• Title/Summary/Keyword: 흡수판

Search Result 194, Processing Time 0.036 seconds

Study on Shielding using CT Contrast Medium (CT 조영제를 이용한 차폐체에 대한 연구)

  • Gang, Heon-Hyo;Kim, Dong-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.5
    • /
    • pp.693-698
    • /
    • 2018
  • Currently, shields for shielding medical radiation during medical examinations in the medical environment are lead robe and lead glass. Lead, the main component of this shielding, has limitations in lead poisoning and light weight, and high price. Iodine, which is used as contrast medium instead of lead shield, is expected to be effective as a shield because it has radiation absorbing properties. The purpose of this study was to evaluate the effectiveness of shielding by using acrylic plate filled with CT contrast agent for clinical use instead of conventional lead glass. As a result, it was found that the acrylic plate filled with the CT contrast agent showed a shielding effect of 7 times or more when the scattering ray dose was not shielded. Therefore, CT contrast agent composed of iodine is expected to be used as a shield instead of conventional lead glass.

Lateral Resisting Capacity for CFT Column to RC Flat Plate Slab Exterior Connections (CFT 기둥-RC 무량판 슬래브 외부접합부의 횡저항 성능)

  • Song, Ho-Beom;Song, Jin-Kyu;Oh, Sang-Won;Kim, Byung-Jo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.61-64
    • /
    • 2008
  • A combination of CFT column and RC flat plate without formworks is very effectively rapid constructions. This paper verified the lateral resisting capacity of CFT column-RC flat plate exterior connection in comparison with general RC column-flat plate connection and detected moment capacity and ductility capacity of connection according to moment-displacement ratio. We made and tested specimens which have different variables respectively and as a result derive a following conclusion. In CFT-E2 specimen a critical section was extended and maximum moment increased 20% respectively in comparison to general RC column specimen. In BME and CFT-E1 specimens generally shear governed behaviors and CFT-E2 specimen complemented with seismic band, flexure behavior region of slab was extended and also ductility ratio and energy absorptance increased.

  • PDF

CRANIOFACIAL RECONSTRUCTION USING VASCULARIZED OUTER TABLE CALVARIAL BONE FLAP : REPORT OF TWO CASES (혈관화 두개골 외층골피판을 이용한 두개안면부 재건)

  • Kim, Ki-Young;Jeong, Seung-Lyong;Jeong, Joo-Sung;Kim, Chang-Lyong;Lee, Seung-Ho;Park, Mun-Seong;Ryu, Sun-Youl
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.18 no.4
    • /
    • pp.546-554
    • /
    • 1996
  • Vscularized calvarial bone flaps have been useful tools in the reconstuction of different type of bone defects in craniofacial surgery Vascularized bone transfer are often preferred to nonvascularized bone grafts because nonvascularized bone grafts are less resistant to infection, not as mechanically strong, and do not survive well in a poorly vascularized bed. Potential advantages of vascularized outer table calvarial bone flap include proximity to the operative field, membranous origin similar to that of the facial skeleton, maleability which allows for a variety of shapes and sizes, inconspicous donor sit scar. The following are the case reports of two patients who underwent craniofacial reconstruction suing vascularized outer table calvarial bone flap.

  • PDF

Impact Behavior of Fiber/Metal Laminates (FMLs) under Low Velocity (섬유/금속 적층판의 저속 충격 거동)

  • Shi, Yu;Kim, Seung-Hyun;Kim, Byung-Sun;Song, Jong-Il
    • Composites Research
    • /
    • v.23 no.1
    • /
    • pp.8-16
    • /
    • 2010
  • The Fiber/Metal Laminates (FMLs) have been developed as a new composite material for aerospace application to reduce weight and improve damage tolerance. In this study, firstly FMLs were manufactured and the tensile test was performed to investigate the mechanical properties of FMLs. Furthermore, impact behavior of the low velocity on FMLs which consisted of different types of aluminum or fiber/epoxy layers was tested by the drop weight impact tester based on the different impact energy conditions. The load-time and energy-time curves were employed to evaluate the impact performance of different specimens. Moreover, finite element analysis (FEA) was also performed to simulate the tensile test and impact behavior of FMLs under the same conditions with the tests and good agreements have been obtained between the FEA predictions and experimental results.

Arthroscopic Meniscal Repair with Bioabsorbable Devices (생체 흡수성 기구를 이용한 반월상 연골 봉합술)

  • Kim Jong Soon;Shin Kyoo Seog;Lee Dong Hwa;Sok Jin Ho;Park Sang Hwan;Heo Jeong Kuk
    • Journal of the Korean Arthroscopy Society
    • /
    • v.6 no.2
    • /
    • pp.150-155
    • /
    • 2002
  • Purpose : The purpose of this study was to evaluate the clinical results of meniscal repair using the bioabsorbable devices. Materials and Methods : From 1998, 21 meniscal repairs were underwent using the bioabsorbable devices and followed more than 1 year. The Meniscus $Arrow^{\circledR}$(Bionx) and the Meniscal $Fastener^{\circledR}$(Mitek) had been applied. The indication for meniscus refixation was an unstable longitudinal tear in the posterior horn of the medial or lateral meniscus. Concurrent ACL reconstruction with meniscal repair was performed on 9 knees. The clinical result was evaluated using Lysholm knee score. Result : The average Lysholm knee scores for all patients improved from 56 preoperatively, to 89 postoperatively. The type of the device were not significantly related to clinical outcome or Lysholm knee score. But the concurrent ACL reconstruction group and the patients treated within 8 weeks had better clinical result than the others. Conclusion : The all-inside meniscal repair technique using bioabsorbable devices can be considered to be an useful method in the well selected patients and concurrent ACL reconstruction surgery.

  • PDF

The Properties of Microwave Propagation in Discharging Plasma (방전에 의한 프라즈마에서의 마이크로파 전파특성)

  • Yang, In-Eung;No, Bang-Hyeon;Kim, Bong-Yeol
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.5 no.3
    • /
    • pp.31-39
    • /
    • 1968
  • In this paper microwave power propagated through the cold plasma was analyzed and measured with respect to the external magenetic flux density. The d. c discharge plasma was in the rectangular waveguide in which two electrode was inserted, and also the glass diseharge tube inserted in the ractangular wavegside. The direction of microwave pro-pagation, the axis of the discharge tube and external magnetic flux were perpendicular to each other. It showed that the attenuation and absorption of micro wave power propagated in the plasma was increased as the magnetic flux density, the discharge current and the pressure of the gas were increased.

  • PDF

A Study on the Neutron Detection by change of Asphalt Content (아스팔트 함량 변화에 따른 중성자 검출에 관한 연구)

  • Kim, Ki-Joon
    • Journal of the Korea Computer Industry Society
    • /
    • v.8 no.1
    • /
    • pp.9-16
    • /
    • 2007
  • In this study, the change of neutron detection can be use the basic data of asphalt content detector under the influence of the jurisdiction and usage of radioisotopes are limited of $100[{\mu}Ci]$ or less. To obtain neutron detector's properties using design materials in first step phase, the change of neutron detection is to be calculated how can be increase or decrease due to the change of asphalt content, also it look over the change results which is installed absorber(cadmium plate) around moderator(polyethylene) using MCNP Code.

  • PDF

수송용기 충격완충제 용접강도의 충돌거동 영향 평가

  • 구정회;민덕기;남재영;이종경;김영진
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05b
    • /
    • pp.312-317
    • /
    • 1998
  • 사용 후 핵연료 수송용기는 자유낙하 충돌사고에 대비해 양 끝단에 충격완충체를 부착하는데 이 충격완충체의 층격흡수특성은 수송용기의 구조적 안전성애 크게 영향을 미친다. 충격완충체의 층격흡수재를 감싸주는 철제 케이스와, 내부 격막판의 용접 접합부는 제작공정상 일부 부분이 부분접합 형태를 갖기 때문에 완전 접합된 부분이나 모재인 판재 부분에 비해 강도가 약하다. 따라서, 본 연구에서는 충격완충체의 부분접합부와 같은 조건의 접합상태를 고려한 용접시편의 시험을 통해서 충격완충체 케이스의 용접 접합부에 대한 접합강도와 기계적 특성을 분석하고, 접합부의 강도특성이 수송용기의 자유낙하 충돌거동에 미치는 영향을 예측하였다.

  • PDF

Design of Solar tracking system based on Fuzzy Controller (Fuzzy 기반의 태양 추적기 설계)

  • Kim, Gwan-Hyung;Jean, Jae-Hwan;Kang, Sung-In;Oh, Am-Suk;Cho, Hyun-Cheol
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.05a
    • /
    • pp.577-578
    • /
    • 2011
  • 본 연구는 태양광 시스템의 활용에 있어서 태양전지를 활용한 시스템의 구성은 태양에너지를 흡수하기 위하여 계절별 및 실시간으로 태양의 움직임을 추적 해 주는 시스템을 필요로 하며, 태양의 움직임에 따라 태양전지(태양열 판넬)의 방향을 안정적으로 제어하여 가장 효율이 높은 상태인 태양광과 수직으로 유지해 주는 시스템이 필요로 하고 있다. 본 논문은 계절 별 및 하루의 태양의 경로를 추적하여 태양광을 항상 수직으로 받을 수 있도록 집광판(광전변환:PV(Photovoltic))의 방향을 태양의 위치 좌표에 따라 정확한 위치로 제어하는 Fuzzy 알고리즘 기반의 2축 제어시스템을 설계하고자 한다.

  • PDF

The FEM Analysis of Membrane for LNG Storage Tank (LNG 저장탱크용 멤브레인 개발을 위한 유한요소해석)

  • Oh B.T.;Hong S.H.;Yoon I.S.;Kim Y.K.;Seo H.S.
    • Journal of the Korean Institute of Gas
    • /
    • v.6 no.4 s.18
    • /
    • pp.47-52
    • /
    • 2002
  • Analytical studies have been performed to investigate the strength of the membrane and the reaction force at the anchor point. Using nonlinear FEM code and experiments, the stress analysis of the corrugated membrane related the cryogenic liquid pressure and thermal loading is performed to ensure the stability and fatigue strength of the membrane. This paper reports on the FEM results of membrane.

  • PDF