• Title/Summary/Keyword: 1/1옥타브밴드소음

Search Result 19, Processing Time 0.024 seconds

A Empirical Review of the Measurement Method for the Impulse Noise Using Ear Simulator (Ear Simulator를 이용한 충격소음 측정방법에 대한 고찰)

  • Song, Kee-Hyeok;Chung, Sung-Hak
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2014.01a
    • /
    • pp.425-426
    • /
    • 2014
  • 충격소음(Impulse Noise) 측정 시 지그(Ear Simulator)가 자체적으로 음압측정에 미치는 영향을 확인하기 위해 지그를 이용하여 실내에서 충격소음을 측정하였다. 측정의 신뢰성과 정확성을 확보하기 위해 마이크로폰과 지그에서 동일조건에서 동시에 데이터를 수집하였다. 추가로 헤드&토르소에서 실험을 실시하였다. 최대음압레벨과 1/3옥타브 밴드 결과를 비교분석함으로써 측정 방법에 따른 차이점을 발견하였다.

  • PDF

A Study on the Noise Levels of Cargo-Passenger Iron Ships ply South-West Coast Line (서남 연근해 운항 차도철부선의 선내 소음에 관한 연구)

  • Yu Young-Hun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.12 no.3 s.26
    • /
    • pp.193-199
    • /
    • 2006
  • The noise levels on board ship recognized at Europe in the early 1970s and the noise regulations on the ship began to put in a statutory form. After that, in 1982 'International Code on Noise Levels on Board Ships' adopted by IMO and it became a standards to the newly built ship and it remains up to recently. Especially, the ship engine room, which have huge main engine and various kinds of subsidiary machines, is under an extremely loud condition and so the worker who works in it is easy to lose his hearing. Recently, each nation regulates the allowable noise exposure time by law to protect the industrial employee from the occupational hardness of hearing. In our country, the allowable noise exposure time is regulated by the labor. standard law but the international provisions regulated by IMO have been applied in case of the ship engine room. In this paper, the cabin's noise levels of cargo-passenger ships plies south-west coast line were investigated.

  • PDF

Wind Turbine Noise (풍력발전기 소음평가)

  • Jung, Sung Soo;Jeon, Byung Soo;Seo, Jae Gap;Lee, Yong Bong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.431-434
    • /
    • 2014
  • Wind turbine industry is the most developing field among other renewable energy industry. As expanding wind farms, noise is the big problem to solve. This study is about wind turbine noise measuring method based on IEC 61400-11. Sound pressure levels, 1/3-octave band levels, and low frequency sound pressure levels of a 3 MW wind turbine were measured and analyzed.

  • PDF

A Study on the Cabin's Noise Levels of Cargo-Passenger Ships plies South-West Coast line (서남 연근해 운항 정기화객선의 선내 소음에 관한 연구)

  • Yu, Young-Hun
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2006.05a
    • /
    • pp.207-212
    • /
    • 2006
  • The noise levels on board ship recognized at Europe in the early 1970s and the noise regulations on board ship began to put in a statutory form. After that, in 1982 "International Code on Noise Levels on Board Ships" adopted by IMO and it became standard to the newly built ship and remain so to this day. Especially, the ship engine room, which have huge main engine and various kinds of subsidiary machines, is under an extremely loud condition and so the worker who works in it is easy to lose his hearing. Recently, each nation regulates the allowable noise exposure time by law to protect the industrial employee from the occupational hardness of hearing. In our country, the allowable noise exposure time is regulated by the labor standard law but the international provisions regulated by IMO have been applied in case of the ship engine room. In this paper, the cabin's noise levels of cargo-passenger ships plies south-west coast line were investigated.

  • PDF

An analysis of railway noise from comparison and evaluation between A-weighted SPL and sound quality indices (A-weighted 음압레벨과 음질 지수의 평가 및 비교를 통한 철도소음의 해석)

  • Kim, Dae-Sung;Wang, Se-Myung;Shin, Min-Cheol;Cho, Jun-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1459-1464
    • /
    • 2006
  • In the previous studies on railway noise analysis, the main purpose of noise analysis is concerned with the reduction of A-weighted sound pressure level in order to satisfy noise regulations. However, more important facts on noise reduction are the subjective feelings of the human being on noise because people might be annoyed from the noise caused by train. In this paper, railway noise from different type of train are compared using the calculation of sound quality metrics with using strength related method that is calculation of A-weighted sound pressure level.

  • PDF

Real-Time 1/3-Octave Band Spectrum Control System of High Intensity Acoustic Chamber (음향 첨버 내부의 1/3-옥타브밴드 스펙트럼 실시간 제어 시스템)

  • Kim, Youngkey K.;Kim, Hong-Bae;Moon, Sang-Mu;Woo, Sung-Hyun;Lee, Sang-Seol
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.386.2-386
    • /
    • 2002
  • This paper reports the performance and the Algorithm of an 1/3-octave band spectrum control system. The system is developed to provide various required spectrums in a high intensity acoustic chamber. The required spectrums, which usually comes from launch vehicle specification, starts from 25㎐ band and ends 10,000㎐. Short settling time is required to guarantee the safety of test objects and reduce the amount of operating gas. (omitted)

  • PDF

Analysis of Dependence on Wind Speed and Ship Traffic of Underwater Ambient Noise at Shallow Sea Surrounding the Korean Peninsula (한반도 주변해역 수중배경소음의 풍속과 선박분포에 따른 의존성 분석)

  • 최복경;김봉채;김철수;김병남
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.3
    • /
    • pp.233-241
    • /
    • 2003
  • It is statistically analyzed the underwater ambient noise measured at 13 sites less than 200 m deep in the shallow water surrounding the Korean Peninsula for 9 yews from 1990 to 1998 in various environmental conditions. Frequency spectra were obtained with the 1/3-octave band center frequencies from 25㎐ to 20 ㎑. The analyzed shallow water noise spectra were some different from the deep water blown as the Wenz spectra. We could know that the ambient noise level shows higher than it in same condition by effect of various ship activity and the coastal noise, surface waves, and so on. As a result, we produced the coastal ambient noise spectra curve based on these results in shore of the Korea Peninsula.

Korea Industrial Standardization Draft for ISO 354 (ISO 354 (잔향실법 흡음률 측정방법)의 KS 규격화)

  • Jung, Sung-Soo;Kook, Chan;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.857-860
    • /
    • 2003
  • We introduced the basic direction of revision for KS F 2805 (method for measurement of sound absorption coefficient in a reverberation room). It is fundamentally equal to ISO 354 (measurement of sound absorption in a reverberation room) which was state of ISO/FDIS 354. Two main points were strongly reviewed. First, the sound absorption coefficient values for Type J test specimen mounting was investigated. Next, the reverberation time difference between the conventional method and new additional one, impulse response method were compared.

  • PDF

Field Test and Evaluation of Noise from Wind Turbine Generators at Yongdang and Hangwon in Jeju Island (제주도 용당/행원 풍력발전기 현장 소음 실증)

  • Cheong, Cheol-Ung;Jeong, Sung-Su;Cheung, Wan-Sup;Shin, Su-Hyun;Jeon, Se-Jong;Lee, Saeng-Hui
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.818-821
    • /
    • 2005
  • The sound measurement procedures of IEC 61400-11 are applied to field test and evaluation of noise emission from 1.5 MW wind turbine generator (WTG) at Yongdang and 660 kW WTG at Hangwon in Jeju Island. Apparent sound power level, wind speed dependence and third-octave band levels are evaluated for both of WTGs. 1.5 MW WTG at Yongdang is found to emit lower sound power than 660 kW one at Hangwon, which seems to be due to lower rotating speed of the rotor of WTG at Yongdang. Equivalent continuous sound pressure levels (ECSPL) of 660 kW WTG at Hangwon vary more widely with wind speed than those of 1.5 MW WTG at Yongdang. The reason for this is believed to be the fixed blade rotating speed of WTG at Yongdang. One-third octave band analysis of the measured data show that the band components around 400-500 Hz are dominant for 1.5 MW WTG at Yongdang and those around 1K Hz are dominant for 660 kW WTG at Hangwon.

  • PDF

A study on the identification of noise sources of the 4-cylinder gasoline engine by using acoustic intensity method (음향인텐시티법을 이용한 4기통 가솔린 엔진의 소음원 검출에 관한 연구)

  • Oh, J. E.
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.11 no.1
    • /
    • pp.57-67
    • /
    • 1989
  • Acoustic intensity method is applied to a 4-cylinder gasoline engine in order to identify the noise sources and the response characteristics. Acoustic intensity is analyzed by 1/3 octave band filter for each center frequency. Radiational characteristics of acoustic intensity at overall and the maximum intensity level are represented by using the contour and three-dimensional plot. It is verified that this method is effective to the assessment of engine noise. It can be found that the maximum intensity is radiated from the front side of the engine under idling condition and the right side of it under 2, 000 rpm running with no loading condition at overall level, and also that the maximum intensity is radiated from the oil pan and the intake and exhaust manifold at the center frequency of 100 Hz.

  • PDF