• 제목/요약/키워드: 흡수식 시스템

검색결과 177건 처리시간 0.035초

Experimental Performance Study of the Bubble Pump for the Diffusion Absorption Refrigerating System (확산형 흡수식 냉동시스템의 기포펌프 성능실험)

  • 이재효;정의갑;윤재호;정의갑
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • 제16권3호
    • /
    • pp.287-292
    • /
    • 2004
  • An experimental investigation was carried out to study the performance of a bubble pump for the diffusion absorption refrigerating system. Ammonia was used as the refrigerant and the helium was charged in order to balance the pressure between the low and high pressure side. As experimental variables, the concentration of ammonia charged into system, heat input, and the pressure of helium were selected. Experimental results show that the generation rate of ammonia vapor and the circulation rate of diluted ammonia solution were increased as the heat input increases, but the ratio of the solution to vapor flow rate was decreased. The generation rate of refrigerant vapor and the circulation rate of diluted ammonia solution increased as the system pressure decreased. Finally under the condition of 25 bars, the concentration of rich ammonia solution was not affected by the generation rate of ammonia vapor and the circulation of diluted ammonia solution.

Type 2 Absorption Cycle to Transport Energy in the Long Distance for District Cooling Application (지역냉방 적용을 위한 LNG냉열 장거리 수송용 제 2종 흡수식 시스템)

  • Cho Young Kyong;Kim Jin-Kyeong;Oh Min Kyu;Kang Yong Tae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • 제17권3호
    • /
    • pp.250-255
    • /
    • 2005
  • The objective of this paper is to develop a new energy transport system for district cooling application by using type 2 absorption cycle. Cold energy from the LNG storage system is utilized as the cooling source of the condenser and the rectifier. The pressures of the system, UAs of the evaporator and the desorber, and the inlet temperatures of the refrigerant to each component are considered as the key parameters. The results show that UA of the evaporator is more dominant parameter on COP than that of the desorber and the optimum system pressure for the demand side is estimated as 525 kPa. For the present system, it is recommended that the refrigerant inlet temperature of the evaporator be lower than $4.3^{\circ}C$ for long-distance transportation. It is concluded that the cold energy from the LNG storage system can be effectively applied to the long-distance transportation system for district cooling application with the type 2 absorption cycle. The optimum operation conditions are also predicted from the parametric analysis.

Growth Characteristics of Net melon and Leaf vegetables to used the Capillary Supplying System (모관양액공급시스템을 이용한 네트멜론 및 엽채소 생육특성)

  • 장전익;김성배
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 한국생물환경조절학회 2003년도 춘계 학술대회 논문집
    • /
    • pp.30-33
    • /
    • 2003
  • 최근 건강에 대한 인지도가 높아감에 따라 농산물의 안정성 요구도가 증가되고 있으며 환경농업의 필요성이 크게 대두되고 있고, 서구식 식문화의 급속한 도입으로 패스트푸드 식품과 육류 소비량의 증가로 신선채소의 소비가 증가되고 있는데 이에 따른 생산비 절감과 안정생산 기술이 요구되고 있다. 따라서 양액 공급에 따른 전력 등 에너지가 필요치 않고 일종의 폐쇄식 수경재배 방법으로써 작물이 주위 환경에 따라 양수분 흡수량이 다르므로 모세관 현상으로 배지내의 수분이 작물의 흡수한 만큼 공급되어 이용되고 배액이 없으므로 공해의 염려가 없고 고품질 채소의 저비용 생산이 가능한 새로운 모관양액공급시스템을 이용하여 양액공급시스템의 효율성을 검정하고 네트멜론과 몇 가지 엽채소의 생육특성을 구명코자 수행하였다. (중략)

  • PDF

Analysis of Thermodynamic Design Data for Cooling of Double -Effect Absorption System of Solar Energy using LiBr - water and Ethylene Glycol Mixture (흡수액으로 에틸렌글리콜이 혼합되고 태양열을 이용한 이중효용 흡수식 시스템의 냉방 특성해석)

  • Won, Seung-Ho;Park, Sang-Il
    • Journal of the Korean Solar Energy Society
    • /
    • 제23권4호
    • /
    • pp.45-54
    • /
    • 2003
  • For cooling of double effect absorption heat pump system of solar heating source, analysis of thermodynamic design data has been done to find the property of Libr-water + ethylene Glycol mixture for working fluid by computer simulation. Derived thermodynamic design data, enthalpy based coefficient of performance and flow ratio for possible combinations of operating temperature for water - LiBr and Ethylene Glycol mixture ($H_2O$ : CHO ratio 10:1 by mole) by computer simulation are done. The obtained results, COP and mass flow ratio of the water - lithium bromide - ethylene glycol system, are compared with data for the water-Libr pair solution.

설비기술 - 평창올림픽 빙상장에 해양심층수 활용한 냉난방 시스템 적용

  • 대한설비건설협회
    • 월간 기계설비
    • /
    • 통권258호
    • /
    • pp.68-70
    • /
    • 2012
  • 평창올림픽 빙상장에 해양심층수를 이용한 냉난방시스템 가동 방안이 추진된다. 국토해양부는 태양광이 도달하지 않는 수심 200m 아래의 해양심층수가 연중 $2^{\circ}C$ 정도를 유지하는 점을 이용해 세계 최초로 올림픽 빙상장에 한국해양연구원의 '해수냉난방시스템' 및 '해수온도차 발전' 연구개발 사업 성과를 적용한다고 밝혔다. 이번 기술이 전기에어컨이나 흡수식 냉동기 등에 적용되면 기존 시스템에 비해 에너지는 60%, 비용은 82%, 이산화탄소 배출량은 64% 줄어들게 된다.

  • PDF

Avoided Cost Analysis on The Thermal Storage Cooling and Gas Absorption Cooling System (축냉식냉방 및 가스흡수식 냉방시스템의 회피비용 분석)

  • Won, Jong-Ryul;Hwang, Sung-Wook;Kim, Jung-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.267-268
    • /
    • 2008
  • 부분축열을 기준으로 주로 300RT급 이상에서 주로 보급되고 있으며, 하계 전력수요를 심야로 이전시켜 전력사용의 효율성을 높일 수 있으며 동시에 하계발전설비를 회피할 수 있는 측냉식냉방에 대한 회피비용을 분석하고자 한다. 가격, 비용, 요금 등의 자료를 조사하여 이를 토대로 캘리포니아테스트(RIM, P, UC, TRC)를 분석하여 그 결과를 통해 적정 지원금여부를 판단하고자 한다. 또한 이에 대한 비교대상으로 중대형급에서 같이 보급되고 있는 가스 흡수식 냉방시스템과 비교 분석하고자 한다.

  • PDF

A Study on Heat Transfer Characteristics for Removal of Absorption Heat in Absorption Process of Ammonia-Water Bubble Mole (암모니아-물 기포분사형 흡수과정에서의 흡수열 제거를 위한 열전달 특성 연구)

  • Lee, Jae-Cheol;Lee, Ki-Bong;Chun, Byung-Hee;Lee, Chan-Ho;Ha, Jong-Joo;Kim, Sung-Hyun
    • Clean Technology
    • /
    • 제7권4호
    • /
    • pp.273-280
    • /
    • 2001
  • An absorber is a major component in the absorption refrigeration systems and its performance greatly affects the overall system performance. In this study, experimental analyses on heat transfer characteristics for removal of absorption heat in ammonia-water bubble mode absorber were performed. Heat transfer coefficients were estimated as the variations of input gas flow rate, solution flow rate, temperature, concentration, absorber diameter and height, and input flow direction. The increase of gas and solution flow rate affects positively in heat transfer. However, the increase of solution temperature and concentration affects negatively. Moreover, under the same Reynolds Numbers, countercurrent flow is superior to cocurrent flow in heat transfer performance. In addition, from these experimental data, empirical correlations which can explain easily the characteristics of heat transfer are derived.

  • PDF

Operating Characteristics of Ammonia-Water Absorber Heat Exchange Cycle (암모니아-물 흡수식 열교환 사이클의 운전 특성)

  • 강인석;김남진;김종보
    • Journal of Energy Engineering
    • /
    • 제10권4호
    • /
    • pp.357-362
    • /
    • 2001
  • A bench type ammonia-water absorber heat exchange cycle was tested by varying the system charging concentration, refrigerating valve opening and weak solution flow rate. It was observed that the cooling capacity was increased as the system charging concentration was increased. Optimum system charging concentration was found for the coolong capacity of the system. The opening rate of refrigerant expansion valve had a direct influence on the refrigerant sub-cooling at the condenser outlet. Optimum sub-cooling was found to be 0~4$^{\circ}C$. As the weak solution flow rate increased the concentration of strong solution and the evaporating pressure decreased. There existed a optimum weak solution flow rate which maximized the cooling capacity and COP.

  • PDF