• Title/Summary/Keyword: 1/3-Octave Band

Search Result 66, Processing Time 0.022 seconds

Investigation into influence of sound absorption block on interior noise of high speed train in tunnel (터널 내부 도상 블록형 흡음재의 고속철도차량 내부 소음에 미치는 영향에 대한 고찰)

  • Lee, Sang-heon;Cheong, Cheolung;Lee, Song-June;Kim, Jae-Hwan;Son, Dong-Gi;Sim, Gyu-Cheol
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.4
    • /
    • pp.223-231
    • /
    • 2018
  • Recently, due to various environmental problems, blast tracks in tunnel are replaced with concrete tracks, but they have more adverse effects on noise than blast tracks so that additional noise measures are needed. Among these measures, sound-absorbing blocks start to be used due to its easy and quick installation. However, the performance of sound absorption blocks need to be verified under real environmental and operational conditions. In this paper, interior noise levels in KTX train cruising in Dalseong tunnel are measured before and after the installation of sound-absorbing blocks and the measured data are analyzed and compared. Additionally, noise reduction are estimated by modeling the high speed train, the tunnel and absorption blocks. Measurement devices and methods are used according to ISO 3381 and the equivalent sound pressure levels during the cruising time inside the tunnel are computed. In addition to overall SPLs(Sound Pressure Levels), 1/3-octave-band levels are also analyzed to account for the frequency characteristics of sound absorption and equipment noise in a cabin. In addition, to consider the effects of train cruising speeds and environmental conditions on the measurements, the measured data are corrected by using those measured during the train-passing through the tunnels located before and behind the Dalseong tunnel. Analysis of measured results showed that the maximum noise reduction of 6.8 dB (A) can be achieved for the local region where the sound-absorbing blocks are installed. Finally, through the comparison of predicted 1/3-octave band SPLs for the KTX interior noise with the measurements, the understanding of noise reduction mechanism due to sound-absorbing blocks is enhanced.

A Study on the Reduction of Floor Impact Sound according to the Thickness and Stiffness of Slab (슬래브 두께 및 강도의 변화에 따른 바닥 충격음 특성에 관한 연구)

  • Park, In-Sun;Kim, Tae-Hee
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.10a
    • /
    • pp.276-277
    • /
    • 2012
  • This study was carried out in the laboratory of the reverberation. A total of six specimens were fabricated depending on the thickness and strength. Floor impact sound insulation performance was measured in 1/3 octave band center frequency. The results of this study are as follows. Although some differences in the frequency band, the result of evaluating the weight impact sound blocking performance as the thickness increases, the floor impact sound insulation performance is improved. In addition, to increase the strength of the slab, even if the block impact sound performance is improved.

  • PDF

A Empirical Review of the Measurement Method for the Impulse Noise Using Ear Simulator (Ear Simulator를 이용한 충격소음 측정방법에 대한 고찰)

  • Song, Kee-Hyeok;Chung, Sung-Hak
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2014.01a
    • /
    • pp.425-426
    • /
    • 2014
  • 충격소음(Impulse Noise) 측정 시 지그(Ear Simulator)가 자체적으로 음압측정에 미치는 영향을 확인하기 위해 지그를 이용하여 실내에서 충격소음을 측정하였다. 측정의 신뢰성과 정확성을 확보하기 위해 마이크로폰과 지그에서 동일조건에서 동시에 데이터를 수집하였다. 추가로 헤드&토르소에서 실험을 실시하였다. 최대음압레벨과 1/3옥타브 밴드 결과를 비교분석함으로써 측정 방법에 따른 차이점을 발견하였다.

  • PDF

Insertion Loss by Noise Barrier on the Discontinuous Ground (불연속 지면위의 방음벽에 의한 삽입손실에 관한 연구)

  • Kim, Ye-Hyun;Kim, Dong-Ill;Jang, Ho-Kyeong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.14 no.3
    • /
    • pp.114-121
    • /
    • 1995
  • Outdoor experimental study is presented the insertion loss caused by barrier considering discontinuous ground condition. Measurements ware made in 1/3 octave band over the frequency range 315 Hz~3150 Hz with the various geometry of the source, receiver and barriers. The frequency range of the interference pattern depends on the phase difference between path from the edge of barrier to receiver, and hence on the acoustical properties of the ground on the receiver side of the barrier. The insertion loss by barrier, in addition to diffraction, is shown to be dependent on the ground characteristic.

  • PDF

A Study on the construction of Broad-Band Twisted-Wire Quadrature Hybrid (광대역 Twisted-Wire Quadrature Hybrid 회로구성에 관한 연구)

  • 박정기;김성진
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.17 no.6
    • /
    • pp.78-85
    • /
    • 1980
  • A symmetrical 3-dB quadrature hybrid circuits, consisting mainly of bifilar pair of taitoted wires, is described. A cascade of two such hybrid circuits can achieve an octave bandwidth hybrid circuit with a small coupling loss. Since the proposed type is simple, compact, and low In cost 1 its applicarion may be preferred to the more common coaxial line or printed -circuit type hybrid version in the frequency region below 1 GHz. This study provides a design method for a hybrid circuit mixing two different antenna signals for the anti - ghosting of television signal.

  • PDF

Korea Industrial Standardization Draft for ISO 354 (ISO 354 (잔향실법 흡음률 측정방법)의 KS 규격화)

  • Jung, Sung-Soo;Kook, Chan;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.857-860
    • /
    • 2003
  • We introduced the basic direction of revision for KS F 2805 (method for measurement of sound absorption coefficient in a reverberation room). It is fundamentally equal to ISO 354 (measurement of sound absorption in a reverberation room) which was state of ISO/FDIS 354. Two main points were strongly reviewed. First, the sound absorption coefficient values for Type J test specimen mounting was investigated. Next, the reverberation time difference between the conventional method and new additional one, impulse response method were compared.

  • PDF

Prediction of Sound Radiation Power from Coupled Structures Uusing SEA (SEA법에 의한 결합구조물의 음향방사파워 예측)

  • 오재응;이명렬
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.1
    • /
    • pp.20-28
    • /
    • 1989
  • SEA(Statistical Energy Analysis) method has been applied to predict the sound radiation power from vibrating machinery. In this study, sound radiation power was predicted from coupled structures by transmission of vibration, which composed of two plates welded into an L shape. The predicted sound radiation power is in agreement within 2 or 3 dB on octave band comparing with values obtained from direct measurements. Also, in order to prove the validity of this method in changes of sound radiation power associated with modifications to structures, rubber pad was stuck on a plate. The results agree approximately within 3 or 5 dB. And SEA method is valuable for the optimal design to reduce the noise. Additionally, this paper suggests that the logarithmic decrement method is valid as the one for finding the loss factor.

An analysis of railway noise from comparison and evaluation between A-weighted SPL and sound quality indices (A-weighted 음압레벨과 음질 지수의 평가 및 비교를 통한 철도소음의 해석)

  • Kim, Dae-Sung;Wang, Se-Myung;Shin, Min-Cheol;Cho, Jun-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1459-1464
    • /
    • 2006
  • In the previous studies on railway noise analysis, the main purpose of noise analysis is concerned with the reduction of A-weighted sound pressure level in order to satisfy noise regulations. However, more important facts on noise reduction are the subjective feelings of the human being on noise because people might be annoyed from the noise caused by train. In this paper, railway noise from different type of train are compared using the calculation of sound quality metrics with using strength related method that is calculation of A-weighted sound pressure level.

  • PDF

Analysis of Vehicle Noise Effect by Microphone Position and Road Geometry (도로 기하구조에 따른 차량 Microphone 위치별 소음 영향 분석)

  • Moon, Hak Ryong;Han, Dae Cheol;Kang, Won Pyoung
    • International Journal of Highway Engineering
    • /
    • v.15 no.4
    • /
    • pp.75-83
    • /
    • 2013
  • PURPOSES: The purpose of study is to understand the characteristic of driving noise from the front and rear tire for effective active noise cancellation application. METHODS : As literature review, noise measurement methods were reviewed. Noise measurement conducted at three kind of section by road slope using CPX(Close Proximity Method). Noise data was compared by total sound pressure level and 1/3 octave band frequency sound pressure level. Also, each section was compared by T-test using SPSS. RESULTS : In the case of the uphill section, it was shown that the sound pressure level of the front tire at Sugwang-Ri and Sinchon-RI sections was higher than that of the rear tire in low and high frequency band. In the case of high slope section of Sangsaek-Ri, the sound pressure level of the front tire was higher than that of the rear tire in high frequency. Also, in the case of the downhill section, it was shown that the sound pressure level of the front tire at Sugwang-Ri and Sinchon-RI sections was higher than that of the rear tire in low frequency band. However, the sound pressure levels of both the front and rear tires were approximately the same in the high slope section of Sangsaek-Ri. The result of T-test showed that total sound pressures of the front and rear tires were not different from each other in the case of high slope and high speed. CONCLUSIONS: Road slope was not an important variable for effective active noise cancellation.

Au Experimental Study on the Aerodynamic Noise by a Circular Jet Impinging on a Plate (평판에 충돌하는 원형분류의 공력소음에 관한 실험적 연구)

  • 이동훈;권영필;한희갑
    • Journal of KSNVE
    • /
    • v.7 no.1
    • /
    • pp.71-79
    • /
    • 1997
  • The objective of this study is to investigate experimentally the effect of surface conditions of the plate on the impinging jet noise. The experimental results about the spectrum, the sound pressure level and the directivity are pressented and discussed in relation with the surface conditions. Regardless of the surface conditions, the pure tones of high level are generated at the same frequency band and the overall sound power level of impinging jets is much higher than that of the free jet. However, the velocity dependence of the sound pressure level and the directivity are different between smooth surfaces and rough surfaces. The dependence of sound pressure level on the jet velocity shows that the smooth surface generates quadrupole-type sound like free jets. However, the perforated or the rough surface radiates sound power exactly proportional to the sixth power of the jet velocity, indicating that the source is fixed dipole type. The directivities of 1/3 octave band sound pressure level for both the free and impinging jet show the peak directivity at 115$^\circ$ upstream, probably due to the refraction associated with velocity gradient.

  • PDF