jin-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.91-92
    • /
    • 2007
  • 본 연구에서는 전력계통에서 발생되는 surge나 고장전류에 의해서 변압기의 고압측 코일에 유도되는 전자력의 크기를 유한요소 전자계해석 프로그램(FLUX2D)의 축대칭FEM을 이용하여 해석하였다. 1MVA, 22900/220(V) 단상 외철형 Cable형 변압기의 권선의 각방향의 전자력을 분석하고, 변압기 권선의 고유진동mode를 Transfer Matrix Method를 이용하여 Cable형권선의 고유진동주파수를 파악하고 ANSYS와 비교하였다. 변압기 권선의 전자력과 진동mode 분석결과는 변압기의 절연설계 및 단락기계력에 대한 프레임 구조 설계를 위한 자료로 활용될 수 있다.

  • PDF