• Title/Summary/Keyword: 0-mode

Search Result 4,601, Processing Time 0.037 seconds

Electrical Characteristics of SMD Type Ceramic Resonators using PbTiO3 System as a Function of Electrode Radius Size (전극직경 크기에 따른 SMD형 PbTiO3계 세라믹 공진자의 전기적 특성)

  • 민석규;류주현
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.8
    • /
    • pp.671-677
    • /
    • 2002
  • In this study, the high frequency SMD ceramic resonators with the size of $3.7{\times}3.1{\times}0.385\textrm{mm}^3$ were fabricated using $Pb_{0.88}(La_{0.6}Nd_{0.4})_{0.08}(Mn_{1/3}Sb_{2/3})_{0.02}Ti_{0.98}O_3$ ceramics with the variations of electrode radius size. With increasing the electrode radius size, resonant resistance in third overtone mode was decreased and electromechanical coupling factor($k_{t3}$) in third overtone mode was showed constant values. Taking into consideration mechanical quality factor($Qm_{t3}$) of 5,552 and dynamic range(D.R) of 60.72dB in third overtone mode, the ceramic resonator with the electrode radius size of $\theta$1.13mm was suitable for 20MHz resonator application.

Image Quality and Dose Assessment According to Examination Mode during Head CT Examination (두부 CT 검사 시 검사 모드에 따른 화질 및 선량평가)

  • Gang, Heon-Hyo;Choi, Woo-Jeon;Kim, Dong-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.4
    • /
    • pp.437-444
    • /
    • 2021
  • To evaluate the usefulness of Volume Axial Mode by comparing analyzing the exposure dose of the patients and the quality of each images from CT images obtained from high pitch mode using the local phantom or volume axial mode to determine the usefulness of he volume axial mode in diagnosing the head and cervical disease in adults. High Pitch Mode, Helical Mode, and Volume axial Mode as adult phantom were tested according to 70 kVp, 80 kVp, and 100 kVp tube voltages during an adult frontal CT scans. The equipment used was GE's Revolution (GE Healthcare, Wisconsin USA) model and iMED X-ray Phantom. The exposure dose of phantom was compared using the images obtained from each protocol, and the image quality was compared by calculating SNR and CNR by setting ROI on each image. When examined using Volume Axial Mode, the exposure dose of phantom was measured 17.12% lower than Helical Mode, 5.35% lower than High Pitch Mode, and both SNR and CNR were improved. Volume Axial Mode is a useful test that reduces investigation time without table movement using high speed rotary scanner, and in which exposure dose is reduced and image quality is improved by acquiring images in a short time of 0.28 seconds of phantom than using High Pitch Mode and Helical Mode. In addition, the fast testing time of Volume Axial Mode can be seen as the biggest advantage CT scans of emergency patients or patients with physical discomfort.

CMOS Power Amplifier Using Mode Changeable Autotransformer (모드변환 가능한 단권변압기를 이용한 CMOS 전력증폭기)

  • Ryu, Hyunsik;Nam, Ilku;Lee, Dong-Ho;Lee, Ockgoo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.4
    • /
    • pp.59-65
    • /
    • 2014
  • In this paper, in order to improve efficiency performance of power amplifiers, a mode changeable autotransformer is proposed. Efficiency performance at the low-power mode can be improved by adopting the mode changeable autotransformer. A dual-mode autotransfomrer CMOS power amplifier using a standard 0.18-${\mu}m$ CMOS process is designed in this work. Number of turns in a primary winding is re-configurated according to mode change between the high-power mode and the low-power mode. Thus, the efficiency performance of the power amplifier at each mode is optimized. EM and total circuit simulation results verify that low-power mode power added efficiency(PAE) at 24dBm output power is improved from 10.4% to 26.1% using the proposed multi-mode operation.

Mixed Mode Interlaminar Fracture Behaviors of Carbon Fabric/Epoxy Composites (탄소섬유직물/에폭시 복합재의 혼합모우드 층간파괴 거동)

  • Yoon, Sung-Ho;Heo, Kwang-Soo;Oh, Jin-Oh
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.35 no.1
    • /
    • pp.58-65
    • /
    • 2007
  • Mixed mode interlaminar fracture behaviors of carbon fabric/epoxy composites were investigated through MMF (Mixed Mode Flexural) test by varying mixed mode ratio ranging from 20% to 90%. Mixed mode interlaminar fracture criteria based on NL point and 5% offset point were also suggested in order to predict mixed mode interlaminar fracture behaviors. Fracture surfaces and crack propagating behaviors were examined through a travelling scope and a scanning electron microscope. According to the results, mixed mode interlaminar fracture behaviors can be predicted by mixed mode interlaminar fracture criterion with m=1.5 and n=0.5 on the basis of NL point or mixed mode interlaminar fracture criterion with m=2 and n=3 on the basis of 5% offset point. Fracture surfaces and crack propagating behaviors are sensitive to mixed mode ratios. MMF test can be successfully applicable in evaluating mixed mode interlaminar fracture toughness of carbon fabric/epoxy composites.

Single mode yield analysis of index-coupled DFB lasers above threshold for various facet reflectivity combinations (Index-coupled DFB 레이저의 여러 가지 양 단면 반사율 조합에 따른 문턱 전류 이상에서 단일 모드 수율 해석)

  • 김상택;전재두;김부균
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.3
    • /
    • pp.298-305
    • /
    • 2003
  • We have calculated the single mode yield of index-coupled (IC) DFB lasers above threshold for several kL, and facet reflectivity combinations, and investigated the correlation between those results and the single mode yield as a function of f number at the threshold. As a result, there is little correlation between the single mode yield above threshold and the single mode yield as a function of f number at the threshold. The single mode yields above threshold for kL of 0.8 and 1.25 is larger than those for kL, of 2 and 3 due to the spatial hole burning effect. Also, we have investigated the effect of the reflectivity of the AR facet on the single mode yield for AR-HR and AR-CL combinations. For AR-HR combinations, the single mode yield increases as the reflectivity of the AR facet decreases. However, for AR-CL combinations, the reflectivity of the AR facet for the largest single mode yield exists. In the single mode yield calculations for IC DFB lasers in this paper, the single mode yield for kL of 0.8 with AR(1%)-HR combination is largest above threshold.

Development Of Virtual Reality System For The Training And Assessment Of Proprioception During Upper-limb Reaching Task: A Pilot Study (상지재활 훈련동안 자기수용감각의 훈련 및 평가를 위한 가상현실 시스템 개발: 예비연구)

  • Cho, Sang-Woo;Ku, Jeong-Hun;Han, Ki-Wan;Lee, Hyeong-Rae;Park, Jin-Sick;Lee, Won-Ho;Shin, Young-Seok;Kim, Hong-Joon;Kang, Youn-Joo;Kim, In-Young;Kim, Sun-I.
    • 한국HCI학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.749-753
    • /
    • 2008
  • Proprioception defined it as the ability to detect, the spatial position or movement of joints using balance, power of the muscle, agility in the internal parts of the body. In existing study for improvement of proprioception, reaching task training provided a feedback; the assessment was not provided a feedback. But, this has problem that it can not guide a proprioception from situation with visual feedback. Virtual reality technique can solve the problem of way providing feedback during training. In this study, we developed proprioception training program using virtual reality and pilot study is performed. VR task were composed three modes. In mode 1, real-time movement of the body was provided using visual feedback. In mode 2, body position was provided using visual feedback when participant have specific response. And in mode 3, body position was not provided. VR task is performed five sessions at each mode and one session performed one by one a three target. In the result of this study, the moving time toward the target from mode 3 was smaller than the moving time toward the target from mode 1 (p= 0.001). The correlation was statistically significant between mode 2 and mode 3 while be offering visual feedback position of mode 2 1session. But, the correlation was not statistically significant between mode 2 and mode 3 after be offered visual feedback position of mode2 1session (p = 0.012). Training environment of mode 1 shows which training used visual feedback than proprioception. Mode2 can execute training of proprioception because first session acquires visual feedback by proprioception. The next study will be verification of the system for training or assessment by clinical experiment.

  • PDF

A Method of Intra Mode Coding for Joint Exploration Model (JEM) (차세대 비디오 부호화 실험모델(JEM)의 화면내 예측 모드 부호화 기법)

  • Park, Dohyeon;Lee, Jinho;Kang, Jung Won;Kim, Jae-Gon
    • Journal of Broadcast Engineering
    • /
    • v.23 no.4
    • /
    • pp.495-502
    • /
    • 2018
  • JVET (Joint Video Exploration Team) which explored evolving technologies of video coding with capabilities beyond HEVC (High Efficiency Video Coding), released a references software codec named the Joint Exploration Model (JEM) for performance verification of coding technologies. JEM has 67 intra prediction modes that extend the 35 modes of HEVC for intra prediction. Therefore, the enhancement of the coding performance is limited due to the overhead of prediction mode coding. In this paper, we analyze the probabilities of prediction modes selections, and then we propose a more efficient intra prediction mode coding based on the results of analyzed mode occurrence. In addition, we propose a context modeling for CABAC (Context-Adaptive Binary Arithmetic Coding) of the proposed mode coding. Experimental results show that the BD-rate gain is 0.02% on the AI (All Intra) coding structure compared to JEM 7.0. We need to optimize context modeling for additional coding performance enhancement.

A Study on the Behavior of Ultrasonic Guided Wave Mode in a Pipe Using Comb Transducer (Comb Transducer를 이용한 파이프 내 유도초음파 모드의 거동에 관한 연구)

  • Park, Ik-Keun;Kim, Yong-Kwon;Cho, Youn-Ho;Ahn, Yeon-Shik;Cho, Yong-Sang
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.2
    • /
    • pp.142-150
    • /
    • 2004
  • A preliminary study of the behavior of ultrasonic guided wave mode in a pipe using a comb transducer for maintenance inspection of power plant facilities has been verified experimentally. The mode identification has been carried out in a pipe using the time-frequency analysis methods such as the wavelet transform(WT) and the short time Fourier transform (STFT), compared with theoretically calculated group velocity dispersion curves for longitudinal and flexural modes. The results are in good agreement with analytical predictions and show the effectiveness of using the time-frequency analysis method to identify the individual modes. It was found out that the longitudinal mode(0,1) is less affected by mode conversion compared with the other modes. Therefore, L(0,1) is selected as an optimal mode for the evaluation of the surface defect in a pipe.

Current to Voltage Converter for Low power OFDM modem (저전력 OFDM 모뎀 구현을 위한 IVC설계)

  • Kim, Seong-Kweon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.3 no.2
    • /
    • pp.86-92
    • /
    • 2008
  • Othogonal Frequency Division Multiplexing(OFDM) has been taken notice of 4th generation communication method because it has a merit of high data rate(HDR). To realize HDR communication, The OFDM a s high efficient Fast-Fourier-Transform (FFT)/Inversion FFT (IFFT) processor. Currently OFDM is realized by Digital Signal Processor(DSP) but it consumes a lot of Power. Therefore, current-mode FFT LSI has been proposed for compensation of this demerit. In this paper, we propose IVC for current-mode FFT LSI. From the simulation result, the output value of IVC is more than 3V when the value of FFT Block output is more than $7.35{\mu}A$. The output value of IVC is lower than 0.5V when the value of FFT Block output is lower than $0.97{\mu}A$. Designed IVC Low-power Current mode FFT LSI will contribute to the operation of current-mode FFT LSI and the development of next generation wireless communication systems.

  • PDF

Design of OTA Circuit for Current-mode FIR Filter (Current-mode FIR Filter 동작을 위한 OTA 회로 설계)

  • Yeo, Sung-Dae;Cho, Tae-Il;Shin, Young-Chul;Kim, Seong-Kweon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.7
    • /
    • pp.659-664
    • /
    • 2016
  • In this paper, we suggest operational trans-conductance amplifier(OTA) for current-mode FIR filter that can be used in a digital circuit system requiring high operating frequency and low power consumption. The current-mode signal processing is one of the very innovative design method for a low power consumption system with high operating frequency because it shows a constant power regardless of frequency. From the simulation result using 0.35um CMOS process, when Vdd is 2V, it is confirmed that the proposed circuit showed the dynamic range of the about 1V, about 50% of supply voltage and output current swing of about 0~200uA. Also, the power consumption was evaluated with about 21uW and the active size for an integration was measured with $71um{\times}166um$.