• 제목/요약/키워드: 1/4 scale model

검색결과 1,203건 처리시간 0.034초

Comparison of numerical and analytical solutions for reinforced soil wall shaking table tests

  • Zarnani, Saman;El-Emam, Magdi M.;Bathurst, Richard J.
    • Geomechanics and Engineering
    • /
    • 제3권4호
    • /
    • pp.291-321
    • /
    • 2011
  • The paper describes a simple numerical FLAC model that was developed to simulate the dynamic response of two instrumented reduced-scale model reinforced soil walls constructed on a 1-g shaking table. The models were 1 m high by 1.4 m wide by 2.4 m long and were constructed with a uniform size sand backfill, a polymeric geogrid reinforcement material with appropriately scaled stiffness, and a structural full-height rigid panel facing. The wall toe was constructed to simulate a perfectly hinged toe (i.e. toe allowed to rotate only) in one model and an idealized sliding toe (i.e. toe allowed to rotate and slide horizontally) in the other. Physical and numerical models were subjected to the same stepped amplitude sinusoidal base acceleration record. The material properties of the component materials (e.g. backfill and reinforcement) were determined from independent laboratory testing (reinforcement) and by back-fitting results of a numerical FLAC model for direct shear box testing to the corresponding physical test results. A simple elastic-plastic model with Mohr-Coulomb failure criterion for the sand was judged to give satisfactory agreement with measured wall results. The numerical results are also compared to closed-form solutions for reinforcement loads. In most cases predicted and closed-form solutions fall within the accuracy of measured loads based on ${\pm}1$ standard deviation applied to physical measurements. The paper summarizes important lessons learned and implications to the seismic design and performance of geosynthetic reinforced soil walls.

축소 모형을 이용한 지하철터널에서의 연기전파거리 측정 (The Smoke Propagating Distance in the Reduced-scale Model for a Subway Railroad Tunnel)

  • 김명배;최병일;오창보;한용식
    • 한국터널지하공간학회 논문집
    • /
    • 제7권4호
    • /
    • pp.295-304
    • /
    • 2005
  • 지하철의 터널구간에서 화재가 발생하였을 때의 연기전파거리를 측정하였다. 대상은 길이 800m, 단면 $8{\times}5.5m$의 전형적인 지하철 터널로 3개의 급배기 겸용 샤프트가 설치되어 있으며 실험은 1/50의 축소모형을 이용하였다. 연기전파거리 측정을 위하여 열전대와 가시화 기법을 동시에 사용하여 정확도를 확보하였다. 급배기량과 화재크기가 연기전파거리에 미치는 영향을 파악하기 위하여 9개의 조건을 대상으로 실험하였다. 실험결과 분석을 통하여 지하철터널의 배연 설계에 있어서 연기전파거리가 주요 설계요소가 될 수 있음을 밝혔다.

  • PDF

간호대학생의 의사소통 태도 측정도구 타당도 및 신뢰도 검증 (The Validity and Reliability of Communication Skills Attitude Scale (CSAS) for Nursing Students)

  • 송미옥;윤소영
    • 한국산학기술학회논문지
    • /
    • 제18권3호
    • /
    • pp.345-355
    • /
    • 2017
  • 본 연구는 국내 간호대학생을 대상으로 Communication Skills Attitudes Scale (CSAS)의 타당도와 신뢰도를 검증하기 위해 시행되었다. 2016년 6월 1일부터 15일 사이에 일 지역 2개 간호대학의 1학년부터 4학년에 재학 중인 간호대학생 401명을 대상으로 26개 문항으로 이루어진 CSAS 설문지를 작성하도록 하였다. 자료분석은 IBM Statistics SPSS 21.0, IBM Statistics AMOS 21.0 프로그램을 활용하여 탐색적 요인분석, 확인적 요인분석, 내적 일관성을 분석하였다. 도구의 구성요인을 파악하기 위해 베리멕스 회전을 이용한 탐색적 요인분석을 시행하였으며 그 결과 4개 요인이 추출되었지만 이론의 구조 및 해석가능성을 고려하여 긍정태도, 부정태도 2개 요인으로 범주화한 19문항을 확정하였다. 도구의 내적 구조를 도식화하기 위해 확인적 요인분석을 시행하였으며 최종 모델의 적합도는 ${\chi}^2=446.475$(df=148, p<0.001), TLI=.90, CFI=.91, RMSEA=.07, SRMR=.05로 매우 적합하였다. 확인적 요인분석 결과를 토대로 19개 문항 2개 요인으로 이루어진 최종 도구를 확정하였다. 최종 도구의 $Cronbach^{\prime}{\alpha}=.90$으로 나타나 내적일관성을 확인하였다. 본 연구에서 검증된 의사소통 태도 측정도구는 간호대학생의 의사소통에 대한 다양한 교수전략의 효과를 모니터링 하는데 도움을 줄 수 있을 것으로 기대한다.

연소실에서 1/4파장 공명기의 주파수 동조에 대한 수치적 연구 (A Numerical Study on Acoustic Tuning of Quarter-Wave Resonators in a Model Combustion Chamber)

  • 박주현;박이선;손채훈
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.281-284
    • /
    • 2009
  • 로켓엔진 연소기의 연소 불안정 억제를 위해 연소 상황에서의 1/4파장 공명기의 주파수 동조를 수치적으로 연구하였다. 상온 음향 시험을 통해 도출된 최적 감쇠 조건을 충족시키는 사양의 1/4파장 공명기를 채택하였다. 먼저, 실규모 연소실의 조건을 모사한 모형 연소실에서의 연소장을 수치해석하여 기본 음향파 응답 특성을 분석하였다. 다음으로, 이 연소실에 음향 공명기를 장착하여 공명기 내부 물성치를 예측하였다. 이러한 기본 데이터를 토대로 특정 음향 모드를 감쇠시킬 수 있는 주파수 동조 방안을 연구하였다. 각 공명기 내부의 물성치를 토대로 공명기를 개별 공명기의 최적 동조 길이로 설계할 경우에 충분한 감쇠 성능을 얻을 수 있었다. 설계의 편의를 위해 모든 공명기를 동일길이로 설정한 경우, 길이에 따른 감쇠성능을 비교하여 제시하였다. 이를 토대로 최적의 동조길이를 찾을 수 있었다.

  • PDF

3-D Optical Earth System Model Construction and Disk Averaged Spectral Simulation for Habitable Earth-like Exoplanet

  • 류동옥;김석환
    • 천문학회보
    • /
    • 제36권1호
    • /
    • pp.27.2-27.2
    • /
    • 2011
  • The Kepler(NASA) and CoRoT(ESA) space telescopes are surveying thousands of exoplanet for finding Earth-like exoplanets with similar environments of the Earth. Then the TPF(NASA), DARWIN(ESA) and many large-aperture ground telescopes have plan for spectroscopic observations of these earth-like exoplanets in next decades. Now, it has been started to simulate the disk averaged spectra of the earthlike exoplanets for comparing the observed spectra and suggesting solutions of environment of these planets. Previous research, the simulations are based on radiative transfer method, but these are limited by optical models of Earth system and instruments. We introduce a new simulation method, IRT(Integrated Ray Tracing) to overcome limitations of previous method. The 3 components are defined in IRT; 1)Sun model, 2)Earth system model (Atmosphere, Land and Ocean), 3)Instrument model. The ray tracing in IRT is simulated in composed 3D real scale space from inside the sun model to the detector of instrument. The Sun model has hemisphere structure with Lambertian scattering optical model. Atmosphere is composed of 16 distributed structures and each optical model includes BSDF with using 6SV radiative transfer code. Coastline and 5 kinds of vegetation distribution data are used to land model structure, and its non-Lambertian scattering optical model is defined with the semi-empirical "parametric kernel method" used for MODIS(NASA) and POLDER(CNES) missions. The ocean model includes sea ice cap structure with the monthly sea ice area variation, and sea water optical model which is considering non-lambertian sun-glint scattering. Computation of spectral imaging and radiative transfer performance of Earth system model is tested with hypothetical space instrument in IRT model. Then we calculated the disk averaged spectra of the Earth system model in IRT computation model for 8 cases; 4 viewing orientation cases with full illuminated phase, and 4 illuminated phase cases in a viewing orientation. Finally the DAS results are compared with previous researching results of radiative transfer method.

  • PDF

Decomposition and Super-efficiency in the Korean Life Insurance Industry Employing DEA

  • Lee, Hyung-Suk;Kim, Ki-Seog
    • International Journal of Contents
    • /
    • 제4권3호
    • /
    • pp.1-9
    • /
    • 2008
  • The Korean life insurance industry has undergone profound changes, such as the beginning of the variable insurance in July 2001 and the bancassurance enforcement in August 2003. However, little empirical research has analyzed data that includes the bancassurance of life insurance companies operating in Korea. In response to this lack of research, this paper applies DEA (data envelopment analysis) models to measure and decompose their efficiency. We discovered that life insurance companies operating in Korea are a little different in their composition ratio of inputs and outputs, due to the increased variety of distribution channels and new products. We provided efficiency scores, return to scale, and reference frequencies. We also decomposed CCR, BCC, and SBM efficiency into scale efficiency and MIX efficiency. So, we try to investigate whether the sources of inefficiency were caused by the inefficient operation of DMU, disadvantageous conditions, the difference of the composition ratio in inputs and outputs with reference sets, or any combination of the above. Most companies in the sample display had either constant or decreasing returns to scale. The efficiency rankings were less consistent among models and efficient DMUs. In response to this problem, we used the super-efficiency model to rank them and then compared the rankings of the DMUs among the various models. It was also concluded that the availability of panel data, rather than cross-sectional data, would greatly improve the validity of the efficiency estimates.

원발성 월경곤란증과 맥의 관련성 연구 (A Study on the Relationship between Primary Dysmenorrhea and Pulse Energy Measured by 3D Blood Pressure Pulse Analyzer)

  • 이지연;윤영진
    • 대한한방부인과학회지
    • /
    • 제28권4호
    • /
    • pp.31-45
    • /
    • 2015
  • Objectives : The purpose of this study is to examine the relationship between the symptoms of primary dysmenorrhea and pulse energy of Chon, Gwan and Cheok. Methods The subjects of this study who had certain range of dysmenorrhea symptom. The degree of dysmenorrhea were assessed by Visual Analog Scale (VAS), Multidimensional Verbal Rating Scale (MVRS), Cox Menstrual Symptom Scale (CMSS) and measured by 3D Blood Pressure Pulse Analyzer(3D-MAC) tests at menstruation start date. Data analysis included descriptive statistics and multiple linear regression using the SPSS/WIN 18.0 program. Results : The induced results are as follows;The induced results are as follows 1. There were no significant relationship between the pulse energy and the sum values of VAS, MVRS and checking part of severity of CMSS. 2. The frequency domain of CMSS were significantly associated with pulse energy. 3. In linear regression models, the model of Left Chon had the especially highest value of explanatory power. (R 2 = 0.517) Conclusions : The pulse energy changes are related to the symptoms of primary dysmenorrhea.

해상풍력 일괄설치시스템 예인 안정성 및 내항성능 평가를 위한 모형시험 (Model Test for Towing Stability and Seakeeping of a Multi-Purpose Mobile Base)

  • 조동호;이준신;유무성;정민욱;이호엽;한관우;김승한
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제6권2호
    • /
    • pp.163-171
    • /
    • 2020
  • 전력연구원에서 설계한 5 MW급 일괄설치시스템의 예인안정성 및 내항성능 검증을 위해 수조모형시험을 실시하였다. 1/48 축소모형을 만들어 정수 및 파랑 중 시험을 수행하였다. 실선기준 4, 5, 6 knots의 대응속도로 예인하며 예인선의 장력을 계측하고, 실선의 필요 예인 동력을 추정하였다. 또한, 관성계측장치를 이용하여 모형의 6자유도 운동을 계측하였으며, 파랑 중 구속모형시험을 통해 내항성능을 확인하였다.

The Characteristics of a Pump at Nearly Saturated State

  • Kim, S. N.;Kim, J. C.
    • Nuclear Engineering and Technology
    • /
    • 제30권1호
    • /
    • pp.40-46
    • /
    • 1998
  • A set of experiments using a 1/10 scale model pump which was manufactured to simulate performance of reactor coolant pump(RCP) of Y.G.N # 3 and 4, was executed in single phase(at atmospheric pressure and room temperature) and near-saturation(300 ~ 600kPa). The pump characteristics in single phase flow was similar to the characteristics of the RCP. The pump characteristic curves at nearly saturated state were correlated in terms of flow coefficient and head coefficient for subcooled temperature using the cavitation number defined as (equation omitted), which can be predicted the cavitation possibility. The pump behavior around the saturated temperature almost consists with single phase behavior until the cavitation occurs(When cavitation occurs. When the flow coefficient is about 0.12), the pump head rapidly degrades. In this situation, subcooled temperature is about 1.8~8$^{\circ}C$ and cavitation number of model pump is 1.0 ~ 1.7.

  • PDF

방파제를 고려한 초대형 부유식 해상구조물의 유탄성 응답 특성에 관한 실험적 연구 (Experimental Study of Hydroelastic Behaviors of VLFS Considering Breakwaters)

  • 신현경;이형락;유경훈;윤명철;강점문;김화수
    • 대한조선학회논문집
    • /
    • 제41권1호
    • /
    • pp.31-39
    • /
    • 2004
  • In this paper, an experimental study on the hydroelastic behaviors of a VLFS with L=5,000m was made considering a breakwater. The principal dimensions of the VLFS model were 9m${\times}$1.8${\times}$0.0108m(L${\times}$B${\times}$D) and the length of breakwater was 12.6m (1.4L). The distance between the VLFS and the breakwater varied from B/2 to 28. The wide tank test results were compared with the numerical predictions and the comparison showed a little gap along its longitudinal axis, in spite of using the very small model size due to the scale 1/555.5