• 제목/요약/키워드: 0-mode

검색결과 4,601건 처리시간 0.04초

흑연/에폭시 복합재료의 혼합모우드 층간분리 해석 (Analysis of Mixed Mode Delamination in Graphite/Epoxy Composite)

  • 염영진;유희
    • 한국자동차공학회논문집
    • /
    • 제4권4호
    • /
    • pp.171-178
    • /
    • 1996
  • DCB(pure mode I) and CLS(mixed mode) tests were performed to investigate the effect of fracture mode on the interlaminar fracture of composite laminate. Mode I critical strain energy release rate was found to be $133J/m^2$ from the DCB test and total strain energy release rate decreased from $1, 270J/m^2$ as thickness ratio(tl/t) varied from 0.333 to 0.667 from the crease from the CLS test. Crack length had no effect on the total strain energy release rate and load was almost constant during the crack growth of the specimen which had the specific thickness ratio. Crack initiated when the stress of the strap ply reached constant stress $42kgf/mm^2$ which was found to be independent of the thickness ratio.

  • PDF

슬라이딩모드 상태관측기를 이용한 유도전동기의 강인한 속도제어 (Robust speed control of induction motor using sliding mode state observer)

  • 윤병도;김윤호;김춘삼;김찬기;한재혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.280-282
    • /
    • 1994
  • This paper proposes sliding mode state for robust speed control of induction motor. Sliding mode state observer is robust for measurement noise, modeling-error and load disturbance. The pole of sliding mode state observer can be placed at (0,0) in Z-plane for fast response. This method is, namely, deadbeat control. Sliding mode state observer output is discontinuous on a switching hyperplance, that causes harmful effects such as current harmonics and speed oscillation. In this paper, also the reducing method of the chattering of sliding mode state observer output is proposed. The proposed system is digitally implemented with TMS320C31.

  • PDF

Passive Mode-Locking of Nd:YAG laser with Saturable Absorber

  • Ahn, Seung-Joon
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 1989년도 제4회 파동 및 레이저 학술발표회 4th Conference on Waves and lasers 논문집 - 한국광학회
    • /
    • pp.13-19
    • /
    • 1989
  • Passive mode-locking of a pulsed Nd:YAG laser is achieved with saturable absorbers, BDN dye in iodoethane solvent and Kodak Eastman # 26 dye in 1,2-dichloroethane solvent, and its optimum conditions are investigated. The thickness of saturable absorbers employed in the laser mode-locking is 0.16~0.50mm. The PBR (peak-to-background ratio) measured in the oscilloscope is 79.8% in Kodak Eastman # 26 dye at the neighbourhood of the peak power, whereas the passive mode-locking with BDN dye gives PBR of 67.7%. BDN and Kodak Eastman # 26 dyes are superior in photostability over Kodak eastman # 9860 and # 9740 dyes which were used previously in passive mode-locking. From the PBR curve, we find that Kodak Eastman # 26dye is more effective than BDN dye in passive mode-locking. The spacing between the adjacent pulses of the pulse train, which depends on the laser cavity length, is measured and is found to be 7 nsec for the cavity length of 100cm.

  • PDF

In-line Dual-Mode DBR Laser Diode for Terahertz Wave Source

  • Chung, Youngchul
    • Current Optics and Photonics
    • /
    • 제4권6호
    • /
    • pp.461-465
    • /
    • 2020
  • A dual-mode laser terahertz source consisting of two in-line distributed Bragg reflector (DBR) laser diodes (LD) is proposed. It is less susceptible to residual reflections from facets than an in-line dual-mode distributed feedback (DFB) LD. The characteristics of the proposed terahertz source are theoretically investigated using a split-step time-domain simulation. It is shown that terahertz waves of frequencies from 385 GHz to 1725 GHz can be generated by appropriate thermal tuning of two DBR LDs. The dual-mode DBR LD terahertz source exhibits good spectral quality for residual facet reflectivity below 0.02, but facet reflectivity of the in-line dual-mode DFB LD terahertz source should be below 0.002 to provide similar spectral quality.

AW CAM의 광도곡선 분석 (THE LIGHT CURVE ANALYSIS OF AW CAM)

  • 김천휘;한원용
    • Journal of Astronomy and Space Sciences
    • /
    • 제12권1호
    • /
    • pp.21-29
    • /
    • 1995
  • $\beta$ Lyrae형 식쌍성 AW Cam을 UBV 세파장 영역에서 광전 관측하여 얻은 UBV 광도곡선을 Wilson and Devinney 쌍성 모델의 2가지 mode( mode 2와 mode 5)로 분석하였다. 이는 Russo and Milano (1983)가 산출한 측광 질량비(q=0.21)와 Mammano et al. (1967)의 분광질량비(q=0.43)가 일치하지 않는 모순-AW Cam 계의 남아 있는 문제인-올 해결하기 위한 것이다. Mode 2로 구한 측광학적 해가 mode 5로 구한 해보다 관측된 광도곡선을 더 잘 반영하는 것으로 계산되었다. 이는AW Cam이 정상준분리형계가 아나라 분리형 쌍성계임을 제시하는 것으로 해석될 수 있다. 또한 산출한 질량비 (q=0.43)로 계산한 AW Cam계의 삼차원 로쉬 모형을 보면 가벼운 반성은 안쪽 로쉬 한계면에 잘 들어 있는 반연 더 무거운 주성이 로쉬 한계면에 거의 접촉하고 있다. 로쉬 기하, 공전주기의 일정성, 그리고 다른 측광학적 증거들로 부터 AW Cam은 Giuricin and Mardrossian (1981)이 제안한 ‘접촉이 깨진 상태’에 있는 진화된 분리형 쌍성계가 아니라, ‘접촉 상태’로 가고 있는case A 진화 상 태에 있는 덜 진화된 분리형 쌍성계로 잠정적으로 결론짓는다

  • PDF

전 척추 전.후 방향 검사 시 AEC Mode와 Fix Mode에서 PC-Based Monte Carlo Program을 이용한 장기선량 및 유효선량 평가 (Evaluation of Organ and Effective Dose using A PC-Based Monte Carlo Program in AEC Mode and Fix Mode for the whole spine antero-posterior radiography)

  • 김정진;장성원;박장흠;이관섭;하동윤
    • 대한디지털의료영상학회논문지
    • /
    • 제14권2호
    • /
    • pp.23-31
    • /
    • 2012
  • There are AEC mode and fix mode to exposure when the whole spine antero-posterior radiography is done by using DR equipment. This study compared the utility of fix mode to AEC mode, by evaluating organ dose and effective dose and by examining the quality of radiographic image. GE DEFINIUM 8000 and ART-200X Rando Phantom manufactured by Flukebiometical were used for this study. The Rando phantom was set in front of wall detector of X-rays equipment. AEC mode was set at 80kVp and Fix mode was set at 80kVp, 25mAs, 32mAs, 40mAs, and 50mAs. Whole spine AP image were aquired by combining C, T-L and L-S spine images obtained through 3 exposures. When obtaining C, T-L and L-S spine images, were checked for Air kerma (mGy) value calculated by UNFORS Xi meter attached at the phantom surface of center of radiation field. The effective and organ doses were compared by PCXMC program (PC-Based Monte Carlo Program). The quality of obtained radiographic image was evaluated visually by 3 radiologists using resolution chart. When the effective doses was calculated based on tissue weighting factor of ICRP-103, 1.278mSv was measured by AEC mode, and Fix mode measured 0.405mSv at 25mAs, 0.518mSv at 32mAs, 0.649mSv at 40mAs, and 0.810mSv at 50mAS. In addition, the organ dose measured with esposure at 25mAs by Fix mode was almost equivalent to the organ dose by AEC mode, at the esophagus, thyroid, oral mucosa, salivaly glands located at the cervical spine part, while the organ dose by Fix mode was in general lower than the organ dose by AEC mode at the other organs. When Fix mode at 32mAs, 40mAs, and 50mAs was compared to AEC mode for organ dose in 26 organs, AEC mode had higher measurement in 21 organs but not for than brain, trachea, thyroid, oral mucosa, and salivaly glands which are located at the cervical spine part. The image quality evaluated by resolution test chart was much higher with AEC mode than the quality with Fix mode at all exposure conditions. However, while the image quality of cervical spine exposured at 50mAs by Fix mode was lower than the quality of AEC mode, thoraco-lumbar spine and lumbo-sacral spine were calculated and the quality was similar to AEC mode. Scoliosis occurs mainly at thoraco-lumbar and lumbo-sacral spine, not at cervical spine. Compared to AEC mode, Using the appropriate protocol (80kVp, 50mAs) of fix mode for whole spine AP radiography was thought to be useful because the image quality of the thoraco-lumar and lumbo-sacral spine was similar on AEC mode, Also organ and effective doses can be decreased with Fix mode. Therefore, It is considered that fix mode can be used properly with AEC mode for whole spine AP radiography when considering patient's body posture.

  • PDF

수치해석과 모형실험을 통한 매립배관에서의 유도초음파 L(0,2) 모드의 감쇠 특성 평가 (Attenuation Characterization of L(0,2) Guided Wave Mode through Numerical Analyses and Model Experiments with Buried Steel Pipe)

  • 이주원;나원배
    • 한국해양공학회지
    • /
    • 제27권1호
    • /
    • pp.16-23
    • /
    • 2013
  • By carrying out numerical analyses and model experiments, this paper presents the attenuation characterization of an L(0,2) guided ultrasonic wave propagating in a buried steel pipe. From this investigation, we first find that the L(0,2) mode has a better attenuation property. Second, it is shown from the numerical analyses that the attenuation increases with increases in the soil embedment length (0, 500, 1000, and 1500 mm) and degrees of saturation (0, 50, 99, and 100%). Third, it is also shown from the model experiment that the attenuation increases as the embedment lengths and soil moisture quantities (0, 10, 20, and 30 kg) increase. Finally, we find that an exponential extrapolation gives a better attenuation prediction because the extrapolation gives similar attenuation patterns between the numerical and experimental results.

Current Mode Signaling 방법을 이용한 $0.18{\mu}m$ CMOS 3.2-Gb/s 4-PAM Serial Link Receiver (A $0.18{\mu}m$ CMOS 3.2-Gb/s 4-PAM Serial Link Receiver Using Current Mode Signaling)

  • 이정준;정지경;범진욱;정영한
    • 대한전자공학회논문지SD
    • /
    • 제46권10호
    • /
    • pp.79-85
    • /
    • 2009
  • 본 논문은 $0.18{\mu}m$ CMOS 공정을 이용하여 3.2 Gb/s serial link receiver를 설계하였다. High-speed links의 performance를 제한하는 가장 큰 요소는 transmission channel bandwidth, timing uncertainty가 있다. 이러한 문제점을 해결하기 위한 방법으로 multi-level signaling(4-PAM)을 이용하였다. 추가적으로 전송속도를 높이고 BER를 낮추기 위한 방법으로 current-mode amplifier, CML sampling latch를 사용하였다. 4-PAM receiver의 최대 데이터 전송속도는 3.2 Gb/s이다. BER은 $1.0{\times}10^{-12}$ 이하이며 chip size는 $0.5\;{\times}\;0.6\;mm^2$이고 1.8 V supply voltage에서 49mA current를 소모한다.

미끄럼 속도변화에 따른 철강재료의 미끄럼 마모거동 (중마모 거동에 미치는 연마모 도입시험의 영향) (Sliding Wear Behavior of Carbon Steel in changing Sliding Speed (Effects of Mild Wear Mode Test on subsequent Severe Wear Behavior))

  • 이한영
    • Tribology and Lubricants
    • /
    • 제36권3호
    • /
    • pp.117-123
    • /
    • 2020
  • In this study, the effect of the pre-mild wear mode test condition on the subsequent severe wear behavior of carbon steel has been investigated when the wear mode is varied according to the sliding speed change during sliding contact. Two sliding speeds of 0.3 m/s and 3 m/s for the mild wear mode test have been chosen and a sliding speed of 1 m/s for the severe wear mode test. A mild wear mode test at two different sliding speeds has been carried out during the severe wear mode test and total sliding distance of the mild wear mode test has been changed at this time. As a result, it could be found that the wear rate of carbon steel under the severe wear mode test after performing a pre-mild wear mode test is significantly reduced, compared with that before performing. However, its wear rate was slightly higher than that under the mild wear mode test. Oxides produced during the pre-mild wear mode test have been found to play a significant role in reducing the wear rate under the subsequent severe wear mode test. In particular, it was found that the effect of a pre-mild wear mode test performed at the sliding speed of 3 m/s has more rapid and the reduction in the wear rate was greater than thst at the sliding speed of 0.3 m/s.

층간파괴인성치에 대한 섬유방향의 영향에 관한 연구 (A Study on the Effect of Fiber Orientation on the Interlaminar Fracture Toughness)

  • 이정규;엄윤성;김형진;고성위
    • 한국해양공학회지
    • /
    • 제9권2호
    • /
    • pp.89-97
    • /
    • 1995
  • The investigate the effect of fiber orientation on the interlaminar fracture toughness of carbon fiber reinforced plastics three prepregs which are domestic products are used in this paper. Those are used for the unidirectional composites, but only one is used for the cross-ply laminate composites which is molded $[0/90]_{6s},\;[0/45]_{6s},\;and\;[0/45/90]_{4s}$. The specimens used for the mode I and mode II Tests are DCB and ENF samples are examined by scanning electron microscope(SEM). The value of $G_{IC}$ is almost same when modified three calculating methods are applied. The highest value of $G_{IC}$at crack initiation is obtained at the $[0/90]_{6s}$ interlaminar and the lowest one is at the $[0/45/90]_{4s}$ interlaminar. The highest value of $G_{IIC}$ at crack initiation, however, is obtained at the $[0/90]_{6s}$ interlaminar and the lowest one is at the $[0/45]_{6s}$. The photographs of SEM show a difference behaviour between mode I and mode II fracture surface.

  • PDF